NL-13-1763, First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049)

From kanterella
(Redirected from ML13240A238)
Jump to navigation Jump to search

First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049)
ML13240A238
Person / Time
Site: Hatch  
Issue date: 08/27/2013
From: Ivey B
Southern Nuclear Operating Co, Southern Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
NL-13-1763, EA-12-049
Download: ML13240A238 (7)


Text

B. L. " Pete" Ivey Southern Nuclear Vice President Operating Company, Inc.

Regulatory Affairs 40 Inverness Center Parkway Post Office Box 1295 Birming ham, AL 35242 Tel 205.992.7619 Fax 205.992.5217 August 27, 2013 Docket Nos.: 50-321 NL-13-1763 50-366 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant - Units 1 and 2 First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049)

References:

1. NRC Order Number EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, dated March 12,2012
2. NRC Interim Staff Guidance JLD-ISG-2012-01, Compliance with Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, Revision 0, dated August 29, 2012
3. NEI 12-06, Diverse and Flexible Coping Strategies (FLEX)

Implementation Guide, Revision 0, dated August 2012

4. Edwin I. Hatch Nuclear Plant - Units 1 and 2 Initial Status Report in Response to Commission Order with Regard to Mitigation Strategies for Beyond Design-Basis External Events (EA-12-049), dated October 23, 2012
5. Edwin I. Hatch Nuclear Plant - Units 1 and 2 Overall Integrated Plan in Response to Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049), dated February 27, 2013 Ladies and Gentlemen:

On March 12,2012, the Nuclear Regulatory Commission (NRC) issued an order (Reference 1) to Southern Nuclear Operating Company. Reference 1 was immediately effective and directs the Edwin I. Hatch Nuclear Plant - Units 1 and 2 (HNP) to develop, implement, and maintain guidance and strategies to maintain or restore core cooling, containment, and spent fuel pool cooling capabilities in the event of a beyond-design-basis external event. Specific requirements are outlined in Attachment 2 of Reference 1.

Reference 1 required submission of an initial status report 60 days following issuance of the final interim staff guidance (Reference 2) and an overall integrated plan pursuant to Section IV, Condition C.1.a of Reference 1.

Reference 2 endorses industry guidance document NEI 12-06, Revision 0 (Reference 3) with clarifications and exceptions identified in Reference 2.

U. S. Nuclear Regulatory Commission NL-13-1763 Page 2 Reference 4 provided the HI\\JP initial status report regarding mitigation strategies.

Reference 5 provided the HNP overall integrated plan.

Reference 1 requires submission of a status report at six-month intervals following submittal of the overall integrated plan. Reference 3 provides direction regarding the content of the status reports. The purpose of this letter is to provide the first six-month status report pursuant to Section IV, Condition C.2, of Reference 1, that delineates progress made in implementing the requirements of Reference 1. The enclosed report provides an update of milestone accomplishments since the last status report, including any changes to the compliance method, schedule, or need for relief and the basis, if any.

This letter contains no NRC commitments. If you have any questions, please contact John Giddens at 205.992.7924.

Mr. B. L. Ivey states he is a Vice President of Southern Nuclear Operating Company, is authorized to execute this oath on behalf of Southern Nuclear Operating Company and, to the best of his knowledge and belief, the facts set forth in this letter are true.

Respectfully submitted,

~==>--

Mr. B. L. Ivey Vice President - Regulatory Affairs BLl/CLN/lac Sworn to and subscribed before me this ci24l'--'day of Alfj U2 f

,2013.

~'la.,\\t~~ '}k~4~~

N tary Public My commission expires: MIA rru k3t pO If

Enclosure:

Edwin I. Hatch Nuclear Plant - Units 1 and 2 First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049) cc:

Southern l\\Juclear Operating Company Mr. S. E. Kuczynski, Chairman, President & CEO Mr. D. G. Bost, Executive Vice President & Chief Nuclear Officer Mr. D. R. Madison, Vice President - Hatch Mr. C. R. Pierce, Regulatory Affairs Director Mr. B. J. Adams, Vice President - Fleet Operations RType: CVC7000

U. S. Nuclear Regulatory Commission NL-13-1763 Page 3 U. S. Nuclear Regulatory Commission Mr. E. Leeds, Director of the Office of Nuclear Reactor Regulations Mr. V. M. McCree, Regional Administrator Mr. R. E. Martin, NRR Senior Project Manager - Hatch Mr. E. D. Morris, Senior Resident Inspector - Hatch Ms. J. A. Kratchman, NRRlJLD/PIVIB Mr. E. E. Bowman, NRRlDPR/PGCB State of Georgia Mr. J. H. Turner, Environmental Director Protection Division

Edwin I. Hatch Nuclear Plant - Units 1 and 2 First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049)

Enclosure Edwin I. Hatch Nuclear Plant - Units 1 and 2 First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049)

Enclosure to NL-13-1763 First Six-Month Status Report of FLEX Implementation Edwin I. Hatch Nuclear Plant - Units 1 and 2 First Six-Month Status Report of the Implementation of the Requirements of the Commission Order with Regard to Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049) 1 Introduction Edwin I. Hatch Nuclear Plant - Units 1 and 2 developed an Overall Integrated Plan (Reference 1 of this enclosure), documenting the diverse and flexible strategies (FLEX), in response to Reference 2. This attachment provides an update of milestone accomplishments since submittal of the Overall Integrated Plan, including any changes to the compliance method, schedule, or need for relief/relaxation and the basis, if any.

2 Milestone Accomplishments In addition to the submittal of status reports, the following milestone(s) directly related to FLEX implementation have been completed since the development of the Overall Integrated Plan (Reference 1), and are current as of June 30, 2013:

None 3

Milestone Schedule Status The following provides an update to Attachment 2 of the Overall Integrated Plan. It provides the activity status of each item, and whether the expected completion date has changed. The dates are planning dates subject to change as design and implementation details are developed. The revised milestone target completion date does not impact the Order implementation date.

Milestone Target Completion Date Activity Status Revised Target Completion Date Submit 60 Day Status Report Oct 2012 Com~ete N/A Submit Overall Integrated Plan Feb 2013 Complete N/A Submit 6 Month Status Report Aug 2013 Complete (see Sec. 2)

N/A Develop Strateqies (Playbook) with RRC Nov 2013 Started Jun 2015 Submit 6 Month Status Report Feb 2014 Not Started Develop Modifications - Unit 2 Apr 2014 Started Initiate Phase 2 Equipment Procurement Jun 2014 Started Submit 6 Month Status Report Aug 2014 Not Started Perform Staffing Analysis (Phase 2)

Auq 2014 Not Started Develop Operational Procedure Changes Sep 2014 Not Started Create Maintenance Procedures Nov 2014 Not Started Develop Training Material Nov 2014 Not Started Submit 6 Month Status Report Feb 2015 Not Started Issue FSGs Mar 2015 Not Started Unit 2 Implementation Outaqe u Mar 2015 Not Started Implement Training Mar 2015 Not Started Develop Modifications - Unit 1 Apr 2015 Not Started Submit 6 Month Status Report Aug 2015 Not Started Submit 6 Month Status Report Feb 2016 Not Started Unit 2 Walk-throuqhs or Demonstrations Apr 2016 Not Started Unit 1 Implementation Outage

  • Apr 2016 Not Started Page 1

Enclosure to NL-13-1763 First Six-Month Status Report of FLEX Implementation Submit 6 Month Status Report Unit 1 Walk-throughs or Demonstrations Unit 2 Implement Non-Outage Mods **

Submit Completion Rej)ort

'Full compliance after second listed refueling outage

" Full compliance by 12/31/2016 since second refueling ou Aug Dec Dec Dec tage is after 12/31/2016 2016 2016 2016 2016 Not Started Not Started Not Started Not Started 4

Changes to Compliance Method There are no changes to the compliance method as documented in the Overall Integrated Plan (Reference 1 of this enclosure).

5 Need for Relief/Relaxation and Basis for the Relief/Relaxation NRC Order EA-12-049 requires implementation of Mitigation Strategies to address an ELAP and LUHS. The endorsed ISG for compliance with NRC Order EA-12-049, ISG-JLD-2012-01, utilized the containment vent required by NRC Order EA-12-050 for the heat removal function for BWRs. Reference 1 provided the Edwin I. Hatch Nuclear Plant - Unit 1 and 2 response to the NRC Order 12-049 utilizing the endorsed guidance from ISG-JLD-2012-01. On June 6, 2013 the NRC rescinded NRC Order EA-12-050 with the issuance of NRC Order EA-13-109. As a result, the Edwin I. Hatch Nuclear Plant - Units 1 and 2 will not be installing a containment vent in accordance with NRC Order EA-12-050 as stated in Reference 1.

Edwin I. Hatch Nuclear Plant - Units 1 and 2 will be revising strategies to comply with NRC Order EA-12-049 during 2013 with information from the industry, NEI and NRC relative to the new requirements and schedule associated with NRC Order EA-13-109. This new strategy will follow NRC issuance of an ISG in October 2013. It is anticipated that the revised criteria and implementation schedule associated with NRC Order EA-13-1 09 may impact containment venting procedures, training and demonstrations related to the compliance date for NRC Order EA-12-049. Edwin I. Hatch Nuclear Plant - Units 1 and 2 will be in compliance with the aspects of the Reference 1 Mitigation Strategies that do not rely upon a Hardened Containment Vent System unless otherwise described.

Any request for relief will be provided in a separate letter to the NRC and referenced in a future six (6) month update. It is anticipated this will occur prior to the February 2014 six (6) month update.

6 Open Items from Overall Integrated Plan and Draft Safety Evaluation The following tables provide a summary of the open items documented in the Overall Integrated Plan or the Draft Safety Evaluation (SE) and the status of each item.

Overall Integrated Plan Open Item Status

1. Structure, content and details of the Regional SAFER Team developing Pilot Response Center playbook will be determined.

Playbook Draft Safety Evaluation Open Item Status None Received to date N/A Page 2

Enclosure to NL-13-1763 First Six-Month Status Report of FLEX Implementation 7

Potential Draft Safety Evaluation Impacts There are no potential impacts to the Draft Safety Evaluation identified at this time.

8 References The following references support the updates to the Overall Integrated Plan described in this enclosure.

1. Edwin I. Hatch Nuclear Plant - Units 1 and 2 Overall Integrated Plan in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)," dated February 27,2013.
2. NRC Order Number EA-12-049, "Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events,"

dated March 12,2012.

9 Other Additional Information The following information provides clarity or corrections to the Overall Integrated Plan but does not constitute a change in strategy:

1. Edwin I. Hatch Nuclear Plant - Unit 1 will not require any additional load-shedding from the existing SBO response, while Unit 2 will load-shed 5 breakers (versus 14 breakers) at a local panel for deep load-shed as referenced on Page 9 of Reference 1.
2. Initiating use of Hardened Containment Vent System (HCVS) per EOPs to maintain containment parameters below design limits and within the limits that allow continued use of RCIC (table item 8) is now between 7 and 7.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />, versus original values of between 7 and 7.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> as referenced on pages 9 and 30 of Reference 1.
3. For the method of SFP makeup referenced on page 35 of Reference 1, operators would require opening 4 manual valves per unit (1 P41-F1383, 1 P41-F070A, 1 P41 F103, 1G41-F217, 2P41-F1156, 2P41-F070A, 2P41-073, and 2G41-F040) versus the 2 valves stated.
4. The revised calculation values for the MCR heat-up to greater than 11 OF is 3.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> versus the assumed value of 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> in Reference 1. The mitigation strategy remains unchanged (Reference 1, Page 42.)
5. The recently performed RCIC room heat-up calculation raised the maximum temperature reached in the room, but the conclusion that it remains below 148°F for the first 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> remains unchanged if the room door is opened at 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, but stays below the 148°F for the first 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> with no actions.

Page 3