ML13330A737

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-10.Forwards Info Re Operator Requalification Examinations
ML13330A737
Person / Time
Site: San Onofre 
Issue date: 05/24/1979
From: Head J
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 7908020219
Download: ML13330A737 (3)


Text

Southern California Edison Company C

P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770....

J.T.

HEAD, JR.

1 97 1

TELEPHONE VICE PRESIDENT 213-572-1472 May 24, 1979 U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region V Suite 202, Walnut Creek Plaza 1990 North California Boulevard Walnut Creek, California 94596 Attention: Mr. R. H. Engelken, Director Docket No. 50-206 San Onofre Unit 1

Dear Sir:

IE Bulletin No. 79-10 Requalification Training Program Statistics IE Bulletin No. 79-10 requests that we furnish certain information con cerning operator requalification examinations at San Onofre Unit 1. The re quested information is provided in enclosed Table 1, consistent with the format prescribed by the bulletin.

Should you have any questions concerning our response or require addi tional information, do not hesitate to contact me.

Sincerely, Enclosure.: Table 1 cc: Office of Nuclear Reactor Regulation, Division of Project Management,Operator Licensing Branch 79080202-) 9

Enclosure I Page 1 of 2 TABLE 1 Utility:

Southern California Edison Company Date: May 24, 1979 Utility:

San Onofre Nuclear Generating Station, Unit 1 Operators Senior Operators Exam Exam Exam Exam Exam Exam Exam Exam 1

2 3

4 1

2 3

4

1. "Action 1: Responses A.

Total number failed 0

0 0

0 0

0 0

0 annual examination B.

Percent that failed 0

0 0

0 0

0 0

0 annual examination

2.

Action 2:

Responses A. Percent required to 71 100 80 75 70 68 39 71 attend additional lectures B. Number of operators 2/1 6/1 5/1 3/1 5/1 7/1 4/1 4/1 attending specified 1/2 7/2 2/2 2/2 2/3 1/2 3/2 1/4 number of lectures 1/4 4/3 3/3 1/3 2/4 3/3 (no. of operators/

1/5 3/4 4/4 1/4 2/5 2/5 no. of lectures) 1/5 1/5 1/6 1/6

3.

Action 3:

Responses A. Total number attending 0

0 0

0 0

0 0

0 accelerated training because 70 percent on annual written examina tion B.

Percent attending 0

0 0

0 0

0 0

0 accelerated training lesson because 70 per cent on annual written examination

Enclosure I Page 2 of 2 Operators Senior Operators Exam Exam Exam Exam Exam Exam Exam Exam 1

2 3

4 1

2 3

4 C. Total number attending 0

0 0

0 0

0 0

0 accelerated training because unsatisfactory oral examination D.

Percent attending 0

0 0

0 0

0 0

0 accelerated training because unsatisfactory oral examination Date of Exam 1:

December 1975 Exam 2:

December 1976 Exam 3:

December 1977 Exam 4:

December 1978