ML13331B372

From kanterella
Jump to navigation Jump to search
Ro:On 800507,during Inservice Insp of Seal Injection Piping for Reactor Coolant Pump 8,weld 2009-2 Found in Excess of Limits of ASME Code Section Ix.Cause Not Stated.Addl Insp Begun & Repairs Will Be Completed
ML13331B372
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 05/07/1980
From: Curran J
SOUTHERN CALIFORNIA EDISON CO.
To:
References
NUDOCS 8005160317
Download: ML13331B372 (2)


Text

.*

REGULATORY *gORMATION DISTRIBUTION SYS*-

(RIDS)7 ACCESSION NBR:8005160317 D0C.DATE: 80/05/07 NOTARIZED: NO DOCKET #

FACIL:50-206 San Onofre Nuclear Station, Unit 1, Southern Californ 05000206 AUTH.NAME AUTHOR AFFILIATION CURRANJ.M, Southern California Edison Co.

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

RO:on 800507,during inservice insp of seal injection piping for reactor coolant pump.8,weld 2009-2 found in excess o~f limits of ASME Code Section IX.Cause not stated.Addl insp begun & repairs will be completed.

DISTRIBUTION CODE: M0078 COPIES RECEIVED:LTR ENCL Q SIZE:.

TITLE: LER (Backfit)

NO0T E IAJ'Wit-,

~.A/.Sc A/,

f ECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL INTERNAL: 0 FILE 1

02 NRC PDR,1 04 2

ED1 BERLINGERC.

1 HANAUER,S 1

MPA 1

,EXTERNAL: 03' LPDR 1

NSIC 1

MAY 2 0 1980 TOTAL NUMBER OF COPIES REUVIRED; LTTR A4' ENCL

.4-

0 05 1 6 0S IfS So~ubern Cal/fornia

  • FdfIsn C2orrnpany0, Moy 7, 1980 U. S. Nuclear Regulatory Cuoviorvi Suite 202, WAlnut Creek Plawe 1990 Horth California Bl1vd.

Walnut Creek. California 94596H GentlIeffieff:

D00CET IN, 50-7-06 SAN ONMEF1 - tNT T1

'This letter detrtieg a promipt reportable occmrreroco involvir~i 0P, chemical and voltmw. control vytef svb4ittal ig in occrdaice with the r-eporting reqvireaents vtipulted in $ection 6,9.2,00) of Apendix A to the Proisional Operatlnj ) e~eD~1 On Ma~y 7o 19190 durIng 1Intrvive Inspectitn of~ 00 seal i jon'0 Piping.

for Recto~r Coolant Pump 9; weld4 7,009-2 was foyind to havo, an indlicto it1 o excess of the al Mvlable I imits of the AISME 4&PV. Cod e ctiovz MX Thi s is a-odket weld Jining, tho pipe to volve FCY--1)l&E Additloytal inmpection as %r*qeired by the ASK4 D&PV Code SPction XI. hars beqmn, Reors wrill be.

completed prior to re~turningn t-he Iteoctor. Coolont, Sy,

to oper409110~

jpregsure~.

Should you have a~ny 4vestiorns vvgardinq this,mater pleose cernt-Ovt me, o,. Crran Mo~nt Mangor