ISFSI - General License 30-day Cask Registration Notification and Thermal Performance Assessment
ML13261A303
Person / Time
Site: 07201004, Nine Mile Point  Constellation icon.png
Issue date: 09/12/2013
From: Darling T
Constellation Energy Nuclear Group, EDF Group, Nine Mile Point
To:
Document Control Desk, NRC/NMSS/SFST
References
Download: ML13261A303 (2)


Text

CENG.O a joint venture of Constellation Energy" 64r eDF..

NINE MILE POINT NUCLEAR STATION September 12, 2013 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:

SUBJECT:

Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Nine Mile Point Nuclear Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-63 and NPF-69 Docket Nos. 50-220 and 50-4 10 Nine Mile Point Nuclear Station Independent Spent Fuel Storage Installation General License Docket No. 72-1036 General License 30-day Cask Registration Notification and Thermal Performance Assessment Pursuant to the requirements of 10 CFR 72.212(b)(2), this letter provides the information to register the use of two approved spent fuel storage casks at the Nine Mile Point Nuclear Station (NMPNS)

Independent Spent Fuel Storage Installation (ISFSI).

Licensee's Name:

Nine Mile Point Nuclear Station, LLC Address:

PO Box 63 Lycoming, NY 13093 DPR-63 and NPF-69 Reactor License Numbers:

Docket Numbers:

Person Responsible for Providing additional information:

Cask Certificate Number:

Certificate Amendment Number:

Cask Model Number:

Cask Identification Numbers:

50-220, 50-410 and 72-1036 Ms. Theresa H. Darling 315-349-2221 1004 10 NUHOMS-61BT NMP61B-01 I-A, loaded August 13, 2013 NMP61B-012-A, loaded August 21, 2013 Nine Mile Point Nuclear Station, LLC P.O. Box 63, Lycoming, NY 13093 P14,:z~

Document Control Desk September 12, 2013 Page 2 The Technical Specifications (TS) for Certificate of Compliance (CoC) No. 1004, Amendment No. 10,

§1.1.7 "Special Requirements for First System in Place", requires the results of the temperature measurements of the first Dry Shielded Canister (DSC) placed in service be submitted to the NRC for evaluation and assessment. Additionally, this section of TS requires subsequent users of the system to report heat loads higher than the first user. The first user of the NUHOMS CoC No. 1004, Duke Energy, submitted the heat transfer characteristics for an 18.95 kilowatt (kW) Dry Shielded Canister (DSC) in a letter to the NRC, from Duke Energy, "Cask Certificate of Compliance, Docket No.: 72-1004, 30-day Report for Higher Canister Heat Loading per General Requirement Section 1.1.7," dated August 8, 2007 (ML072340622). The first DSC loaded at NMPNS had a heat load of 7.30 kW, as reported in our letter dated October 17, 2012.

A summary of the thermal performance of the eleventh and twelfth DSCs in place at the NMPNS ISFSI is submitted for your information.

Horizontal Storage Module (HSM) Model:

NUHOMS Model 102 HSM Identification Number:

7DFS-HSM003A Cask:

NMP61B-01 I-A Calculated Heat Load:

9.07 kW Calculated AT:

48 degrees F Actual AT (Note 1):

39 degrees F HSM Identification Number:

7DFS-HSM003B Cask:

NMP61B-012-A Calculated Heat Load:

9.02 kW Calculated AT:

49 degrees F Actual AT (Note 1):

28.65 degrees F Note 1: The actual AT represents the measured AT obtained during equilibrium conditions. Equilibrium conditions were achieved when the daily temperature change observed was less than 6 degrees F over three consecutive days.

This letter contains no NRC commitments. Should you have any questions regarding the information in this submittal, please contact me at (315) 349-2221.

Sincerely, Theresa H. Darling Acting Director Licensing cc:

NRC Regional Administrator, Region I NRC Resident Inspector NRR Project Manager