ML13333B788

From kanterella
Jump to navigation Jump to search
Summary of 820909 Meeting W/Util & Consultants Re Licensee Analyses of Steam Generator Tube Vibration,Fretting & Nonlinear Vibration,Foreign Matls Insp & Steam Generator Wrapper Supports Investigation.Viewgraphs Encl
ML13333B788
Person / Time
Site: San Onofre 
Issue date: 09/23/1982
From: Paulson W
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8209280229
Download: ML13333B788 (3)


Text

September 23, 1982 Docket No. 50-206 LICENSEE:

SOUTHERN CALIFORNIA EDISON COMPANY FACILITY: SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1

SUBJECT:

SUMMARY

OF SEPTEMBER 9, 1982 MEETING On September 9, 1982, members of the NRC staff met with representatives of Southern California Edison Company and their consultants. The pur pose of-the meeting was to discuss the licensee's analyses of stean generator tube vibration, fretting and non-linear vibration; foreign materials inspection; and steam generator wrapper supports investigation. is a list of attendees.

The agenda for the meeting and copies of the viewgraphs used during the presentation are enclosed (Enclosure 2). The licensee's conclusions from these investigations are included in the viewgraphs. The licensee plans to submit a complete report on the steam generator inspections and analysis during the week of September 13, 1982 for NRC review.

Original signed by Walter A. Paulson, Project Manager Operating Reactors Branch #5, Division of Licensing

Enclosures:

As stated cc w/enclosures:

6 See next,page s6oI 8209280229 820923 PDR ADOCK 05000206 0

PDR SURNAME W

.aU.SDn.:.C.C..awcrChi.

NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960

Mr. September 23, 1982 cc Charles R. Kocher, Assistant General Counsel James Beoletto, Esquire Southern California Edison Company Post Office Box 800 Rosemead, California 91770 David R. Pigott Orrick, Herrington & Sutcliffe 600 Montgomery Street San Francisco, California 94111 Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U. S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN: -Chief, Environmental Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814 U. S. Environmental Protection Agency Region IX Office ATTN:

Regional Radiation Representative 215 Freemont Street San Francisco, California 94111 Robert H. Engelken,.Regional Administrator Nuclear Regulatory Commission, Region V 1450 Maria Lane Walnut Creek, California 94596

ENCLOSURE 1 LIST OF ATTENDEES Meeting of September 9, 1982 NAME AFFILIATION W. Paulson NRC J. Rajan NRC E. Murphy NRC B. Curtis SCE R. Cloud SCE K. Wichman NRC C. Y. Cheng NRC A. Zarechnak W

J. Swobe W

M. Patel W

H. Clark W

L. F. Ermold W

L. Frank NRC H. Conrad NRC

0. Bertsch W

A. Vaia W

A. Mathery SCE F. Briggs SCE C. Harberts SCE R. Krieger SCE