Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CALIFORNIA 91770 K. P. BASKIN TELEPHONE MANAGER OF NUCLEAR ENGINEERING, August 9, 1982 (213) 572.1401 SAFETY, AND LICENSING Director, Office of Nuclear Reactor Regulation Attention:

D. M. Crutchfield, Chief Operating Reactors Branch No. 5 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket No. 50-206 Free Field Ground Motibn San Onofre Nuclear Generating Station Unit 1 By letter dated June 29, 1982 we provided information regarding the appropriate free field ground motion for the seismic reevaluation of San Onofre Unit 1. In subsequent telephone discussions with the NRC Staff, additional information was requested. This additional information was discussed with the NRC Staff in a meeting on August 4, 1982. The purpose of this letter is to document that information.

Provided as an enclosure to this letter are responses to specific items of interest raised by the NRC Staff in telephone conversations or at the August 4, meeting. Also included is a summary of the ground motion studies performed for the San Onofre site.

If you have any questions regarding any of this information please let me know.

Very truly yours, Enclosure 8208120106 820809 PDR -ADOCK 05000206 P

PDR

Enclosure RESPONSES TO SPECIFIC ITEMS OF INTEREST PERTAINING TO GROUND MOTION STUDIES FOR SAN ONOFRE UNIT 1 Summary of Ground Motions, San Onofre Nuclear Generating Site Response to Questions on WCC Report, Development of Instrumental Response Spectra for the San Onofre Site, June 1982 Response to NRC Questions on TERA Report, Estimation of Selected Response Spectral Values at the San Onofre Nuclear Generating Station, June 1982 Review of Joyner and Boore, 1982 Supplemental Analysis of Dispersion for the 1975 Oroville and the 1979 Imperial Valley Aftershock Data, August 7, 1982 Literature Survey and Development of Strong-Motion Duration for Designs at the SONGS Site, August 6, 1982 Clarification of Comparison Between TERA Results and Joyner-Boore 1982