ML13302B373

From kanterella
Jump to navigation Jump to search
Forwards Feedring Failure Root Cause Rept San Onofre Nuclear Generating Station Units 2 & 3, Per Failures Discovered in Steam Generators
ML13302B373
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 11/29/1990
From: Nandy F
Southern California Edison Co
To:
NRC/IRM
Shared Package
ML13302B374 List:
References
NUDOCS 9012070159
Download: ML13302B373 (2)


Text

{{#Wiki_filter:ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) ACCESSION NBR:9012070159 DOC.DATE: 90/11/29 NOTARIZED: NO FACIL:50-361 San Onofre Nuclear Station, Unit 2, Southern Californ 05000361 50-362 San Onofre Nuclear Station, Unit 3, Southern Californ 05000362 AUTH.NAME AUTHOR AFFILIATION NANDY,F.R. Southern California Edison Co. RECIP.NAME RECIPIENT AFFILIATION R Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "Feedring Failure Root Cause Rept...," per failuresI discovered in steam generators. D DISTRIBUTION CODE: A001D COPIES RECEIVED:LTR _ ENCL SIZE TITLE: OR Submittal: General Distribution S NOTES: RECIPIENT COPIES RECIPIENT COPIES A ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD5 LA 1 1 PD5 PD 1 D KOKAJKO,L. 2 INTERNAL: ACRS 6 NRR/DET/ECMB 9H 1 NRR/DET/ESGB 1 NRR/DOEA/OTSB11 1 S NRR/DST 8E2 1 NRR/DST/SELB 8D 1 NRR/DST/SICB 7E 1 NRR/DST/SRXB 8E 1 NUDOCS-ABSTRACT 1 OC1 OGC/HDS2 1 ILE_ 01 1 1 RES/DSIR/EIB 1 EXTERNAL: NRC PDR 1 1 NSIC 1 R I D S A D D NOTE TO ALL "RIDS" RECIPIENTS: S PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED! TOTAL NUMBER OF COPIES REQUIRED: LTTR 24 ENCL 22,

Southern California Edison Company 23 PARKER STREET IRVINE, CALIFORNIA 92718 November 29, 1990 F. R. NANDY TELEPHONE MANAGER. NUCLEAR LICENSING (714) 454-4504 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 Steam Generator Feedring Failure, Root Cause Report San Onofre Nuclear Generating Station Units 2 and 3 This letter transmits "Feedring Failure Root Cause Report, San Onofre"Nuclear Generating Station, Units 2 and 3", at the request of Mr. Lawrence Kokajko, NRC Project Manager for San Onofre Units 2 and 3. This-report documents the analysis performed by Southern California Edison to identify the root cause of the feedring and vent failures discovered in the steam generators at Units 2 and 3 earlier this year. This analysis determined the root cause of the steam generator feedring failure was inadequate design by the steam generator vendor. Several corrective actions, as identified in the enclosed report, were taken to resolve the feedring and vent failures. If you have any questions please call me. Very truly yours, cc: J. B. Martin, Regional Administrator, NRC Region V C. Caldwell, NRC Senior Resident Inspector, San Onofre Units 1, 2 and 3 F~r'R .006"K:, C 'RC-. DR AOCK05000361 P =*nc.}}