E C Ei V ED NRC REGION V Southern California Edison CorgypiEC -6 Ali 9: 52 SAN ONOFRE NUCLEAR GENERATING STATION P.O. BOX 128 SAN CLEMENTE, CALIFORNIA 92674-0128 R. W. KRIEGER TELEPHONE STATION MANAGER (714) 368-6255 December 2, 1991 Mr. John B. Martin Regional Administrator U. S. Nuclear Regulatory Commission, Region V 1450 Maria Lane, Suite 210 Walnut'Creek, California 94596

Subject:

Docket No. 50-206 Reactor Coolant Pump Motor Flywheel Inspections San Onofre Nuclear Generating Station, Unit 1

References:

1.) Letter, R. W. Krieger (SCE) to J. B. Martin (USNRC-RV),

dated October 26, 1991

2)

Letter, R. P. Zimmerman (USNRC-RV) to R. W. Krieger (SCE), dated October 30, 1991 Reference 1 documented Southern California Edison's (SCE) request for a temporary waiver of compliance to defer shutdown of Units 1 and 3 to perform Reactor Coolant Pump (RCP) motor flywheel inspections. Reference 2 documents NRC approval of SCE's waiver request.

Unit 1 was subsequently shutdown on November 16, 1991 and the three RCP motor flywheels were satisfactorily inspected.

The inspections were completed on November 18, 1991.

Inspection of the Unit 3 flywheels have not been performed and are the subject of separate correspondence.

If you have any questions or comments, or if you would like additional information, please let me know.

erel y, cc:

R. P. Zimmerman, USNRC, Region V C. W. Caldwell, USNRC Senior Resident Inspector J. 0. Bradfute, USNRC Project Manager, Unit 1 J.

76*'/

J