MONTHYEARLR-N12-0183, License Amendment Request: Revision to Technical Specification (TS) 3.7.6.1 (Unit 1) and 3.7.6 (Unit 2) Control Room Emergency Air Conditioning System2012-07-17017 July 2012 License Amendment Request: Revision to Technical Specification (TS) 3.7.6.1 (Unit 1) and 3.7.6 (Unit 2) Control Room Emergency Air Conditioning System Project stage: Request ML13003A0452013-01-0202 January 2013 E-mail RAI for Creacs LAR Project stage: RAI ML13003A0482013-01-0202 January 2013 E-mail Draft Request for Additional Information Project stage: Draft RAI ML13014A2682013-01-24024 January 2013 Request for Additional Information Deletion of Condition for Inoperable Caacs/Creacs Isolation Dampers Project stage: RAI LR-N13-0007, Response to Request for Additional Information Dated January 24, 2013, License Amendment Request: Revision to Technical Specification (TS) 3.7.6.1 (Unit 1) and 3.7.6 (Unit 2) Control Room Emergency Air Conditioning System2013-01-28028 January 2013 Response to Request for Additional Information Dated January 24, 2013, License Amendment Request: Revision to Technical Specification (TS) 3.7.6.1 (Unit 1) and 3.7.6 (Unit 2) Control Room Emergency Air Conditioning System Project stage: Response to RAI LR-N12-0410, Response to Request for Information Regarding Flooding Aspects of Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident - Integrated Assessment Approach2013-01-28028 January 2013 Response to Request for Information Regarding Flooding Aspects of Recommendation 2.1 of the Near Term Task Force Review of Insights from the Fukushima Dai-ichi Accident - Integrated Assessment Approach Project stage: Request ML13038A7132013-02-0707 February 2013 Draft RAI for Creacs LAR Project stage: Draft RAI ML13063A7172013-03-11011 March 2013 Second Request for Additional Information Deletion of Condition for Inoperable Control Area Air Condition System/Control Room Emergency Air Conditioning System Isolation Dampers Project stage: RAI LR-N13-0057, Response to Second Request for Additional Information Dated 03/11/2013, Deletion of Condition for Inoperable Control Area Air Conditioning System / Control Room Emergency Air Conditioning System Isolation Dampers2013-03-22022 March 2013 Response to Second Request for Additional Information Dated 03/11/2013, Deletion of Condition for Inoperable Control Area Air Conditioning System / Control Room Emergency Air Conditioning System Isolation Dampers Project stage: Request ML13171A0632013-07-17017 July 2013 Issuance of Amendments Revision to Technical Specification 3.7.6.1 (Unit 1) and 3.7.6 (Unit 2) Control Room Emergency Air Conditioning System Project stage: Approval 2013-01-28
[Table View] |
Similar Documents at Salem |
|---|
|
Text
DRAFT DRAFT REQUEST FOR ADDITIONAL INFORMATION REGARDING SALEM GENERATING STATION, UNIT 1 AND 2 DELETION OF CONDITION FOR INOPERABLE CAACS/CREACS ISOLATION DAMPERS DOCKET NUMBERS: 50-272 AND 50-311 (TAC NOS. ME9095 AND ME9096)
By letter dated July 17, 2012, PSEG submitted a license amendment request for Salem Generating Station Units 1 and 2 (ADAMS Accession No. ML12199A426), to revise Technical Specification (TS) 3/4.7.6.1 (Unit 1) and 3/4.7.6 (Unit 2), "Control Room Emergency Air Conditioning System," by removing the separate action for securing an inoperable Control Area Air Conditioning and Control Room Emergency Air Conditioning System isolation damper in the closed position and entering the actions for an inoperable control room envelope boundary. The NRC staff has reviewed the information submitted by the licensee, and based on this review, determined the following information is required to complete the evaluation.
RAI 1: Salem Unit 1 TS 6.18 and Unit 2 TS 6.17 contain the Control Room Envelope (CRE)
Habitability Program. Element a of the program requires a definition of the CRE and CRE boundary. The amendment request did not discuss the current definition of the CRE, whether or not the isolation dampers in question are defined as part of the CRE boundary, or whether or not the CRE was being redefined.
Please clarify whether or not the isolation dampers are currently defined as part of the CRE boundary.