ML13324A474

From kanterella
Jump to navigation Jump to search
Forwards Evaluation of Cold Shutdown & Accident Mitigation Sys for San Onofre Unit 1. Rept Supports 841017 & 22 Submittals Re Seismic Capability of Certain safety-related Sys
ML13324A474
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 11/03/1984
From: Medford M
Southern California Edison Co
To: Zwolinski J
Office of Nuclear Reactor Regulation
Shared Package
ML13324A475 List:
References
NUDOCS 8411070104
Download: ML13324A474 (1)


Text

Southern California Edison Company P. 0.

BOX BOO 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNIA 91770 M.O. MEDFORD TELEPHONE MANAGER, NUCLEAR LICENSING (213) 572-1749 November 3, 1984 Director, Office of Nuclear Reactor Regulation Attention:

Mr. 3. A. Zwolinski, Chief Operating Reactors Branch No. 5 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket No. 50-206 Evaluation Report for Cold Shutdown and Accident Mitigation Systems San Onofre Nuclear Generating Station Unit 1 By letters dated October 17 and 22, 1984 SCE provided information which addressed the seismic capability of those safety related systems which are not being completely upgraded during the current outage. Provided as an enclosure to this letter is a report which documents in more detail the evaluations of these systems.

If you have any questions or desire additional information, please call me.

Very truly yours, Enclosure 8411070104 841103 PDR ADOCK 05000206 P

PDR