ML13304A513
| ML13304A513 | |
| Person / Time | |
|---|---|
| Site: | 07201004, Nine Mile Point (DPR-063, NPF-069) |
| Issue date: | 09/27/2013 |
| From: | Darling T Constellation Energy Nuclear Group |
| To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards |
| References | |
| Download: ML13304A513 (3) | |
Text
CENG.
a joint venture of Constell"on=I 0Energy NINE MILE POINT NUCLEAR STATION September 27, 2013 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:
SUBJECT:
Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Nine Mile Point Nuclear Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-63 and NPF-69 Docket Nos. 50-220 and 50-4 10 Nine Mile Point Nuclear Station Independent Spent Fuel Storage Installation General License Docket No. 72-1036 General License 30-day Cask Registration Notification and Thermal Performance Assessment Pursuant to the requirements of 10 CFR 72.212(b)(2), this letter provides the information to register the use of four approved spent fuel storage casks at the Nine Mile Point Nuclear Station (NMPNS)
Independent Spent Fuel Storage Installation (ISFSI).
Licensee's Name:
Address:
Reactor License Numbers:
Docket Numbers:
Person Responsible for Providing additional information:
Cask Certificate Number:
Certificate Amendment Number:
Cask Model Number:
Cask Identification Numbers:
Nine Mile Point Nuclear Station, LLC PO Box 63 Lycoming, NY 13093 DPR-63 and NPF-69 50-220, 50-410 and 72-1036 Ms. Theresa H. Darling 315-349-2221 1004 10 NUHOMS-61BT NMP61B-0 13-A, loaded August 29, 2013 NMP61B-014-A, loaded September 5, 2013 NMP61B-015-A, loaded September 12, 2013 NMP61B-016-A, loaded September 19, 2013 Nine Mile Point Nuclear Station, LLC P.O. Box 63, Lycoming, NY 13093 U
_Z1 Co
ý,ksýýk
Document Control Desk September 27, 2013 Page 2 The Technical Specifications (TS) for Certificate of Compliance (CoC) No. 1004, Amendment No. 10,
§1.1.7 "Special Requirements for First System in Place", requires the results of the temperature measurements of the first Dry Shielded Canister (DSC) placed in service be submitted to the NRC for evaluation and assessment. Additionally, this section of TS requires subsequent users of the system to report heat loads higher than the first user. The first user of the NUHOMS CoC No. 1004, Duke Energy, submitted the heat transfer characteristics for an 18.95 kilowatt (kW) Dry Shielded Canister (DSC) in a letter to the NRC, from Duke Energy, "Cask Certificate of Compliance, Docket No.: 72-1004, 30-day Report for Higher Canister Heat Loading per General Requirement Section 1.1.7," dated August 8, 2007 (ML072340622). The first DSC loaded at NMPNS had a heat load of 7.30 kW, as reported in our letter dated October 17, 2012.
A summary of the thermal performance of the submitted for your information.
Horizontal Storage Module (HSM) Model:
HSM Identification Number:
Cask:
Calculated Heat Load:
Calculated AT:
Actual AT (Note 1):
HSM Identification Number:
Cask:
Calculated Heat Load:
Calculated AT:
Actual AT (Note 1):
HSM Identification Number:
Cask:
Calculated Heat Load:
Calculated AT:
Actual AT (Note 1):
HSM Identification Number:
Cask:
Calculated Heat Load:
Calculated AT:
Actual AT (Note 1):
13th through 16th DSCs in place at the NMPNS ISFSI is NUHOMS Model 102 7DFS-HSM003C NMP611B-013-A 9.04 kW 48 degrees F 45.9 degrees F 7DFS-HSM003D NMP61B-014-A 8.99 kW 49 degrees F 35 degrees F 7DFS-HSM003E NMP61B-015-A 9.02 kW 48 degrees F 24.25 degrees F 7DFS-HSM003F NMP61B-016-A 8.98 kW 48 degrees F 41.75 degrees F Note 1: The actual AT represents the measured AT obtained during equilibrium conditions. Equilibrium conditions were achieved when the daily temperature change observed was less than 6 degrees F over three consecutive days.
Document Control Desk September 27, 2013 Page 3 This letter contains no NRC commitments. Should you have any questions regarding the information in this submittal, please contact me at (315) 349-2221.
Sincerely, Theresa H. Darling Acting Director Licensing cc:
NRC Regional Administrator, Region I NRC Resident Inspector NRR Project Manager