Jump to navigation Jump to search
Part 21 Rept Re Defect Condition on Reactor Coolant Pump Seal Housing Supplied to Nuclear Power Facilities.Defect Manifested by Failure of Seal to Stage.Visual Exam of Remaining Four Assemblies Performed to Assure Acceptance
ML13316A066
Person / Time
Site: San Onofre, Calvert Cliffs  Southern California Edison icon.png
Issue date: 09/10/1990
From: Thomas W
SULZER BINGHAM PUMPS, INC.
To:
NRC
References
REF-PT21-90 NUDOCS 9011080263
Download: ML13316A066 (1)


Text

SULZER BINGHAM 2800 N.W Front Ave.

  • RO Box 10247
  • FAX (503) 226-5286
  • ITT 4742014 September 10, 1990 U.S. Nuclear Regulatory Commission Vendor Program Branch Washington, D.C. 20555

Dear Sir or Madam:

Per the requirements of 10CFR Part 21, Sulzer Bingham Pumps Inc. advises of a defect condition on a Reactor Coolant Pump Seal Housing supplied to Baltimore Gas & Electric Company's Calvert Cliffs Units 1 and 2.

The condition was first observed on Unit 1, Pump 12A upon seal pressurization prior to start-up. The defect is manifested by failure of this seal to stage. This does not constitute total seal failure.

SBPI evaluation has identified the defect as a mis-drilled hole. Visual examination of the remaining four assemblies in Unit 2 will be performed at Calvert Cliffs to assure acceptance. Verification of the other three Unit 1 RCP Seal Housings at Baltimore Gas & Electric has been by proper seal staging and function.

Similar housings are installed at Southern California Edison's San Onofre Units 2 and 3 and showed no signs of deficiency upon start-up in the years past, but an information letter will be sent concurrently with the one going to Baltimore Gas &

Electric.

Yours truly, Wayne D. Thomas Director, Corporate Quality cc: R. L. Ayers G. D. Halas T. W. McAfee P. L. McCullough T. R. Morton S. M. Nelson S. Pace G. J. Parks J. Wood NRC File WDTO9-04:cg 9011080263 900910 a 9 PDR ADOCK 05000206 PNu