Ro:On 770426,north Boric Acid Transfer Pump Failed to Start. Probably Caused by Accumulation of Boric Acid Crystals.Pump Lagging & Heat Tracing Circuits Examined.Operating Procedures Revised.Addl Lagging Added.Spare Pump Installed
ML13308B462
Person / Time
Site: San Onofre 
Issue date: 05/25/1977
From: Head J
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 8103050997
Download: ML13308B462 (1)


Text

Southern California Edison Company P. 0. BOX Soo

.2244 WALNUT GROVEAVENUE 9:1 J.T. HEAD, JR.

ROSEMEAD, CALIFORNIA9 O

TELEPHONE VICE PRESIDENT May213-572-1472 U. S. Nuclear Regulatory Commisssion Region V Office of Inspection and Enforcement Suite 202, Walnut Creek Plaza 1990 North California Boulevard Walnut Creek, California 94596 Docket No. 50-206 an,Qngfre Unit1 Attention: R. H. Engelken, Director REG&

~

l~l

Dear Sir:

This letter describes a reportable occurrance involving the Chemical and Volume Control System. Submittal is in accordance with the reporting requirement stipulated in Section 6.9.2.b(2) of the Technical Specifications.

On April 26, 1977, the north boric acid transfer pump failed to start.

Corrective action was initiated; a spare pump was installed and placed in service April 27, 1977. During the period that the north boric acid transfer pump was out of service, both the boric acid injection pump and the south boric acid transfer pump were available and the conditions of Technical Specification 3.2.B(2) were, therefore, satisfied.

Investigation revealed an accumulation of boric acid crystals in the failed pump. The pump lagging and heat tracing circuits were examined. Operating procedures were reviewed. No specific cause for the failure could be positively determined. However, to afford greater protection from potential development of isolated cold areas, additional lagging was added in the vicinity of the pump and adjacent piping.

If you should require additional information concerning this occurrence, please contact me.

Sincerely,

Attachment:

Licensee Event Report 77-06 5

cc: Director, Office of Inspection & Enforcement Director, Office of Management Information & Program Control 9(036 S-6q7l