RO 77-09:on 770729,Westinghouse Recommended Reduction in Max Pressurizer Heatup Rate.Caused by Recent Westinghouse Analyses Revealing That Heatup Rates in Excess of 100 F/Hr Inconsistent W/Original Pressurizer Specs
ML13308B454
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 08/22/1977
From: Curran J
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
RO-77-09, RO-77-9, NUDOCS 8103050961
Download: ML13308B454 (3)


Text

LICENSEE EVENT REPORT LER (77-09)

COROL BLOCK:

(PLEASE PRINT ALL REQUIRED INFORMATION]

1 6

LICENSEE LICENSE EVENT NAME LICENSE NUMBER TYPE TYPE 0 lcA O

S101s I 0

- 10,0101 001-101 0l 41 1 1 1 011 7

89 14 15 25 26 30 31 32 REPORT REPORT CATEGORY TYPE SOURCE DOCKET NUMBER -

EVENT DATE REPORT DATE lyCON'T [ P i0 TJ L J 1 01 51011- 0 121 01 61 101 71219-17 171 I 018 12 1217 1 7

8 57 58 59 60 61 68 69 74 - 75 80 EVENT DESCRIPTION 0 Westinghouse Electric Corporation recommended to Southern California 7

8 9 3 I Edison by letter dated July 29, 1977, that the maximum pressurizer 7

8 9 o80 4 I heat-up rate should be reduced from 200oF/hr.An Operating history showeo 7

89 60 05 I that all pressurizer heat-ups at San Onofre have been at rates consid erably less than 100 F/hr. The necessity for changes to the Technical 60 7

89 Specifications is under invesggation (71-22).

80 SYSTEM CAUSE COMPONENT COMPONENT CODE CODE COMPONENT CODE SUPPUER MANUFACTURER VIOLATION 07 LCA.J LBJ Ivi EISISI EILI INI IW 11 120l1 J

78910 11 12 17 43 44 47 48 CAUSE DESCRIPTION 0 [Recent analyses by Westinghouse revealed that pressurizer heat-up rates in excess of 7

89 09 I 1000 F,/hr for all oDerating Westinghouse plants are not consistent with original 7

89 10 I pressurizer specifications.

7 8 9 6

FACILITY METHOD OF STATUS

% POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION M1 L EI I 10 101 I NA I Ldj I Letter from Westinghouse 7

8 9

10 12 13 44 45 46 80 FORM OF ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE 12

[J Z

NA I

NA 7

8 9

.10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION 1 0 1 01 01 [Z I NA

1.

7 8 9 11 12 13 80 PERSONNEL INJURIES 4

0NUMBER DESCRIPTION 1

0 1 01l 01 1NA 7

8 9 11 12 80 OFFSITE CONSEQUENCES 15 NA 7

89 LOSS OR DAMAGE TO FACILITY TYPE DESCRIPTION 16 z

I NA 7

8 9 10A 80 PUBLICITY 17 l

NA 7

8 9 80 ADDITIONAL FACTORS 80, 18 I

191 7

89 NA PHONE: 714 492 7700 so

/

OT

/

40*-1);

JGP0 881* 667

REGILATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

DISTRIBUTION FOR INCOMING MATERIAL 50-206 REC:

ENGELKEN R H ORG:

HEAD J T DOCDATE:

08/25/77 NRC S CA EDISON DATE RCVD:

02/22/78 DOCTYPE:

LETTER NOTARIZED.

NO COPIES RECEIVED

SUBJECT:

LTR 1 ENCL. I LICENSEE EVENT REPT.

NO.

50-206/77-09 CONCERNING PRESSURIZER HEAT--UP RATES IN EXCESS OF 100 DEGREES F/HR....

PLANT NAME:SAN ONOFRE -

UNIT 1 REVIEWER INITIAL:

XRL DISTRIBUTOR INITIAL:

      • ++****+**+****

DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS *+*+ ++++*+++

LER (BACKFIT)

(DISTRIBUTION COD INTERNAL:

EG FILE *W NRC PDR**W/ENCL I

F

/2 ENCL EXTERNAL:

LPDR 'S MISSION VIEJO, CA **W/ENCL REGION V**W/ENCL TIC**W/ENCL ACRS CAT B**W/O ENCL DISTRIBUTION:

LTR 7 ENCL 7 CONTROL NBR:

4Q99 SIZE:

IP+IP THE END

                  • f**

r KD

S( SEP 26 PM213