ML13190A215
Jump to navigation
Jump to search
| ML13190A215 | |
| Person / Time | |
|---|---|
| Site: | Hope Creek |
| Issue date: | 07/02/2013 |
| From: | John Hughey Plant Licensing Branch 1 |
| To: | Duke P Public Service Enterprise Group |
| Hughey J | |
| Shared Package | |
| ml13190A204 | List: |
| References | |
| EA-12-051 | |
| Download: ML13190A215 (1) | |
Text
From:
Hughey, John To:
"Duke, Paul R."
Subject:
RAIs for Hope Creek Regarding Response to Order EA-12-051 (SFP Instrumentation)
Date:
Tuesday, July 02, 2013 4:26:00 PM Attachments:
Draft RAI.doc
- Paul, By letter dated February 27, 2013 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML13071A579 and ML13071A580), PSEG Nuclear, LLC submitted an Overall Integrated Plan (OIP) in response to the March 12, 2012, U.S. Nuclear Regulatory Commission (NRC), Commission Order modifying licenses with regard to requirements for Reliable Spent Fuel Pool (SFP) Instrumentation (Order Number EA-12-051; ADAMS Accession No. ML12054A679) for Hope Creek Generating Station.
The NRC staff has reviewed the February 27, 2013, response and determined that the attached Draft Request for Additional Information (RAI) is needed to complete its Technical Review. If any part of this information is not available by August 5, 2013, please provide the date this information will be submitted. Please contact me by Monday, July 8, 2013, If you would like to hold a teleconference to discuss these draft questions, before they are formally transmitted to you.
- Thanks, John John Hughey Salem / Hope Creek Project Manager NRR / Division of Operating Reactor Licensing Phone: 301-415-3204 e-mail: John.Hughey@nrc.gov