ML13330B210

From kanterella
Jump to navigation Jump to search
Change Notice 23 to Amend 9 of QA Program SCE-1-A Reflecting Changes in Calibr Program
ML13330B210
Person / Time
Site: San Onofre  
Issue date: 05/18/1987
From:
Southern California Edison Co
To:
Shared Package
ML13330B209 List:
References
SCE-1-A-A-09, SCE-1-A-A-9, SCE-1-A-A09-R23, SCE-1-A-A9-R23, NUDOCS 8705280310
Download: ML13330B210 (2)


Text

SOUTHERN CALIFORNIA EDISON COMPANY TOPICAL REPORT SCE-1-A CHANGE NOTICE Change Notice Number:

23 Affected Amendment:

9 Affected Pages:

17.2-39 (as modified by CN#18)

Description of Change:

The reference that users of measuring and test equipment shall be qualified per Regulatory Guide 1.8 or 1.58 is being added. This requirement is already implied by Section 17.2.2 of the Topical Report.

Reason for Change (including basis for concluding that the change satisfies the criteria of 10CFR5O, Appendix B, and the quality assurance program commitments previously accepted by the NRC):

Qual-ification requirements for users of measuring and test equipmfent were not clearly stated in Section 17.2.12 of the Topical Report.

The changes proposed implement requirements contained in Section 17.2.2 of the Topical Report and satisfy 10CFR50 Appendix B Criteria II and XII.

Change does X does not reduce commitments previously accepted by the NRC.

Approvals:

Manager of Quality Assurance Vice President Date Submitted to NRC:

May 18, 1987

~~~~6 0 3 0 870518

---7 PDR ADOCK 0500020 PDR,\\

17.2.12.2.2 (continued) o

  • Method of labeling or tagging the equipment to I

indicate date of next required calibration.

o Method for identification of equipment for traceability to the calibration test data.

o Method for establishing calibration intervals based I

on the required accuracy, purpose, degree of usage, I

stability characteristics, and other conditions affecting the application.

o A system for recalling M&TE whose designated period of legitimate use prior to recalibration 9CN#18 has expired.

o Calibration procedures including techniques and methods for adjustment of M&TE.

o Identification of individuals, organizations, and companies authorized to calibrate the M&TE. The user of the M&TE will be qualified per Regulatory I9CN#23 Guide 1.8 or 1.58 as appropriate.

o Provisions for recording the as-found condition of M&TE being calibrated.

o A method for identifying all permanent plant I

equipment that has been calibrated with M&TE that is I found out of tolerance or inoperative.

o Method for identification, control and distribution of calibration data and records.

o Provisions for proper handling and storage of the 9CN#18 M&TE.

o Status of all M&TE is maintained by the organization responsible for the calibration program.

o A means of determining which M&TE shall be included I

(and excluded) from the calibration control program. I This program will specify accuracy requirements and ensure that the inaccuracy of the standards contribute no more than 1/4 of the total inaccuracy of the M&TE being calibrated. A greater uncertainty may be acceptable when limited by "state-of-the-art".

The responsible organization manager reviews and approves calibration procedures required to implement the M&TE calibration program. The SCE Quality Assurance Organization reviews the M&TE calibration program, including those prepared by designated contractors, and performs periodic audits to verify conformance with established calibration program requirements.

17.2-39 Amendment 9 CN#23