ML13057A171

From kanterella
Jump to navigation Jump to search
2013 Monticello Nuclear Generating Plant Initial License Examination Form ES-401-4
ML13057A171
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 01/29/2013
From: Mcneil D
NRC/RGN-III/DRS/OLB
To:
References
Download: ML13057A171 (3)


Text

ES-401 Record of Rejected K/As Form ES-401-4 Tier /

Group Randomly Selected K/A Reason for Rejection RO PORTION 1/1 295005 AK3.02 Not applicable to MNGP. A recirculation pump trip does not occur when a main turbine trip occurs. Reselected AK3.08 which was also rejected because it only applies to a BWR-2 unit. Reselected AK3.07.

1/1 295021 2.2.4 Not applicable to MNGP. Dual unit K/A only. Reselected 2.2.36.

1/1 295028 EA2.06 MNPG do not have a means of monitoring Torus air space temperature. Rejected EA2.06 and reselected EA2.03.

1/1 295006 AA1.03 Rejected to prevent double jeopardy with RO question #4 (295005 AK3.07). Reselected AA1.02.

1/2 295034 EK3.01 Rejected the 295034 E/APE due to double jeopardy with question 18 (295038 EK3.03) and question 24 (295033 EK2.04). Reselected 295020 AK3.05.

2/1 205000 K6.06 Not applicable to MNGP and low importance rating (<2.5).

Reselected K6.04.

2/1 211000 A3.05 MNGP does not have SLC flow indication in the control room.

Reselected A3.04.

2/1 212000 A4.03 MNGP does not have the ability for manual select rod insertion as it relates to RPS. Reselected A4.05 2/1 223002 K5 No K5 K/As exist for this topic. Reselected K6 for Tier/Group balance and reselected K6.04.

2/1 259002 A1.06 MNGP does not use FWCI. Reselected A1.01.

2/1 261000 A2.12 MNGP does not utilize fuel pool ventilation radiation monitors.

Reselected A2.04.

2/1 263000 2.2.39 There are no <1hour technical specification actions associated with the DC distribution system. Reselected 2.1.28.

2/1 215003 2.4.35 MNGP does not have local auxiliary operator tasks performed in an emergency associated with the IRM system. Reselected 2.2.38.

2/1 264000 K2 K2 K/As for this topic all have low importance rating (<2.5).

Reselected K5 for Tier/Group balance and reselected K5.06.

2/2 201003 K2 No K2 K/As exist for this topic. Reselected K1 for Tier/Group balance and reselected K1.02.

2/2 215001 K6.03 Low importance rating (<2.5). Reselected K6.04.

Tier /

Group Randomly Selected K/A Reason for Rejection 2/2 233000 A1.05 Low importance rating (<2.5). Reselected A1.07.

3 Generic 2.2.5 Low importance rating (<2.5). Reselected 2.2.2.

3 Generic 2.3.6 Low importance rating (<2.5). Reselected 2.3.15.

SRO PORTION 1/1 295021 AA2.05 Unable to write operationally valid SRO-ONLY question specific to reactor vessel metal temperatures as it relates to a loss of shutdown cooling. Reselected AA2.04.

1/1 295030 EA2.04 Rejected the 295030 topic as all EA2 K/As would result in an SRO ONLY question similar to the previous question in the 295026 topic. This could result in a potential double jeopardy or question compromise situation.

Reselected 600000 AA2.16.

1/2 295012 2.4.9 Rejected 2.4.9 due to the inability to write a question specific to low power

/ shutdown conditions as it applies to high drywell temperature. Reselected 2.1.25.

2/1 262002 A2.04 Not applicable to MNGP. BWR-1 only. Reselected A2.01.

2/2 201001 A2 Rejected the 201001 topic. Unable to write SRO ONLY question that is operationally valid and that contains all plausible distracters. Reselected 202001 A2.06