Text

Southern California Edison Company P.O. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD CALIFORNIA 91770 July 22, 1980 U. S. Nuclear Regulatory Cmmission Office of Inspection and Enforcement Region V 1990 North California Boulevard Suite 202, Walnut Creek Plaza Walnut Creek, California. 94596 Attention:

Mr. R. H. Engelken, Director DOCKET No. 50-206 SAN ONOFRE -

UNIT 1

Dear Sir:

IE BULLETIN 80-16 POTENTIAL MISAPPLICATION OF ROSEMOUNT INC. MODELS 1151 AND 1152 PRESSURE TRANSMITTERS WITH EITHER "A" OR "D" OUTPUT CODES Reference is made to your correspondence of June 27, 1980, which forwarded the subjectIE Bulletin.

This bulletin identified potential deficiencies in Bosemount Inc. Models 1151 and 1152 pressure transmitters.

In response to the action requested by the bulletin, we have determined that no Rosemount Inc. Model 1151 or 1152 pressure transmitters with output codes "A" or "D" are used or planned to be used in any safety-related ap plication at San Onofre Unit 1. Therefore the analysis and description of corrective action requested in action items 2 and 3 are not applicable.

In accordance with your request in the cover letter to the subject bulletin we have estimated that 18 man-hours of work were required to complete the report required by the subject bulletin.

No man hours were required for corrective action.

If you have any questions or require additional information concerning this response, please contact me.

Sincerely, H. L. Ottoson Manager of Nuclear Operations cc: Director, Office of Inspection and Enforcement 800828(0 0

,Q

Mr. R. H. Engelken Page 2 WWS/WGF:n9 bcc: Ibbert Dietch A. Arenal H. L. Ottoson J. M. Curran B. L. Curtis/M. A. Wharton C. R. Kocher/J. A. Beoletto K. P. Baskin D. E. Nunn J. G. Haynes W. C. Moody/R. W. Krieger D. R. Pigott, esq. (Chickering & Gregory)

W. W. Gilman (SDG&E)

R. L. Erickson (SDG&E)

B. Katz/W.W. Strom C. K. Balog R. Ornelas EDM Files