Enclosure I Tennessee Valley Authority Browns Ferry Nuclear Plant Units 1, 2, and 3 Comments and Responses to NRC Comments on TVA 2012 ETE Submittals
Comments and Responses to NRC Comments on TVA 2012 ETE Submittals No Site Comment
Response
1 General Disabled and bed-ridden population not Table 1-3 of all 3 projects have been (all 3 sites) adequately addressed. Real or estimated updated to reflect the disabled and bed-numbers should be provided, ridden population Sections 2.1 and 3.1.2 have been updated with disabled/bed-ridden population assumptions and information 2
General No summary table for total number of Section 3.6 and Table 3-5 have been (all 3 sites) available buses, ambulances or other added to address the transportation transport methods.
resources and demand for buses, ambulances or other transport methods.
3 Sequoyah Transit Dependent in Table 1 Total Table 1-3 has been updated and also number of estimated buses should be supporting text in Section 3.1.2 revised based on 30 people per bus or 50% of the stated seating capacity as noted in the NRC guidance.
4 Sequoyah Section 6.8-3-hour to start evacuating This section has been re-written to transit-dependent (allowing time for include more explanation and majority of school buses to return) should justification.
be revised as Table 6-8 shows that the majority of schools have ETEs of more than 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />.
5 Browns Transit Dependent in Table 1 Table 1-3 has been updated and also Ferry Population and bus numbers should be supporting text in Section 3.1.2 estimated based on NRC's guidance (1.5% of permanent population) or a justification should be provided for the current numbers provided in the table.
6 Browns Section 6.7 - Trip departure/preparation This section has been re-written to Ferry time assumption (2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />) for transit-include more explanation and dependent should be justified or justification.
explained better.
7 Watts Bar Transit Dependent in Table 1 Table 1-3 has been updated and also Population and bus numbers should be supporting text in Section 3.1.2 estimated based on NRC's guidance (1.5% of permanent population) or a justification should be provided for the current numbers provided in the table.
8 Watts Bar Section 6.8 - Trip departure/preparation This section has been re-written to time assumption (2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />) for transit-include more explanation and dependent should be justified or revised justification.
to be consistent with the other sites. -1 Tennessee Valley Authority Browns Ferry Nuclear Plant Units 1, 2, and 3 Evacuation Time Estimates for Browns Ferry Nuclear Power Plant Plume Exposure Pathway Emergency Planning Zone
Table B-I ETE Rwlew Crtria Checklst Browns Ferry I £m M1WOUM£M*
Fmin should be described.
yes
$Sa 12
- b. A map should be Included that dne primary fturee of the oft including major roudways, S~lict top* g hal yea FIgures 1-1,1-2, and 1-3 features, boundaries of counties, mad ppultion centem within the EPZT
- c. A comparison of the current and prevbus ETE should be provided and Inckdle similar Ifon am-in yes Tale 1-3 Table 1-1, "ErE ComrKn "of NUEIR70.
- a. A discussion of the approach and level of detai obtained duing the field survey of the roadway network should be yes Sectwon 4.3 and AppendK D IXrOVICed-
- b. Sources of demogrephic data for school, ial fmm, MWe emlr
, end special event shmod be ftffiad.
Yes Se. 11, Bed 3
- c. Discussion should be presented on use of trafc control plans in the analysis.
y__
Dad 2.1
- d. Trafl skmulation models used for fte analyses should be1-Identified by nune and version.
Yea go
.52 and Tae1
- e. Methods used to adess date uncertainties shol be desered.
yMB
- a. The planm basis for the ETE Includes the aaseptUon that the evacuation is ordered promptly and no early pretv ye 2.1, 3. U
- b. A.*nuritorammuwouh Nbl1-2, "GerVA Assumptons," of NUREG/CR-7002 should be provided and ye S
2.1 Incued be"si to jWp their useo*
a T "he ton scenrosl~
In Tllt 1-3, Evacuation 8cermiros, should be developed for the ETE analysis, or a s
ramon yoe AYCA Socceir Tournrnwdt am "Spec W Bet 6.8 should be provided for use of other scenaring.
I II -1
a A discussion should be provided on tt development ofa staged evacuation.
Iyes
yes
__1_2 b.A able should be provided identifying the ERPAs considered for each ETE calculation by downwind direction yes Table &I In each sector.
- c. A table similar to Table 1-4, "Evacuation Areas for a Staged Evacuation Keyhole,' of NUREGICR-7002 should be yes Table 5-1 provided and includes the complete evacuation of the 2, 5, and 10 mile areas and for the 2 mile area/5 mile keyhole evaculatien.
- a. Demand estimation should be developed for the four population groups, Including permanent residents of the 3-1 thru 3-4 Mtaseis Mgfacilities, and schools.
T ye$
- a. The US Census should be the source of the population ye values, or another credible source should be vided.
,_yes Sod_2.13
- b. Population values should be a4usted as necessary for growth to reflect population estimates to the year of the ETE. yes 2010 Census released in Oct 2011 and is most recent
- c. A sector diagram should be included, similar to Figure 2-1, "Population by Sector,' of NUREG/CR-7002, showing the yes Appen C
- a. The persons per vehicle value should be between I and 2 or justification should be provided for other values.
yes Sect 3.1.1 (2.06 person per vehicle)
- b. !gEem&
should be listed.
- ye Table B-11
- a. A Ist of facilties which attract transient populations should be included, and peak and average attendance for these yes Table B-2, B-3 faculties should be listed. The source of information used to develop attendance values should be provided.
- b. The average populaton during the season should be used, lyes
+Sid 3.2 -2
Numbers may vary by scenario, and if so, discusulon on why yes Sd 2.1, 3.3, Tables B.1, -2, B-3 vakue very should be provided.
- e. A setoioagram should be included, sminflar to Figure 2-1 of NUREGICR-7002, showing the population distribtion for yes C.the transiety/oa M SUtO1pasfWfmutdpidl e
- d. The methodology used to determine the number of transit ependent d should be ditacussd yes Sad 3.1.2
- b.
ma y needed to eno te this group falishould be provided.
ataft
&1.2 orc T"bce 3-5
- m. The counbxx evacuation plans for bunkt dependent residenrt s should be used In the e
e yes Seu 3.1.2 dThe o
ethodoloh used to detarsr numbe___r of people with diabillitis and those with acc~es and ftcw needs yes Sadt 3.1.2 who may need assistance an do not resid In special facilities should be provided. Data from kxcallonty registratio; prgrms shol*,d be used In the eatimde, but should not be the only Wt of dasa.
- a. Capacities should be provided for al te of transportatlon resources. Bus seating capacity of 50% should be used or yes Os 2.1 Justification should be provided for hihr values.
- f. An estimate of thIs population shouid provided and Information should be provided that fte edet registration s
So*
y3.1.2 Progrms Wer used In developing ft stime_
- g. A summary table of the total number of buses, ambulances, or other transport needed to support evacuation should be yes Ta.l 35 provided and the quantification of resources should be detaled enouh to assure doub~le counfinq has not occurred.
- a. A Hlit of special facilties, including the type of f, location, and average population should be provie.s Tle SpeciL faciliy staff should be Included In the tota seiL
________________ -3
- c. The number of wheelchair and bad-bound individuals should Table 5-6 be provided.
yes
_Table
- d. An estimate of the number and capacity of vehicles needed Table B4 to support the evacuation of the facility should be provided,__
yesT___e_-
- e. The logistics for moblizing specially trained staff (e.g.,
- media support or scurity suppor for prsons, jai, and N/A Part of offlt agency planning process other correctional facilities) should be discussed when a r-oprise.I
- a. A list of schools including name, location, student population, and transportation resources required to support yes Sect 3.4.2, Table 3-3 & Table B-4 the evacuation, should be provided. The source of this Inormation should be provided.
- b. Transportation resources for elementary and middl schools yes Sect 3.4.2, Table B-4 are based on 100% of the scolxx_
capacity.
- c. The estimate of high school students who will use their personal vehicle to evacuate should be provided and a basis yes Sect 3. adjustment for personal vehicles NIA for the values used should be provided.
- d. The need for return trips should be identifed If necessary.
yeSo
.(nrtutim
- a. A complete list of special events should be provided and Includes information on the population, estimated duration, yes Sect 6.8 and season of the event
- b. The special event that encompasses the peak transient Sect 8.8 population should be analyzed In the ETE.
yes
_Set 8.8
- c. The percent of permanent residents attending the event Sec 6.8 should be estimated.
- a. A shadow evacuation of 20 percent should be included for areas outside the evacuation area extending to 15 miles Sect 1.2, 1.4, 6.4 from the NPP.
- b. Population estimates for the shadow evacuation in the 10 to 15 mile area beyond the EPZ a provided by sector.
ye Appendix C -4
I no uwugW UT mwe 3;nU wvwuuam Onw UnM n IY network should be consistent with the trip 9enerslon ftie jYes m.d '
fo the emuwient rembdor mamulalton-I should be bemed on the average cm~I "fthl. Value mayye hab,rbWlk*A fiw
&lnh b
nnrb%
It112, 4.3
- w.
".ux w
II
- b. Paukhroogh b eould be asimed to have yes Id 2.1, 4.3
- a. A summary tab should be pro ed that ft total papultlam and total vehicles used in the for yes Taa" 3-1 th 3-4
-emnn residents transients, trwuft
-eedrl residents, special factlles, schools, shadow populdon, and s-thrfx*
demand used in each senanio._
- a. The method(s) used to sese ro*d*my capacity should be
- a. A field survey of key rout.s within the EPZ has bowect-4.1 conducted.
y
- b. Inform
,on should be pro,, ded deaclbing theem
.is
- of the survey, mid types of Infrmation gatered and used In fth Seat 4.3
- c. A table skilw to thatIn AppandbcA, IRodway AnC C l lm l t.of NtJIR.,./CR.7002 sh ul be pyvie.
yes Appsn& D
- d. Calouldlo, for a e nt ndwey seWgm nt should be gmr§@id Yes D
- e. A legibe map of the r system that Identle node numbers wid segmenrs ued to develop the ETE should be yes Figure4-1 plusmap m Appendbc 0 provided and should be slmlar to Figur 3-1, "Roadway Netwk Idenftlr Nodes and Segmw.ts" of NJREGCR-7002.
- a. The approach usd to calcublt the roadway capacity for the
%ft, network should be descrbed In dei and ye_______4.___d___D -5
total numbers of lntrsections modeled that are unakinnIlimdb m
aImnal md or mnVnnd by r innnm nmuamnel Sad 7 and AppnIx D yes
- b. Characteristics for the 10 highest volume interctions within the EPZ are provided Including the location, signal cycle yes Table 7-1 length, and him lane queue cap*ct_*.
- c. Discussion should be provided on how time signal cycle Is used In the calculations.
yes Sod 4.3
- a. The adverse weather condition should be identified and the c of adverse weather on mobilization should be Yes Sect 2.3 considered.
- b. The speed and capacity reduction factors identified In Table 3-1, 'Weather Capacity Factom,' of NUREGICR-7002 yes Sect 2.3 should be used or a basis should be provided for other values.
- t. The study Identilles assu mpi n for snow re o a on N/......
xy r rn vW w re as um d
- s. Theprocessusedto dweveoptrip generation tines should beyeSet Identifie.
ysSc
- b. When teehn surveys are used, fte scope of the survey, area of the survey, number of participants, and statistical yes Appendix E relevance should be provided.
- c. Dat obtained from telephone surveys should be summarized.
yes
- d. The trip generation timne for each population group should be deoed from site saci Information.
- a. Permanent residents are assumed to evacuate from their homes but are not assumed to be at home at all times. TrpYest -6
UM IRMIWU IHwIJUU LfW mUMUriut~1n1 IUlt PU 1
gw9 4T
- b. Discussion should be proivided on the time and method used le5 to notify transients. The trip generation time discusses any yes Set dificulties nifying persons in hard to reach ams such es on lakes or in ca2Igrnd.
- c. The trip generation time accounts for transients potentially YE a
retu.ing to hotels Prior to evc*uaIg.
y__
- d. Effect of pubic transportation resources used during special events whea a large number of transients are expected NWA should be considered.
- a. The trip generation time for the transient population should be integrated and ioaded onto the transportation network ys sotd withI t
- a. If availalef existing plans and bus routes are used in the ETE analymiL If new plans am developed with the ETE, they NIA should have been agreed upon by the responsible authorities.
- b. Dismussion should be o
ncktded on the means of evcuting ys oe3 ainbuyLtalio and non-ambulatory residentls.____________________
cm The number, location and avallablitly of buses, and other resources needed to support the demand eilmollon are yes Tble 3-6 provided.
- d. Logistical detalis, such as the time to obtain buses, brief So 3
drivers and initiate the bus route are provided.
7
- a. Discussion should Identify the time estimated for transit dependent residents to prepare and then trvel to a bus Yes 6.7; means of tvd to pik up POW "d pickup poit and describes the expected meens of travel to d
W ASWencM phone nurbers the pkqu point.
Noidw for 111e pubi
- f.
The number of bus stops and time needed to load pass ners should be discussed.
yect 6.7
- g. A my of bus routes W
"'d be Irnuded.
NfA ymmotelsl--
a
- h. The trip genesation tine for non-ambiatory persons includes the time to mobilize ambulances or special yes Set &7 vehicles, time to drive to the home of residents, a
timen. I
__I- -7
il.u Iunratio UIsho U
- t. Information shour
- of return Iyes Sect 6.7 4A.3 Sp cialadlles
- a. Information on evacuation logistics and mobilization times should be provided.
yes Sad 6.7
- b. Discussion should be provided on the inbound and outbound yes Sect 6.7 speeds.
- c. The number of wheelchair and bed-bound Individuals should be provided, and the logistics of evacuating these residents yes Table B-6 should be discussed.
- d. Time for loading of residents should be provided.
yes Sect 6.7
- a. Information should be provided that indicates whether the evacuation can be completed In a single trip or if additional yes Table 646 trips are needed.
- f. If return trips are needed, the destination of vehicles should NIA Rtum trps are not anticipated.
be provided.
- g. Discussion should be provided on whether special facility residents are expected to pass through the reception center Yes Sad 5.4.3 prior to being evacuated to their final destination.
- h. Supporting Information should be provided to quantIfy the time elements for the retum trips.
Yes e 6.7. Retum trips are not anticipated.
4..4.
- a. Information on evacuation logistics and mobilization times should be provided,.e ec.
- b. Discussion should be provided on the inbound and outbound yes Sad 6.7
- c. Trne for loading of students should be provided, yes Sect 6.7
- d. Information should be provided that indicates whether the evacuation can be completed in a single trip or if additional yes Table 6-7 trip we needed.
- e. If return tps are needed, the destination of school b s
A Retur ti ar not anticipated.
should be provided.
_A____umtrips____not
__nticipted.
f, If used, reception centers should be identified. Discussion should be provided on whether students are expected to Yes Sect 5.4.3; Schools evacits directly to host schools pm through the reception center prior to being evacuated S
c -8
I IU fr lo n5W UWUINENML 19g.
Suppodtingtifmna.lonshouldbe d t time elemments for the return trips.I Rdurm bi -* no -iOl f
- a. General information about the model should be provided and demonstrates ft use in ETE studies.
yes So:d
_54
- b. If a trafi simulation model is not used to conduct the ETE calculation, sufficient detail should be provided to validate NA the analytical approach used. Al criteria elements should
- a. Trofi simulation model assumptions and a repre*e"ntative Yes S
set of model inpfts should be provided._____
- b. A glossary of term should be provided for the key perfrmace masues nd pramtersuse inthe es od
, 0.7
- a.
A discussion regarding whether the trefc simulatlion model used must be in-equiwation prior to calculating the ETE yes
- b. The minimum following model outputs should be provided to support review:
yes Sct 6 and Appendix F
- 1. Total volume and percent by hour at each EPZ exit mods.
- 2. Newr wide average travel time.
- 3. Longest Queue length for the 10 intersections with the highest traffic volume.
- 4. Total vehicles exiting the network.
- 5. A plot that provides both the mobilization curve and evacuation curve identifying the cumulative percentage of evacuees who have mobilized and exited the EPZ.
- 6. Average speed for each major evacuation route that exib the EPZ.
- c. Color coded roadway maps should be provided for various
_F times (I.e., at 2,4, 6 hrs., etc.) during a full EPZ evacuation yes ppndix F scenario, identifying areas where long queues exist including leel of serviceLOS) "E' and LOS "F" conditions, I -9
- a.
I IIP vI I I UIlbAgI II,,IAUJ UI m
I WII UI.
lu
- vi.i I
100% of the tota permra*mt residert and transient PoPomflon.
TWble 6-1
- b. :he ETE for 100% of the general public should include all members of the general public. Any reductions or truncated Ye Table 6-1 data should be explained.
- c. Tables should be provided for the 90 and 100 percent ETEs sirnilar to Table 4-3, "ETEs for Staged Evacuation Keyhole,'
Yes Table 6-4 of NUREGICR-7002.
- d. ETEs should be provided for the 100 percent evacuation of
,,w 0 -10
It hOVA be dowlty Iin NI is.5Wa hto pinengm mo leftthe remap owmfr tad m uby q-01 bum to the comrsoam car.
nw'.
7m fuita~i*
I Technical Reviewer Supervisory Review O/U4dA-W V -
xl:ý Date 4
1
.~t
,64013 w -11 Tennessee Valley Authority Browns Ferry Nuclear Plant Units 1, 2, and 3 Table B-I ETE Review Criteria Checklist - Browns Ferry
%, ARCADIS Infrastructure Water Environment Buildings Imagine the result Evacuation Time Estimates for Browns Ferry Nuclear Power Plant Plume Exposure Pathway Emergency Planning Zone August 2013
- 0. ARCADIS Evacuation Time Estimates for Browns Ferry Nuclear Power Plant Plume Exposure Pathway Emergency Planning Zone Prepared for:
Tennessee Valley Authorty Chattanooga, Tennessee Prepared by:
ARCADIS U.S., Inc.
10352 Plaza Americana Drive Baton Rouge Louisiana 70816 Tel 225 292 1004 Fax 225 218 9677 Our Ref.:
TM120006.0001 Date:
August 2013 This document is intended only for the use of the individual or entity for which it was prepared and may contain information that is privileged, confidential and exempt from disclosure under applicable law. Any dissemination, distribution or copying of this document is strictly prohibited.
ARCADIS Table of Contents Executive Summary vi
- 1. Introduction 1-1 1.1 General 1-1 1.2 Site Location and Emergency Planning Zone 1-2 1.3 Designated Reception Centers 1-4 1.4 Overview of Changes from Previous (2008) ETE Study 1-4
- 2.
Methodology and Assumptions 2-1 2.1 Sources of Data and General Assumptions 2-1 2.2 Interaction with Agencies 2-3 2.3 Summary of Methodology for Traffic Simulation 2-4 2.4 Conditions Modeled 2-4 2.4.1 Weekday 2-5 2.4.2 Weeknight 2-5 2.4.3 Weekend 2-6
- 3. Population and Vehicle Demand Evaluation 3-1 3.1 Permanent Residents 3-1 3.1.1 Auto-Owning Permanent Population 3-1 3.1.2 Transit Dependent Permanent Population 3-2 3.2 Seasonal Residents 3-2 3.3 Transient Population 3-2 3.4 Special Facilities Population 3-4 3.4.1 Medical, Nursing Care, and Correctional Facilities 3-4 3.4.2 Schools and Daycare 3-5 3.5 Emergency Response Planning Area Population Totals 3-5 3.6 Transportation Resources 3-5
- 4. Evacuation Roadway Network 4-1 4.1 Network Definition 4-1 Brows Ferry - ETE -VER9.docx
ARCADIS Table of Contents 4.2 Evacuation Route Descriptions 4-1 4.3 Characterizing the Evacuation Network 4-1
- 5.
Evacuation Time Estimate Methodology 5-1 5.1 Evacuation Analysis Cases 5-1 5.2 Initial Notification 5-3 5.3 Transportation-Dependent Population 5-3 5.4 Evacuation Preparation Times and Departure Distributions 5-3 5.4.1 Permanent and Seasonal Population 5-4 5.4.2 Transient Population 5-4 5.4.3 Special Facilities 5-5 5.5 Evacuation Simulation 5-6 5.5.1 General Structure 5-6 5.5.2 Simulation Process 5-7
- 6.
Analysis of Evacuation Times 6-1 6.1 Evacuation Time Estimate Summary 6-1 6.2 Comparison with Previous Study 6-1 6.3 Keyhole Evacuation Scenarios 6-2 6.4 Staged Evacuation Scenarios 6-2 6.5 Sensitivity to Population Growth and Roadway Impact 6-10 6.5.1 Population Growth 6-10 6.5.2 Roadway Impact 6-11 6.6 Performance Metrics for Simulation Model 6-12 6.7 ETE for Transit-Dependent, Special Facilities, and Schools 6-15 6.8 Special Event 6-20
- 7.
Traffic Control Recommendations 7-1 7.1 General 7-1 7.2 Evacuation Access Control Locations 7-1 B.owns Ferny - ETE - VER9.doc=
ii
ARCADIS 7.3 Traffic Management Locations and Tactics to Facilitate Evacuation Tables Table 1-1 Permanent Resident Population in the Browns Ferry EPZ Table 1-2 Designated Reception Centers for Evacuation Table 1-3 ETE Comparison Table 3-1 Resident Population and Vehicle Demand by EPZ Subarea Table 3-2 Transient Population and Vehicle Demand within the Browns Ferry EPZ Table 3-3 Population and Vehicle Demand for Schools and Special Facilities in the Browns Ferry EPZ Table 3-4 Summary of Population and Vehicle Demand within the Browns Ferry EPZ Table 3-5:
Summary of Transportation Resources Table 4-1 Browns Ferry EPZ Primary Evacuation Routes Out of EPZ Table 5-1 Potential Evacuation Areas for Browns Ferry EPZ Table 6-1 Evacuation Time Estimate Summary for Browns Ferry EPZ Table 6-2 Evacuation Time Estimates for Partial EPZ Scenarios (2-Mile Zone Plus 5-Mile Downwind, Unstaged)
Table 6-3 Evacuation Time Estimates for Partial EPZ Scenarios (5-Mile Zone Plus 10-Mile Downwind, Unstaged)
Table 6-4 Evacuation Time Estimates for Staged EPZ Scenarios (2-mile Zone, then 5-miles downwind)
Table 7-1 Predicted Queuing at Major Intersections (Full 10-Mile EPZ, Winter Weekday, Normal Weather)
Table of Contents 7-1 1-9 1-10 1-11 3-6 3-7 3-8 3-9 3-10 4-3 5-2 6-4 6-5 6-6 6-9 7-1 Browns Ferry - ETE - VER9.doCu iii
ARCADIS Figures Figure 1-1 Browns Ferry Nuclear Power Plant Site Location Figure 1-2 Browns Ferry Nuclear Power Plant EPZ Area Figure 1-3 2010 Permanent Resident Population by EPZ Area Figure 4-1 Designated Evacuation Routes for Browns Ferry EPZ Figure 5-1 Departure Time Distributions for the Browns Ferry EPZ Figure 5-2 Evacuation Modeling and Simulation Using PTV Vision Suite Figure 6-1 Stage 2 Departure Time Distributions for the Browns Ferry EPZ Figure 6-2 ETE Population Growth Sensitivity Analysis Figure 6-3 Comparison of Traffic Flows Before and After Road Closure Scenario Figure 6-4 Time Distribution of Vehicles on the Network (Full 10-mile EPZ, Winter Weekday, Normal Weather)
Figure 6-5 Comparison of Vehicle Mobilization and Departure Rates (Total Vehicles 38,807)
Appendices A
Geographical Boundaries of ERPAs B
Transient and Special Facility Population Data C
Population Data Maps D
Roadway Network Map and Data Table E
Telephone Survey of EPZ Residents (Results Summary and Survey Instrument)
F Maps of Average Speed by Hour on Browns Ferry Road Network (Winter Day, Normal Weather, Full EPZ)
Table of Contents 1-6 1-7 1-8 4-5 5-6 5-7 6-3 6-11 6-12 6-14 6-15 Brows Ferry - ETE -VER9.docx iv
%, ARCADIS List of Acronyms and Abbreviations Table of Contents ADT Average daily traffic BAO ESRI Business Analyst Online BFN Browns Ferry Nuclear Power Plant EAS Emergency Alert System EPZ Exposure Pathway Emergency Planning Zone ERPA Emergency Response Protection Area ETE Evacuation Time Estimate GIS Geographic Information System GPS Global Positioning System LOS Level-of-service NRC Nuclear Regulatory Commission PAR Protective Action Recommendation TAR Tone Alert Radios WC Wheelchair Browns Ferry - ETE - VER9.docx V
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Executive Summary This report documents the Evacuation Time Estimate (ETE) study prepared by ARCADIS U.S., Inc. for the Browns Ferry Nuclear Power Plant (BFN) located in Limestone County, Alabama, near the cities of Athens and Decatur. The study reflects the current definition of the Emergency Planning Zone (EPZ), which is the region within a nominal 10-mile distance of BFN. The previous study of evacuation time estimates for BFN was performed in 2008.
The present study was performed using population data from the 2010 U.S. Census.
PTV Vision software was used to perform evacuation modeling for various scenarios. The PTV Vision traffic simulation software package includes VISUM (macroscopic traffic simulation) and VISSIM (microscopic traffic simulation). VISUM is a comprehensive, flexible software system for transportation planning, travel demand modeling, and network data management. VISSIM is capable of performing detailed microscopic simulation of traffic and can model any type of traffic signal control and geometric configuration.
The road network used in the evacuation simulations consists of designated evacuation routes plus any additional roadways needed to accurately simulate conditions during an evacuation. Roadway capacities were determined using NAVTEQTM digital data, updated by ARCADIS based on actual road and intersection data collected in the field in 2012.
Evacuees were generally assumed to proceed out of the EPZ via recommended evacuation routes and to make their way to designated reception centers after leaving the EPZ.
The EPZ for BFN includes portions of four counties in Alabama (Lauderdale, Lawrence, Limestone, and Morgan). The resident population of the Browns Ferry EPZ was estimated at 45,776 permanent residents. Based on housing data from the 2010 U.S. Census, there are 645 seasonal housing units in the EPZ, with an estimated 1,442 seasonal (summer) residents. The 2010 U.S. Census data at block level was used to determine the population in each EPZ subarea.
The transient population, which includes larger workplaces, recreational facilities, and motels, was estimated at 18,311 persons for a winter weekday and 18,532 persons for a summer weekday. The special facilities population, including assisted living, nursing homes, and hospitals, was estimated at 1,019 persons for weekday scenarios. The estimated population of schools and daycare centers for a winter weekday is 11,197, including students and staff. These population estimates include intrinsic double-counting, as some persons in the transient and special facility populations are also included in the Brows Fery - ETE - VER9.docx vi
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates permanent and seasonal resident counts. Thus, evacuation times using these population figures are considered conservative.
Vehicle demand for the resident population was developed based on estimated vehicle occupancy, using data obtained from a telephone survey of EPZ residents. The vehicle occupancy factor estimated from survey responses is 2.06 persons per vehicle, which represents 1.39 vehicles per household. For the 2008 study, vehicle occupancy was 2.45 persons per vehicle (one vehicle per household).
Vehicle demand for the transient population was estimated using vehicle occupancy factors ranging from 1.0 person per vehicle for the workforce population up to 3.0 persons per vehicle for some recreational areas. Vehicle demand for the school population was based on bus occupancy of 55 students. For nursing homes, vehicle occupancy is 20 persons per bus or van for residents, and two persons per ambulance for non-ambulatory patients. For nights and weekends, all facility staff would accompany patients; during weekdays, one vehicle per person was assigned for additional staff.
Total vehicle demand for all population categories ranges from 26,659 (winter weeknight) to 38,807 (winter weekday).
Vehicle demand was also assigned to account for the potential "shadow evacuation" of the population residing immediately outside the EPZ, to a distance of 15 miles. The permanent resident population within this region is 81,302. It was assumed that 20 percent of the population in this region would evacuate. The occupancy factor for EPZ residents (2.06 persons per vehicle) was applied to estimate vehicle demand for this population. Shadow evacuees residing outside the EPZ add vehicle demand of 7,893 vehicles.
Evacuation times were estimated for evacuation of the entire EPZ for winter weekday (daytime and evening), winter weekend day, summer weekday (daytime and evening),
and summer weekend day cases under fair weather conditions. The weekday daytime cases were also evaluated for adverse weather conditions (snow and rain for winter and summer, respectively). Evacuation times were also estimated for one special event, a soccer tournament at the Jack Allen Complex in Decatur.
A "staged evacuation" scenario was also evaluated for the winter daytime case. Under this scenario, only the population within the 2-mile zones closest to BFN would evacuate initially; evacuation of surrounding zones would be initiated after most traffic from the 2-mile zones has cleared. The purpose of this scenario is to assess the Bmrows Ferry-ETE - VER9.docx vii
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates potential reduction in evacuation times that might be achieved for the population at greatest risk.
Simulations were also performed to assess the potential impact of population growth on predicted evacuation times. This sensitivity analysis is used to define a threshold population figure that would trigger another ETE update study.
Evacuation time estimates for vehicles to depart from the 2-mile zone, 5-mile zone, and for the full 10-mile EPZ are summarized in Table E-1. The 100 percent evacuation times for normal weather scenarios are under 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. Adverse weather scenarios typically add 90 minutes to the 100 percent evacuation time, with a maximum ETE of slightly less than 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />. The 90 percent times to evacuate the 2-mile inner ring are 50 to 105 minutes shorter than times to evacuate the full EPZ. Results for "keyhole" evacuation scenarios (inner 2-mile zone plus downwind zones to 10 miles) indicate that zone D-1 0, which includes the city of Decatur, takes the longest time to evacuate.
Most traffic congestion in the EPZ is predicted for scenarios that include the cities of Athens and Decatur.
Table E-1 Evacuation Time Estimate Summary for Browns Ferry EPZ Summer Winter Weekend EvnnWiwekDyieekend Midweek Daytime Daytime Evening Midweek Daytime Weekend Evening Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal Evacuation Area:
90 Percent Evacuation of Affected Areas (hours:minutes) 2-mile Zone 1:30 1:40 1:50 1:40 1:30 1:45 1:50 1:40 5-mile Zone 2:05 2:15 1:55 1:55 2:05 2:30 1:50 1:50 10-mile EPZ 3:05 3:25 2:40 2:50 3:15 3:50 2:35 2:45 100 Percent Evacuation of Affected Areas (hours:minutes) 2-mile Zone 2:55 3:25 3:10 3:10 2:55 3:30 3:10 3:10 5-mile Zone 3:25 4:00 3:25 3:25 3:25 4:05 3:10 3:10 10-mile EPZ 5:10 6:20 4:25 5:00 5:20 6:50 3:50 4:40 Browns Ferry - ETE - VER9.docx viii
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 1. Introduction 1.1 General Evacuation time studies analyze the manner in which the population within the Plume Exposure Pathway Emergency Planning Zone (EPZ) surrounding a nuclear power plant site would evacuate during a radiological emergency. Evacuation time studies provide licensees and state and local governments with site-specific information that is helpful for protective action decision-making. The studies estimate the time necessary to evacuate the EPZ for a range of evacuation scenarios. Analysis of the evacuation simulation results also identifies locations where traffic management and control measures can facilitate the evacuation, and may identify unique evacuation constraints or conditions.
Estimates of the time required to evacuate from areas around nuclear power plant sites are required for all operating plants in the United States. Federal guidance has been prepared to outline the format and content of these evacuation time estimates (NUREG-0654, Rev. 1,1 NUREG/CR-4831, 2 and NUREG/CR-7002 3).
Evacuation time estimate (ETE) studies were last updated for the Browns Ferry Nuclear Power Plant (BFN) Plume Exposure Pathway EPZ in 2008.4 The guidance presented in NUREG/CR-7002 indicates that the evacuation time estimates should be updated as 1 Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, NUREG-0654, FEMA-REP-1, Rev. 1, U.S.
Nuclear Regulatory Commission, Federal Emergency Management Agency, November 1980.
2 State of the Art in Evacuation Time Estimate Studies for Nuclear Power Plants, NUREG/CR-4831, T. E. Urbanik and J. D. Jamison, Pacific Northwest Laboratory, U.S. Nuclear Regulatory Commission, March 1992.
3 Criteria for Development of Evacuation Time Estimate Studies, NUREG/CR-7002, J. Jones and F. Walton, Sandia National Laboratories, and B. Wolshon, Louisiana State University, November 2011.
4 Evacuation Time Estimate: Browns Ferry Nuclear Power Plant, prepared by IEM, Inc. for TVA and Alabama Emergency Management Agency, August 2008.
Brows Ferry - ETE - VER9.docx 1-1
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates local conditions change, but at least once each decade, following release of the federal census. The current update study was prompted by the issuance of revised ETE guidance (CR-7002) and the availability of population data from the 2010 U.S. Census.
Census data indicate that the population residing within the EPZ for BFN increased by 1,703 between 2000 and 2010, which represents a 3.9 percent population increase.
(Population data are discussed further in Section 1.4.)
The evacuation time estimates have been developed using current population, local roadway network characteristics, and the PTV Vision traffic simulation software package to perform evacuation modeling for various scenarios. PTV Vision includes the VISSIM (microscopic traffic simulation) and VISUM (macroscopic traffic simulation) models. Evacuation times have been estimated for various areas, times, and weather conditions, as outlined in CR-7002. These evacuation times represent the times required for completing the following actions:
Public notification Preparation and mobilization Actual movement out of the EPZ (i.e., on-road travel time, including delays associated with vehicle queuing) 1.2 Site Location and Emergency Planning Zone This report describes the analyses undertaken, and the results obtained, in a study to update the existing evacuation time estimates for BFN. The emergency response plan is designed to protect the health and safety of the public in the.event that an evacuation is ordered as a protective action in response to an accident at BFN.
BFN is located in Limestone County, Alabama, along the north side of Wheeler Lake, approximately 10 miles southwest of the City of Athens. The City of Decatur is approximately 10 miles southeast and the City of Huntsville is approximately 28 miles east of the plant. The site location is shown on Figure 1-1. The plume exposure pathway EPZ is the geographic area surrounding a nuclear power plant within which the Nuclear Regulatory Commission (NRC) requires advance planning for evacuation or other short-term protective actions in the event of a radiological emergency. The Browns Ferry EPZ consists of the area within an approximate 10-mile radius of BFN, as shown on Figure 1-2. The EPZ includes portions of four Alabama counties (Lauderdale, Lawrence, Limestone, and Morgan).
1-2 Browns Feny - ETE -VER9.doc-
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates The Browns Ferry EPZ is subdivided into 20 sectors or subareas, or Emergency Response Protection Areas (ERPAs). These ERPAs are the basic units for which protective action recommendations are issued. Subarea boundaries often follow geographic or political (township) boundaries and reflect distance and direction from BFN. The distance ranges of concern are 0 to 2 miles, 2 to 5 miles, and more than 5 miles. EPZ and ERPA boundaries are shown on Figure 1-2. The northern side of the EPZ, accounting for almost half of the total EPZ area, is in Limestone County. ERPAs 1-10 and J-10, in the northwestern quadrant of the EPZ, are in Lauderdale County. The seven ERPAs on the southern side of the EPZ are in Lawrence County and four ERPAs are in Morgan County. Appendix A contains boundary descriptions of the ERPAs.
A listing of the 2010 permanent resident population by ERPA within the Browns Ferry EPZ is shown on Figure 1-3 (a sector diagram is provided in Appendix C). Table 1-1 compares the EPZ population from the 2010 and the 2000 U.S. Census. The population residing in the EPZ grew by 1,703 between 2000 and 2010, an increase of 3.9 percent. ERPA B-2 grew by more than 20 percent and ERPAs C-10 and D-10 grew by 10 percent or more. ERPAs F-2, E-5, F-5, G-5, and J-10 declined by more than 20 percent. More than 25 percent of the EPZ population of 45,776 residents is in ERPA D-10, which includes parts of the City of Decatur. Four other ERPAs (A-10, B-10, C-10, and F-10) have more than 3,000 residents. ERPAs within 0 to 2 miles are rural, with close to 500 residents in them combined. ERPAs within 0 to 5 miles have approximately 3,500 residents in them combined. Between 2000 and 2010, the population of 0 to 2 miles increased by 4 percent and 0 to 5 miles decreased by 4 percent. Between 2000 and 2010, the combined population of all the ERPAs in Limestone County and Morgan County increased by 3 percent and 8 percent, respectively. Between 2000 and 2010, the combined population of all the ERPAs in Lawrence County and Lauderdale County decreased by 7 percent each.
United States Highway 72 (U.S. Highway 72), U.S. Highway 31, and State Highways 20, 24, 33, 67, and 157 are major evacuation roadways in the EPZ. Wheeler Lake crosses the EPZ from the northwest to the southeast. Interstate 65 (1-65) runs north and south outside the eastern limits of the EPZ.
NRC guidance also requires consideration of potential "shadow evacuation" of the population residing immediately outside of the EPZ, to a distance of 15 miles. The permanent resident population within this region is 81,302. It was assumed (based on NRC guidance in CR-7002) that 20 percent of the population in this region would evacuate. The occupancy factor for EPZ residents (2.06 per vehicle) was applied to Browns Ferry -ETE - VER9.doc1 1-3
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates estimate vehicle demand for this population. Shadow evacuees residing outside the EPZ add vehicle demand of 7,893 vehicles.
1.3 Designated Reception Centers The Browns Ferry emergency response evacuation plan directs residents of communities within the EPZ to evacuate to specified reception centers. If evacuation is initiated while schools are in session, students will be transported directly to designated host schools, and families are instructed to meet up with the students at those locations.
The designated reception centers for ERPAs within the Browns Ferry EPZ are Brooks High School, Moulton Recreation Center, West Limestone High School, Elkmont High School, East Limestone High School, Ardmore High School, Hartselle Junior High School, and Priceville School. The preferred reception center for each ERPA is listed in Table 1-2. (Some ERPAs may evacuate differently, depending upon the prevailing wind direction.) The roadway network used to develop evacuation time estimates includes the major roadways recommended to the public as evacuation routes from individual communities to designated reception centers. The roadway network is designed to utilize all available major roadways, with traffic flow directed radially outward from BFN toward the EPZ boundaries. The roadway network is described in detail in Section 4.
1.4 Overview of Changes from Previous (2008) ETE Study The changes in residential population within the EPZ are summarized in Table 1-1.
The revised NRC guidance and newly acquired data led to a number of other changes in the ETE methodology and assumptions. Table 1-3 provides a summary comparing the main features and assumptions of the current study to the 2008 ETE study. The telephone survey of EPZ residents provides a new basis for estimating vehicle occupancy and departure times, while new NRC guidance has specified different assumptions regarding background and "shadow" traffic. The ETE methodology and assumptions for the current study are discussed in greater detail in subsequent sections of this report.
The increase in EPZ population, revised vehicle occupancy for residents (2.06 persons per vehicle, based on survey responses), revised departure times for schools and special facilities (no "early warning"), and revised departure time curves for residents (based on survey responses and estimated time for warning diffusion) are Browns Ferry - ETE - VER9.docx 1-4
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates expected to have the greatest influence on estimated evacuation times. The "shadow evacuation" adds vehicle demand of 81,302 vehicles in the area immediately outside of the EPZ. One special event scenario was added. Each of these issues is discussed in more detail in subsequent sections of this report.
Bro-s Feny - ETE - VER9 docx 1-5
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 1-1 Permanent Resident Population in the Browns Ferry EPZ ERALandmark Descriptions Census Census Percent ERA2000a 2010' Change 0 to 2 miles A-2 BFN 232 218
-6.0 B-2 178 216 21.3 F-2 Wheeler Reservation 9
7
-22.2 G-2 Mallard Creek Campground 80 77
-3.8 2 to 5 miles A-5 Poplar Creek 1,700 1,757 3.4 B-5 Cow Ford RV Park 671 646
-3.7 E-5 United Launch Alliance 152 97
-36.2 F-5 288 221
-23.3 G-5 Mallard Creek-Tennessee River confluence 245 183
-25.3 5 to 10 miles A-10 Sportsmans Park 8,418 8,857 5.2 B-10 Tanner Head Start 6,180 6,166
-0.2 C-10 Ingalls Harbor, 3M, Pepsi-Cola 3,770 4,149 10.1 D-10 Parkway Medical Center 11,776 13,017 10.5 E-10 West Morgan elementary and high schools 3,076 2,972
-3.4 F-10 Town of Hillsboro, East Lawrence elementary, middle, and high schools 3,121 3,036
-2.7 G-10 736 671
-8.8 H-10 Spring Creek bridge 146 126
-13.7 1-10 Elk-Tennessee River confluence 518 520 0.4 J-10 Elk River boat ramp 258 202
-21.7 K-10 Elk River Lodge State Park, Bay Hill Marina 2,519 2,638 4.7 Browns Ferry EPZ Total 44,073 45,776
3.9 Sources
a) 2000 and 2010 U.S. Census data (block level)
Browns Ferry-ETE - VER9Adoc1 1-9
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 1-2 Designated Reception Centers for Evacuation ERPA Reception Center A-2, A-5, A-10, K-10 West Limestone High School B-2, B-5, B-10 East Limestone High School A-5, A-10 Elkmont High School B-5, B-10 Ardmore High School F-2, G-2, F-5, G-5, F-10, G-10, H-10 Moulton Recreation Center E-5, D-10, E-10 Hartselle Junior High School C-10 Priceville School 1-10, J-10 Brooks High School Bro-s Ferry - ETE - VER9.doc-1-10
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 1-3 ETE Comparison ETE Element 2008 ETE Study Current Study Permanent residents Total population
- 44,100 45,776 Vehicle occupancy
- 2.45 (one vehicle per 2.06 (persons per vehicle) household)
Transit dependent It was assumed that privately Population estimate owned vehicles of friends and/or 690 persons, 43 disabled, 27 relatives would be available. One bed-ridden Number of vehicles vehicle would be made available to evacuate each household.
23 buses 15 wheelchair bus/van 14 ambulances Transient facilities (Winter day/summer weekday)
Estimated population
- 22,600 18,311/18,532 Vehicle demand Not explicitly provided in the 16,050/16,138 report. Vehicle Occupancy Adjust for double-count reotVhilOcuay Rates provided for different population types.
No adjustment Special facilities (Winter weekday)
Estimated population
- 17,630 (includes schools and 1,019 (schools and daycare not Number of buses, vans daycare) included)
- Assumed enough resources 57 buses ravailable 21 wheelchair buses 9 ambulances Schools (Winter weekday)
Student population
- 11,576 (daycare included) 11,197 (daycare included)
Number of buses Assumed enough resources 153 buses/13 vans available Background traffic None Average traffic by time of day Shadow evacuation None 20 percent of resident population (assumed basis) outside designated zones Special event(s)
None AYSA Soccer (Jack Allen Soccer Complex)
Scenarios
- Weekday, weeknight, weekend Weekday (winter, summer)
- Normal and adverse weather Weeknight (winter, summer)
Bros Ferry - ETE -VER9.docx 1-11
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 1-3 ETE Comparison ETE Element 2008 ETE Study Current Study Weekend (winter, summer)
Adverse weather weekday only Staged evacuation (weekday)
Adverse weather Snow or rain. Some reduction in Snow for winter, rain for summer capacities and speeds.
Evacuation model name and PTV Vision VISUM PTV Vision VISUM 11.5, VISSIM 5.3 version Departure times
- Warning based on literature Warning based on literature
- Residential based on survey Residential based on survey
- Transient based on survey Transient based on survey
- Specials notified with public Specials notified with public Evacuation times Estimates for 100 percent Estimates provided for 90 and 100 percent B~ws Ferry-ETE - VERg.doc 1-12
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 2.
Methodology and Assumptions 2.1 Sources of Data and General Assumptions The following data sources were reviewed and assumptions made to develop the appropriate population and roadway databases used for the evacuation analysis:
Population estimates for permanent residents were developed from 2010 U.S.
Census Bureau data.
Population estimates for seasonal residents were developed from 2010 U.S.
Census Bureau data on housing units. Census data identify the number of seasonal housing units (vacant housing units for "seasonal or occasional use") at different geographic levels (e.g., by township, census tract, block group, block). A conservative estimate of seasonal population was developed by assigning three persons and two vehicles per seasonal housing unit.
Population estimates for major employers were developed from the ESRI list and the facility list from the 2008 study report. ARCADIS conducted internet searches and obtained information from the Tennessee Valley Authority (TVA), Alabama Emergency Management Agency, and counties to estimate facility employment and staffing levels for various scenarios. Only facilities with potential staffing level of at least 50 persons per work shift were pursued.
Information relating to hotels, motels, and recreational facilities was obtained from tourism websites and the 2008 study report. For parks, visitation information was obtained from the counties.
Current population estimates for schools were obtained primarily from county emergency response agencies.
Lists of hospitals, rest homes, and incarceration facilities were obtained from each county emergency management agency.
The staffing levels at BFN reflect estimated peak personnel on site and were provided by TVA.
Brns Fey - ETE - VER9.docx 2-1
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Initial estimates of roadway characteristics were obtained from the NAVTEQ database. Roadway geometric and operational data were compiled based on field surveys performed by ARCADIS in 2012.
Average traffic volumes by time of day for weekdays and weekends for designated evacuation routes were obtained from state and county transportation agencies.
These data were used to assign background traffic volumes for the roadway network. It was assumed that access control would be established within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> following public notice to evacuate.
Preparation and mobilization times for the permanent resident population were developed based on the results of a telephone survey (Appendix E), combined with published time estimates for warning diffusion. The survey provided estimates of the time to depart from home following notification, and commuting times for household members who would return from work before departing.
Departure times for transient facilities were estimated assuming relatively prompt evacuation of most workplaces and recreational facilities after notification is received. The distribution of departure times also reflects information gathered from the telephone survey of EPZ residents, as discussed in Section 3.
The ETEs represent the time required to evacuate the Browns Ferry EPZ and designated analysis areas and include the time required for initial notification.
ETEs are presented for 90 percent and 100 percent of evacuating vehicles. It is assumed that all persons within the EPZ area will evacuate. For the 100 percent evacuation time, evacuation of the EPZ will be considered complete after all evacuating vehicles are outside of the EPZ or analysis area.
The general public will evacuate using designated evacuation routes and will proceed to the reception centers listed in Table 1-2 after leaving the EPZ. When schools are in session, children attending school will be transported directly to designated host schools.
It is assumed that existing lane utilization will prevail during the course of the evacuation. Traffic control signals will be overridden or converted to flashing mode, as necessary, to give preference to flow on all major outbound roadways. It is also assumed that state and municipal personnel will restrict unauthorized access into the EPZ, consistent with existing traffic management plans.
Browns Ferry - ETE - VER9.doox 2-2
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates The evacuation analysis cases are described in Section 2.3 and represent a range of conditions, in accordance with guidance presented in CR-7002. These cases have been chosen to provide information for an appropriate range of conditions (i.e., low, typical, and high population; fair and adverse weather) to guide the protective action decision-making process.
Vehicle occupancy rates used for the various population categories are as follows:
Permanent residents: 2.06 persons per vehicle, based on telephone survey results Major places of employment: 1 vehicle per employee Motels: 1 vehicle (1 to 2 persons) per occupied room Recreational areas: 1 vehicle (3 persons) per campsite; 1.5 persons per vehicle at shopping malls, visitor centers and museums Schools: 55 students and 3 staff per bus; 1 vehicle per additional staff person Hospitals/nursing homes/correctional facilities: 2 persons per ambulance/medical van for non-ambulatory patients and 20 persons per bus or van for ambulatory residents Transit dependent general population: 28 persons per bus for ambulatory residents (50 percent of the 55 persons assumed for schools), 2 per ambulance or 3 per wheelchair (WC) bus/van for non-ambulatory.
The transit dependent population will be evacuated by bus, wheelchair bus, van or ambulance through efforts coordinated by state and municipal emergency preparedness officials.
Adverse weather refers to moderate to heavy rainstorms for summer conditions, and a moderate snowstorm for winter conditions.
2.2 Interaction with Agencies Emergency management agencies responsible for planning and implementing the emergency response procedures during a radiological emergency were consulted during the development of this ETE study. The Alabama Emergency Management Agency (AEMA) and emergency agencies for Limestone, Lauderdale, Lawrence, and Morgan Counties were contacted to obtain information regarding special and transient facilities in the EPZ, transportation resources available to evacuate special facilities, and the transit dependent general public. AEMA and the county agencies reviewed the draft report and the facility databases used in this study. Representative background traffic volumes for the EPZ roadway network were obtained from state and county transportation agencies.
Browns Ferry - ETE -VER9.doc2 2-3
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates 2.3 Summary of Methodology for Traffic Simulation The ETEs developed for the Browns Ferry EPZ are based upon a time distribution of evacuation events as opposed to a summation of sequential events. This methodology assumes that the various time components in an evacuation (e.g., the time associated with preparation, mobilization) overlaps and occurs within certain time ranges. The time distribution approach is based upon assumptions consistent with the NRC guidance of CR-7002.
Trip generation times are used to develop vehicle loading curves for different population types within the permanent, transient, and special facility populations. A trip generation time consists of two main components: warning diffusion time and mobilization time. Warning diffusion time is the time it takes for people to receive an emergency notification. The type of warning systems employed in the EPZ, such as an emergency alert system (EAS), sirens, and tone alert radios (TARs), affects the distribution of warning times. Availability of more warning systems leads to faster warning diffusion to the public.
Mobilization time is the time between the receipt of notification and when individuals leave for evacuation. Mobilization time depends on the type of population and activity.
Warning diffusion time and mobilization time distributions are used to develop composite loading distribution or trip generation curves for different population segments. Trip generation times for transit-dependent facilities, special facilities, and schools were developed separately from those for the general public.
2.4 Conditions Modeled Pursuant to the guidance in CR-7002 and NUREG-0654, Rev. 1, ETEs have been prepared for a range of temporal, seasonal, and weather conditions. Estimates have been prepared for weekday, weeknight, and weekend scenarios during winter and summer. All scenarios are simulated with fair weather conditions; weekday scenarios are also simulated assuming adverse weather. Fair weather refers to conditions where roadways are clear and dry and visibility is not impaired. Adverse weather during summer periods is defined as a rainstorm condition where visibility is impaired and roadway capacities and speeds are reduced by 10 percent and 15 percent, respectively. Adverse weather during winter periods is defined as a snowstorm condition where roadway capacities and speeds are reduced by 15 percent and 35 percent, respectively.
Bro-,s Feny - ETE -VER9.doc-2-4
V ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates The various population components that have been incorporated in the evacuation scenarios are summarized below.
2.4.1 Weekday This situation represents a typical weekday period with the workforce at a full daytime level. During winter, schools are in session. Vehicle demand estimates for weekday scenarios reflect the following conditions:
Most permanent residents within the EPZ will evacuate from their places of residence.
Major work places are fully staffed at typical daytime levels.
BFN employment is at an estimated peak daytime level, representative of operation during outage conditions.
Schools and daycares are at current enrollment.
Hospitals and nursing homes are at current enrollment or typical occupancy.
Motel facilities are occupied at peak (winter or summer) levels.
Recreational facilities are at winter or summer weekday levels.
2.4.2 Weeknight This situation reflects a typical night period when most permanent residents are home and the workforce is at evening shift level. Assumptions of the population levels for this condition include the following:
Permanent residents within the EPZ will evacuate from their places of residence.
Major work places are at typical evening levels.
BFN employment is at an estimated peak nighttime level.
Day schools and daycares are closed.
Brwns Ferry - ETE -VER9.doc2 2-5
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Hospitals and nursing homes are at current enrollment or typical occupancy, and staffing is at typical nighttime levels.
Motel facilities are occupied at (winter or summer) weekday levels.
Recreational facilities are at typical (winter or summer) evening levels.
2.4.3 Weekend The weekend scenario represents a daytime period when most residents are at home and major work places are at typical weekend levels. Assumptions of the population levels for this condition include the following:
Residents within the EPZ will evacuate from their places of residence.
Major work places are at typical weekend levels.
Day schools and daycares are closed.
Hospitals and nursing homes are occupied and staffed at weekend levels.
Motel facilities are occupied at weekend (winter or summer) levels.
Recreational facilities are at (winter or summer) weekend levels.
Brows Ferry - ETE - VER9.doco 2-6
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 3.
Population and Vehicle Demand Evaluation The development of vehicle demand estimates for the Browns Ferry EPZ consisted of two primary steps. The first step was the determination of the number and distribution of the population to be evacuated. The second step was the determination of the appropriate number of vehicles for each of the population categories. Federal guidance (CR-7002) indicates that three population categories should be considered:
permanent residents, transients, and persons in schools and special facilities (such as medical facilities/nursing homes and daycare facilities).
The methodology used to develop the total population and vehicle demand estimates within the Browns Ferry EPZ incorporates intrinsic double-counting. For example, a portion of the identified employees and visitors to recreational areas are also permanent residents within the EPZ. In addition, school children are counted in the resident population, but are also counted in the special facility population. While population and vehicle demand estimates incorporate some adjustments for double-counting, the estimates are considered to be conservative (i.e., they overestimate actual population and vehicle levels that may be in the area at any given time).
Population and vehicle demand estimates for each of the population categories are summarized below.
3.1 Permanent Residents Permanent residents are those persons identified by the census as having a permanent residence within the EPZ. The 2010 U.S. Census population data for census tracts, block groups, and blocks were used to determine the permanent resident population within the EPZ and within each municipality and ERPA. The allocation of the resident population to entry nodes on the roadway network was based on detailed census block maps.
An estimated 45,776 persons reside permanently within the Browns Ferry EPZ.
Table 3-1 presents the resident population and vehicle demand by ERPA.
3.1.1 Auto-Owning Permanent Population Vehicle demand associated with the permanent resident population was estimated based on telephone survey responses (Appendix E). The estimated occupancy factor is 2.06 persons per vehicle, which corresponds to 1.39 vehicles per household. Total vehicle demand for EPZ residents for winter scenarios is 22,222.
Br s Ferny - ETE -VER9.doc 3-1
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates For the 2008 ETE study, evacuation times were determined for vehicle demand assumption of one vehicle per household, or 2.45 persons per vehicle, for permanent residents during a weekday.
3.1.2 Transit Dependent Permanent Population Emergency response plans specify that the transit dependent population will receive transportation assistance. The Limestone, Lawrence, Lauderdale, and Morgan County Radiological Emergency Response Plans include provisions for providing this assistance to a small number of identified individuals within the EPZ. None of the households surveyed for the telephone questionnaire were without vehicles or licensed drivers. However, NRC guidance (CR-7002) indicates that a range of 3 to 10 percent of residents may require transportation and that up to half of those residents without an available vehicle plan to evacuate with friends or neighbors. Given this data, the transit dependent population estimate is based on a conservative 1.5 percent value of the total permanent resident population, which represents about 690 residents.
Approximately 70 of these individuals will require a wheelchair van or ambulance to evacuate, according to data provided by the county agencies.
3.2 Seasonal Residents The seasonal population category addresses those who reside in the EPZ on a temporary basis, particularly during the summer period. The 2010 U.S. Census of Population and Housing reports the number of vacant households classified as "for seasonal or occasional use." Census data identified 645 such housing units in the Browns Ferry EPZ, including 335 in ERPA K-10. Population and vehicle demand were estimated assuming three residents and two vehicles per household.
3.3 Transient Population The transient population segment includes persons in the workforce, hotels/motels, and recreational areas. Regional maps and mapping software were used to determine facility locations and assign entry nodes. Significant employers within the EPZ were identified using ESRI Business Analyst Online (BAO). BAO is a web-based analytical and mapping tool that facilitates location-specific queries about business and demographic data. Data available on BAO includes information on business location and number of employees. ESRI extracts business data from a comprehensive list of businesses (more than 12 million U.S. businesses) licensed from Infogroup. ARCADIS used BAO to search for all employers with 50 or more employees located within a 10-Bros Ferry - ETE -VER9.doc3 3-2
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates mile radius of BFN. CR-7002 recommends consideration of "large employers" with 50 or more employees on a single shift.
The list from BAO was screened to eliminate businesses where workers do not remain on site (e.g., transportation and trucking companies, construction, real estate agents, home health care). Employment at schools and special facilities (e.g., hospitals, nursing homes) is generally tracked as part of the special facilities database. The reduced list was then reviewed to exclude facilities located outside the EPZ, and to determine the ERPA for those located in the EPZ. The new list of employers was compared to the list from the 2008 study and the information provided by the county Emergency Management Agencies.
Telephone calls were made to selected large employers to verify employment numbers and to estimate staffing levels during weekday, weeknight, and weekend periods.
Workforce numbers for BFN were provided by TVA and reflect the peak workforce during outage conditions.
Numbers of units and campsites for motels and recreational areas were obtained from the TripAdvisor website and state and county tourism websites. Seasonal occupancy was estimated based on capacity figures (e.g., number of campsites) and a telephone survey of selected facilities. County agencies also provided visitation numbers for parks and campgrounds.
For purposes of estimating the total number of vehicles associated with the transient population segment, an occupancy factor of 1.0 employee per vehicle was used for most work places. For the hotel/motel and recreational populations, 1.0 vehicle (1.5 persons) per hotel/motel unit was assumed. For parks and campgrounds, 1.0 vehicle (3 persons) per campsite was assumed. Daytime park visitation numbers were generally obtained as numbers of vehicles, and an occupancy factor of 1.5 persons per vehicle was assumed. Campgrounds were assumed to be fully occupied during summer. Motels were assumed to be fully occupied for all scenarios.
Vehicle demand for selected recreational facilities was reduced in consideration of double-counting. These facilities include recreational clubs and other facilities that would be used predominantly by those residing within 10 to 20 miles. An adjustment factor of 0.75 was applied, assuming that (a) roughly half of visitors reside in the EPZ and (b) roughly half of EPZ residents would return home before evacuating. Similar adjustments were made for shopping centers and large retail outlets.
Brows Ferry - ETE -VER9.docx 3-3
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates As a supplement to the BAO analysis, a database of employers maintained by the Census Bureau (Longitudinal Employer-Household Dynamics, or LEHD) was also utilized to estimate the number of persons working within the EPZ. The total workforce in each ERPA, as indicated by LEHD, was compared to the total workforce estimated from facility-based data, including employers, schools and daycares, health care institutions, retailers, and recreation facilities. Transient population was added for ERPAs where LEHD numbers were significantly higher than facility-based numbers.
The total LEHD adjustment for all scenarios was 8,479. Seventy-five percent of the LEHD adjustments were added to the weekday transient population, 15 percent to evening, and 10 percent to the weekend population. The largest adjustments were made to ERPAs A-10 and B-10. The LEHD adjustments represent approximately 35 percent of the transient population for the winter weekday scenario.
Table 3-2 presents a summary of the transient population by ERPA for each scenario.
The transient population and associated vehicle demand are greatest for summer weekday and winter weekday scenarios. Recreational facilities are located in ERPAs A-10, 1-10, J-10, and K-10, along the Elk River and in ERPAs G-2, B-5, F-5, C-10, and K-10, along Wheeler Lake. ERPA D-10 has the highest population and vehicle demand from transient facilities, reflecting a combination of employers, motels, and retail and recreational facilities. Population data and vehicle demand estimates for the transient population segment, including the workforce, hotels and motels, and recreational areas, are presented by facility in Appendix B.
3.4 Special Facilities Population The special facility population segment includes persons in schools, hospitals, nursing homes, and correctional facilities who will require transportation assistance during an evacuation. Most school facilities are located in the ERPAs with large residential populations. The special facilities population is summarized by ERPA in Table 3-3; data by facility is provided in Appendix B.
3.4.1 Medical, Nursing Care, and Correctional Facilities The EPZ has one hospital, in Decatur, and two nursing home facilities. Vehicle occupancy for nursing home patients is two non-ambulatory patients and one staff per ambulance, 20 residents or patients plus 3 staff per vehicle (bus or van) for ambulatory patients, plus 1 vehicle per staff person who does not evacuate with patients.
Bros Ferry - ETE -VER9.doc3 3-4
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates 3.4.2 Schools and Daycare Twenty elementary and secondary schools and 12 pre-school/daycare facilities have been identified within the Browns Ferry EPZ, with a total population of 11,197 students.
None of the identified schools is residential; therefore, students are only present on weekdays during the school year. Vehicle occupancy for public schools is based on 58 persons (55 students, 3 staff) per bus, plus 1 vehicle per additional school staff.
The 12 licensed childcare (large daycare) facilities have an estimated daytime population of 1,198 students and staff. Those facilities were identified from an internet listing of licensed childcare establishments. The population estimates represent the licensed capacity of each facility. Smaller home-based daycare facilities (capacity 10 or less) were not tabulated; those facilities contribute little vehicle demand beyond that assigned to EPZ residents.
3.5 Emergency Response Planning Area Population Totals Population and vehicle demand totals for each ERPA are summarized in Table 3-4.
The totals listed in the table represent the peak number of people to be evacuated for each analysis case discussed in Section 6 of this report.
Vehicle demand is highest for the winter weekday scenario. Vehicle demand for the highest scenario is 34 percent higher than the lowest (winter weeknight) scenario.
ERPA D-10, near Decatur, has the largest population and vehicle demand for all scenarios. The vehicle demand listed in Tables 3-2, 3-3, and 3-4 reflects the data used as input for the ETE traffic simulations.
3.6 Transportation Resources The estimated inventory of transportation resources available to support evacuation of special facilities and residents for the Browns Ferry EPZ was determined from information provided by county agencies, plus data developed by surveying school systems, transportation companies and EMS providers in the surrounding region.
Identified transportation resources are summarized and compared to the estimated vehicle demand in Table 3-5. The number of available vehicles in each category (bus, wheelchair bus or van, ambulance) is more than sufficient to evacuate facilities and EPZ residents in a single wave. The largest supply of available transportation resources comes from Lauderdale County.
Browns Feny - ETE - VER9.dc3x 3-5
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 3-1 Resident Population and Vehicle Demand by EPZ Subarea Seasonal Permanent (summer)
Resident Vehicle Demand Resident Vehicle Demand ERPA Distance Population (winter)
Population (summer)
A-2 0 to 2 miles 218 106 296 155 B-2 0 to 2 miles 216 105 220 108 F-2 0 to 2 miles 7
3 7
3 G-2 0 to 2 miles 77 37 104 54 A-5 2 to 5 miles 1,757 853 1,851 911 B-5 2 to 5 miles 646 314 646 314 E-5 2 to 5 miles 97 47 99 48 F-5 2 to 5 miles 221 107 221 107 G-5 2 to 5 miles 183 89 185 90 A-10 5 to 10 miles 8,857 4300 8,895 4324 B-10 5 to 10 miles 6,166 2993 6,184 3004 C-10 5 to 10 miles 4,149 2014 4,151 2015 D-10 5 to 10 miles 13,017 6319 13,064 6348 E-10 5 to 10 miles 2,972 1443 2,985 1451 F-10 5 to 10 miles 3,036 1474 3,054 1485 G-10 5 to 10 miles 671 326 675 329 H-10 5 to 10 miles 126 61 128 62 1-10 5 to 10 miles 520 252 740 388 J-10 5 to 10 miles 202 98 325 174 K-10 5 to 10 miles 2,638 1281 3,388 1747 EPZ total 45,776 22,222 47,218 23,117 Browns Ferry -ETE - VER9.doc6 3-6
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 3-2 Transient Population and Vehicle Demand within the Browns Ferry EPZ Population Vehicles ERPA Winter Summer Winter Summer Day Night Weekend Day Night Weekend Day Night Weekend Day Night Weekend A-2 978 231 63 978 231 63 978 231 63 978 231 63 B-2 0
0 0
0 0
0 0
0 0
0 0
0 F-2 0
0 0
0 0
0 0
0 0
0 0
0 G-2 220 100 220 441 200 441 88 40 88 176 80 176 A-5 0
0 0
0 0
0 0
0 0
0 0
0 B-5 144 144 144 144 144 144 72 72 72 72 72 72 E-5 1,718 230 187 1,718 230 187 1,718 230 187 1,718 230 187 F-5 0
0 0
0 0
0 0
0 0
0 0
0 G-5 0
0 0
0 0
0 0
0 0
0 0
0 A-10 1,689 333 260 1,689 333 260 1,669 333 240 1,669 333 240 B-10 2,918 875 421 2,918 875 421 2,918 875 421 2,918 875 421 C-10 4,676 536 1,018 4,676 536 1,018 4,331 516 673 4,331 516 673 D-10 4,839 3,947 3,881 4,839 3,947 3,881 3,402 2,185 2,119 3,402 2,185 2,119 E-10 619 114 76 619 114 76 619 114 76 619 114 76 F-10 0
0 0
0 0
0 0
0 0
0 0
0 G-10 0
0 0
0 0
0 0
0 0
0 0
0 H-10 0
0 0
0 0
0 0
0 0
0 0
0 1-10 80 0
80 80 0
80 40 0
40 40 0
40 J-10 130 0
130 130 0
130 65 0
65 65 0
65 K-10 300 186 300 300 186 300 150 87 150 150 87 150 EPZtotal 18,311 6,696 6,780 18,532 6,796 7,001 16,050 4,683 4,194 16,138 4,723 4,282 Brows Ferry - ETE - VER9.doc3 3-7
ARCADIS Table 3-3 Population and Vehicle Demand for Schools and Special Facilities in the Browns Ferry EPZ Population Vehicles ERPA Winter Summer Winter Summer Day Night Weekend Day Night Weekend Day Night Weekend Day Night Weekend A-2 0
0 0
0 0
0 0
0 0
0 0
0 B-2 0
0 0
0 0
0 0
0 0
0 0
0 F-2 0
0 0
0 0
0 0
0 0
0 0
0 G-2 0
0 0
0 0
0 0
0 0
0 0
0 A-5 0
0 0
0 0
0 0
0 0
0 0
0 B-5 0
0 0
0 0
0 0
0 0
0 0
0 E-5 0
0 0
0 0
0 0
0 0
0 0
0 F-5 0
0 0
0 0
0 0
0 0
0 0
0 G-5 0
0 0
0 0
0 0
0 0
0 0
0 A-10 1,095 200 200 472 200 200 206 42 42 131 42 42 B-IO 1,853 0
0 119 0
0 298 0
0 9
0 0
C-10 906 145 145 214 145 145 98 18 18 43 18 18 D-1O 3,858 418 418 1,100 418 418 1,236 183 183 425 183 183 E-10 1,566 0
0 72 0
0 303 0
0 6
0 0
F-1O 1,743 0
0 0
0 0
168 0
0 0
0 0
G-10 0
0 0
0 0
0 0
0 0
0 0
0 H-10 0
0 0
0 0
0 0
0 0
0 0
0 1-10 0
0 0
0 0
0 0
0 0
0 0
0 J-10 0
0 0
0 0
0 0
0 0
0 0
0 K-10 1,195 0
0 0
0 0
303 0
0 0
0 0
EPZ total 12,216 763 763 1,977 763 763 2,612 243 243 614 243 243 Browns Ferry Nuclear Power Plant Evacuation Time Estimates B-sFey
- ETE -VER9.doc8 3-8
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 3-4 Summary of Population and Vehicle Demand within the Browns Ferry EPZ Population Vehicles ERPA Winter Summer Winter Summer Day Night Weekend Day Night Weekend Day Night Weekend Day Night Weekend A-2 1,196 449 281 1,274 527 359 1,074 337 169 1,123 386 218 B-2 216 216 216 220 220 220 95 105 105 98 108 108 F-2 7
7 7
7 7
7 3
3 3
3 3
3 G-2 297 177 297 545 304 545 122 77 125 227 134 230 A-5 1,757 1,757 1,757 1,851 1,851 1,851 773 853 853 831 911 911 B-5 790 790 790 790 790 790 357 386 386 357 386 386 E-5 1,815 327 284 1,817 329 286 1,761 277 234 1,762 278 235 F-5 221 221 221 221 221 221 97 107 107 97 107 107 G-5 183 183 183 185 185 185 81 89 89 82 90 90 A-10 11,641 9,390 9,317 11,056 9,428 9,355 5,773 4,675 4,582 5,722 4,699 4,606 B-10 10,937 7,041 6,587 9,221 7,059 6,605 5,929 3,868 3,414 5,651 3,879 3,425 C-10 9,731 4,830 5,312 9,041 4,832 5,314 6,255 2,548 2,705 6,201 2,549 2,706 D-10 21,714 17,382 17,316 19,003 17,429 17,363 10,366 8,687 8,621 9,584 8,716 8,650 E-10 5,157 3,086 3,048 3,676 3,099 3,061 2,230 1,557 1,519 1,941 1,565 1,527 F-10 4,779 3,036 3,036 3,054 3,054 3,054 1,504 1,474 1,474 1,347 1,485 1,485 G-10 671 671 671 675 675 675 296 326 326 299 329 329 H-10 126 126 126 128 128 128 55 61 61 56 62 62 1-10 600 520 600 820 740 820 268 252 292 404 388 428 J-10 332 202 332 455 325 455 154 98 163 230 174 239 K-10 4,133 2,824 2,938 3,688 3,574 3,688 1,614 1,368 1,431 1,777 1,834 1,897 EPZ total 76,303 53,235 53,319 67,727 54,777 54,982 38,807 27,148 26,659 37,792 28,083 27,642 Population numbers reflect some double-counting between categories (e.g., residents, workforce, schools).
Bo.s Ferry - ETE -VER9.do-9 3-9
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 3-5: Summary of Transportation Resources County Bus Van WC Bus WC Van Ambulance Limestone 4
1 2
1 9
Lauderdale 95 50 0
7 10 Lawrence 94 1
11 0
5 Morgan 67 4
25 2
16 Total Available 260 56 38 10 40 Identified Vehicle Need Schools and Day Care 153 13 0
0 0
Special Facilities 57 0
21 0
9 Transit Dependent Public 23 0
8 7
14 Total Identified Need 223 13 29 7
23 Browns Ferry - ETE -VER9.doc3 3-10
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 4.
Evacuation Roadway Network 4.1 Network Definition An evaluation of the roadway network likely to be used by departing vehicles was undertaken to estimate evacuation times for the Browns Ferry EPZ. ARCADIS relied on several sources of information to define the evacuation roadway network:
Evacuation routes described in the existing county emergency response plans and public information calendars Maps of highways and local roadways for the EPZ area A field survey of the roadways in the Browns Ferry EPZ The primary evacuation routings used in the modeling are shown on Figure 4-1.
4.2 Evacuation Route Descriptions The evacuation routings were developed to simulate travel out of the EPZ using available roadways. The network relies primarily on the evacuation routings depicted in the public information brochure. Descriptions of the primary evacuation routes for different geographic areas within the EPZ are outlined in Table 4-1.
4.3 Characterizing the Evacuation Network Roadway characteristics, such as roadway class, number of lanes, lane and shoulder width, speed limit, lane configuration near intersections, and traffic control, are key factors in determining how fast an evacuation can be completed. These roadway attributes control roadway capacity, which in turn governs operating traffic conditions measured in terms of level of service (LOS). LOS is measured from A to F for roadway segments and intersections. LOS A represents free-flow conditions, and LOS F represents force or breakdown flow conditions.
ARCADIS used NAVTEQTM roadway data with detailed information, including local streets, to build the evacuation roadway network for the study. NAVTEQ data were imported into geographic information system (GIS) software (ESRI ArcGISTM) for conducting field surveys to verify evacuation roadway segment attributes. The information provided in the public outreach calendar for the site was used to highlight br*ows ferry - ete -ver9.docx 4-1
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates evacuation routes in GIS. ARCADIS has developed an integrated GIS-global positioning system tool that allows field personnel to record observations in an efficient and effective manner. The evacuation network, including traffic controls, was verified to a 15-mile radius from the plant, and along designated routes to the reception centers.
After the NAVTEQ data were verified through the field survey, the evacuation roadway network was transferred to the traffic simulation software VISUM for modeling different evacuation scenarios.
Having accurate traffic control information is important to accurately estimate evacuation times because intersections have the potential to create bottleneck points.
During an evacuation scenario, intersections might be manually controlled by officials, operated with existing traffic signal timing plans, or adjusted according to changing vehicular demand. In general, the emergency response plans for Browns Ferry call for signal override (i.e., signals set to flashing to give priority to outbound travel on designated evacuation routes). Traffic control information is coded as part of the evacuation network database.
Background and pass-through traffic in the EPZ could account for a significant number of vehicles and could influence evacuation depending on the direction of travel. As recommended in CR-7002, average daily traffic (ADT) volumes, representative of typical background levels, were obtained from state and county transportation agencies. During simulations, background traffic will be included during the initial 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the evacuation scenario, up to the time when access control is established to prevent vehicles from entering the EPZ.
A map of the evacuation network showing node numbers and links, as recommended by the latest guidance, is provided in Appendix D. Detailed attributes of each roadway segment, such as link number, number of lanes, speed limit, length, and roadway type, are also tabulated in Appendix D.
bros ferry - ete -ver9.docx 4-2
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 4-1 Browns Ferry EPZ Primary Evacuation Routes Out of EPZ EPZ Subareas Evacuation Routes A-2 (Limestone Proceed north and follow the Evacuation Route signs to the Reception Center at County)
West Limestone High School.
B-2 (Limestone Proceed east and follow the Evacuation Route signs to the Reception Center at County)
East Limestone High School.
A-5 (Limestone Proceed north and follow the Evacuation Route signs to the Reception Center at West Limestone High School or proceed northeast to the Reception Center at County)
Elkmont High School.
B-5 (Limestone Proceed east and follow the Evacuation Route signs to the Reception Center at Coun etoe East Limestone High School or proceed northeast to the Reception Center at County)
Ardmore High School.
A-10 (Limestone Proceed north and follow the Evacuation Route signs to the Reception Center at A-ou etoe West Limestone High School or proceed northeast to the Reception Center at County)
Elkmont High School.
B-10 (Limestone Proceed east and follow the Evacuation Route signs to the Reception Center at BCou etoe East Limestone High School or proceed northeast to the Reception Center at County)
Ardmore High School.
K-10 (Limestone Proceed north and follow the Evacuation Route signs to the Reception Center at County)
West Limestone High School.
Take shortest route to State Highway 20 (Alternate U.S. 72). Go west on State F-2, F-5 Highway 20 to County Road 217 to State Highway 24. Go west on State (Lawrence Highway 24 to State Highway 157, south on State Highway 157 to Court Street, County) west on Court Street. Follow instructions of traffic control personnel to the Moulton Recreation Center.
Travel south to State Highway 20. Go west on State Highway 20 to County G-2 (Lawrence Road 217, south on County Road 217 to State Highway 24, west on State County)
Highway 24 to State Highway 157. Go south on State Highway 157 to Court Street. Turn west on Court Street to the Moulton Recreation Center.
Take the most direct route to County Road 400, then proceed east on County G-5 (Lawrence Road 400 to State Highway 20. Go west on State Highway 20 to County Road 217, south on County Road 217 to State Highway 24, west on State Highway 24 County) to State Highway 157, where you will be directed to the Moulton Recreation Center.
F-10 (Lawrence Travel south to State Highway 24. Go west on State Highway 24 to State County)
Highway 157. Turn south on State Highway 157. Follow instructions of traffic control personnel to the Moulton Recreation Center.
G-10 (Lawrence Travel to State Highway 20. Go west on State Highway 20 to State Highway 33, County) then south on State Highway 33 to the Moulton Recreation Center.
Proceed west to County Road 400, then south on County Road 400 to County H-10 (Lawrence Road 389. Go south on County Road 389 to State Highway 20, east on State County)
Highway 20 to State Highway 33, south on State Highway 33 to the Moulton Recreation Center.
Travel south on Finley Island Road or east on State Highway 20 to Woodall E-5 (Morgan Road, then south to Modaus Road. Go east on Modaus Road to State Highway County) 67, east on State Highway 67 to U.S. Highway 31, south on U.S. 31 to Hartselle Junior High School.
broms ferry -ete - ve-9.doc4 4-3
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates EPZ Subareas Evacuation Routes C-10 (Morgan Travel east on State Highway 20 or 24 to U.S. Highway 31. Go south on County)
Highway 31 to State Highway 67, then east on Highway 67 to Priceville School.
Take shortest route to either Danville Road or Old Moulton Road to State D-10 (Morgan Highway 67. Go east on State Highway 67 to U.S. Highway 31, south on U.S.
County)
Highway 31 to Hartselle Junior High School.
Travel east on State Highway 24 to Woodall Road, south on Woodall Road to E-10 (Morgan Modaus Road, then east to State Highway 67. Go east on State Highway 67 to County)
U.S. Highway 31, then south on U.S. Highway 31 to Hartselle Junior High School.
1-10 (Lauderdale Take County Road 91, County Road 70, and County Road 77 to U.S. Highway County)
- 72. Proceed west to Brooks High School in Killen.
J-10 (Lauderdale Take County Road 70 to U.S. Highway 72 West to Brooks High School in Killen.
County) br~os ferry - ete -ver9docx4 4-4
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 5.
Evacuation Time Estimate Methodology 5.1 Evacuation Analysis Cases Time estimates have been prepared for a general evacuation scenario for each of these analysis cases:
Winter Weekday, Fair Weather, and Adverse Weather Conditions Winter Weeknight, Fair Weather Conditions Winter Weekend, Fair Weather Conditions Summer Weekday, Fair Weather, and Adverse Weather Conditions Summer Weeknight, Fair Weather Conditions Summer Weekend, Fair Weather Conditions Areas for evacuation are selected based on the "keyhole" configuration (0 to 2-mile zone plus 2 to 5 miles or 0 to 5 miles plus 5-to 10-mile downwind zone). The partial-EPZ evacuation areas for BFN are reproduced in Table 5-1, based on the Protective Action Response (PAR) chart. Separate simulations may not be necessary for each of the areas listed in Table 5-1. ETEs will generally be controlled by whether one or two critical ERPAs (e.g., ERPAs A-10 and B-10) are included. Enough cases will be run to confirm that representative ETEs are obtained for all potential scenarios.
For partial-EPZ evacuation cases, "shadow" vehicle demand (20 percent of residents) is assigned to all ERPAs that are not included in the evacuation region, in addition to the region outside of the EPZ.
browns ferry - ete - ver9.docx 5-1
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 5-1 Potential Evacuation Areas for Browns Ferry EPZ AreaIWind Direction (from)
EPZ Subareas/ERPAs 2-mile ring A-2,B-2,F-2,G-2 5-mile ring A-2,B-2,B-5,E-5,F-2,F-5,G-2,G-5 Full EPZ All ERPAs 2-mile radius and 5 miles downwind NNW-N A-2,B-2,E-5,F-2,F-5,G-2 NNE-ENE A-2,B-2,F-2,F-5,G-2, G-5 E-ESE A-2,B-2,F-2,G-2,G-5 SE A-2,A-5,B-2,F-2,G-2,G-5 SSE-S A-2,A-5,B-2,F-2,G-2 SSW-WSW A-2,A-5,B-2,B-5,F-2,G-2 W
A-2,B-2,B-5,F-2,G-2 WNW-NW A-2,B-2,B-5, E-5,F-2,G-2 5-mile radius and 10 miles downwind NNW-N A-2,A-5,B-2,B-5,C-10,D-10,E-5,E-10,F-2,F-5,F-10,G-2,G-5 NNE A-2,A-5,B-2,B-5,E-5,E-10,F-2,F-5,F-10,G-2,G-5,G-10 NE-ENE A-2,A-5,B-2,B-5,E-5,F-2,F-5,F-10,G-2,G-5,G-10, H-10 E
A-2,A-5,B-2,B-5,E-5,F-2,F-5,G-2,G-5,G-10,H-10 ESE-SE A-2,A-5,B-2,B-5,E-5,F-2,F-5,G-2,G-5,H-10,1-10,J-10,K-10 SSE A-2,A-5,A-10,B-2,B-5,E-5,F-2,F-5,G-2,G-5,1-10,J-10,K-10 S
A-2,A-5,A-10,B-2,B-5,E-5,F-2,F-5,G-2,G-5,K-10 SSW A-2,A-5,A-10,B-2,B-5,B-10,E-5,F-2,F-5,G-2,G-5,K-10 SW-WSW A-2,A-4,A-10,B-2,B-5,B-10,E-5,F-2,F-5,G-2,G-5 W
A-2,A-5,B-2,B-5,B-10,E-5,F-2,F-5,G-2,G-5 WNW A-2,A-5,B-2,B-5,B-10,C-10,D-10,E-5,F-2,F-5,G-2,G-5 NW A-2,A-5,B-2,B-5,B-10,C-10,D-10,E-5,E-10,F-2,F-5,G-2,G-5 browns ferry - ete - ver9.docx 5-2
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates 5.2 Initial Notification The EPZ surrounding BFN has an outdoor siren notification system consistent with the requirements of NUREG-0654, Rev. I/FEMA-REP-1 Appendix 3. This system will be used by state and local officials to alert the population to turn on their radios and television sets. Pursuant to NUREG 0654, Rev. 1 guidance, notification messages will commence on the designated EAS television and radio stations concurrent with sounding of the sirens and tone alert radios. Within 15 minutes of alert notification, essentially all of the population within the EPZ will begin to receive an informational or instructional message. If evacuation is deemed necessary, the timing of the order to evacuate and notification measures will be controlled by the state and local emergency preparedness officials. Those officials may choose to alert and mobilize an emergency response workforce to control and expedite evacuation prior to the evacuation order.
5.3 Transportation-Dependent Population The transportation-dependent population includes individuals without access to transportation, as well as those requiring special transportation assistance.
Transportation-dependent persons will be notified of a protective action recommendation in the same manner as the general public. If evacuation is recommended, persons needing transportation assistance will be informed through the EAS to contact the appropriate officials for assistance. Evacuees who do not have access to transportation and confined persons who require special transportation assistance will be provided transportation by the appropriate agency.
5.4 Evacuation Preparation Times and Departure Distributions It is assumed that no vehicles will begin to evacuate during the 15-minute initial notification period. Accordingly, in the model simulations, vehicles will begin to evacuate at 15 minutes following the initial notification. After the initial 15-minute time period, vehicles are loaded at a linear rate over each 5-minute time interval, in accordance with the network loading distributions for each population type. For example, if 2 percent of 2,500 vehicles (50 vehicles) are to be loaded at a specific location over a 5-minute period, PTV Vision will load 10 vehicles per minute at that location during the specified interval. Network loading distribution assumptions for the permanent population, transient population, and special facilities are based on the anticipated response of different population sectors to an evacuation order.
Mobilization times for residents and workers reflect the data acquired by the telephone bro s fenry - ete -ve-9.don-5-3
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates survey of EPZ residents, and are consistent with published data from actual historical events. Loading distributions are explained below and summarized on Figure 5-1.
5.4.1 Permanent and Seasonal Population Permanent and seasonal residents with access to automobiles will take varying amounts of time to begin evacuating. Some persons will leave as quickly as possible; most will take some time to prepare, pack valuables and clothes, and then depart; some will take added time to secure property before departing; and some may require transportation assistance. In addition, actual departure and preparation times may vary according to the perceived severity of a particular evacuation order.
Based on these factors, it was assumed that there would be a period of up to 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> over which the permanent residents would begin to evacuate. That is, permanent resident households would begin to evacuate between 15 and 180 minutes after the decision to notify the population to evacuate is made. Based on estimated warning diffusion and survey results from EPZ residents, during a weekday, 50 percent would depart within 60 minutes, 90 percent within 100 minutes, and 99 percent within 125 minutes. At night, 50 percent would depart within 65 minutes, 90 percent within 105 minutes, and 99 percent within 160 minutes. These time profiles are generally consistent with observed behavior during evacuations for chemical releases.
5.4.2 Transient Population It was assumed that the workforce would be subject to the same warning diffusion as the general public. Based on estimated warning diffusion and survey results from EPZ residents, it was estimated that 50 percent of the workforce would evacuate within 35 minutes following the decision to evacuate, 90 percent within 60 minutes, and 99 percent within 110 minutes. For a few facilities, it may be necessary for a limited number of workers to remain on the job in order to safely shut down processes, secure the facility, or maintain essential operations. The evacuation time estimates do not address those workers who remain behind, because there is no reliable basis for predicting whether or how soon they will evacuate. The assumption that all workers evacuate provides a conservative estimate of vehicle demand. Discussions with emergency preparedness officials indicate that the same time distribution is also reasonable for the other transient population categories within the EPZ, including motels and recreation areas.
brows ferry - ete -ve,.dox 5-4
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates 5.4.3 Special Facilities It was assumed that special facilities (i.e., schools, nursing homes) within the EPZ would also receive initial notification promptly. Based on data obtained from previous studies, vehicle departure times were developed that reflect a distribution of notification, preparation, and mobilization times.
Consistent with the current off-site emergency response plans, it was assumed that schools will be evacuated via bus to the designated host schools. For school facilities, it was assumed that up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> may be required to assemble buses, transport vehicles to schools, and load students onto buses. Vehicles stationed at the facilities at the time of the ordered evacuation could be loaded in as little as 15 minutes following notification. Accordingly, 50 percent of school buses depart onto the evacuation network during the period between 15 and 75 minutes, 90 percent by 135 minutes, and 99 percent by 165 minutes. The school profile was also applied for daycare facilities.
Evacuation of nursing home facilities would also require additional time associated with preparation and transport of vehicles to the respective facilities. Based on previous studies, it was assumed that these facilities would begin to evacuate between 30 minutes and 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> following notification. The first 50 percent will depart within 90 minutes, 90 percent within 150 minutes, and 99 percent within 180 minutes.
browns ferry - ete -ver9docx 5-5
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Departure Times - Browns Ferry EPZ 1
L0.8 0
0.6
" 0.4 E
S0.2 0
-resident day resident night
. worker
-schools special
-transit depend 0
50 100 150 Time (minutes) 200 Figure 5-1 Departure Time Distributions for the Browns Ferry EPZ 5.5 Evacuation Simulation Traffic simulation provides the ability to analyze evacuation of an area in great detail. In most traffic simulation models, there are two main inputs: supply (roadway) network data and demand (population and vehicular) data. Traffic models use different types of algorithms to predict traffic flow and provide measures of effectiveness (MOEs), such as average travel times, total number of vehicles exiting the system, and queue lengths at various times and points.
5.5.1 General Structure ARCADIS used PTV Vision to perform evacuation modeling for different scenarios.
The PTV Vision traffic simulation software package includes VISSIM (microscopic traffic simulation) and VISUM (macroscopic traffic simulation). VISUM is a comprehensive, flexible software system for transportation planning, travel demand modeling, and network data management. VISSIM is capable of performing detailed microscopic simulation of traffic, public transport, and pedestrian simulations, and can model any type of traffic control and geometric configuration. Both VISUM and VISSIM are capable of performing multimodal analysis, including car, commercial vehicle, bus, browns ferry - ete -veg.doo5 5-6
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates train, motorcycles, bicycles, and pedestrians. The two programs work together seamlessly, saving valuable time and resources.
GIS (WcGIS, NAVTEQ)
-Verified Evacuation
-Travel "T'imes Network
-Queue Lengths
- O-D Matrices eBotetlenecks
-Traffic Demand Volumes Figure 5-2 Evacuation Modeling and Simulation Using PTV Vision Suite VISUM was used to develop the evacuation network and population entry nodes (centroids). One of the key features of VISUM is its ability to interact seamlessly with GIS data, such as the ESRI ArcGIS database. The field-verified evacuation network data and demand data developed in ArcGIS were imported directly into VISUM. Origin-Destination trip tables were developed for the evacuation and imported into VISUM.
VISUM software was then used to route the origin-destination information on the network using a dynamic equilibrium algorithm. This algorithm ensured that traffic levels on the network were realistic given the capacities available on individual links.
Once an initial solution was found in VISUM, the information was exported into VISSIM for microsimulation. A microsimulation was deemed a necessary step in order to obtain detailed and realistic results on queuing and average travel times. VISSIM can model an intersection with different types of traffic control, such as yield signs, stop signs, and signals. VISSIM also provides a better understating of critical and congested parts of the network.
5.5.2 Simulation Process The ETE results include the time to evacuate 90 percent and 100 percent of the total permanent and transient population. Based on the current guidance, ETEs for special facilities, schools, and the transit-dependent population are developed separately; only time to evacuate 100 percent of these population groups was needed.
browns fen" -ere - ver9Ad(C 5-7
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Consistent with current guidance, vehicle demand for each scenario was based on 100 percent of the population residing in areas designated for evacuation, plus 20 percent of the population residing in ERPAs outside the designated evacuation area, and 20 percent of the population residing outside of the EPZ, out to a distance of 15 miles. Vehicle demand outside of the designated evacuation area is intended to account for the impact of "shadow evacuees." A sensitivity analysis was performed to evaluate the impact of different input parameters and assumptions, such as changes in lane closures, vehicular demand, and evacuation routes.
The simulation process can be summarized as follows:
VISUM
- 1. Create every scenario based on:
- a.
Background traffic
- b.
Time of day
- c.
Day of week
- d.
Weather condition
- e. Season
- f.
Wind direction
- g.
Shadow traffic
- 2.
Run Dynamic Traffic Assignment to calculate permanent and transient, shadow, special need/school volumes.
- 3. Assignment process will last until suitable convergence is reached. VISUM provides output on the goodness of convergence after assignment. The convergence fit is not as critical because this is an evacuation model of a no-notice event; therefore, full user equilibrium cannot be expected.
- 4.
ExporttoVISSIM.
brows feny - ete - -er9.doc-5-8
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates VISSIM
- 1. Warm-up time built into background/pass-through traffic generation.
- 2.
Check for any local calibration parameters.
- 3.
Run the final multimodal Dynamic Traffic Assignment in VISSIM to consider queues and intersection delays.
- 4.
Sensitivity analysis and count evacuees at 2, 5, and 10 miles.
- 5. Prepare ETE times.
MOEs
- 1. 90 percent evacuation time (for all wind directions and scenarios, staged and normal evacuations).
- a. This applies to evacuation of the public only.
- 2.
100 percent evacuation time (for all wind directions and scenarios, stage, and normal evacuations).
- 3.
Color-coded roadway map at various times (2, 4, 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />), which identifies where long queues exist, including LOS E and F conditions.
brows fern/ - ete - ver.doc 5-9
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 6. Analysis of Evacuation Times 6.1 Evacuation Time Estimate Summary Preliminary ETEs for the general population in the Browns Ferry EPZ are summarized by scenario and distance in Table 6-1 (times for 90 percent and 100 percent of vehicles to depart, for 2-mile zones, all zones to 5 miles, and all zones to 10 miles).
The pattern of evacuation times is consistent with the differences in vehicle demand and travel time for different scenarios.
The 2-mile zone involves the shortest travel distance and the fewest vehicles; 90 percent ETEs for the 2-mile zone range from 1:30 to 1:50, and 100% ETEs are 2:55 to 3:30. For all zones out to 5 miles, the 90% ETEs are 1:50 to 2:30, and the 100% ETEs are 3:25 to 4:05. For the full EPZ, the 90% ETEs are 2:40 to 3:50, while the 100%
ETEs are 3:50 to 6:50. All of these times are indicative of moderate delays related to traffic congestion.
During normal weather conditions, the final 10 percent of vehicles clear the 2-mile and 5-mile zones approximately 90 minutes after the initial 90 percent clear. When the full EPZ evacuates, the last 10 percent will take approximately 130 minutes longer to evacuate. This difference is due to two major centers of population located in between the 5-and 10-mile zones: Decatur and Athens. Adverse weather adds up to 70 minutes for the summer weekday ETEs, and up to 90 minutes for the winter weekday ETEs.
6.2 Comparison with Previous Study Population differences between the current ETE study and the 2008 study resulted in a slightly decreased vehicle demand for the full EPZ. A drop in transient residents was noted between the studies (18,532 vs. 22,586). The previous study used Synergos to estimate a "generic" transient population and vehicle demand. The current study uses facility-specific estimates, supplemented by data from LEHD. In addition, the current study makes adjustments to minimize double counting.
The new 100% ETE time is 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 10 minutes compared to the 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> estimated in the 2008 study. This difference can be attributed to both the difference in transient population and departure time differences. The previous report assumed up to 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> 30 minutes for workers which is almost 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> longer than the departure curve used in the current study (Figure 5-1). In addition, the simulation procedure of the previous browns ferry - eta -ver9.doc6 6-1
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates study called for modeling stop-controlled intersections instead of signalized which may have lead to longer delays and an extended ETE. The longer ETE could also be attributed to the previous model's strict adherence to evacuation routes. Although the official evacuation routes were generally the most heavily traveled, the current study model contained a much broader roadway network and, therefore, more routes were made available to evacuees.
6.3 Keyhole Evacuation Scenarios ETEs for scenarios that reflect the current range of Protective Action Response (PAR) scenarios to evacuate the near-field population and selected downwind zones are summarized in Table 6-2 for 5-mile PAR scenarios and Table 6-3 for 10-mile PAR scenarios. All of the 5-mile zone and 10-mile downwind PAR scenarios have varied ETEs in a range of 10 to 30 minutes. In general, the results reflect the strong influence of zones with larger populations, such as ERPAs A-1 0, B-1 0, D-10, and E-1 0.
However, in some cases, longer ETEs are the result of longer travel times to the ETE boundary. The scenario for wind direction W, for example, shows a similar evacuation time as the more heavily populated WNW and NW scenarios, but it is because residents in ERPA B-10 must travel a greater distance on U.S. 31 before exiting the EPZ in Athens. The WNW wind direction keyhole scenario for winter daytime has the longest ETE of any keyhole scenario. This is due to a bottleneck effect of traffic converging in the Decatur area.
6.4 Staged Evacuation Scenarios A series of staged evacuation scenarios were evaluated based on NRC guidance (CR-7002). In a staged evacuation, the 2-mile zone evacuates first, while surrounding zones shelter in place; after the population has evacuated the 2-mile zone, the outer zones would be instructed to evacuate. The "Stage 1" time is determined by simulating evacuation of the 2-mile zone for the Winter Weekday, Normal Weather scenario, with only background and shadow traffic in other parts of the EPZ. Once the Stage 1 time (1:30) was determined, a revised set of departure curves was developed for the outer (Stage 2) zones. The Stage 2 departure curves for Browns Ferry are shown on Figure 6-1. The departure curves are much steeper at the beginning of Stage 2 to account for the preparation time of evacuees sheltering in place during Stage 1. It was assumed that these evacuees will be ready to go at the beginning of Stage 2.
browns ferry - ete -ver9.docx 6-2
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Results for staged evacuation scenarios are summarized in Table 6-4. All of the staged keyhole scenarios have the same ETEs (within 5 minutes), independent of wind direction. These results are most likely due to the large population in the 2-mile zone and smaller populations in the 2-to 5-mile zones. Therefore, the clearance of the 2-mile zone effectively controls the overall ETE. The ETEs for the staged scenarios are greater than the ETEs for the "unstaged" scenarios. This accounts for the fact that the outer 2-to 5-mile zones take slightly longer to clear under a staged evacuation due to their delayed start time.
Stage 2 Departure Times - Browns Ferry EPZ 1
0.8 resident day
. 0.6
-resident night U-worker
> 0.4
-schools S-special 3 0.2 E
transit depend 0
0 0
50 100 150 200 Time (minutes)
Figure 6-1 Stage 2 Departure Time Distributions for the Browns Ferry EPZ brows ferry - ete -ver.docx3 6-3
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 6-1 Evacuation Time Estimate Summary for Browns Ferry EPZ Summer Winter Midwqeek Daytime Weeken vnng Mdek atm Weekien Evig Weahe:DaytimeDyt~i Daytime Eei~
Affected ERPAs cenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal 90 Percent Evacuation of Affected Areas (hours:minutes)
A-2, B-2, F-2, G-2 2-mile zone 1:30 1:40 1:50 1:40 1:30 1:45 1:50 1:40 A-2, B-2, B-5, E-5, F-2, F-5, G-2, 5-mile zone 2:05 2:15 1:55 1:55 2:05 2:30 1:50 1:50 G-5 ALL 10-mile EPZ 3:05 3:25 2:40 2:50 3:15 3:50 2:35 2:45 100 Percent Evacuation of Affected Areas (hours:minutes)
A-2, B-2, F-2, G-2 2-mile zone 2:55 3:25 3:10 3:10 2:55 3:30 3:10 3:10 A-2, B-2, B-5, E-5, F-2, F-5, G-2, 5-mile zone 3:25 4:00 3:25 3:25 3:25 4:05 3:10 3:10 G-5 ALL 10-mile EPZ 5:10 6:20 4:25 5:00 5:20 6:50 3:50 4:40 br s ferry - ete - ve-9 doc6 6-4
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 6-2 Evacuation Time Estimates for Partial EPZ Scenarios (2-Mile Zone Plus 5-Mile Downwind, Unstaged)
Summer Winter Daytime Daytime Affected ERPAs Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Weather:, Normal Adverse Normal Normal Normal Adverse Normal Normal 90 Percent Evacuation of Affected Areas (hours:minutes)
A-2,B-2,E-5,F-2,F-5,G-2 NNW-N 1:55 2:05 1:40 1:40 1:50 2:15 1:40 1:40 A-2,B-2,F-2,F-5,G-2,G-5 NNE-ENE 1:55 2:05 1:40 1:40 1:50 2:15 1:40 1:40 A-2,B-2,F-2,G-2,G-5 E-ESE 1:55 2:05 1:40 1:40 1:50 2:15 1:40 1:40 A-2,A-5,B-2,F-2,G-2,G-5 SE 2:05 2:15 1:55 1:55 2:00 2:25 1:50 1:50 A-2,A-5,B-2,F-2,G-2 SSE-S 2:05 2:15 1:55 1:55 2:00 2:25 1:50 1:50 A-2,A-5,B-2,B-5,F-2,G-2 SSW-WSW 2:05 2:15 1:55 1:55 2:00 2:25 1:50 1:50 A-2,B-2,B-5,F-2,G-2 W
2:05 2:15 1:55 1:55 2:00 2:25 1:50 1:50 A-2,B-2,B-5,E-5,F-2,G-2 WNW-NW 1:55 2:05 1:40 1:40 1:50 2:15 1:40 1:40 100 Percent Evacuation of Affected Areas (hours:minutes)
A-2,B-2,E-5,F-2,F-5,G-2 NNW-N 3:15 3:50 3:10 3:05 3:15 3:55 3:00 3:00 A-2,B-2,F-2,F-5,G-2,G-5 NNE-ENE 3:15 3:50 3:10 3:05 3:15 3:55 3:00 3:00 A-2,B-2,F-2,G-2,G-5 E-ESE 3:15 3:50 3:10 3:05 3:15 3:55 3:00 3:00 A-2,A-5,1B-2,F-2,G-2,G-5 SE 3:25 4:00 3:25 3:15 3:25 4:05 3:10 3:10 A-2,A-5,B-2,F-2,G-2 SSE-S 3:25 4:00 3:25 3:15 3:25 4:05 3:10 3:10 A-2,A-5,1B-2,B-5,F-2,G-2 SSW-WSW 3:25 4:00 3:25 3:15 3:25 4:05 3:10 3:10 A-2,B-2,B-5,F-2,G-2 W
3:25 4:00 3:25 3:15 3:25 4:05 3:10 3:10 A-2,B-2,B-5,E-5,F-2,G-2 WNW-NW 3:15 3:50 3:15 3:05 3:15 3:55 3:00 3:00 browns ferry - ate - ver9.dou5 6-5
0 ARCADIS Table 6-3 Evacuation Time Estimates for Partial EPZ Scenarios (5-Mile Zone Plus 10-Mile Downwind, Unstaged)
Browns Ferry Nuclear Power Plant Evacuation Time Estimates Summer Winter Miwee~k Daytime Weekend Eveuin.g Midweek Daytime Weekend Evening
____Daytime D__ aytime Affected ERPAs Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal 90 Percent Evacuation of Affected Areas (hours:minutes)
A-2,A-5,B-2,B-5,C-1 0,D-10,E-5,E-10,F-2,F-5,F-NNW-N 2:55 3:15 2:35 2:50 3:00 3:35 2:25 2:30 10,G-2,G-5 A-2,A-5,B-2,B-5,E-5,E-10,F-2,F-5,F-10,G-2,G-NNE 3:00 3:20 2:40 2:55 2:50 3:25 2:15 2:20 5,G-10 A-2,A-5,B-2,B-5,E-5,F-2,F-NE-ENE 2:45 3:05 2:30 2:40 2:40 3:15 2:00 2:10 5,F-10,G-2,G-5,G-10,H-10 A-2,A-5,B-2,B-5,E-5,F-2,F-E 2:45 3:05 2:30 2:40 2:40 3:15 2:00 2:10 5,G-2,G-5,G-10,H-10 A-2,A-5,B-2,B-5,E-5,F-2,F-5,G-2,G-5,H-10,1-10,J-ESE-SE 2:55 3:15 2:35 2:50 3:00 3:35 2:25 2:30 10,K-10 A-2,A-5,A-1 0,B-2,B-5,E-5,F-2,F-5,G-2,G-5,1-10,J-SSE 2:55 3:15 2:35 2:50 3:00 3:35 2:25 2:30 10,K-10 A-2,A-5,A-10,B-2,B-5,E-S 2:55 3:15 2:35 2:50 3:00 3:35 2:25 2:30 5,F-2,F-5,G-2,G-5,K-1 0 A-2,A-5,A-1 0,B-2,B-5,B-10,E-5,F-2,F-5,G-2,G-5,K-SSW 2:55 3:15 2:35 2:50 3:00 3:35 2:25 2:30 10 A-2,A-4,A-10,B-2,B-5,B-SW-WSW 2:40 3:00 2:20 2:35 2:40 3:15 2:05 2:10 10,E-5,F-2,F-5,G-2,G-5 A-2,A-5,B-2,-5,B-10,E-W 2:40 3:00 2:20 2:35 2:55 3:30 2:20 2:25 5,F-2,F-5,G-2,G-5 browrs ferry - ete - verg.docx 6-6
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Summer Winter Midweek Daytime Wekn vnn iwe atm Weeken Evening
___Daytime_
Daytime Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Affected ERPAs Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal A-2,A-5,B-2,B-5,B-1 0,C-10,D-10,E-5,F-2,F-5,G-WNW 3:05 3:25 2:50 3:00 3:15 3:50 2:35 2:45 2,G-5 A-2,A-5,B-2,B-5,B-1 0,C-10,D-10,E-5,E-10,F-2,F-NW 3:00 3:20 2:40 2:55 3:05 3:40 2:30 2:35 5,G-2,G-5 I
II 100 Percent Evacuation of Affected Areas (hours:minutes)
A-2,A-5,B-2,B-5,C-10,D-10,E-5,E-10,F-2,F-5,F-NNW-N 4:00 5:10 3:15 3:50 4:35 6:05 3:05 3:55 10,G-2,G-5 A-2,A-5,B-2,B-5,E-5,E-10,F-2,F-5,F-10,G-2,G-NNE 4:10 5:20 3:30 4:00 3:50 5:20 2:25 3:50 5,G-10 A-2,A-5,B-2,B-5,E-5,F-2,F-NE-ENE 3:50 5:00 3:10 3:40 3:50 5:20 2:25 3:50 5,F-10,G-2,G-5,G-10,H-10 A-2,A-5,B-2,B-5,E-5,F-2,F-E 3:50 5:00 3:10 3:40 3:50 5:20 2:25 3:50 5,G-2,G-5,G-10,H-10 A-2,A-5,B-2,B-5,E-5,F-2,F-5,G-2,G-5,H-10,1-10,J-ESE-SE 4:00 5:10 3:15 3:50 4:35 6:05 3:05 4:35 10,K-10 A-2,A-5,A-10,B-2,B-5,E-5,F-2,F-5,G-2,G-5,1-10,J-SSE 4:00 5:10 3:15 3:50 4:35 6:05 3:05 4:35 10,K-10 A-2,A-5,A-10,B-2, B-5,E-S 4:00 5:10 3:15 3:50 4:35 6:05 3:05 4:35 5,F-2,F-5,G-2,G-5,K-10 browns fenry - ete -ver9.doc6 6-7
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Summer Winte Midwek aytme mekn veigMdee atm Weeknd Evein Daytime Daytim Affected ERPAs Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal A-2,A-5,A-1 0,B-2,B-5,B-10,E-5,F-2,F-5,G-2,G-5,K-SSW 4:00 5:10 3:15 3:50 4:35 6:05 3:05 4:35 10 A-2,A-4,A-10,B-2,B-5,B-SW-WSW 4:05 5:15 3:20 3:55 4:20 5:50 2:50 4:20 10,E-5,F-2,F-5,G-2,G-5 I
A-2,A-5,B-2,B-5,B-10,E-W 4:20 5:30 3:35 4:10 4:20 5:50 2:50 4:20 5,F-2,F-5,G-2,G-5 A-2,A-5,B-2,B-5,B-1 0,C-10,D-10,E-5,F-2,F-5,G-WNW 4:20 5:30 3:35 4:10 5:10 6:40 3:40 5:10 2,G-5 A-2,A-5,B-2,B-5,-1 0,C-10,D-10,E-5,E-10,F-2,F-NW 4:20 5:30 3:35 4:10 4:35 6:05 3:10 4:35 5,G-2,G-5 brown ferry - ete - ve,9.doc8 6-8
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 6-4 Evacuation Time Estimates for Staged EPZ Scenarios (2-mile Zone, then 5-miles downwind)
Summer Winter W..
Evening M.idk.Daytie Evng Affected ERPAs M w Daytime Daytfime 2-mile Zone Scenario:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(A-2, B-2, F-2, G-2) then:
Weather:
Normal Adverse Normal Normal Normal Adverse Normal Normal 90 Percent Evacuation of Affected Areas (hours:minutes)
E-5, F-5 NNW-N 2:25 2:35 2:15 2:15 2:25 2:50 2:15 2:15 F-5, G-5 NNE-ENE 2:25 2:35 2:15 2:15 2:25 2:50 2:15 2:15 G-5 E-ESE 2:25 2:35 2:15 2:15 2:25 2:50 2:15 2:15 A-5, G-5 SE 2:25 2:35 2:15 2:15 2:25 2:50 2:10 2:10 A-5 SSE-S 2:25 2:35 2:15 2:15 2:25 2:50 2:10 2:10 A-5, B-5 SSW-WSW 2:25 2:35 2:15 2:15 2:25 2:50 2:15 2:15 B-5 W
2:25 2:35 2:15 2:15 2:25 2:50 2:15 2:15 B-5, E-5 WNW-NW 2:25 2:35 2:10 2:10 2:25 2:50 2:15 2:15 100 Percent Evacuation of Affected Areas (hours:minutes)
E-5, F-5 NNW-N 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 F-5, G-5 NNE-ENE 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 G-5 E-ESE 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 A-5, G-5 SE 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 A-5 SSE-S 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 A-5, B-5 SSW-WSW 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 B-5 W
3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 B-5, E-5 WNW-NW 3:30 4:05 3:25 3:20 3:30 4:10 3:15 3:15 bro s ferry - ete -ver9 doc6 6-9
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates 6.5 Sensitivity to Population Growth and Roadway Impact 6.5.1 Population Growth NRC guidance (CR-7002) for updating ETE studies more frequently than the 10-year federal census includes criteria based on population growth. Specifically, if the residential population growth in the EPZ since the last ETE update is sufficient to cause an increase in the ETE by 25 percent or by 30 minutes, whichever is less, then a full ETE update study must be performed.
A sensitivity analysis was performed by determining the 90% ETEs for increases of 10, 15, and 20 percent of the EPZ residential population for the Winter Weekday, Normal Weather scenario. This scenario produced the longest ETE by season or time of day. The population was increased in the same manner in the surrounding region, out to 15 miles. With a 20 percent increase in residential population above the 2010 U.S. Census values, the 90 percent ETE for the full EPZ increased to 3:20, an increase of 5 minutes. Because the EPZ residential population for Browns Ferry changed by less than 4 percent between 2000 and 2010, it appears unlikely that an increase of 20 percent will occur before 2020.
The 100% ETEs increased more rapidly than the 90% ETEs, consistent with the general pattern of all ETE results. Results are illustrated on Figure 6-2. With a 20 percent increase in population, the 100% ETE for the full EPZ increased by 49 minutes, from 5:10 to 5:59. NRC guidance (CR-7002) indicates that emergency planning decisions should be based on the 90% ETEs. The recommended "update threshold" for the Browns Ferry EPZ, based on population growth, is 20 percent because this is considered a prudent threshold for an updated study.
br-s ferry - ete - ver9.doc6 6-10
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates BFN -Population Growth vs ETE (Full EPZ) 6:00 5:55 5:50 5:45 u, 5:40
'W 5:35 o 5:30 0
' 5:25 5:20 5:15 5:10 5:05 2*__
y = 0.1583x + 0.2114 R2 = 0.8534
+
10mile
-Upper
-Linear (l0mile) 0%
5%
10%
15%
Population Increase %
20%
Figure 6-2 ETE Population Growth Sensitivity Analysis 6.5.2 Roadway Impact NRC guidance (CR-7002) also requires analysis of a "roadway impact" scenario. For this scenario, a major evacuation route is removed or reduced in capacity.
Specifically, one of the five highest volume roadways is removed from service. This scenario is specified as Summer Weekday, Normal Weather for the full EPZ. For Browns Ferry, the five highest volume roadways for this scenario are listed below:
AL 67 SB - 4,852 vehicles AL 24 WB - 4,046 vehicles U.S. 72 WB - 3,596 vehicles U.S. 31 NB - 2,554 vehicles AL 24 EB - 2,288 vehicles brons ferry - ete -ver9.do6 6-11
0 ARCADIS The route with the highest volume of vehicles, AL 67 (Beltline Highway in Decatur) was selected for the roadway impact. The roadway impact was modeled by completely blocking the route to traffic. The road closure caused some re-routing of evacuees compared to the Summer Day scenario with no lane closure. The impact location is shown on Figure 6-3. With the lane closure in place, the ETEs increased from 2:55 (90%) and 4:40 (100%) to 3:43 (90%) and 5:26 (100%). The increased ETEs are due to evacuees taking alternate routes to avoid the road closure. Figure 6-3 compares the traffic flows by link before and after the road closure.
Browns Ferry Nuclear Power Plant Evacuation Time Estimates Before After Figure 6-3 Comparison of Traffic Flows Before and After Road Closure Scenario 6.6 Performance Metrics for Simulation Model The performance of VISSIM is assessed using standard metrics, consistent with the guidance provided in CR-7002. Table 6-5 provides a summary of simulation parameters for Winter Day Normal Weather scenario for the full EPZ. Figure 6-4 illustrates the number of vehicles on the network over the course of the simulation, while Figure 6-5 compares the rate of vehicles loading onto the network to the frequency of departures. The parameters in Table 6-5 include an average travel browns ferry - ete -ver9.do=
6-12
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates speed for evacuating vehicles of 18.6 miles per hour, which indicates that traffic is encountering significant congestion during much of the simulation. The average travel time of 4.13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> reflects travel to the designated reception centers, rather than the travel time to exit the EPZ.
Table 6-5 Summary of Network Performance (Full 10-Mile EPZ, Winter Weekday, Normal Weather)
All Vehicles Background/Shadw Evacuation Average Delay (s) 6142 2154 7640 Average Stop Delay (s) 2256 834 2790 Average # of Stops 743 245 930 Average Speed (mph) 20.7 31.9 18.6 Average Travel Time (hr) 3.49 1.91 4.13 Vehicle Hours Traveled 170,795 27,005 143,790 Vehicle Miles Traveled 3,532,304 862,771 2,669,533
- of Completed Trips 48,904 14,103 38,807 Average Speed for Major Evacuation Routes Speed Route (mph)
AL 67 SB 40.8 Danville Rd SB to AL 67 SB 38.9 AL 20 to US 31 SB 28.3 US 31 SB 26.7 US 31 NB 53.4 AL 2 EB to AL 251-US 31 NB 37.3 Lee Hwy (US 72) EB to 1-65 NB 53.5 Lee Hwy (US 72) WB 53.3 AL 24 WB 62.3 Moulton St (AL 24) EB 44.0 Co Rd 434 to 460 WB 30.0 browns ferry - ete - verg.docx 6-13
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Evacuation Vehicles by Hour Crossing EPZ Boundary Fair Weather, Winter Day, Full EPZ Scenario 18000 16000
- 14000 0
12000 10000 4)
> 8000 a 2-mile o00 5-mile S6000
- 0 *10-mile E= 4000 z
2000 0
1 2
3 4
5 6
Simulation Hour 10-mile: 90% ETE = 3:15, 100% = 5:10 Figure 6-4 Time Distribution of Vehicles on the Network (Full 10-mile EPZ, Winter Weekday, Normal Weather) b-
,W y - ete -ve,9.do:61 6-14
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates U r 0
35 30 25 20 15 10 5
0 0
Mobilization and Cumulative EPZ Evacuation 100%
90%
80%
70%
60%
50%
Evacuation 40%
-Mobilization 30%
20%
10%
0%
100 200 300 400 Time after Evacuation Order Issued (min)
Figure 6-5 Comparison of Vehicle Mobilization and Departure Rates (Total Vehicles 38,807) 6.7 ETE for Transit-Dependent, Special Facilities, and Schools The ETE for transit dependent members of the general public is estimated based on the assumption of a single set of bus runs. The run would begin 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the evacuation notice, allowing time for evacuees to prepare and to travel to designated pickup points. The time sequence would then proceed in the following steps:
45 minutes for the bus to traverse up to ten pickup points (5 miles @ 20 mph) and load passengers (3 minutes per stop) 14 minutes to travel out of the EPZ (up to 10 miles @ 45 mph). Total time 2:59.
For non-ambulatory residents, ambulances and WC vans would also mobilize within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. For a WC van with three pickups, loading would take 15 minutes per stop, broms ferny - ete -ver9.docx 6-15
ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates transit between stops could take up to 30 minutes (10 miles at 20 mph), and travel out of the EPZ another 14 minutes (10 miles @ 45 mph): total time 3:29. An ambulance making two pickups would take 15 to 30 minutes less time to evacuate.
Estimated evacuation times for special facilities, schools and daycares located in the EPZ are summarized in Tables 6-6 and 6-7. These times are shorter than the 100%
ETEs for the general population. Facility-specific estimates are based on a three-step time sequence: (1) mobilization, (2) loading, and (3) travel out of the EPZ. Mobilization and loading times are generally the largest components.
At nursing homes and assisted living facilities, ambulatory patients will require 15 minutes to load a bus or van. WC buses or vans and ambulances will require 30 minutes to load. Schools and daycares load faster, on the order of 15 to 30 minutes total time, since loading buses is a more routine activity for school children. In all cases, it is assumed that multiple vehicles with load simultaneously. Mobilization times range from 90 to 150 minutes to contact drivers, provide them with instructions and deploy them to assigned schools and special facilities. For travel time, average speeds were estimated for the anticipated evacuation route, based on the traffic simulation for the Winter Day scenario. The simplified stepwise methodology used to determine these estimates provides a typical evacuation time, rather than an upper bound 100% value.
brows ferry - ere -ver9.doc 6-16
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 6-6 ETE for Special Facilities, Browns Ferry EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather)
VehilesDist nce Outb und Travel Mobilization Lo
...... o EPZ Tra l
T.
o ET.
Facility Population TmTie Boundary Spee P
(min) ye(min)
(min)
(ml)
(mph)
Bouda) 8 WC Bus 90 90 185 Parkway Medical Center 200 3
Ambulance 90 90 1.5 40.8 5
185 10 Bus90-120 60 155-180 3
WCBus 0
45140 Decatur Health & Rehab 3
WC Bus 90 45 Center 75 1
Ambulance 90 30 2
40.8 5
125 4
Bus 90 30 125 6
WC Bus 90 90 185 Limestone Health Facility 260 3
Ambulance 90 90 3
37.3 5
185 13 Bus90-120 60 155-180 4
WC Bus 90 60 155 Decatur Gen West 139 2
Ambulance 90 60 2
40.8 5
155 Behavioral 7
Bus90-120 30 125-155 Country Cottage 85 5
Bus90-120 30 3.5 40.8 5
125-155 Presbyterian Towers 150 8
Bus90-120 30 1.5 40.8 5
125-155 Decatur Work Release Cente 150 8
Bus90-120 30 2.5 28.3 5
125-155 Center Morgan County System 35 Bus 90 15 28.3 5
110 of Services browns ferry - ete -vet9,domx 6-17
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Table 6-7 ETE for Schools and Daycares, Browns Ferry EPZ (Full 10-mile EPZ, Winter Weekday, Normal Weather)
Facility Population Athens Intermediate 300 40 Auto 120 155 30 3.5 53.5 5
Austin High 1543 700 Auto 120 30 3
40.8 5
155 Benjamin Davis Elementary 303 6/20 Bus/Auto 150 30 2
44 5
185 Birdie Thornton Center 74 10/13 Bus/Auto 90 30 3.5 53.5 5
125 Brookhill Elementary 270 5/25 Bus/Auto 90 30 2.5 53.5 5
125 Clements High 620 14/225 Bus/Auto 150 30 5.5 53.3 5
185 East Lawrence Elementary 530 8/52 Bus/Auto 150 30 1.5 30 5
185 East Lawrence Middle/High 1213 21/87 Bus/Auto 150 30 1.5 30 5
185 James L. Cowart Elementary 270 3/25 Bus/Auto 90 15 3
37.3 5
110 Julian Harris Elementary 488 12/25 Bus/Auto 150 30 3
40.8 5
185 Leon Sheffield Elementary 382 8/20 Bus/Auto 150 30 3
26.7 5
185 Limestone County Career/Tech Center 350 8/40 Bus/Auto 150 30 2.5 53.4 5
185 Tanner High 1010 16/170 Bus/Auto 150 30 6
53.4 5
185 West Morgan Elementary/Middle/High 1476 11/285 Bus/Auto 150 30 3
62.3 5
185 Woodmeade Elementary 303 7/20 Bus/Auto 150 30 2.5 40.8 5
185 Blue Springs Elementary 575 14/50 Bus/Auto 150 30 7.5 53.3 10 190 West Decatur Elementary 292 7/18 Bus/Auto 90 30 3.5 38.9 5
125 browns feny - ete - -er.doc6 6-18
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates Day Care Facilities Lindsay Lane Christian BusNan/
Academy 115 1/1/15 Auto 90 30 1
53.5 5
125 Boys and Girls Club of Athens 128 2/8 Van/Auto 90 30 3
37.3 5
125 Tanner Head Start 67 6
Auto 90 30 6
53.4 5
125 Central Park Baptist Child Care 118 1/23 Van/Auto 90 30 2
40.8 5
125 Decatur Baptist Child Care 180 3/24 Van/Auto 90 30 1.5 40.8 5
125 Friendship Learning Center 137 1/25 Van/Auto 90 30 4
37.3 5
125 Kids R Us 60 1/5 Van/Auto 90 30 3
44 5
125 La Petite Academy 125 2/20 Bus/Auto 90 30 2
40.8 5
125 Lil' People Day School 90 1/6 Van/Auto 90 30 4
62.3 5
125 Noah's Ark Child Care 95 1/15 Van/Auto 90 30 2
40.8 5
125 Wesley Stay and Play 80 1/12 Van/Auto 90 30 2
40.8 5
125 Boys and Girls Club of Tanner 82 1/4 Van/Auto 90 30 6
53.4 5
125 Sterrs Daycare Center 36 6
Auto 90 15 3
28.3 5
110 browns ferry - ete -ver9doc6x 6-19
Browns Ferry Nuclear ARCADIS Power Plant Evacuation Time Estimates 6.8 Special Event A special event was modeled for the AYCA Soccer Tournament held at the Jack Allen Complex in Decatur, Alabama. An additional 1,200 personal vehicles (3 persons per vehicle) and 30 buses were modeled. It was assumed that all the vehicles would park within walking distance of the soccer fields and that the departure rates would be similar to other transient visitors in the EPZ.
The special event is held in ERPA D-10 of the EPZ, which is the ERPA with the highest vehicle demand and controls the ETE. When the additional vehicles were added to the Full EPZ, Summer Day (normal weather) scenario, the ETEs increased from 3:05 (90%) and 5:10 (100%) to 3:06 (90%) and 5:45 (100%). The large (35-minute) increase in the 100% evacuation time was an expected outcome due to higher vehicle demand in a congested part of the network.
browns ferry - ete -ver9.dmcx 6-20
0 ARCADIS Browns Ferry Nuclear Power Plant Evacuation Time Estimates
- 7.
Traffic Control Recommendations 7.1 General Evacuation simulation results have been reviewed to assess access control locations, traffic management locations, and recommendations for the Browns Ferry EPZ.
Predicted queuing at high-volume intersections is summarized in Table 7-1. None of the intersections listed are located inside the EPZ. Significant queue lengths are predicted only at locations where traffic is approaching a reception center.
7.2 Evacuation Access Control Locations Access control measures were not specifically addressed in the conduct of this study. Background traffic within the EPZ was not found to be a significant contributor to traffic congestion during the early stages of evacuation.
7.3 Traffic Management Locations and Tactics to Facilitate Evacuation The traffic simulation results for Browns Ferry indicate that traffic flow will not encounter significant congestion inside the EPZ, but will encounter delay on primary evacuation routes outside of the EPZ, especially in the cities of Decatur and Athens.
The traffic flow maps provided in Appendix F and the data in Table 7-1 reveal locations where additional traffic management could be best deployed to achieve a reduction in ETEs.
Table 7-1 Predicted Queuing at Major Intersections (Full 10-Mile EPZ, Winter Weekday, Normal Weather)
Intersection Name CitylTown/Area Control Type Avg Queue Vlm Volm Belttine Rd (AL 67) at US 31 Decatur, AL Signalized 200 7,400 AL 67 at NB 1-65 ramp Priceville, AL Signalized
<20 5,554 Beltline Rd (AL 67) at Central Pkwy Decatur, AL Signalized 880 4,842 Danvill Rd at Vestavia Dr Decatur, AL Two-way stop 480 3,586 Lee Hwy (U.S. 72) at NB 1-65 ramp Athens, AL Signalized 220 3,352 U.S. 31 merge with 1-65 Athens, AL Yield
<20 3,270 1-65 NB off-ramp at AL 53 Ardmore, AL Two-way stop 840 3,170 N Jefferson St (AL 127) at Upper Fort Hampton Rd Elkmont, AL Signalized 120 2,956 AL 53 at County Rd 71 Ardmore, AL Two-way stop 240 2,862 1-65 NB off-ramp at County Rd 100 Elkmont, AL Two-way stop
<20 2,828 7-1 browns ferr - ere -verd=.oc