Request for Additional Information Regarding License Amendment to Adopt TSTF-432-A, Rev 1, Change in Technical Specifications End States WCAP-16294
ML13207A410
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 08/13/2013
From: Pickett D
Plant Licensing Branch 1
To:
Entergy Nuclear Operations
Pickett D
References
TAC MF1898, TAC MF1899, TSTF-432-A, Rev 1, WCAP-16294
Download: ML13207A410 (3)


Text

\\.~p.~ REGU/ _

UNITED STATES

~v

~

°11 NUCLEAR REGULATORY COMMISSION

.~

WASHINGTON, D.C. 20555-0001

<t 0

Ii.

e

~

August 13, 2013

~

~

1-1}

~O

        • iI Vice President, Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249

SUBJECT:

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 - REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE AMENDMENT TO ADOPT TSTF-432-A, REV 1, "CHANGE IN TECHNICAL SPECIFICATIONS END STATES WCAP-16294" (TAC NOS. MF1898 AND MF1899)

Dear Sir or Madam:

By letter dated May 23,2013, Entergy Nuclear Operations, Inc., the licensee, submitted a license amendment request to adopt Technical SpeCification Task Force Change Traveler TSTF-432-A, Revision 1, "Change in Technical SpeCifications End States WCAP-16294," for Indian Point Nuclear Generating Unit Nos. 2 and 3.

The Nuclear Regulatory Commission's Technical Specification Branch is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). Based on our discussions we understand that a response to the RAI will be provided within 30 days of the date of this letter.

Please contact me at (301) 415-1364 if you have any questions on this issue.

Sincerely, Douglas V. Pickett, Senior Project Manager Plant licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286

Enclosure:

Request for Additional Information cc w/encl: Distribution via listserv

REQUEST FOR ADDITIONAL INFORMATION TECHNICAL SPECIFICATION BRANCH ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 DOCKET NOS. 50-247 AND 50-286 Indian Point Unit 2 (IP2) Technical Specification (TS) 3.5.3, "ECCS - Shutdown,"

requires two emergency core cooling system (ECCS) high head safety injection subsystems and one ECCS Residual Heat Removal (RHR) subsystem to be operable whereas Indian Point Unit 3 (IP3) TS 3.5.3, "ECCS - Shutdown," requires one ECCS RHR subsystem and one ECCS recirculation subsystem to be operable.

Request for Additional Information #1 Other than the ECCS injection points, IP2's Updated Final Safety Analysis Report (UFSAR) and IP3's UFSAR essentially read the same for the ECCS. Explain why the limiting conditions for operation are different between IP2 TS 3.5.3 and IP3 TS 3.5.3.

Request for Additional Information #2 Explain how the TR-WCAP-16294 quantitative risk evaluation for TS 3.5.3 applies to both IP2 and IP3.

Enclosure

August 13,2013 Vice President, Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249

SUBJECT:

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 - REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE AMENDMENT TO ADOPT TSTF-432-A, REV 1, "CHANGE IN TECHNICAL SPECIFICATIONS END STATES WCAP-16294" (TAC NOS. MF1898 AND MF1899)

Dear Sir or Madam:

By letter dated May 23,2013, Entergy Nuclear Operations, Inc., the licensee, submitted a license amendment request to adopt Technical Specification Task Force Change Traveler TSTF-432-A, Revision 1, "Change in Technical Specifications End States WCAP-16294," for Indian Point Nuclear Generating Unit Nos. 2 and 3.

The Nuclear Regulatory Commission's Technical Specification Branch is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). Based on our discussions we understand that a response to the RAI will be provided within 30 days of the date of this letter.

Please contact me at (301) 415-1364 if you have any questions on this issue.

Sincerely, Ira!

Douglas V. Pickett, Senior Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-247 and 50-286