AC40 - RA NRC MONTHLY OPERATING REPORT 6
DOCKET NO.
50-206 DATE COMPLETED BY R.
oran TELEPHONE (714)492-7700 OPERATING STATUS
- 1. UnitName:
San Onofre Nuclear Generating Station-Unit 1
- 2. Reporting Period:
October 1, 1979 to October 31. 1979
- 3. Licensed Thermal Power (MWt):
1347
- 4. Nameplate Rating (Gross MWe):
46
- 5. Design Electrical Rating (Net MWe):
- 6. Maximum Dependable Capacity (Gross MWe):
4 6
- 7. Maximum Dependable Capacity (Net MWe):
436
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give-Reasons:
N.A.
- 9. Power Level To Which Restricted, If Any (Net MWe):
N.A.
- 10. Reasons For Restrictions, If Any:
N.A.
This Month Yr.-to-Date Cumulative 745 7,296 108,512.30
- 11. Hours In Reporting Period 745 6,20 108,31.0
- 12. Number Of Hours Reactor Was Critical 745_6,585.20_1.,30-
._OT
- 13. Reactor Reserve Shutdown Hours
/4b b73.88 77,821.-3T
- 14. Hours Generator On-Line U
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (MWH) 993,802 8,729,026 99,802,294
- 17. Gross Electrical Energy Generated (MWH) 331,200 2,932,200 34,083,434
- 18. Net Electrical Energy Generated (MWH) 317,571 2,1792,283 32.284.118
- 19. Unit Service Factor 100.00 90.10 74.31
- 20. Unit Availability Factor 100.00 90.10 74.31
- 21. Unit Capacity Factor (Using MDC Net) 97.77 87.87 72.72
- 22. Unit Capacity Factor (Using DER Net) 97.77 87.87 72.72
- 23. Unit Forced Outage Rate 0
4.64 9.28
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
TMI -
Backfit January 1980 - 2 weeks Refueling April 1980 - 6 weeks
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
N.A.
- 26. Units In Test Status (Prior to Commercial Operation):
N.A.
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
,CE PSSO(I) 371 NEW 8/78 7911140
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-206 UNIT SONGS-1 DATE 11-7-79 COMPLETED BY R. G. Moran TELEPHONE (714) 492-7700 MONTH October DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 432 429 17 2
431 427 3
431 19 425 4
432 20 424 5
432
.21 424 6
431 22 424 7
429 23 416 8
427 24 407 9
428 25 431 10 428 26 433 11 431 27 434 12 430 28 432 13 401 29 434 14 374 30 436 15 430 31 435 16 4313_
PSSO(i) 371 NEW 8/78
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
SUNGS-2 UNIT NAME DATE 11-7-79 COMPLETED BY R.G. Moran REPORT MONTH OCTOBER TELEPHONE (714) 492-7700 r j Licensee Ew Cause & Corrective Do Jate Event 72Action to Reor It E C, Report Prevent Recurrence 28 10-13-79 S
10.1 B
4 N.A.
HB VALVEX TURBINE STOP VALVE TEST HC HT EXCH CONDENSER CLEANING 29 10-23-79 S
5.7 B
4 N.A.
HB VALVEX TURBINE STOP VALVE TEST HC HT EXCH CONDENSER CLEANING
'30 10-24-79 F
0.5 G
4 N.A.
HC HT EXCH DECREASING CONDENSER VACUUM FROM OPEN INTERTIE BETWEEN CONDENSER AND HOT WELL 3
4 F: Forced Reason:
Method:
Exhibit F - Instructions S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram.
Entry Sheets for Licensee C-Refueling 3-Automatic Scram.
Event Report (LER) File (NUREG D-Regulatory Restriction 4-Other (Explain) 0161)
E-Operator Training & License Examination F-Administrat ive G-Operational Error (Explain)
Exhibit H-Sainc Source I-Otlici (Explain)
Psso(l) 371 NEW 8/78
SUMMARY
OF OPERATING EXPERIENCE FOR THE MONTH DOCKET NO.
50-206 UNIT SONGS-1 DATE 11-7-79 COMPLETED BY R.G. MORAN TELEPHONE (714) 492-7700 At the beginning of the month the unit was operating at 452 MWe gross.
On October 13, at 2126, the unit load was reduced to 220 MWe for a turbine stop valve test and condenser cleaning. Unit load was returned on October 14, at 0730.
On October 23, at 2220, the unit load was reduced to 320 MWe for a turbine stop valve test and condenser cleaning. On October 24, at 0110, the unit load was reduced to 130 MWe due to decreasing condenser vacuum from an open intertie between the condenser and hotwell.
Unit load was returned to 320 MWe at 0140. Unit load was returned to full load on October 24, at 0430.
Pssola) 371 NEW 8/78
REFUELING INFORMATION DOCKET NO.
50-206 UNIT SONGS 1 DATE 11-7-79 COMPLETED BY R. G. Moran TELEPHONE (714) 492-7700
- 1. Scheduled date for next refueling shutdown.
April 1980
- 2. Scheduled date for.restart following refueling.
May 1980
- 3. Will refueling or resumption of operation thereafter require a Technical Specification change or other license amendment?
No changes expected at this date.
What will these be?
N.A.
- 4. Scheduled date for submitting proposed licensing action and supporting information.
N.A.
- 5. Important licensing considerations associated withrefueling, e.g.
new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design, new operating procedures.
None
- 6. The number of fuel assemblies.
a) In the core 157 b) In the spent fuel storage pool.
58
- 7. Licensed spent fuel storage capacity.
216 Intended change in spent fuel storage capacity.
None
- 8. Projected date of last refueling that can be discharged to spent fuel storage pool assuming present capacity.
January 1983 PSso(1)371 NEW8/78