Board Notification:Encl Util Forwards Rept Addressing Geology of Area Offshore of Facilities,Per 810622 Seismic Hearings
ML13302B143
Person / Time
Site: San Onofre  
Issue date: 06/18/1981
From: Eisenhut D
Office of Nuclear Reactor Regulation
To:
Atomic Safety and Licensing Board Panel
References
TASK-AS, TASK-BN-81-12 BN--81-12, BN-81-12, NUDOCS 8107140270
Download: ML13302B143 (13)


Text

JUN 1 8 1981 MEMORANDUM FOR: The Atomic Safety and Licensing Board for San Onofre Nuclear Generating Station, Units 2 and 3 FROM:

Darrell G. Eisenhut, Director, Division of Licensing, NRR

SUBJECT:

BOARD NOTIFICATION -

GEOLOGICAL DATA (BN 81-12)

The enclosed letter from the applicants forwards a report addressing the geology of the area offshore of the Sa' Onofre 2 and 3 facilities. The well data discussed in the enclosed letter are not included. This information is being forwarded to the San Onofre 2'and 3 Licensing Board because it relates to the seismic hearing which is scheduled to begin on June 22, 1981.

Original signed by Darrell G. Eisenhut Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation.

Enclosure:

Ltr. from Southern California Edison Company, dtd. 6/5/81 8107140270 810618 PDR ADOCK 05000361 A

PDR OFFICE)DL L

R DL: B#3 SURNME~a 7~.~qoI isenut.

.V!V....................

SURNAME

./****......

r iSenhut ee DATE

/81 6/

1 6/181 6A//

/ 81 60-81 NRcrom as FOM38(08 NcM o240 OFFICIAL RECORD COPY

  • USGPO: 1980-329-824

BOARD NOTIFICATION DISTRIBUTION Docket File 50- 361/362 LPDR PDR NSIC TERA LB#3 File DEisenhut RPurple SVarga TIppolito RClark RReid BJYoungblood ASchwencer FMiraglia JRMiller DCrutchfield BRussell JO1shinski HRood Project Manager JLee RHVollmer TMurley RMattson SHanauer BSnyder RHartfield, MPA OELD OI&E (3)

ACRS (16)

HDenton ECase PPAS (H. Thompson)

EHughes bcc: W. J. Dircks V. Stello

MEMORANDUM FOR:

The Atomic Safety and Licensing Board for San Onofre Nuclear Generating Station, Units 2 and 3 FROM:

Darrell G. Eisenhut, Director, Division of Licensing, NRR

SUBJECT:

BOARD NOTIFICATION - GEOLOGICAL DATA (BN 81-12)

The enclosed letter from the applicants forwards a report addressing the geology of the area offshore of the San Onofre 2 and 3 facilities, The well data discussed in the enclosed letter are not included. This information is being forwarded to the San Onofre 2 and 3 Licensing Board because it relates to the seismic hearing which is scheduled to begin on June 22, 1981.

-z6 Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation

Enclosure:

Ltr. from Southern California Edison Company, dtd, 6/5/81

BOARD NOTIFICATION DISTRIBUTION San Onofre Atomic Safety and Licensing Board Panel Atomic Safety and Licensing Appeal Board Docketing and Service Section A. S. Carstens Phyllis M. Gallaher, Esq.

David W. Gilman Dr. Cadet H. Hand, Jr.

Mrs. Lyn Harris Hicks Mrs. Elizabeth B. Johnson James L. Kelley Janice E. Kerr, Esq.

J. Calvin Simpson, Esq.

Lawrence Q. Garcia, Esq.

Charles R. Kocher James A. Beoletto, Esq.

Charles E. McClung, Jr., Esq.

David R. Pigott, Esq.

Edward B. Rogin Samuel B. Casey, Esq.

John A. Mendez Alan R. Watts, Esq.

Daniel K. Spradlin Richard J. Wharton, Esq.

ACRS Members Mr. Myer Bender Dr. Max W. Carbon Mr. Jesse C. Ebersole Mr. Harold Etherington Dr. William Kerr Dr. Harold W. Lewis Dr. J. Carson Mark Mr. William M. Mathis Dr. Dade W. Moeller Dr. David Okrent Dr. Milton S. Plesset Mr. Jeremiah J. Ray Dr. Paul G. Shewmon Dr. Chester P. Siess Mr. David A. Ward

P 0. acxb 2244 WALNUT

_I AZ:

ROSEMEAD.CALIFORNIA 917 7 0 TELE=-IONE MANAGER Or NUCLFAR ENGINEERING.

J a

1 SA FEv ANDLIaCENSING Director, Office of Nuclear Reactor Regulation Attention: Mr.'Frank Miraglia, Branch Chief Licensing Branch No. 3 U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 San Onofre Nuclear Generating Station Units 2&3 The purpose of this letter is to transmit SCE's assessment of data from three oil wells drilled in the Capistrano Embayment during the period; 1978-1980. These three wells were previously addressed in a letter from SCE (K. P. Baskin) to the NRC (F. R. Miraglia) dated April 1, 1981.

Please find enclosed, seven copies (NRC Mail Code BO-24) of "Report on Recent Oil Exploration Drilling - Capistrano Embayment Area, Orange County, California" by Mr. Jack C. West, dated May 20, 1981. This report documents Mr. West's attempts to obtain the subject well data and his analysis thereof.

For the two wells for which Mr. West was able to obtain data (Arriba de la Estrella "J. W. Ficklin" No.

1 and Santa Fe Energy "Reed-Krum" No. 1) the primary conclusion is that the data does not effect his previous interpreta tions as documented in "Supplement to the Generalized Subsurface Geological and Geophysical Study, Capistrano Area, Orange, California," 1979, by J. C. West. Although data from the third well (Texaco "O'Neill" No. 3) is not available, this well is very close to a well which produced good data which was utlized in Mr. West's previous reports.

Also enclosed please find seven copies (NRC Mail Code B0-24) of the data from Well No. 1, Arriba de la Estrella, "J. W. Ficklin" No. 1 and Well No. 2, Santa Fe Energy "Reed Krum" No. 1. As indicated in Mr. West's report, the data from Well No. 2 is proprietary to Santa Fe Energy Co. and as discussed with the Regulatory staff, should be held in confidence for internal k1V9 w 59,

review pending receipt of the affidavit and request fu withholding the repor from public disclosure.

An affidavit specifying the basis for designating tne material proprietary and a request to withhold the data from public disclosure pursuant to 10 CFR 2.790(b) will be transmited subsequentiy.

If you have any questions concerning this maLter, please cbntact me.

Very truly yours, Enclosures cc:

USGS, Menlo Park, CA (Dr. J. Andrews)

USGS, Reston, VA (J. F. Devine)

California Division of Mines and Geology (P. Amimoto)

D. B. Slemmons

-,IS Wst Commonwealth Ave., Swtc 20b Fuicrton, C.Jifornia 92632 Telephone (714) 525-3366 May 20, 1981 REPORT ON RECENT OIL EXPLORATION DRILLING--CAPISTRANO ENBAYMENT AREA ORANGE COUNTY, CALIORNIA This report sets forth the results of a study of the available basic data obtained from three recent holes drilled within the San Juan Capistrano embayment.

No. 1 Arriba de la Estrella "J.W. Ficklin" No. 1 Elevation -

1180' ground, 1191' Kelly Bushing Spud 12/5/78; Abandoned 12/29/78; Total Depth 3856' Location 1390' South, 220' East from Northwest corner Section 24, T6S, Rid The location of this hole is plotted on Exhibit B-Generalized contours on Base Tertiary--Top Cretaceous, Revised November 1978.

The following data was obtained from the State Division of Oil and Gas A. Electrical Surveys

1. Dual Induction laterolog
2. Compensated Neutron Formation Density Log
3. Formation Factor Log
4. Dipmeter Plot and Tabulations B. Well Summary Report and History

U.

Eiscelianeous Opertional Reports between Operator and DOG D. Schlumberger Wire Line Formation tests The hole spudded in beds near the top of the Santiago formation (Eocene).

No paleontological report was made on the sediments penetrated by the hole.

The following formation contacts have been determined by electric log correlation with other wells and partly by projection of regional thickness of sub-surface formation members.

1110 -

Base Santiago (Eocene)/Top Silverado (Palescone) 1660 -

Top Cretaceous (Pleasants member of Williams formation)

Good development of sandstone within the Pleasants member was found between 2100 and 2375 feet 3828 -

Total depth--in shales near the base of the Pleasants member Dipmeter was run only in the interval 7D00' to 3000' where the approximate averae dips varied between 150 to 200 South 52 to 72o West.

The hole is located approximately 2000' feet west of the Mission Viejo fault, which in this vicinity is about parallel to but four miles east of the Cristianitos fault.

No evidence of oil or gas is indicated from the electrical surveys or wire line formation tests.

The abandonment report, however, did mention a gas show on the ditch at 2130', which in this hole is the top of the sandstone unit in the Pleasants member.

No evidence of faulting was found in the hole and the above formation contacts indicate that the structural interpretation is about as shown on Exhibit B referred to above.

1, va U 0,

1elly 7ushing (65 rcn Location 2900' North, 450' East from the Southwest corner Section 9, T6S, R7W Spud 5/15/80; Abandoned 12/19/80; TD 6609' Information on this hole has not been released to the public by the operator.

owever, the operator has re leased the following data for the exclusive use by Southern California Edison Company and the Nuclear Regulatory Commission.

A. Electrical Surveys

1. Dual Induction-Laterolog
2. Bore Hole Compensated Sonic Log
3. Dipmeter Plot 1Mud and Ditch Sample Log C. lalentological Report D. Well Summary and History This hole is located about 4500' southwest of the surface trace of the Forster branch of the Cristianitos fault.

It falls about on line with structure section C-B by Jack C. West dated July 1975 and revised December 1978, approximately 1400' south west of Northlode "University of California" No. 1.

The hole spudded in the Capistrano Formation. The following formation contacts have been determined from the above data.

1300 -

Base Capistrano/Top Monterey Formation 2240 -

Base Monterey/Top San Onofre Breccia 2505 -

Base San Onofre Breccia/Top Topanga-SESPE (undifferentiated) 39004 Top Santiago-Silverado (Eocene-Paleocene)

(undifferentiated) 6609 -

Total Depth (in Paleocene) according to Paleontological Report

Th da.........tr of thi s hole (to 53U! -NJ in dicate no sia4nificant change in the sub-surface geoloFic inter mretation of the hiocene and younger beds as shown on str'ucture section C-B and on xxhibit A-1, generalized contours near the top of the Monterey by Jack C. West dated December 1978.

Electric log correlation and the paleontological report indicate, however, that the Cretaceous was not reached in this hole.

This data along with comparison of the dipmeter in this hole with the Northlode hole suggest the presence of older fault ing-leaving the area of the Santa Fe hole at Cretaceous depth in a structurally low fault block.

The direction of this older faulting probably trends nnrthwest si mil r to other old faulting in this regional area.

This older fault block is about one mile west of the Cristianitos fault and has no relation to the younger and2 more north trending Cristianitos Fault Zone.

The strongest oil And gas shows encountered in this hole occur at the following depths:

4360 -

4380' 4550 -

4600' 6465 -

6500' Casing was run in this hole and the well history confirms that the lower show was perforated, acidizid, and tested by pumping. The test recovered no formation fluids of any kind, which indicates a very hard and impermeable reservoir.

The writer was informed verbally by the operator that the upper shows were also later tested in a like manner with the same results prior to abandonment.

.3 T'exaico inc. "O'Neill" 7o.

3

-lpvation 390, helly hushing Location 1700' Soutih, 100 East, from the Northwest corner Section 23, TS, Ri7W Spud 10/27/20; Total Depth 4500'; Redrilled from 1800' to 4487' Total Depth; Ran casing and completed well; minor produrtion reported; well shut in; Operator reports "evaluating area"f.

The surface location of this well falls on the line of structure section H-G, by Jack C. West dated July 1975, revised December 1978.

It is located approximately 400' northeasterly of Texaco "O'Neill Estate NCT No.

1-1", and approximately 750' southwesterly of the most westerly branch of the surface trace of the Cristianitos Fault Zone.

Texaco has informed the writer in writing that the original hole, total depth 4500', was a straight hole, and that the redrill, total depth 4487' (4437' vertical depth) was directed westerly with the bottom hole coordinates 61' south -

545' west from the surface location.

Thus, the redrill is practically a twin to Texaco "Estate NCT 1o. 1-1" at the depths 3500'+ to 4487'.

The writer has discussed with the operator (Texaco) at considerable length the release of all the basic data from this well for the exclusive use by the Southern California Edison Company and the Nuclear Regulatory Commission. Texaco will not release this data at this time mainly because of industry com petition which involves land lease problems, additional evalu ation in prep.-,tion for more possible drilling, and the trading value of their data with competitors. Texaco is aware of the writer's interpretaion of the Cristianitos fault in the vicinity

o their wells and they have verb;ally i 3o0e the writer that their new dstta does not reflect any structural change that would suggest any type, magnitude, or timing of fault movement along the CristianAtos Fault Zone different from that shown on Section H-G.

In re<ard to questions -egarding recent drilling in the vicinity of the Cristianitos fault the writer summarizes the results of the above drilling as follows:

No.

1 Arriba de la En.trolla "J.W.Ficklin" No.

1 T'his hole is loc-ated about four miles east of the Crist ianitos fault.

The data from this hole shows no faulting and does not effect the present geologic interpretation of the Cristiani.tos fault.

1o. 2

Sant~a Fe Ener y ">.eed-Frun" No.

1 This hole is located about one mile west of the Crist ianitos fault.

The data from this hole indicates no faulting that cuts the bore hole and that the upper beds, Lower r1iocene-Oligocene,in age are normal in structural position and thickness to a depth of 3500'+. Below this depth to total depth, 6609',the beds are thicker than normal and the paleontological report indicates that Cretqoeous was not reached. This condition and other well data mentioned above suggests older faulting--not related to the Cristianitos fault as discussed above.

Accordingly, the writer believes that data from this hole does not effect the present interpretation of the Crist ianitos fault.

This wpl!

3s located about 750' west of the cristianitzz fault.

explained above the data from this well, than its redrilled position is not available at this and probably will not be available for six months or a year. lowever, as discussed above, it is very close to a well where we have good data that provides substantial informaticn tcaward the present geologic interpretation of the Cristianitos fault.

The operator has verbally in formed the writer that there is no new data from this new well that would change the present interpretation of the Cristianitos fault.

Of the three new holes, the Texaco "O'Neill" No. 3 is the only well that recovered any oil--which is a minor amount.

In the writer's opinion, hydrocarbon withdrawal from any future oil or gas discovery along or near the Cristianitos fault would have no effect on movement along or near this fault zone.

./

JACK C. WEST