Forwards Responses to NRC Questions Re Seismic re-evaluation of Fuel Storage Bldg,Per SEP Topic III-6.Detailed Model of Structure & Digitized Time Histories Used in Evaluation Encl
ML13317A472
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 12/20/1982
From: Baskin K
Southern California Edison Co
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
TASK-03-06, TASK-3-6, TASK-RR NUDOCS 8212220198
Download: ML13317A472 (14)


Text

Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNIA 91770 K. P. BASKIN December 20, 1982 TELEPHONE MANAGER OF NUCLEAR ENGINEERING, (213) 572-1401 SAFETY, AND LICENSING Director, Office of Nuclear Reactor Regulation Attention: 0. M. Crutchfield, Chief Operating Reactors Branch No. 5 Division of Licensing U. S. Nuclear Regulatory Cdimission Washington, D.C. 20555 Gentlemen:

Subject:

Docket No. 50-206 Fuel Storage Building SEP Topic 111-6 San Onofre Nuclear Generating Station Unit 1 In accordance with our letter dated November 30, 1982, enclosed are ten copies of responses to NRC questions regarding the seismic reevaluation of the Fuel Storage Building. Also included are one copy of the detailed model of the structure and one copy of the digitized time histories used in the evaluation.

If you have any questions on this information please let us know.

Very truly yours, Enclosures P

j2 12 22008B1821220 PDR ADOCK 05000206 P

PDR.

RESPONSE TO NRC STAFF QUESTION ON FUEL STORAGE BUILDING NONLINEAR ANALYSIS NOVEMBER 1982 SAN ONOFRE NUCLEAR GENERATING STATION UNIT 1

QUESTION 1 In considering soil structure interaction, how were the soil springs And damping ratios distributed at the--itchgear room wall footing' REPONSE_

~--

The soil asprings for the switchgear room wall were calculated based on the footing length tributary -to each nQde. The locations of the nodes and the values of the soil springs are shown in Table 4.1 of Reference 1. The values for the soil springs were calculated by Woodward-Clyde Consultants in accordance with Reference

2.

The details of procedures are given in Reference S.

2

QUESTION 2 How was the foundation slab at Elevation 14'-0" odelled in the three-dimen sional seismic analysis model?

RESP ONSE This slab was cast on grade and has no structural cornnection to the masonry walls or the fuel pool.

Therefore, the slab was not included in the three dimensional seismic analysis model.

3

QUESTION 3 What is the definition of the "effective length" of wall in the derivation of the out-of-plane masonry wall properties?

RESPONSE

The effective length is half the distance to the next beam or crosswall to either side of the beam in questiQn. The effective length is therefore merely the tributary length, as shown in Figure 3.1.

4

QUESTION 4 Horizontal and vertical analyses were separately performed, and the response-time histories were then combined. Justify the validity of this approach because both analyses were -non-linear-time history analyses.

RESPONSE

The lateral and vertical load resisting components of this building are separate.

The steel framing and columns resist the vertical load while the masonry walls resist the lateral loads. The vertical load resisting system-remains elastic.

Since there is little interaction between these two systems, separate analyses are justified. However, in the most current analyses (Reference 1) all three spatial components were applied simultaneously to the same model.

Therefore this question is no longer applicable.

5

QUESTION 5 Was the linear, elastic model developed for the frequency extraction only, and not for any response analysis?

RESPONSE

The linear global model was used only for initial parametric studies and for modal extraction. The linear global model was not used for any component evaluation.

6

QUESTION 6 Your conclusions stated that "The 'as-built' structure was subjected to earthquake motions of the specified DBE level of 0.67g Housner for San Onofre Unit 1 and complied.with the-structural integrity acceptance criteria under.this load.". It is our understanding that only the El Centro records were used in a structural integrity evaluation of the building while Fig. '.2 indicate that-the El Centro records do not envelop the 0.67g Housner spectra.

Provide your justification of the accuracy of aforementioned conclusion statement.

Our particular concers are with the wall FB-7 and roof connections to walls FB-6 and FB-7.

RESPONSE

Since Reference 3 was transmitted to the NRC, wall FB-7 and the roof con-nections to walls FB-6 and FB-7 have all been upgraded. In addition, the analysis presented f.-in Reference 1 has been performed.

In the more current analysis all three components of the three real time histories were frequency scaled so that they envelope the appropriate response spectrum. The appropriate response spectra are defined in Reference 4. Considering the recent analysis and the modifications to the structure itself since the writing of this question, the structure has been shown to be adequate.

7

QUESTION 7 Provide information on the reevaluation of the foundation, which is not currently included in Ref. 7.

RESPONSE

The current analysis, referred to in the question, is the analyses presented in Reference 3. Since the time this question was posed the analysis presented in Reference I has been performed. The results for this analysis reported in Reference 1 also address the foundation analysis.

These results are presented in Section 7.1 of Reference 1 and in summary predict that the Fuel Pool basemat (between 4'-9" and 5'-9" thick) would not even crack under DBE loading.

8

QUESTION 8 Provide digitized records of all components of all time histories used in the analysis.

RESPONSE

Digitized records of all nine components of the three earthquakes used in the analysis are attached to this enclosure. The 8192 entries for each component are in g's and are digitized at a period of.005 seconds.

9

QUESTION 9 Provide references used as a basis for the in-plane Strain criteria for masonry walls.

RESPONSE.

The in-plane strain criteria are based on Reference 6, a copy of which is enclosed.

10

QUESTION 10 Provide details of the structural model for the Fuel Storage Building and the associated soil structure interaction parameters used in the Model.

RESPONSE

A copy of the ANSR II Program echo print of the model is enclosed. Also enclosed are computer plots showing the nodes and those portions of the ANSR II Program User's Manual relevant to the model.

11

REFERENCES 1..

Computech Engineering Services, Inc., "Seismic Reevaluation of Reinforced Concrete Masonry Walls", Volume 5:

Fuel St fate Building Sol1 Backfill Condition Evaluation",

San eofre -NuclearGen rting St on-Uni 1, Report No. 534-02, September 1982; (transmitted n letter from

.P Baskib to D.M.

Crutchfield, dated September 30, 1982, SSEP I-6 Fuel Storage Building).

2.

Woodward-Clyde Consultants, Balance of Plant (BOP) SONGS Unit 1 Soil Structure Interaction Methodology Report, Revision 1, Orange, California, July 1978.

3.

Computech Engineering Services, Inc., "Seismic.Reevaluation of Reinforced Concrete Masonry Walls", Volume 4:

Fuel Storage Building", San Onofre Nuclear Generating Station Unit 1, Report No. 534-02, April 1982; (transmitted in letter from K.P. Baskin to D.M. Crutchfield, dated April 30, 1982,

Subject:

SEP Topic 111-6, Seismic Design Considerations).

4.

Letter from W. Paulson to R. Dietch,

Subject:

SEP Topics 11-4.A and 11-4.C.

Free Field Ground Motions to be used in the Seismic Reevaluation of San Onofre Nuclear Generating Station, Unit 1 (SONGS-1) dated September 16, 1982.

5.

Enclosure to letter from K. P. Baskin to D. M. Crutchfield

Subject:

Response

to Open Items, SEP Topic 111-6, dated September, 15, 1982.

6.

Chen, Shy-Wen J. et al., Cyclic Loading Tests of Masonry Single Piers, Volume 2 -

Height to Width Ratio of 1, Earthquake Engineering Research Center, University of California, Berkely, California, December 1978.