ML13333A467

From kanterella
Jump to navigation Jump to search
Discusses NRC 791109 Request for Review of Fuel Cladding Strain & Fuel Assembly Blockage to Demonstrate Compliance w/10CFR50.46 Limits.Facility Has Stainless Steel Fuel Clad & Is Not Affected by 10CFR50.46 Limits
ML13333A467
Person / Time
Site: San Onofre 
Issue date: 01/08/1980
From: Baskin K
Southern California Edison Co
To: Ziemann D
Office of Nuclear Reactor Regulation
References
NUDOCS 8001150312
Download: ML13333A467 (2)


Text

Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNIA 91770 January 8, 1980 Director of Nuclear Reactor Regulation Attention: D. L. Ziemann, Chief Operating Reactors Branch #2 Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

Subject:

ECCS Models San Onofre Nuclear Generating Station Unit 1 Mr. D. G. Eisenhut's letter of November 9, 1979 requested that we review the ECCS calculations for San Onofre Unit 1 in light of data from confirmatory research programs. In particular, Mr. Eisenhut's letter requests that we review fuel cladding strain and fuel assembly flow blockage models to demonstrate compliance with the limits of 10CFR50.46.

As you are aware, 10CFR50.46 applies to nuclear power reactors having fuel with Zircaloy cladding.

The data discussed in Mr. Eisenhut's letter applies specifically to Zircaloy cladding and to the 10CFR50 Appendix K models used for plants having Zircaloy cladding. San Onofre Unit 1, on the other hand, has stainless steel fuel clad. As such, 10CFR50.46 and 10CFR50 Appendix K are not applicable.

The San Onofre Unit 1 ECCS analysis was performed in accordance with the NRC's Interim Acceptance Criteria as described in Mr. P. A. Morris' letter of July 26, 1971.

NRC approval of these analyses in accordance with the Interim Acceptance Criteria was most recently documented in letters dated April 1, 1977 and August 4, 1978.

o038

-2 In view of the fact that the concerns identified in Mr. Eisenhut's letter are not applicable to San Onofre Unit 1, no further action on this matter is necessary.

Subscribed on this day of 1980.

By K. P. Basrin bscribed and sworn to before me this __day of 1980.

OFIILSEAL 4

  • 4DONA WARY wILCMB NOTARY PUBLIC-CALIFORNIA Notary Public in and r the County LOSPRGA0LS ONY of Los Angeles, Stat of California My Commission Expires June 18, 1981