ML13252A331

From kanterella
Jump to navigation Jump to search
Independent Spent Fuel Storage Installation (ISFSI) - Registration of Dry Spent Fuel Transportable Storage Canister Identification No. AMZDFX107
ML13252A331
Person / Time
Site: 07201015, Palo Verde  Arizona Public Service icon.png
Issue date: 09/06/2013
From:
Arizona Public Service Co
To:
Document Control Desk, NRC/NMSS/SFST
References
102-06762-TNW/RKR/CJS
Download: ML13252A331 (2)


Text

10 CFR 72.212(b)(2)

Qaps Palo Verde Nuclear Generating Station 5801 S. Wintersburg Road 102-06762-TNW/RKR/CJS Tonopah, AZ 85354 September 6, 2013 ATTN: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Palo Verde Nuclear Generating Station (PVNGS) Unit 3 and Independent Spent Fuel Storage Installation (ISFSI)

Docket Nos. STN 50-530 and 72-44 Registration of Dry Spent Fuel Transportable Storage Canister Identification No. AMZDFX107

Dear Sirs:

In accordance with 10 CFR 72.212(b)(2), Arizona Public Service Company (APS) is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the PVNGS ISFSI. The information below is provided for transportable storage canister (TSC) identification no. AMZDFX107, used to store spent fuel within vertical concrete cask (VCC) no. AMZDNE107, beginning on August 30, 2013.

Licensee's Name:

Arizona Public Service Company (APS) is the operating agent for PVNGS.

PVNGS Units 1, 2, and 3 have seven owners who are licensees. The owners/licensees are APS, Salt River Project Agricultural Improvement and Power District, El Paso Electric Company, Southern California Edison Company, Public Service Company of New Mexico, Los Angeles Department of Water and Power, and Southern California Public Power Authority. As specified in the PVNGS renewed operating licenses, APS is authorized to act as agent for the PVNGS licensees and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.

A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • San Onofre
  • Wolf Creek

a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Registration of Dry Spent Fuel Storage Canister - Identification No. AMZDFX107 Page 2 Licensee's Address:

Arizona Public Service Company P.O. Box 52034 Phoenix, AZ 85072-2034 Reactor:

Palo Verde Nuclear Generating Station Unit 3 License Number:

Docket Numbers:

NPF-74 STN 50-530 and 72-44 Contact Name and

Title:

Robert K. Roehler, Licensing Section Leader Cask Certificate No.:

Cask Model No.:

Cask Identification Nos.:

Certificate of Compliance No. 1015, Amendment No. 5, January 12, 2009 NAC-UMS Transportable Storage Canister (TSC) Identification No.

AMZDFX107 Vertical Concrete Cask (VCC) Identification No.

AMZDNE107 No commitments are being made to the NRC by this letter.

further information regarding this submittal, please contact Licensing Section Leader, at (623) 393-5241.

Should you need Robert K. Roehler, Sincerely, TNW/RKR/CJS/hsc cc:

ý ý qf('

S. A. Reynolds J. K. Rankin J. A. Reynoso F. S. Gee NRC Region IV Regional Administrator NRC NRR Project Manager for PVNGS (electronic and hard copy)

NRC Senior Resident Inspector for PVNGS NRC SFST (Frank.Gee@nrc.gov)