ML13324A850

From kanterella
Jump to navigation Jump to search
Forwards Seawall Insp,San Onofre Nuclear Generating Station Unit 1. Minor Areas of Corrosion Observed That Will Not Affect Seawall Function for at Least 15 Yrs.Monitoring Program Will Not Be Established
ML13324A850
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 05/06/1986
From: Medford M
Southern California Edison Co
To: Lear G
Office of Nuclear Reactor Regulation
Shared Package
ML13324A851 List:
References
NUDOCS 8605080267
Download: ML13324A850 (1)


Text

Southern California Edison Company P. 0.

BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 M.O.MEDFORD TELEPHONE MANAGER, NUCLEAR LICENSING 818) 302-1749 May 6, 1986 Director, Office of Nuclear Reactor Regulation Attention:

G. E. Lear, Director PWR Project Directorate No. 1 U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket No. 50-206 Seawall Inspection Report San Onofre Nuclear Generating Station Unit 1

References:

1. Letter, Darrell G. Eisenhut, NRC, to Kenneth P. Baskin, SCE, dated November 21, 1984
2. Letter, M. 0. Medford, SCE, to W. A. Paulson, NRC, dated November 18, 1984 During the return-to--service program on San Onofre Unit 1 in 1984, corrosion of the intake structure rebar was discovered and repaired. In their SER approving plant restart (enclosed with Reference 1), the NRC staff indicated that a field inspection of the seawall should also be performed.

During the current outage an inspection of the seawall was performed. Enclosed is a report on that inspection. The report identifies that minor areas of corrosion were observed but that they will not affect the seawall function for at least 15 years. A monitoring program will be established to monitor future corrosion.

If there are any questions on the enclosure, please let me know.

Very truly yours, Enclosure cc:

3. B. Martin, NRC Region V, Regional Administrator F. R. Huey, USNRC Senior Resident Inspector, Units 1, 2 and 3 E. McKenna, USNRC, Integrated Safety Assessment Branch 8605080267 860506 PDR ADOCK 05000206 d

G PDR A