ML13324A519

From kanterella
Jump to navigation Jump to search
Offsite Hazards Evaluation 1984
ML13324A519
Person / Time
Site: San Onofre 
Issue date: 11/30/1984
From:
NUCON, INC.
To:
Shared Package
ML13324A518 List:
References
NUDOCS 8412110350
Download: ML13324A519 (22)


Text

SOUTHERN CALIFORNIA EDISON COMPANY SAN ONOFRE NUCLEAR GENERATING STATION OFFSITE HAZARDS EVALUATION 1984 November 1984 Prepared by:

Nucon Incorporated 8412110350 641205 PDR ADOCK 05000206 F

PDR

TABLE OF CONTENTS I.

INTRODUCTION 1

II.

MONITORING OF HAZARDOUS CARGO 2

III.

EVALUATION OF LONG TERM CHANGES IN OFF-SITE HAZARD PROBABILITIES 7

IV.

CONCLUSIONS 14 REFERENCES 15

OFFSITE HAZARDS EVALUATION I.

INTRODUCTION This report documents the 1984 offsite hazards evaluation performed for San Onofre Units 2/3.

The evaluation consists of monitoring hazardous cargo and assessing long term changes in offsite hazard probabilities. The results of the survey indicate that the frequency of hazardous cargo has increased slightly.

The assessment of the likelihood of a hazard causing a plant accident is very conservative. The value derived is below the limits of SRP 2.2.3.

An assessment of long term trends indicates that it is very unlikely that the frequency will increase enough to exceed the limits of the SRP 2.2.3.

Section II presents the monitoring of hazardous cargo.

The methods and results of the effort are described.

Section III discusses the assessment of long term changes in offsite hazard probabilities.

II.

MONITORING OF HAZARDOUS CARGO A.

Summary In response to the San Onofre Units 2/3 Technical Specifications 6.9.1.14.

requirements for moni toring hazardous cargo traffic every three years on Interstate 5 (1-5) and the Atchison Topeka and Santa Fe Railway, a 1984 survey of the frequency of hazardous cargo travel near the plant has been performed. The results have been used to develop an updated analysis of off-site hazards.

This survey and updated analyses have included consi deration of all identified potentially hazardous material being transported near the plant.

In addition to the evaluation of the current level of activity (transportation) which could represent an off-site hazard, analyses based on site-specific truck survey data trends and an industrial survey of trends in hazardous material use were conducted to estimate the future of off-site hazards at Units 2/3.

B.

Method The original consideration of off-site hazards [1) included analysis of potentially hazardous cargo on both the AT & SF Railway, and Interstate 5 (1-5) 2

To perform an update of the rail hazard, contact was made with representatives of the AT&SF Railroad for civilian transportation.

In addition, contact was made with representatives of the military regarding ordnance shipments by rail.

These contacts confirmed that:

civilian operations of AT&SF Railroad have not changed since the last assessment there has been an embargo on shipment of military ordnance by rail in effect since 1979.

The potential hazard from transportation of hazardous material on the AT&SF railway is therefore expected to be bounded by the previous estimate.

To update the frequency of shipment of hazardous cargo on 1-5, a 7-day (24-hour per day) roadside survey of truck traffic was performed from March 25 through April 1, 1984.

A total of 21,435 trucks were interrogated in the survey.

A total of 625 trucks were found to be carrying cargos which might be hazardous (further evaluation warranted).

The hazardous materials shipped by these trucks were identified and evaluated. Some of the materials were assessed in the previous analysis.

Some were of low hazard potential or were only hazardous in the local vicinity of a wreck. Other new materials 3

identified were evaluated in terms of their chemical composition, physical state, usage and other characteristics. Based upon the similarity of properties of substances identified in the survey to the toxic materials identified in the previous work, an updated frequency of shipment of hazardous materials was determined.

These revised frequencies were used to update the analysis based upon the linear relationship that exists between the shipment frequency and estimated hazard.

A small portion of these new materials is of unknown nature.

The shipment of these unknown materials represents only 2% of the total shipment and is therefore considered to be insignificant.

Table 1 provides a comparison between the previous estimates and the updated estimates using current 1984 data for the off-site hazard at Units 2/3.

The substances found to represent a potentially significant hazard include:

Gasoline Diesel Oil Jet Fuel e

Butane Propane Chlorine, and 4

0 Ammonia For the hazardous explosives transported on 1-5, both military and civilian transporters were evaluated.

The updated explosive hazard and the flammable cloud hazard are included in Table 1.

In addition to the survey, an evaluation was performed on the truck accident rate near the plant.

The truck accident rate for I-5 near San Onofre is 3.5 X 10- 7 /truck mile based on information from the California Highway Patrol [2].

Actual statistics for the roadway adjacent to the plant are consistent with flat, straight interstate as documented by Sandia, Statistical Description of Heavy Truck Accidents on Representative Segments of Interstate Highway, SAND-0409, January, 1977.

The truck accident rate used in original estimate is 1.1 X 10- 6 /yr.

This new evaluation results in a revision of the expected truck accident rate on I-5 in the region of Units 2/3.

The new accident rate and, therefore, hazard frequency is 39% of the value used in the original estimate. By using this revised truck accident rate, the off-site hazard was obtained as summarized in Table 2.

The off-site hazard is reduced by the presence of a gas monitoring system at Units 2/3.

To assess the impact of this system, an evaluation using the system unavailability is petformed (0.01 is conservatively used based on actual system experience).

The off-site hazard frequency, taking 5

credit for this feature, is shown in Table 3, taking into account both the effects of the gas monitor system and the revised truck accident rate.

C.

Conclusions Based on the results of this 1984 survey and analy sis, it is concluded that the frequency of shipment of hazardous material has not changed signifi cantly.

The 1984 updated off-site hazard frequency is 3.4 X 10-7 /yr.

Compared with the original value of 2.3 X 10-7/yr, the 1984 value represents a slight increase.

It is noted that the evaluation includes significant conservatisms. Since the off site hazard frequency of 3.4 X 10- 7 /yr is signifi cantly below the NRC SRP acceptance criteria, the slight increase is insignificant from a risk per spective.

The degree of actual risk associated with the off-site hazardous cargo shipment is con siderably smaller than that associated with other internal or external events, and does not introduce significant additional risk to the plant.

6

III. EVALUATION OF LONG TERM CHANGES IN OFF-SITE HAZARD PROBABILITIES A.

Introduction In addition to the 1984 evaluation of the frequency of shipment of potentially hazardous cargo and the associated off-site hazard, an evaluation of the future off-site hazard at Units 2/3 has been per formed. This future projection is compared against the SRP acceptance criterion of less than 10- 6 /yr frequency due to the conservatisms inherent in the analyses.

B.

Conservatisms in Evaluation of Off-Site Hazard In the evaluation of the potential for an off-site hazard due to toxic gas, explosive overpressure and flammable vapor cloud, phenomenological uncertain ties have been modeled using conservative assump-.

tions. The conservatisms included in each area are described below.

1.

Toxic Gas Hazard Several effects not considered in the estimate of the likelihood of toxic gas hazard make the results conservative.

These effects include:

a need for the cloud to both rise and fall in order to enter the control room 7

due to the labyrinth type of control room air intake and the effect of possible blockage of the plume by plant structures which would tend to shield the air intake and break up a plume dispersion effects such as ground roughness and terrain which enhance plume dispersion

2.

Explosive Overpressure Exceeding 7 psi The areas of conservatism in the explosive overpressure analysis include:

Structural failure criterion of 7 psi The pressure load capacity of walls and roofs of the seismic category I buildings was determined to be a minimum of 7 psi net governed by the reinforced concrete roof slabs.

It is noted that the analysis was based on energy balance techniques with strain energy capacity limited by flexural ductility ratios not exceeding 3.0 and ultimate load resistance evaluated by yield-line methodology. There is a significant safety margin between violating the ductility limits and failure of safety related structures.

It is thus believed that substantial conservatism exists in the use of 7 psi as the failure criterion 8

for structures. Another factor not con sidered in the deterministic failure criterion is the variation of the struc tural strength. For example, if the failure probability for overpressure at 7 psi is approximately 10-2 and the struc tural strength is log-normally distri buted with a coefficient of variation of 0.10, the failure probability for over pressure at 8 psi is 0.04.

The corre sponding failure probability for over pressure at 9 psi and 10 psi is 0.28 and 0.68 respectively.

This represents a significant conservatism in the analysis.

Puff release An instantaneous puff release of the spilled quantity is assumed.

In a significant number of accidents the spill occurs over an extended time period, thereby reducing the hazard significantly below that of a true puff release.

Flammable quantity of hazardous substance The entire quantity of material released in the puff is assumed to be involved in the explosion leading to possible overpressure. Analysis of a drifting puff release has shown that the maximum quantity between flammable limits is on the order of 60-70% for materials of 9

I interest and that for much of the travel distance, it is less than this amount.

3.

Flammable Cloud at Plant The areas of conservatism in the flammable cloud analysis include:

Area Affected The plant area for which a flammable vapor cloud is unacceptable was conservatively described as a circle with an area more than twice the actual area of safety related buildings.

Air Intake Location The air intakes are located above grade.

Since most vapor clouds of concern will tend to be of very limited vertical extent, it is conservative not to take credit for the air intake being above grade.

Dispersion Modeling The dispersion model conservatively accounts for gravity spreading of the heavier than air vapors without dispersion, followed by atmospheric dispersion using class G stability and a low wind speed.

10

4.

Analysis of Consequences of Accidents The areas of conservatism inherent in the assessment of (assumed) consequences are:

Toxic Gas Hazard Causes Exceedance of 10 CER 100 Exposure Guideline A major consequence of toxic gas at air intake is potential loss of control room habitability.

This does not lead to core melt by itself.

In order to have a core melt accident, a transient must occur, safety systems of the plant must fail, and operators must fail to successfully shut down the plant.

The probability of this occurence is estimated[10] to be on the order of less than 10-3.

Even if core melt does take place, containment will still provide a barrier to release of radioactivity to the outside of the plant.

Overpressure Exceeding 7 psi Causes Exceedance of 10 CFR 100 Exposure Guidelines The possible collapse of safety related structures is the major effect of concern for a possible explosive overpressure exceeding 7 psi.

In order to cause a core melt and subsequent significant 11

release of radioactivity, the collapsed structures must introduce a transient concurrent with the failure of safety systems. The likelihood of these multiple effects is certainly less than the probability of a single effect and is believed to be low for overpressures which just exceed the specified limit.

Flammable Gas at Plant Causes Exceedance of 10 CFR 100 Exposure Guideline In order for the flammable gas to cause damage, it must be ignited. Ignition at the switchyard (nearest I-5) would pro bably cause loss of off-site power.

This is a low frequency occurrence compared to other causes of loss of off-site power and, therefore, would not increase risk appreciably. The probability of a given fire leading to core melt is certainly less than 1.0 and may well be small (0.01 operator fails to put out fire and suc cessfully shutdown).

In addition, the containment has to fail to release a sufficient amount of radioactivity to exceed 10 CFR 100 exposure guidelines.

C.

Long-Term Off-Site Hazard Evaluations Two sets of statistics were'used for the analysis of future trends:

12

First, truck travel data near Units 2/3 for the past seven years were statistically analyzed to predict the frequencies of off site hazards in future years.

Table 4 summarizes the futuze off-site hazard for the period of 1985-2024 based on 1.5% annual growth rate of truck travel frequency identified as a result of statistical analysis of previous data.

The maximum frequency of off-site hazard is 5.7 X 10- 7 /yr, significantly lower than the value of 10-6 /yr as specified in SRP 2.2.3.

Secondly, industry survey and forecasts [3,4) for the growth of chemical and petroleum products were used to predict future off-site hazards. Table 5 summarizes the off-site hazard for.the period of 1985-2024, based on 3.0% annual growth rate of petrochemical products identified in the industry survey.

13

IV.

CONCLUSIONS The results indicate that the frequency of offsite hazard induced accident at the plant is well below 10-6 /year on a conservative analysis basis.

Further, the results indicate that the maximum plant lifetime frequency of offsite hazard is 8.3 X 10-7 /yr, still within the limit of 10-6 /yr specified in SRP 2.2.3.

Based on the results of this work, it is evident that the offsite hazard at Units 2/3 for the next forty years is expected to be within the acceptance criterion of SRP 2.2.3.

In addition, significant margins persist because of considerable conservatisms included to account for phenomological uncertainties.

The 97.5 percentile value is used in the development of future predicted values.

This provides high confidence that the predicted values will not be exceeded.

It is con cluded that the long term offsite hazard represents an insignificant risk to the plant when compared with other accident initiators.

The periodic traffic survey every three years is costly and does not contribute to signi ficant risk reduction.

14

REFERENCES

1.

Sourthern California Edison Company, "Section 2.2 Nearby Industrial, Transportation, and Military Facilities", San Onofre 2&3 FSAR, updated.

2.

Letter from Mr.

R.H. Tindel, "1974-83 Large Truck Involved Accident on 1-5 in San Diego County from the San Diego -

Orange County Line South to Milepost Marker 54.7", April 10, 1984.

3.

Predicasts Forecasts, Published Quarterly by Predicasts, Inc.

4.

Standard & Poor's Industry Surveys "Oil Industry",

Nove. 10, 1983, Vol. 151, No. 43, page 0.57.

15

Tablc 1.

Comparis of 1984 Update and Orig*1 Estimate of Off-site Hazard at Unit 2/3 (Frequency of -Presence of Condition)

MA T.E R [ AD R CENAL VALUK

/YEAR 1934 UPDATE P/YEAR nsol ine I x tn-6 3 x 10 1)i s

I ()i 1 x

8 1.4 X 10 Jet Iuel 5 x 1 1.9 X 10 7

Butane L X 10- 6 2.4 X 10-8

-6

-6 Propane 2 X 10 4.4 X 10 Chl orine I X l0-6 1.8 X 10-6 Ammonia 9 X 107 3.S X 10-6 Explosive Overpressure of 7 psi L.3 X 10 3.0 X 10 Flammable Cloud

-7 at Plant

1.

10

3. 2 X 10 TOTAL
6. 3 X 10-6 1.0 X 10

S1)Table

2.

Compatis 9

oF 1934 Update and Ori-gol Estimate of Of-stto Hazard at Unit 2/3 (Includes Iruck Accident Rate Correction)

AT AL rA.IClINAI, VALUE II/YEAR 1984 UPDATE

  1. /YEAR

-7 inu 3.0 In 1.2 x 10 hiosel Ki 1.2 N 10 8 5.5 X 10 Butane 3.9 X 10 9.4 X 10 Propane 7.8 X 10 1.7 X 10-6 Chlorine 3.9 X 10 7.0 X 10 Ammonia 3.5 X 10 1.4 X 10-6 E: plosive 1.3 \\ 10-7 3.0 \\ 10 Overpressu re OE 7psi Flammable Cloud 1.5 x 10 3.2 X 10 at Plant TOTAL 2.5 X 10-6 4.6 X 10-6 Table 2 is converted from Table 1 by multiplying by a truck accident rate factor of 0.39.

Since the loaded tank truck accident rate was used cor rectly Lin the previous estimate, these numbers remain unchanged.

Compirtson o! 1984 Updatc and Oigial Estimate of Off-Site Hazard at Unit 2/3 ([ncludes Truck.Accident Rate Reduction and Monitor System Effects).

  • ml\\TRrAL RF

[(I1NAL VALUE I//YEAR 1984 UPDATE If/YEAR H)

2. H

.H2 X 10 1)i n1 00 X 10 5 5 X 10 Jet.

icl 10 7

(.4 I

1010 Prono 10 1

X 10 hlo rtn(

2.0 H

)

7.0 X 10 Ammonia 1.8,

1.0 1.4 X 10 Exnlosive 1.3 X 10

/

3.0 X 10' Overpressure of 7psi 9

Flammable Cloud 1.5 X 10 3.2 X 10 at Plant

-7 TOTAL 2.3 x 10 '

3.4 X 10 Table 3 is converted from Table 2 by multiplying monitor system unavailability oF 0.01 for toxic gas hazard.

Values for exploS1 overpressure of 7 psi and Flammable Cloud at Plant remain the so us in Table 2.

j.,

TABLE 4.

1985-2024 OFF-SITE HAZARD BASED ON STATISTICAL ANALYSIS OF PREVIOUS DATA PROBABILITY PER YEAR

  • YEAR 97.5 PERCENTILE 198 3.89 X 10 4.11 X 10' 99.5 4.3b) x 10 2000 4.59 X 10 2005 4.34 X 10' 20LO 5.06 X 10-7 2015 5.32 X 10-7 2020 5.57 X 10 7 2024 5.74 X 10-7 97.5 percentile value indicates that one is 97.5 confident that the actual value is lower than estimated value.

TABLL 5.

1985-2024 OFF-SITE HAZARD AT UNIT 2/3 BASED ON INDUSTRY SURVEY PR(o1BAB 1I TY P)LR YEAR YE ALR 97.5 PERCENTILE 1985 4.28 X I()

3 2 x

(

,/

S00 5.85 X 107 2(005 6.38 X 10 '

2010 6.92 X 10 2015 7.42 X 10 720 7.95 X 10 (024 8.37 X 10'