ML13172A290
| ML13172A290 | |
| Person / Time | |
|---|---|
| Site: | SHINE Medical Technologies |
| Issue date: | 05/31/2013 |
| From: | Bynum R Shine Medical Technologies |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| J Costedio | |
| References | |
| SHINE, SHINE.SUBMISSION.2, SHN.PSAR.P, SHN.PSAR.P.0 | |
| Download: ML13172A290 (17) | |
Text
REFERENCE 1.) AEROMAGNETIC ANOMALY MAP AND LEGEND FROM MAUS ET AL. (2009).
0 APPROXIMATE SCALE MILES 62 62 LEGEND LEGEND SHINE SITE 200 MILE (322 KM) RADIUS 0
APPROXIMATE SCALE KM 100 100 92° 0' 0" W 88° 0' 0" W 92° 0' 0" W 88° 0' 0" W 40° 0' 0" N 44° 0' 0" N 40° 0' 0" N 44° 0' 0" N Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Magnetic Anomaly Map of Wisconsin and Northern Illinois MAUS ET AL., 2009.
WABASH VALLEY LIQUEFACTION FEATURES REELFOOT SCARP AND NEW MADRID SEISMIC ZONE
-125
-100
-50 0
50 75 MILLIGALS REFERENCE 1.)
2.)
LEGEND LEGEND SHINE SITE SCALE 0
KM 300 300 200 MILE (322 KM) RADIUS SCALE 0
MILES 186 186 100° 0' 0" W 95° 0' 0" W 90° 0' 0" W 85° 0' 0" W 100° 0' 0" W 95° 0' 0" W 90° 0' 0" W 85° 0' 0" W 80° 0' 0" W 35° 0' 0" N 40° 0' 0" N 45° 0' 0" N 35° 0' 0" N 40° 0' 0" N 45° 0' 0" N Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Regional Bouguer Gravity Anomaly Map
WABASH VALLEY LIQUEFACTION FEATURES
-125
-100
-50 0
50 75 MILLIGALS REFERENCE 1.)
LEGEND LEGEND SHINE SITE SCALE 0
KM 100 100 200 MILE (322 KM) RADIUS SCALE 0
MILES 62 62 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Bouguer Gravity Anomaly Map of Wisconsin and Northern Illinois
SURFICIAL GEOLOGIC UNIT CLAY AND SILT, GLACIAL AND POST GLACIAL LAKE DEPOSITS - HOLOCENE AND LATE WISCONSIN AGE GLACIOFLUVIAL OUTWASH DEPOSITS - LATE WISCONSIN AND HOLOCENE (?)
CHANNEL AND FLOOD PLAIN ALLUVIUM OF HOLOCENE AND LATE WISCONSIN AGE END-MORAINE DEPOSITS, CLAYEY TILL - LATE WISCONSIN AND HOLOCENE (?)
GROUND-MORAINE DEPOSITS, LOAMY TILL - LATE WISCONSIN AND HOLOCENE (?)
GROUND-MORAINE DEPOSITS, CLAYEY TILL - LATE WISCONSIN AND HOLOCENE(?)
END-MORAINE DEPOSITS, LOAMY TILL - LATE WISCONSIN AND HOLOCENE (?)
CLAYEY TO LOAMY TILL - ILLINOIAN GROUND-MORAINE DEPOSITS, LOAMY TILL - ILLINOIAN LOAMY TILL - PRE-ILLINOIAN COLLUVIUM AND SHEETWASH ALLUVIUM - QUATERNARY AGE AGE SILT (LOESS) - HOLOCENE AND LATE WISCONSIN REFER TO REFERENCE FOR UNIT DESIGNATION LIMIT OF GLACIAL ADVANCE - DASHED WHERE INFERRED HATCHURES POINT IN DIRECTION OF GLACIATED AREA REFERENCE 1.) MAP AND LEGEND FROM FULLERTON ET AL. (2003).
SCALE 0
125 125 KM LEGEND LEGEND SHINE SITE 200 MILE (322 KM) RADIUS CONTACT LATE WISCONSIN ILLINOIAN PRE-ILLINOIAN SCALE 0
78 78 MILES LAKE MICHIGAN LAKES 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Regional Surficial Geology Map 1.) FULLERTON ET AL., 2003.
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Unconsolidated and Drift Thicknesses Map for Wisconsin and Northern Illinois
Chicago Milwaukee Madison KANKAKEE ARCH SANDWICH FAULT ZONE LA SALLE ANTICLINORIUM PLUM RIVER FAULT ZONE WISCONSIN ARCH WISCONSIN DOME MICHIGAN BASIN ILLINOIS BASIN MEEKERS GROVE ANTICLINE MADISON FAULT JANESVILLE FAULT MINERAL POINT ANTICLINE ZONE OF COOK COUNTY FAULTS GALENA SYNCLINE UNNAMED FAULT IN ROCK COUNTY MISSISSIPPI RIVER ARCH HOUSTON COUNTY FAULTS IOWA CITY-CLINTON FAULT ZONE ST. CHARLES LINEAMENT PEORIA FOLDS SOUTHEAST IOWA FOLDS EAU PLEINE SHEAR ZONE MOWER COUNTY FAULTS WABASHA AND GOODVUE COUNTY FAULTS WABASH VALLEY LIQUEFACTION FEATURES AMANA FAULT WAUKESHA FAULT ROYAL CENTER FAULT MAGNITUDE SCALE 0
KM 70 70 LEGEND LEGEND SHINE SITE EPICENTER WITH FELT INTENSITY AT JANESVILLE (MMI)
REFERENCE 1.) EARTHQUAKE LOCATIONS: CEUS-SSC, 2012 AND NEID, 2012.
2.) FAULT
REFERENCE:
GARRITY, C.P., AND SOLLER, D.R., 2009.
200 MILE (322 KM) RADIUS SCALE 0
MILES 62 62 NO MMI VALUE MMI 5 MAY 26, 1909 EARTHQUAKE LAKE MICHIGAN 0 to 2.9 3 to 3.9 4 to 4.9 5 to 5.9 FAULT AND FOLD TREND 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 92° 0' 0" W 90° 0' 0" W 88° 0' 0" W 86° 0' 0" W 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N 40° 0' 0" N 42° 0' 0" N 44° 0' 0" N Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Historical Earthquake Epicenters
WEST 0
APPROXIMATE SCALE KM 400 400 REFERENCE 1.)
SHINE SITE NORTH LEGEND LEGEND 0
APPROXIMATE SCALE MILES 249 249 Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map December 16, 1811 Earthquake
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map September 01, 1886 Earthquake 0
APPROXIMATE SCALE KM 400 400 REFERENCE 1.) ISOSEISMAL MAP OF 09/01/1886 EARTHQUAKE FROM (STOVER, C.W. AND COFFMAN, J.L., 1993).
WEST SHINE SITE NORTH LEGEND LEGEND 0
APPROXIMATE SCALE MILES 249 249
REFERENCE 1.)
.
WEST SHINE SITE NORTH LEGEND LEGEND NUMBERS ARE MMI ASSIGNMENTS:
F - DENOTES THAT THE EVENT WAS FELT, BUT THAT THE INFORMATION IS NOT SUFFICIENT TO ASSIGN AN MMI.
O - DENOTES THAT THE EVENT WAS REPORTED AS NOT FELT.
N - DENOTES THAT THE EVENT WAS NOT MENTIONED AND IS PRESUMED "NOT FELT".
THE THICK BLACK ISOSEISMAL LINES ENCLOSE ISOSEISMAL AREAS.
THE EASTERN RED STAR IS STOVER AND COFFMAN'S (1993) EPICENTER LOCATION.
THE WESTERN RED STAR IS BAKUN AND HOPPER'S (2004) PREFERRED EPICENTER LOCATION.
0 APPROXIMATE SCALE KM 266 266 0
APPROXIMATE SCALE MILES 165 165 Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map September 27, 1891 Earthquake
0 APPROXIMATE SCALE KM 340 340 REFERENCE 1.) ISOSEISMAL MAP OF 10/31/1895 EARTHQUAKE FROM STOVER AND COFFMAN (1993).
WEST SHINE SITE NORTH LEGEND LEGEND 0
APPROXIMATE SCALE MILES 211 211 Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map October 31, 1895 Earthquake 1.) STOVER, C.W. AND COFFMAN, J.L., 1993.
REFERENCE 1.)
WEST SHINE SITE NORTH LEGEND LEGEND NUMBERS ARE MMI ASSIGNMENTS:
F - DENOTES THAT THE EVENT WAS FELT, BUT THAT THE INFORMATION IS NOT SUFFICIENT TO ASSIGN AN MMI.
O - DENOTES THAT THE EVENT WAS REPORTED AS NOT FELT.
N - DENOTES THAT THE EVENT WAS NOT MENTIONED AND IS PRESUMED "NOT FELT".
THE THICK BLACK ISOSEISMAL LINES ENCLOSE ISOSEISMAL AREAS.
THE EASTERN RED STAR IS STOVER AND COFFMAN'S (1993) EPICENTER LOCATION.
THE WESTERN RED STAR IS BAKUN AND HOPPER'S (2004) PREFERRED EPICENTER LOCATION.
0 APPROXIMATE SCALE KM 217 217 0
APPROXIMATE SCALE MILES 135 135 Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map May 26, 1909 Earthquake BAKUN, W.H. AND HOPPER, M.G., 2004.
SHINE SITE NORTH APPROXIMATE
0 APPROXIMATE SCALE KM 310 310 REFERENCE 1.)
0 APPROXIMATE SCALE MILES 193 193 WEST SHINE SITE NORTH LEGEND LEGEND Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Isoseismal Map November 09, 1968 Earthquake
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Deaggregation of USGS 2008 PSHA Model for 475-Year Return Period PGA
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Deaggregation of USGS 2008 PSHA Model for 2,475-Year Return Period PGA
REFERENCE NOTE 1.) CALCULATION FOR SHINE SITE (42.624°N, 89.025°W) FROM THE 2008 USGS NATIONAL PSHA (V = 760 m/s, SITE CLASS BC).
s 30 1.)
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Deaggregation of USGS 2008 PSHA Model for 4,975-Year Return Period PGA
REFERENCE NOTE 1.) CALCULATION FOR SHINE SITE (42.624°N, 89.025°W) FROM THE 2008 USGS NATIONAL PSHA (V = 760 m/s, SITE CLASS BC).
s 30 1.)
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Deaggregation of USGS 2008 PSHA Model for 9,950-Year Return Period PGA
REFERENCE NOTE 1.) CALCULATION FOR SHINE SITE (42.624°N, 89.025°W) FROM THE 2008 USGS NATIONAL PSHA (V = 760 m/s, SITE CLASS BC).
s 30 1.)
Chapter 2 - Site Characteristics Geology, Seismology, and Geotechnical Engineering SHINE Medical Technologies Rev. 0 Figure 2.5 Deaggregation of USGS 2008 PSHA Model for 19,900-Year Return Period PGA