ML13308B726

From kanterella
Jump to navigation Jump to search
Forwards Preliminary Rept on Geologic Drilling & Investigation,San Onofre Nuclear Generating Station Units 2 & 3 & 61 Geophysical Maps (Interpretations) Prepared by Pj Fischer of CA State Univ Encl
ML13308B726
Person / Time
Site: San Onofre  
Issue date: 06/27/1980
From: Baskin K
Southern California Edison Co
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML13308B727 List:
References
NUDOCS 8007010358
Download: ML13308B726 (2)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8007010358 DOC.DATE: 80/06/27 NOTARIZED: NO 0OCKET #

FACIL:50-361 San Onofre Nuclear Station, Unit 2, Southern Californ 05000361 32 n Onofre Nuclear Station, Unit 3, Southern Californ 05000362 AUT AUTHOR AFFILIATIuN BASKIN,K.P.

Southern California Edison Co.

RECIP.NAME RECIPIENT AFFILIATION SCHeENCER,A.

Licensing Branch 2

SUBJECT:

Forwards "Preliminary Rept on Geologic Drilling &

InvestigationSan Onofre Nuclear Generating Station Units 2 & 3 & 61 geoohysical maps (interpretations) prepared by PJ Fischer of CA State Univ encl, DISTRIHUTION CODE: 8001S COPIES RECEIVED:LTR _L ENCL L SIZE:J TITLE: PSAR/FSAR ANIDTS and Related Correspondence 1<55P OF ENL Fo R F/L/MAV (REURA)

To RCG F/L JTP RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL ACTION:

AD AOP L/c6NsHG 1

)

C 5CHrtEwr-cv1A 1

LA L6EJ.

1 PM foob,/f.

05 1

INTERNAL:

A/D CORE & CS13 1

ACCID EVAL BR 1

AUX SYS BR 18 1

CHEM ENG BR 1

CONT SYS BR 1

CORE PERF BR 17 1

DIRECTOR NRR 1

EFF TR SYS BR I

EMERG PREP 22 1

ENV ENG 8R I

E(JUIP QUAL BR 1

GEOSCIEN BR 09 4

HANAUER,S.

1 HYD/GEO BR 11 1

IRC SYS 3R 20 1

I&E 06 3

KIRKWOOD,R.

29 1

MATL ENG BR 1

MECH ENG BR 1

MPA 1

NRC PDR 02 1

1 OELD 1

POWER SYS BR 1

1 PROC/TST REV BR 1

QA BR 10 1

1 RZ-4A§,S 8R12 1

REAC SYS BkR 1

1 FL 01 1

SIT ANAL BR 27 1

1 STRTCT=E7 BR 1

EXTERNAL: ACRS 30 10 1

LPDR 03 1

NSIC 04 1

JUL T U F S RTL TOTAL NUMBER OF COPIES REQUIRED: LTTR 51 ENCL 9

Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNIA 91770 K. P. BASKIN TELEPHONE MANAGER, NUCLEAR ENGINEERING June 27, 1980 (213) 572-1401 AND LICENSING Director, Office of Nuclear Reactor Regulation Attention:

Mr. Albert Schwencer, Acting Branch Chief Licensing Projects Branch 3 U.S..Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 San Onofre Nuclear Generating Station Units 2 and 3 SCE's letter of May 12, 1980, forwarded seven copies of "Offshore Geophysical Maps" (interpretations) prepared by Dr. P. J. Fischer of California State University at Northridge. The information upon which Dr. P. J. Fischer based his interpretations has subsequently become available to SCE and is enclosed (NRC mail code B024). Also enclosed are seven copies of logs of two onshore borings (NRC mail code B024), located on El Camino Real approximately 500 feet northeast of the Cristianitos fault. These borings were performed to reaffirm the Applicants previous assessment which was transmitted to the NRC on June 11, 1980, relative to the offset of the Cristianitos fault.

If you have any questions or comments concerning this information, please contact me.

Very truly yours, Enclosure S

LEME-k cc:

USGS, Menlo Park, CA (Dr. J. Andrews)

USGS, Reston, VA (J. F. DeVine)

California Division of Mines and Geology (P. Amimoto)

D. B. Slemmons 00o10o1 O3'