ML13316B882

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 880308-11.Violation Noted: Independent Audit of Emergency Preparedness Program Not Performed Since 861201
ML13316B882
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 04/01/1988
From: Wenslawski F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML13316B881 List:
References
50-206-88-07, 50-206-88-7, 50-361-88-07, 50-361-88-7, 50-362-88-07, 50-362-88-7, NUDOCS 8804190132
Download: ML13316B882 (1)


Text

APPENDIX A NOTICE OF VIOLATION Southern California Edison Company Docket Nos. 50-206, 50-361 P. 0. Box 800 and 50-362 2244 Walnut Grove Avenue License Nos. DPR-13, NPF-10 Rosemead, California 91770 and NPF-15 As a result of the inspection conducted during the period March 8-11, 1988, and in accordance with NRC Enforcement Policy, 10 CFR Part 2, Appendix C, the following violation was identified:

10 CFR 50.54(t) states in part, "the licensee shall provide for a review of its emergency preparedness program at least every 12 months by persons who have no direct responsibility for implementation of the emergency preparedness program".

Contrary to this requirement, as of March 11, 1988, an independent audit of the emergency preparedness program had not been performed since December 1, 1986.

No response to this violation is required in view of the corrective action initiated and documented in inspection report Nos. 50-206/88-07, 50-361/88-07, and 50-362/88-07.

This is a Severity Level V violation (Supplement VIII).

Dated F. A. Wenslawski, Chief Emergency Preparedness and Radiological Protection Branch 8e04190132 880401 PDR ADOCK 05000206 Q

DC:D