ML13317B273

From kanterella
Jump to navigation Jump to search
Discusess 1990 Steam Generator Insp Rept.Rept Documents Steam Generator Tube Insp & Repairs That Were Completed During Refueling Outage 11 to Comply W/Tech Spec Section 4.16
ML13317B273
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 01/18/1991
From: Kalman G
Office of Nuclear Reactor Regulation
To: Ray H
Southern California Edison Co
References
NUDOCS 9101240304
Download: ML13317B273 (2)


Text

January 18, 1991 Docket No. 50-206 Mr. Harold B. Ray Senior Vice President Southern California Edison Company Irvine Operations Center 23 Parker Street Irvine, California 92718

Dear Mr. Ray:

SUBJECT:

SAN ONOFRE UNIT 1 STEAM GENERATOR TUBE INSPECTION REPORT We have reviewed the report "1990 Steam Generator Inspection Results, San Onofre Unit 1" which was submitted November 29, 1990 by the Southern California Edison Company. The report documents the steam generator tube inspections and repairs that were completed during refueling outage 11 to comply with Technical Specification Section 4.16. Additionally, the report documents results of a visual inspection of wrapper support bars on the secondary side of the steam generators.

Our review concludes that your inspections and repairs are consistent with Technical Specification requirements and industry practice. Accordingly, no further action is required.

Sincerely, Original SIgned By:

George Kalman, Senior Project Manager Project Directorate V

  • 9101240304 910118 Division of Reactor Projects III/IV/V PDR ADOCK 05000206 Office of Nuclear Reactor Regulation Qo PDR__

cc:

See next page DISTRIBUTION Docket FM1e NRC & Local PDRs PD5 Reading BBoger MVirgilio GKalman KWichman DFoster OGC Edordan ACRS (10)

PD5 Gray File RZimmerman, RV

  • See previous concurrence OFC
LA/PD5/DRPW
PM/PD5/DRPW
NRR/EMCB*
D/PD5/ RPW NAME :DFoster
GKalman :sg
KWichman er DATE :/ /%/91
t //8/91
1/18/91 T91 OFFIClAL RECORb COPY v

3 D wt Name: SO1 LTR 2

Ito~

Mr. Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc:

David R. Pigott, Esq.

Mr. Richard J. Kosiba, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street 12440 E. Imperial Highway San Francisco, California 94111 Norwalk, California 90650 Mr. Robert G. Lacy Mr. Phil Johnson Manager, Nuclear Department U.S. Nuclear Regulatory Commission San Diego Gas & Electric Company Region V P. 0. Box 1831 1450 Maria Lane, Suite 210 San Diego, California 92112 Walnut Creek, California 94596 Resident Inspector, San Onofre NPS c/o U.S. Nuclear Regulatory Commission P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente 100 Avenida Presidio San Clemente, California 92672 Chairman, Board of Supervisors County of San Diego 1600 Pacific Highway, Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Mgmt. Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don J. Womeldorf Chief, Environmental Management Branch California Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 (10)