Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 K. P. BASKIN fl~TELEPHONE MANAGER OF NUCLEAR ENGINEERING, October 0,
1980 2
E1401 SAFETY, AND LICENSING Director of Nuclear Reactor Regulation Attention: D. M. Crutchfield, Chief Operating Reactors Branch No. 5 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Gentlemen:
Subject:
Docket No. 50-206 Turbine Disc Integrity San Onofre Nuclear Generating Station Unit 1 Your letter of February 25, 1980, requested Southern California Edison (SCE) provide certain information to the NRC concerning low pressure turbine disc integrity. SCE's letter of March 18, 1980 provided that information.
The purpose of this letter is to provide a revision to that information.
Specifically, the calculated operating stresses (Section E of the attached tables) have been revised to include thermal and pressure drop stresses.
These higher operating stresses result in lower values for the critical crack sizes (Section F of the attached tables).
However, as a result of the disc inspection performed during the Spring of 1980, it was determined that there are no cracks in the San Onofre Unit 1 low pressure turbine discs (Section H of the attached tables).
Therefore, the smaller critical crack sizes have no effect on disc integrity at San Onofre Unit 1.
Appendix A of this letter contains proprietary information of the Westinghouse Electric Corporation. In conformance with the requirements of 10CFR Section 2.790, as amended, of the Commission's regulations, it is requested that this information be withheld from public disclosure. An application for withholding and an affidavit was included in the SCE's March 18, 1980 submittal. Correspondence with respect to the affidavit or application for withholding should reference AW-80-4 and should be addressed to Mr. R.
Williamson, Manager, Customer Order Engineering, Westinghouse Electric Corporation, Steam Turbine Division Lester Branch, Box 9175, Philadelphia, Pennsylvania, 19113.
Appendix B of this letter contains a non-proprietary version of the information contained in Appendix A and is suitable for public disclosure.
Mo 8enove73t4O/
OFFIMAL USE ONLY INFRMATION NOTICE THE ATTACHED DOCUMENT MAY CONTAIN "PROPRI ETARY INFORMATION" OR MATERIAL OF A PRIVACY NATURE, AND SHOULD BE HANDLED AS NRC "OF FICIAL USE ONLY" INFORMATION. IT SHOULD NOT BE DISCUSSED OR MADE AVAILABLE TO ANY PER SON NOT REQUIRING SUCH INFORMATION IN THE CONDUCT OF OFFICAL BUSINESS AND SHOULD BE STORED IN A MANNER WHICH WILL ASSURE THAT ITS CONTENTS ARE NOT MADE AVAILABLE TO UNAUTHOR IZED PERSONS.
NRC FORM 190B OFFICIAL USE ONLY INFORMATION (9-80)