UNITED STATES NUCLEAR REGULATORY COMMISSION o
WASHINGTON, D. C. 20555 November 29, 1988 Docket Nos. 50-361 and 50-362 MEMORANDUM FOR:
George W. Knighton, Director Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects FROM:
D. E. Hickman, Project Manager Project Directorate V Division of Reactor Projects -
- III, IV, V and Special Projects
SUBJECT:
FORTHCOMING MEETING* WITH SOUTHERN CALIFORNIA EDISON COMPANY DATE & TIME:
December 7, 1988; 9:00 a.m. - 4:00 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission 11555 Rockville Pike, Room 10-B-13 Rockville, Maryland 20852 P'URPOSE:
To discuss the reracking of the spent fuel pool at San Onofre Units 2 and 3.
- PARTICIPANTS:
NRC Utility DHickman F. Handy, et al.,
JWermiel GBagchi HAsher DJeng NThompson GDegrassi (BNL)
D. E. Hickman, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects cc:
See next page CONTACT: D. Hickman, NRR (301) 492-1380
- Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy,"
43 Federal Register 28058, 6/28/78.
12050111 Sali29 7>
PDR ADOCK 0500
)
1
(
/}
1
November 29, 1988 Docket Nos. 50-361 and 50-362 MEMORANDUM FOR:
George W. Knighton, Director Project Directorate V Division of Reactor Projects -
- III, IV, V and Special Projects FROM:
D. E. Hickman, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects
SUBJECT:
FORTHCOMING MEETING* WITH SOUTHERN CALIFORNIA EDISON COMPANY DATE & TIME:
December 7, 1988; 9:00 a.m. - 4:00 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission 11555 Rockville Pike, Room 10-B-13 Rockville, Maryland 20852 PURPOSE:
To discuss the reracking of the spent fuel pool at San Onofre Units 2 and 3.
- PARTICIPANTS:
NRC Utility DHickman F. Handy, et al.,
JWermiel GBagchi HAsher DJeng NThompson GDegrassi (BNL) original signed by D. E. Hickman, Project Manager Project Directorate V Division of Reactor Projects -
- III, IV, V and Special Projects cc:
See next page DR DR DEHickman:dr G
ton 11 t1/8 8
1 11 /88 CONTACT: D. Hickman, NRR (301) 492-1380
- Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy,"
43 Federal Register 28058, 6/28/78.
Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Units 2 and 3 cc:
Mr. Gary D. Cotton Mr. Hans Kaspar, Executive Director Senior Vice President Marine Review Committee, Inc.
Engineering and Operations 531 Encinitas Boulevard, Suite 105 San Diego Gas & Electric Company Encinitas, California 92024 101 Ash Street Post Office Box 1831 San Diego, California 92112 Mr. Mark Medford Southern California Edison Company Charles R. Kocher, Esq.
2244 Walnut Grove Avenue James A. Beoletto, Esq..
P. 0. Box 800 Southern California Edison Company Rosemead, California 91770 2244 Walnut Grove Avenue P. 0. Box 800 Mr. Robert G. Lacy Rosemead, California 91770 Manager, Nuclear Department San Diego Gas & Electric Company Orrick, Herrington & Sutcliffe P. 0. Box 1831 ATTN:
David R. Pigott, Esq.
San Diego, California 92112 600 Montgomery Street San Francisco, California 94111 Richard J. Wharton, Esq.
University of San Diego School of Alan R. Watts, Esq.
Law Rourke & Woodruff Environmental Law Clinic 701 S. Parker St. No. 7000 San Diego, California 92110 Orange, California 92668-4702 Charles E. McClung, Jr., Esq.
Attorney at Law Mr. S. McClusky 24012 Calle de la Plaza/Suite 330 Bechtel Power Corporation Laguna Hills, California 92653 P. 0. Box 60860, Terminal Annex Los Angeles, California 90060 Regional Administrator, Region V U.S. Nuclear Regulatory Commission Mr. C. B. Brinkman 1450 Maria Lane/Suite 210 Combustion Engineering, Inc.
Walnut Creek, California 94596 7910 Woodmont Avenue, Suite 1310 Bethesda, Maryland 20814 Resident Inspector, San Onofre NPS c/o U. S. Nuclear Regulatory Commission Mr. Dennis F. Kirsh Post Office Box 4329 U.S. Nuclear Regulatory Commission San Clemente, California 92672 Region V 1450 Maria Lane, Suite 210 Mr. G. DeGrassi Walnut Creek, California 94596 Brookhaven National Laboratory Building #129 Mr. Sherwin Harris Upton, NY 11973 Resource Project Manager Public Utilities Department City of Riverside City Hall 3900 Main Street Riverside, California 92522
4 DISTRIBUTION Docket or Central File NRC & Local PDRs PD5 Reading T. Murley/J. Sniezek D. Crutchfield GHolahan MVirgilio GKnighton DEHickman W. Lanning OGC E. Jordan B. Grimes Receptionist (Building where meeting is being held)
NRC Participants ACRS (10)
GPA/PA V. Wilson L. Thomas M. Johnson (Region V)*
G. Cook, Region V**
JLee