ML13312A663

From kanterella
Jump to navigation Jump to search
Annual Personnel Monitoring Rept - 1992,San Onofre Nuclear Generating Station,Units 1,2 & 3
ML13312A663
Person / Time
Site: San Onofre  
Issue date: 12/31/1992
From:
Southern California Edison Co
To:
Shared Package
ML13312A662 List:
References
NUDOCS 9303090429
Download: ML13312A663 (2)


Text

Regulatory Guide 1.16 Statistical Summary for 1992 TOTAL NBR OF INDIVIDUALS RECEIVING GREATER THAN 100 MREM 780

SUMMARY

DPR-13, NPF-10, NPF-15 NUMBER OF WORKERS EXPOSURE (PERSON REM)

STATION UTILITY OTHERS STATION UTILITY OTHERS RX OPS & SURY MAIN 20 5

9 0.652 0.035 0.082 OPS.

6 1

0 0.117 0.015 0.000 H.P.

17 0

9 1.165 0.000 0.583 SUPV 2

0 1

0.320 0.000 0.013 ENGR 13 2

9 0.733 0.089 0.281 ROUTINE MAINT MAIN 70 14 202 6.511 1.404 21.764 OPS.

31 11 1

6.653 3.266 0.431 H.P.

55 2

179 14.008 0.441 37.960 SUPV 4

0 2

0.465 0.000 0.013 ENGR 31 4

27 3.610 0.254 2.830 INSERVICE INSP MAIN 17 3

75 0.193 0.078 19.196 OPS.

0 0

0 0.000 0.000 0.000 H.P.

2 0

1 0.053 0.000 0.001 SUPV 0

0 0

0.000 0.000 0.000 ENGR 15 2

15 0.725 0.219 3.729 SPECIAL MAINT MAIN 56 13 188 11.595 4.824 36.172 OPS.

5 5

0 0.069 0.066 0.000 H.P.

32 0

104 2.100 0.000 6.658 SUPV 3

0 3

0.522 0.000 0.693 ENGR 23 2

33 4.059 0.018 8.051 WASTE PROCESSING MAIN 5

1 18 0.016 0.000 0.522 OPS.

0 0

0 0.000 0.000 0.000 H.P.

26 2

110 5.876 0.483 31.875 SUPV 0

0 0

0.000 0.000 0.000 ENGR 2

0 2

0.025 0.000 0.090 REFUELING MAIN 33 2

97 9.598 0.005 30.007 OPS.

1 1

0 0.126 0.004 0.000 H.P.

11 1

35 0.586 0.009 2.610 SUPV 0

0 2

0.000 0.000 0.102 ENGR 13 2

8 4.214 0.119 2.031 TOTAL MAIN 86 14 291 28.569 6.349 107.745 OPS.

32 11 1

6.967 3.353 0.431 H.P.

55 2

184 23.792 0.934 79.691 SUPV 4

0 4

1.308 0.000 0.822 ENGR 37 5

54 13.369 0.702 17.014 GRAND TOTALS 214 32 534 74.005 11.338 205.703 TOT I OF INDIVIDUALS RECEIVING GREATER THAN 500 MREM IN A SINGLE EXPOSURE 18 Note:

The TOTAL fields are not a summation of the Worker and Exposure breakdowns by Job Function, since:

Workers may be entered in more than one job function but are only counted once in the total.

(e.g. A Maintenance worker may work on a refueling job and a routine maintenance job and is therefore counted in both job functions; however, he/she is only counted once in the maintenace Total)

Exposure is calculated from pocket dosimeter dose for each worker on each job.

Pocket dosimeter readings are used to ratio and distribute the measured TLD doses into the above exposure columns.

9303090429 930301 PDR ADOCK 05000206 R

PDR

PERSONNEL WHOLE BODY EXPOSURES FOR CALENDAR YEAR 1992 LICENSEE REPORTING (NAME & ADDRESS)

LICENSE NO.

SOUTHERN CALIFORNIA EDISON COMPANY DPR-13, NPF-10, NPF-15 SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

P.O. BOX 128 SAN CLEMENTE, CA. 92674-0128 ANNUAL DOSE RANGES*

NUMBER OF INDIVIDUALS (REM)

IN EACH RANGE NO MEASURABLE EXPOSURE 2148 MEASURABLE EXPOSURE LESS THAN 0.10 871 0.10 -

0.25 308 0.25 -

0.50 258 0.50 -

0.75 156 0.75 -

1.0 51 1.0 2.0 7

2.0 3.0 0

3.0 4.0 0

4.0 5.0 0

5.0 6.0 0

6.0 7.0 0

7.0 8.0 0

8.0 9.0 0

9.0 10.0 0

10.0 11.0 0

11.0 -

12.0 0

12+

0 TOTAL NBR OF INDIVIDUALS REPORTED 3799 TOTAL MAN-REM 324.289 THIS REPORT IS SUBMITTED IN ACCORDANCE WITH 10CFR20.407(a)(1).

  • INDIVIDUAL VALUES EXACTLY EQUAL TO THE VALUES SEPARATING EXPOSURE RANGES SHALL BE REPORTED IN THE HIGHER RANGE.