Special Rept:On 850424,stack wide-range Gaseous Monitor R-1254 Declared Inoperable Due to Erratic Response of mid-range Channel.Caused by Faulty Detector/Preamp Assembly Connector.Assembly Replaced
ML13324A645
Person / Time
Site: San Onofre 
Issue date: 05/08/1985
From: Haynes J
SOUTHERN CALIFORNIA EDISON CO.
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 8506030522
Download: ML13324A645 (2)


Text

Southern California Edison Company SAN ONOFRE NUCLEAR GENERATING STATION 111

-1 Ull P.O. BOX 128 SAN CLEMENTE, CALIFORNIA 92672 J. G. HAYNES t..

TELEPHONE STATION MANAGER May 8, 1985 (714) 492-7700 U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. J. B. Martin, Regional Administrator

Dear Sir:

Subject:

Docket No. 50-206 Special Report San Onofre Nuclear Generating Station, Unit 1 Pursuant to Section 6.9.3 of Appendix A, Technical Specifications to Provisional Operating License DPR-13 for San Onofre Unit 1, this submittal provides the required 14-Day Special Report for inoperable radiation monitoring instrumentation.

On April 24, 1985, at 1725, with Unit 1 in Mode 1 at 93% power, Stack Wide Range Gaseous Monitor R-1254 was declared inoperable when its mid-range channel was observed responding erratically. The low-range and high-range channels were responding properly. The preplanned alternate method of monitoring was initiated per Limiting Condition for Operation (LCO) 3.5.10, Table 3.5.10-1, Action Statement 27.

Also, in accordance with LCO 3.5.9, Table 3.5.9.1, Action Statement 24, stack flowrate estimates every four hours during planned releases were initiated since the stack flowrate, a function of R-1254, was also declared inoperable.

Subsequent investigation has determined the erratic Mid-Range channel behavior was due to a faulty detector/preamp assembly connector. The detector/preamp assembly has been replaced. Calibration of Monitor R-1254 is still in progress. It is anticipated that Monitor R-1254 will be returned to operable status by May 12, 1985.

8506030522 850508 PDR ADOCK 05000206 S

PDR 706/

MR. J. B. MARTIN

-2 Neither the health and safety of plant personnel nor the health and safety of the public was affected by this event. If you require any additional information, please so advise.