Forwards Requested Info & Drawings for Systematic Evaluation Review
ML13333A403
Person / Time
Site: San Onofre 
Issue date: 08/14/1979
From: Haynes J
SOUTHERN CALIFORNIA EDISON CO.
To: Ziemann D
Office of Nuclear Reactor Regulation
References
TASK-03-06, TASK-3-6, TASK-RR NUDOCS 7908200153
Download: ML13333A403 (10)


Text

Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 August14, 1979 Director of Nuclear Reactor Regulation Attention: D. L. Ziemann, Chief Operating Reactors Branch No. 2 Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

Subject:

Docket No. 50-206 Systematic Evaluation Program San Onofre Nuclear Generating Station Unit 1 Mr. Kaz Campe of the NRC staff informally requested additional informa tion to assist him in his review of San Onofre Unit 1. The requested information and referenced drawings are provided as an enclosure to the letter.

If you have any questions regarding this matter, please let me know.

Very truly yours, J. G. Haynes Chief of Nuclear Engineering 7908200 t

ENCLOSURE ITEM 1 Description of water pipe connections between the Service Water Reservoir (SWR) and the plant systems (e.g., Fire Protection, Charging Lines) in terms of its exposure and vulnerability to potential tornado missiles.

RESPONSE

Drawing 568776, Miscellaneous Water Systems, indicates there are two pipes which connect the SWR with the plant.

A supply pipe, 704-4"-KN1, from the Flash Evaporators to the SWR and a discharge pipe, 811-8"-KN1, from the SWR to the Fire and Service Water Pumps.

The supply pipe provides water to the SWR at an elevation above the water level in the SWR. The discharge pipe is located at the base of the SWR and removes water from the SWR by gravity. The discharge pipe is marked on Drawing 568776.

The following drawings are provided which show the routing of the discharge piping from the SWR to its connection with the Fire and Service Water Pumps.

568776 Rev. 21 Miscellaneous Water Systems 567763 Rev. 1 Service Water Reservoir 5134459 Rev. 0 Civil Utilities Plant Area 568644 Rev. 6 Reactor Auxiliary Building - Area 8 Pipe Tunnel Plan and Sections at Elevation 22'-0" 568692 Rev. 13 Outside Area - Area 14 Plan at Elevation 14'-0" 568694 Rev. 8 Outside Area - Area 14 Sections A-G These drawings indicate that the discharge piping is underground with the exception of its exit from the pipe trench behind the Spent Fuel Building.

The piping runs above ground at an elevation of 24'O" to 22'O" until it comes to the Fire and Service Water Pumps.

(See Drawing 568694 Sections E-E and B-B.)

Once the pipe reaches the vicinity of the Fire and Service Water Pumps, the piping drops down to the pumps at an approximate elevation of 15'6".

The ground level between the area of the pipe trench and the pumps varies from 14'6" and 14'O".

The only area of the discharge piping vulnerable to potential tornado missiles is where it exits the pipe trench and connects to the Fire and Service Water Pumps.

This area is located between the Spent Fuel Building and the Refueling Water Storage Tank.

In the event it becomes necessary to close the discharge line, a normally open manually operated gate valve located on the bluff can be closed (see Drawing 567763).

-2 ITEM 2 Location of feedwater regulating valves and associated piping serviced by and in the vicinity of the Auxiliary Feed Pumps.

RESPONSE

The feedwater regulating valves are located in the turbine building in Area 2. The following figures have been provided to show the location of the feedwater regulating valves and the orientation of the piping associated with these valves.

Figure 8*

Turbine Generator Area floor plan at Elevation 14'-0" Figure 9*

Turbine Area 2 Sections A, B, & C 568586, Rev. 11 Turbine Area 2 Plan at Elevation 42'-0" to Elevation 24'-9" 334537, Rev. 2 Isometric Line No. 391-10"-EG from FCV 458 thru Pen C-3B to Stm, Gen. E-lC 334538, Rev. 2 Isometric Line No. 392-10"-EG from FCV 457 thru Pen C-3C to Stm. Gen. E-1B 334539, Rev. 1 Isometric Line No. 393-10"-EG from FCV 456 thru Pen C-3A to Stm. Gen. E-lA 334540, Rev. 1 Isometric Line 4"-EG from CV142 to Line 393-10"-EG 334541, Rev. 1 Isometric Line 4"-EG from CV144 to Line 392-10"-EG

334542, Rev. 1 Isometric Line 4"-EG from CV143 to Line 391-10"-EG The auxiliary Feedwater Pumps, G10, and GlOS, are located in the turbine building in Area 6.

The following drawings have been provided to show the location of the pumps and the piping serviced by these pumps.

In addition, P&I Diagram 568779, Feedwater and Condensate, shows the routing of the piping for the feedwater regulating valves, the bypass regulating valves and the Auxiliary Feedwater Pumps.

  • These figures were taken from the SONGS 1 Report on Effects of a Piping System Break Outside the Containment dated December 1973.

-3 568779 Rev. 21 Feedwater and Condensate 568631 Rev. 18 TUrbine Area 6 Plan at Elevation 21'-10" to Elevation 8'-6".

334751 Rev. 0 Isometric Line 380-4"-BG from Line 721-10" to Aux. Feed Water Pump G-10.

334752 Rev. 0 Isometric Line 396-4" -HP from Line 380-4" to Aux. Feed Water Pump G-105.

334753 Rev. 1 Isometric Line 397-3"-EG from Disc. of Aux.

Feed Water Pump G-10S to Valve 3-600-37.

334754 Rev. 0 Isometric Line 381-3"-EG from Disc. of Aux.

Feed Water Pump G-10 to Valve 3"-600-37; 384-2"-EG Drain.

334758 Rev. 0 Isometric Line 381A-3"-BG, 381A-4"-BG, from 381-3"-BG to 381A-4"-BG.

334759 Rev. 0 Isometric Line 381A-4"-G, 381A-3"-EG, 381B-3"-G, 381C-3"-EG, from 381A-4" to Stm. Gen. E-lA, lB & IC.

ITEM 3 Heater deck construction.

RESPONSE

One story steel frame heat platforms are on the east and west sides of the turbine building above ground level.

Each platform has approximate plan dimensions of 112 feet by 50 feet and supports an 8-1/2 inch thick prestressed concrete slab at elevation 35 feet, 6 inches.

ITEM 4 Reactor Auxiliary Building wall-roof materials and thicknesses.

RESPONSE

With the exception of the northeast corner, the reactor auxiliary building is a single story, partially embedded, reinforced concrete structure rising to about 6 feet above ground level.

The northeast corner of the reactor auxiliary building includes an additional story with roof level varying from 21 to 28 feet above ground level.

(See enclosed figures for wall and roof thicknesses).

This second story is constructed of masonry walls, conventionally reinforced concrete walls and slabs, and structural steel floor framing.

The overall dimensions of the reactor auxiliary building are approximately 134 feet by 60 feet. The northeast corner which comprises an additional story is approximately 32 feet by 41 feet.

-4 ITEM 5 Location of Regenerative Heat Exchangers (CVCS)

RESPONSE

The Regenerative Heat Exchanger (E-13) is located inside containment in a direct line with the reactor vessel and reactor coolant pump G2B.

The following drawings have been provided to show the location and orientation of the regenera tive heat exchanger inside containment.

568701 Rev. 6 General Arrangement 568568 Rev. 12 Reactor Building Area 1 Plan at Elevation 22'-4" to Elevation 0'-0".

ITEM 6 Location of pressure reducing valves and orifices and associated piping and instrumentation for CVCS.

RESPONSE

The pressure reducing valves and orifices for the CVCS are located inside containment in the general area of the Regenerative Heat Exchanger.

Their location inside containment is shown on Drawing 568568 (See Item 7).

Drawing 334476, Isometric Line Nos. 2071-2"-601R, 2067-2"-2501R & 2068-2"-2501R; Regen.

Hx to Line 3015-6, has been provided to show the orientation of the valves and their associated piping inside containment.