ML13330B451

From kanterella
Jump to navigation Jump to search
Forwards List of Equipment Contained at Matl Test Facility & Purchase Cost for Equipment
ML13330B451
Person / Time
Site: San Onofre  
Issue date: 01/09/1989
From: Medford M
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8901170203
Download: ML13330B451 (3)


Text

Southern California Edison Company P. 0.

BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 M. O.MEDFORD TELEPHONE MANAGER OF January 9, 198 i

(818) 302-1749 NUCLEAR REGULATORY AFFAIRS U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, D.C.

20555

Dear Sir:

Subject:

Docket Nos. 50-206, 50-361 and 50-362 Material Test Facility Equipment San Onofre Nuclear Generating Station Units 1, 2 and 3 At the request.of Mr. E. Baker of the Vendor Program Branch, a list of equipment contained at the San Onofre Site Material Test Facility has been compiled and is being provided in the enclosure to this letter. In addition, the purchase cost for the equipment is being included alongside each item in the list. In some cases, the purchase cost for an individual item is not listed separately, but is included in a total cost with other minor items.

Should you require additional information pertaining to the site Material Test Facility, or the equipment utilized at the facility, please do not hesitate to call me.

Very truly yours, Enclosure cc:

J. B. Martin, Regional Administrator, NRC Region V F. R. Huey, NRC Senior Resident Inspector, San Onofre Units 1, 2 and 3 E. Baker, Vendor Program Branch 8901170203 890109 PDR ADOCK 05000206 NA4 P

PNUK

Enclosure SAN ONOFRE SITE MATERIAL TEST FACILITY EQUIPMENT Item Used For Price 1" OD Micrometers Dimensional Measurement 2" OD Micrometers Dimensional Measurement 31" 0D Micrometers Dimensional Measurement 4" OD Micrometers Dimensional Measurement 5" OD Micrometers Dimensional Measurement 6" 0D Micrometers Dimensional Measurement Total $ 900 1" Micrometer Standard Dim. Measure., Calibration 2" Micrometer Standard Dim. Measure., Calibration 3" Micrometer Standard Dim. Measure., Calibration 4" Micrometer Standard Dim. Measure., Calibration 5" Micrometer Standard Dim. Measure., Calibration 0-6" Depth Micrometers Dimensional Measurement Total 150 Multi-meter Electrial Measurement 125 Dial Depth Gage Dimensional Measurement 75

.0001" Test Indicators Dimensional Measurement 150 Gage Block Sets Dim. Measure., Calibration 1,000 6" Dial Caliper Dimensional Measurement 225 24" Vernier Height Gage Dimensional Measurement 200 Pair V-Blocks with Clamps Dimensional Measurement 125 Ames Portable Hardness Tester Metal Hardness Testing 400 12" Dial Caliper Dimensional Measurement 150 24"x36" Surface Plate w/Base Dimensional Measurement 600 Tri-Square 18" Dim. Measure., Calibration 200 30" Straight Edge Dimensional Measurement 100 12" Parallels Dimensional Measurement 100 Right Angle Block 9" Dim. Measure., Calibration 150 24" Bench Center Dimensional Measurement 4,000 4"x4" Right Angle Blocks Dimensional Measurement 150 600 - 100aF Pyrometer Measures Rubber Hardness 125 12" Digital Caliper Dimensional Measurement 300 12" Digital Height Gage Dimensional Measurement 400 0-1" Panamike Dimensional & Thread Measure.

293 1" - 2" Panamike Dimensional & Thread Measure.

425 Surface Reference Standard Calibration 119 10" Sine Bar Dimensional Measurement 247 0-2" Digital Test Indicator Dimensional Measurement 296 6" Digital Depth Micrometer Dimensional Measurement 243 6" Riser Block Dimensional Measurement 304 12" Height Master Dimensional Measurement 1,398 Bench Digital Hardness Tester Metal Hardness Testing 4,394 with Hardness Test Blocks and Calibration 14" Optical Comparator with Dimensional & Thread Measure.

7,395 Digital Readout/Computer

SAN ONOFRE SITE MATERIAL TEST FACILITY EQUIPMENT Item Used For Price Digital 4" Bench Micrometer Dim. Measure., Calibration 3,259 Small Spring Tension Tester Measures Spring 742 Ring Gages, Thread Plug Gages, Thread Measurement Ring Set Gages NC & NF from

  1. 10 to 1 1/2" Total 8,274 Mini Processor for Digital Records Data 185 Instruments 494 Plug Pin Gages from.006" Dimensional Measurement 394 to 1/2" in increments of.001" Surftest Surface Rough Tester Surface Finish Measurement 2,750 Equotip Portable Hard. Tester Metal Hardness Testing 5,000 "0" Ring Gages Dimensional Measurement 100 Spectrotest L Metal Alloy Alzr.

Does not do sulfur or phosphor.

46,581 Indicator Comparator Stand Dimensional Measurement 100 67 Certified Alloy Standards Calibration 2,282 Pedestal Grinder/Wire Wheel Surface Preparation 282 Bench Disc Grinder Surface Preparation 200 Microfinish Comparator Surface Finish Measurement 2,750 Bevel Protractor Dimensional Measurement Thread Measuring Wire Set Thread Measurement 4 sets of Feeler Gages Dimensional Measurement Screw Pitch Gage Thread Measurement US Standard Gages Dimensional Measurement Telescoping Gages Dimensional Measurement 1" Digital Micrometer Dimensional Measurement Set Radius Gages Dimensional Measurement 8x Pocket Comparator Dimensional & Thread Measure.

Pencil Durometer Hardness of Rubber Total 5,000