Summary of 820819 Meeting W/Util,Bechtel & Eds Nuclear Re Licensee Evaluation of Effects of Pipe Breaks,In Particular, Review Assumptions,Criteria & Methods (SEP Topics III-5.A & III-5.B).List of Attendees Encl
ML13333B776
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 08/31/1982
From: Mckenna E
Office of Nuclear Reactor Regulation
To: Russell W
Office of Nuclear Reactor Regulation
References
TASK-03-05.A, TASK-03-05.B, TASK-3-5.A, TASK-3-5.B, TASK-RR NUDOCS 8209080333
Download: ML13333B776 (4)


Text

- Augu-t 31, 1982 Docket No. 50-206 MEMORANDUM FOR:

William T. Russell, Chief Systematic Evaluation Program Branch Division of Licensing THROUGH:

Christopher I. Grimes, Section Leader Systematic Evaluation Program Branch Division of Licensing FROM:

Eileen M. McKenna Integrated Assessment Project Manager Systematic Evaluation Program Branch Division of Licensing

SUBJECT:

SUMMARY

OF AUGUST 19, 1982 MEETING SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 1 On August 19, 1982, members of the NRC staff met with Southern California Edison personnel and their consultants.

The purpose of the meeting was to discuss the licensee's evaluation of the effects of pipe breaks, in particular, the review assumptions, criteria and methods (SEP Topics III-5.A and III-5.8). A list of attendees is attached.

The licensee presented the approach that is being taken to resolve these topics. For breaks inside containment, the mechanistic approach will be used. In some instances, fracture mechanics analyses and leak detection techniques may be used.

For outside containment, analyses will be per formed to supplement the 1973 study of the effects of pipe breaks.

The simplified mechanistic approach will be used for these analyses. The criteria and assumptions for these analyses were presented to the staff.

Specific items of interest discussed at the meeting include:

O Electric raceways affected by pipe breaks will be identified but the resolution will be deferred pending completion of Appendix R (Fire Protection).

The intent is to coordinate any relocation and modifica tion of electrical equipment needed to resolve both concerns.

Qs=67 OFFICEO.

SURNAME~

I 8209060333 820831

\\ PDR ADOCK 05000206 SPv

  • PDR NRC\\,run~vi Qs 0kI~V-oVs 1n~oMVeys u OFFICAL RECORD CO PY USGPO: 1981-335-960

W. T. Russell

-2 0 The need to analyze consequences of failures in the letdown line downstream of the orifices was discussed. The temperature and pressure of this line have been reduced from reactor conditions and the flow rate is limited by the orifices. The staff indica ted that the licensee could resolve this question by providing further information on the loads that could be produced from such a break.

o The results from the fracture mechanics evaluations performed to date for level D loads with the assumed 4t flaw showed large margins. Therefore, the licensee stated that they did not con sider the extreme loading conditions case specified in the NRC guidance to be required.

o The licensee stated that both topic assessments would be submit ted no later than their commitment date of December 1, 1982.

Ortgigal signed17 Eileen M. McKenna Integrated Assessment Project Manager Systematic Evaluation Program Branch Division of Licensing

Attachment:

As stated cc w/attachment:

E. McKenna P. Y. Chen Yueh-Li C.-Li M. Boyle W. Paulson R. Hermann G. E. Hammond, SCE R. W. Krieger, SCE

. Dietch, SCE

-E Service List OFFICE.

SEPB SEPB EMcKenna:bl CGrimes WRussell SU N

M

)

5 8

.8

/n...8 DAT~ /~582 8/

/82 87/8 DATEN..................

F NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-3

Mr.

R. Dietch San Onofre Unit 1 Docket No. 50-206 Revised 3/30/82 cc Charles R. Kocher, Assistant General Counsel James Beoletto, Esquire Southern California Edison Company Post Office Box 800 Rosemead, California 91770 David.R. Pigott Mr. R. Dietch, Vice President Orrick, Herrington & Sutcliffe Nuclear Engineering and Operations 600 Montgomery Street Southern California Edison Company San Francisco, California 94111 2244 Walnut Grove Avenue Post Office Box 800 Harry B. Stoehr

-Rosemead, California 91770 San Diego Gas & Electric Company P. 0. Box 1831

.San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U. S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN:

Chief, Environmental Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814 U. S. Environmental Protection Agency Region IX Office ATTN:

Regional Radiation Representative 215 Freemont Street San Francisco, California 94111 Robert H. Engelken, Regional Administrator Nuclear Regulatory Commission, Region V 1450 Maria Lane Walnut Creek, CaliforniC 94596 Sa FanisoClio

AUGUST 19, 1982, MEETING ATTENDEES U.S. NUCLEAR REGULATORY COMMISSION AND SOUTHERN CALIFORNIA EDISON CO.

SEP TOPICS III-5.A AND III-5.B NAME AFFILIATION E. McKenna NRC/SEPB S. Ahmed BPC (Bechtel)

R. Grubb EDS Nuclear G. E. Hammond SCE Pei-Ying Chen NRC/SEPB Yueh-Li C. Li NRC/MEB C. R. Myer BPC (Bechtel),

M. Boyle NRC/SEPB W. Paulson NRC/ORB#5 R. W. Krieger SCE R. Hermann NRC/SEPB