ML13002A415
ML13002A415 | |
Person / Time | |
---|---|
Site: | Wolf Creek |
Issue date: | 10/31/2012 |
From: | KLD Engineering, PC |
To: | Office of Nuclear Reactor Regulation, Wolf Creek |
References | |
RA 12-0126 KLD TR-522, Rev 1 | |
Download: ML13002A415 (100) | |
Text
6 DEMAND ESTIMATION FOR EVACUATION SCENARIOS An evacuation "case" defines a combination of Evacuation Region and Evacuation Scenario.
The definitions of "Region" and "Scenario" are as follows:
Region A grouping of contiguous evacuating subzones that forms either a "keyhole" sector-based area, or a circular area within the EPZ, that must be evacuated in response to a radiological emergency.
Scenario A combination of circumstances, including time of day, day of week, season, and weather conditions. Scenarios define the number of people in each of the affected population groups and their respective mobilization time distributions.
A total of 63 Regions were defined which encompass all the groupings of subzones considered.
These Regions are defined in Table 6-1. The subzones configurations are identified in Figure 6-1. Each keyhole sector-based area consists of a central circle centered at the power plant, and three adjoining sectors, each with a central angle of 22.5 degrees, as per NUREG/CR-7002 guidance. The central sector coincides with the wind direction. These sectors extend to 5 miles from the plant (Regions R04 through R19) or to the EPZ boundary (Regions R20 through R46).
Regions R01, R02 and R03 represent evacuations of circular areas with radii of 2, 5 and 10 miles, respectively. Regions R47 through R63 are identical to Regions R02 and R04 through R19, respectively; however, those subzones between 2 miles and 5 miles are staged until 90% of the 2-mile region (Region R01) has evacuated.
A total of 14 Scenarios were evaluated for all Regions. Thus, there are a total of 63 x 14 = 882 evacuation cases. Table 6-2 is a description of all Scenarios.
Each combination of region and scenario implies a specific population to be evacuated. Table 6-3 presents the percentage of each population group estimated to evacuate for each scenario.
Table 6-4 presents the vehicle counts for each scenario for an evacuation of Region R03 - the entire EPZ.
The vehicle estimates presented in Section 3 are peak values. These peak values are adjusted depending on the scenario and region being considered, using scenario and region specific percentages; the scenario percentages are presented in Table 6-3, while the regional percentages are provided in Table H-1. The percentages presented in Table 6-3 were determined as follows:
The number of residents with commuters during the week (when workforce is at its peak) is equal to the product of 51% (the number of households with at least one commuter) and 44%
(the number of households with a commuter that would await the return of the commuter prior to evacuating). See assumption 3 in Section 2.3. It is estimated for weekend and evening scenarios that 10% of households with returning commuters will have a commuter at work during those times.
Wolf Creek Generating Station 6-1 KLD Engineering. P.C.
Evacuation Time Estimate Rev. 1
Employment is assumed to be at its peak during the winter, midweek, midday scenarios.
Employment is reduced slightly (96%) for summer, midweek, midday scenarios. This is based on the estimation that 50% of the employees commuting into the EPZ will be on vacation for a week during the approximate 12 weeks of summer. It is further estimated that those taking vacation will be uniformly dispersed throughout the summer with approximately 4% of employees vacationing each week. It is further estimated that only 10% of the employees are working in the evenings and during the weekends.
As shown in Appendix E, the only transients in the EPZ are at the two lodging facilities offering overnight accommodations in the EPZ; thus, transient activity is estimated to be high during weekend and evening hours - 75% for summer and 100% for winter. Transient activity is less during the week, during the day - 50% for summer and 90% for winter.
As noted in the shadow footnote to Table 6-3, the shadow percentages are computed using a base of 20% (see assumption 5 in Section 2.2); to include the employees within the shadow region who may choose to evacuate, the voluntary evacuation is multiplied by a scenario-specific proportion of employees to permanent residents in the shadow region. For example, using the values provided in Table 6-4 for Scenario 1, the shadow percentage is computed as follows:
( 414 =
20% x + 41422%
%1836+2,889 2 One special event - Wolf Creek Refueling Outage - was considered as Scenario 13. Thus, the special event traffic is 100% evacuated for Scenario 13, and 0% for all other scenarios.
It is estimated that summer school enrollment is approximately 10% of enrollment during the regular school year for summer, midweek, midday scenarios. School is not in session during weekends and evenings, thus no buses for school children are needed under those circumstances. As discussed in Section 7, schools are in session during the winter season, midweek, midday and 100% of buses will be needed under those circumstances. Transit buses for the transit-dependent population (those who do not own vehicles and those in correctional facilities) are set to 100% for all scenarios as it is assumed that the transit-dependent population is present in the EPZ for all scenarios.
External traffic is estimated to be reduced by 60% during evening scenarios and is 100% for all other scenarios.
Wolf Creek Generating Station 6-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. I
Table 6-1. Description of Evacuation Regions Region Radial Subzones
__ Evacuation -C,_2 1N - - - IS- - - - - R 2-Mile Evacuate Raisanio nwnno8 ie Wind Direction Subzones Region From N1 N2 N - E2 N - - - E2 S - E452S - -
(Degrees): N- E3 E1S- E4 I51IS2S - -- WI N -
R04 354-6 ...
ROS_ 7- 16 ...
R06 17- 27 ...
0R07 28 -67 ...
RO08-7 R094-9 RI 7 0 R15R 08 6-7283...
RR09 74965 RR11 17 -162...
R13__L 174-196.. ..
R439-6 RR15 208-248 R16 249-275 R17 276-281 R18 978--296 R19 2079-3118 WofCekWeeaind Dire tion 6-3KL Egieein, .C Revauaion Estmat Frome Ne-. E3 E1 E2SI2 S- E ý-1 5- WI S - - - R W1 N 1EN-
Radial Subzones Region I Evacuation I NE-i I NE-2 I NE-3 I E-i I E-2 I SE-i I SE-2 I SE-3 I SE-4 I S-i I S-2 I SW-X I SW-2 I W-i I -
R30 119-128 R31 129-162 I I I R32 163-173
+-+ ------4 4- 4 4 4 4 R33 174- 186 4- + 4 4- + 4 + 4 4 4-R34 187-196 R35 197-207 R36 208-225 R37 226-248
+ 4 4- 4-4 4 4 4 R38 249-253 R39 254-275 R40 276-281 R41 R42 R43 282-292 293-298 il -4 4 4 4- 4 299-315 R44 316-331 R45 332 -343 OAA -C Wind Direction Region From:
R47 5-Mile Ring R48 354-6 R49 7-16 R50 17-27 R51 28-67 R52 68-73 R53 74-96 R54 97-106 R55 107-162 R56 163-173 R57 174-196 R58 197-207 R59 208-248 R60 249-275 R61 276-281 R62 282-298 Subzone(s) Shelter-in-Place Wolf Creek Generating Station 6-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 6-1. WCGS EPZ Subzones Wolf Creek Generating Station 6-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
-0
Table 6-2. Evacuation Scenario Definitions 1 Summer Midweek Midday Good None 2 Summer Midweek Midday Rain None 3 Summer Weekend Midday Good None 4 Summer Weekend Midday Rain None 5 Summer Midweek, Evening Good None Weekend 6 Winter Midweek Midday Good None 7 Winter Midweek Midday Rain None 8 Winter Midweek Midday Snow None 9 Winter Weekend Midday Good None 10 Winter Weekend Midday Rain None 11 Winter Weekend Midday Snow None 12 Winter Midweek, Evening Good None Weekend Eeig Go Wolf Creek Refueling 13 Winter Midweek Midday Good o utage Outage Roadway Impact -
14 Summer Midweek Midday Good Closure of One Segment on US-75 Southbound 1 Winter means that school is in session (also applies to spring and autumn). Summer means that school is not in session.
KLD Engineering, P.C.
Wolf Creek Generating Station 6-6 6-6 KLD Engineering, P.C.
Evacuation Time Estimate Rev. I
Table 6-3. Percent of Population Groups Evacuating for Various Scenarios Hoshod Households*0 With ithot Exerna Reunn Reunn Spca Schoo Trni Thrug 1 22% 78% 96% 50% 22% 0% 10% 100% 100%
2 22% 78% 96% 50% 22% 0% 10% 100% 100%
3 2% 98% 10% 75% 20% 0% 0% 100% 100%
4 2% 98% 10% 75% 20% 0% 0% 100% 100%
5 2% 98% 10% 75% 20% 0% 0% 100% 40%
6 22% 78% 100% 90% 22% 0% 100% 100% 100%
7 22% 78% 100% 90% 22% 0% 100% 100% 100%
8 22% 78% 100% 90% 22% 0% 100% 100% 100%
9 2% 98% 10% 100% 20% 0% 0% 100% 100%
10 2% 98% 10% 100% 20% 0% 0% 100% 100%
11 2% 98% 10% 100% 20% 0% 0% 100% 100%
12 2% 98% 10% 100% 20% 0% 0% 100% 40%
13 22% 78% 100% 90% 22% 100% 100% 100% 100%
14 22% 78% 96% 50% 22% 0% 10% 100% 100%
Resident Households with Commuters ....... Households of EPZ residents who await the return of commuters prior to beginning the evacuation trip.
Resident Households with No Commuters ..Households of EPZ residents who do not have commuters or will not await the return of commuters prior to beginning the evacuation trip.
Employees .................................................. EPZ employees who live outside the EPZ Transients .................................................. People who are in the EPZ at the time of an event for recreational or other (non-employment) purposes.
Shadow ...................................................... Residents and employees in the shadow region (outside of the EPZ) who will spontaneously decide to relocate during the evacuation. The basis for the values shown is a 20% relocation of shadow residents along with a proportional percentage of shadow employees.
Special Events ............................................ Additional vehicles in the EPZ due to the identified special event.
School and Transit Buses ............................ Vehicle-equivalents present on the road during evacuation servicing schools and transit-dependent people (1 bus is equivalent to 2 passenger vehicles).
External Through Traffic ............................. Traffic on interstates/freeways and major arterial roads at the start of the evacuation. This traffic Is stopped by access control 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the evacuation begins.
Wolf Creek Generating Station 6-7 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 6-4. Vehicle Estimates by Scenario 1 836 2,889 414 10 284 - 5 10 2,504 6,952 2 836 2,889 414 10 284 - 5 10 2,504 6,952 3 84 3,641 43 15 259 - - 10 2,504 6,556 4 84 3,641 43 15 259 - 10 2,504 6,556 5 84 3,641 43 15 259 - - 10 1,002 5,054 6 836 2,889 431 18 286 - 46 10 2,504 7,020 7 836 2,889 431 18 286 - 46 10 2,504 7,020 8 836 2,889 431 18 286 - 46 10 2,504 7,020 9 84 3,641 43 20 259 - - 10 2,504 6,561 10 84 3,641 43 20 259 - - 10 2,504 6,561 11 84 3,641 43 20 259 - - 10 2,504 6,561 12 84 3,641 43 20 259 - - 10 1,002 5,059 13 836 2,889 431 18 286 525 46 10 2,504 7,545 14 836 2,889 414 10 284 - 5 10 2,504 6,952 2 Vehicle estimates are for an evacuation of the entire EPZ (Region R03)
Wolf Creek Generating Station 6-8 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
7 GENERAL POPULATION EVACUATION TIME ESTIMATES (ETE)
This section presents the ETE results of the computer analyses using the DYNEV II System described in Appendices B, C and D. These results cover 63 regions within the WCGS EPZ and the 14 Evacuation Scenarios discussed in Section 6.
The ETE for all Evacuation Cases are presented in Table 7-1 and Table 7-2. These tables present the estimated times to clear the indicated population percentages from the Evacuation Regions for all Evacuation Scenarios. The ETE of the 2-mile region in both staged and un-staged regions are presented in Table 7-3 and Table 7-4. Table 7-5 defines the Evacuation Regions considered.
The tabulated values of ETE are obtained from the DYNEV II System outputs which are generated at 5-minute intervals.
7.1 Voluntary Evacuation and Shadow Evacuation "Voluntary evacuees" are people within the EPZ in a subzone for which an Advisory to Evacuate has not been issued, yet who elect to evacuate. "Shadow evacuation" is the voluntary outward movement of some people from the Shadow Region (outside the EPZ) for whom no protective action recommendation has been issued. Both voluntary and shadow evacuations are assumed to take place over the same time frame as the evacuation from within the impacted Evacuation Region.
The ETE for the WCGS EPZ addresses the issue of voluntary evacuees in the manner shown in Figure 7-1. Within the EPZ, 20 percent of people located in subzones outside of the evacuation region, who are not advised to evacuate, are assumed to elect to evacuate. Similarly, it is assumed that 20 percent of those people in the Shadow Region will choose to leave the area.
Figure 7-2 presents the area identified as the Shadow Region. This region extends radially from the plant to cover a region between the EPZ boundary and approximately 15 miles. The population and number of evacuating vehicles in the Shadow Region were estimated using the same methodology that was used for permanent residents within the EPZ (see Section 3.1). As discussed in Section 3.2, it is estimated that a total of 2,114 people reside in the Shadow Region; 20 percent of them would evacuate. See Table 6-4 for the number of evacuating vehicles from the Shadow Region.
Traffic generated within this Shadow Region, traveling away from the WCGS location, has the potential for impeding evacuating vehicles from within the Evacuation Region. All ETE calculations include this shadow traffic movement.
7.2 Staged Evacuation As defined in NUREG/CR-7002, staged evacuation consists of the following:
- 1. Subzones comprising the 2 mile region are advised to evacuate immediately.
- 2. Subzones comprising regions extending from 2 to 5 miles downwind are advised to shelter in-place while the two mile region is cleared.
Wolf Creek Generating Station 7-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
- 3. As vehicles evacuate the 2 mile region, people from 2 to 5 miles downwind continue preparation for evacuation while they shelter.
- 4. The population sheltering in the 2 to 5 mile region is advised to evacuate when approximately 90% of the 2 mile region evacuating traffic crosses the 2 mile region boundary.
- 5. Non-compliance with the shelter recommendation is the same as the shadow evacuation percentage of 20%.
See Section 5.4.2 for additional information on staged evacuation.
7.3 Patterns of Traffic Congestion during Evacuation Figure 7-3 through Figure 7-5 illustrate the patterns of traffic congestion that arise for the case when the entire EPZ (Region R03) is advised to evacuate during the winter, midweek, midday scenario under good weather conditions (Scenario 6).
Traffic congestion, as the term is used here, is defined as Level of Service (LOS) F. LOS F is defined as follows (HCM 2010, page 5-5):
The HCM uses LOS F to define operations that have either broken down (i.e., demand exceeds capacity) or have exceeded a specified service measure value, or combination of service measure values, that most users would consider unsatisfactory. However, particularly for planning applications where different alternatives may be compared, analysts may be interested in knowing just how bad the LOS F condition is. Several measures are available to describe individually, or in combination, the severity of a LOS F condition:
- Demand-to-capacity ratios describe the extent to which capacity is exceeded during the analysis period (e.g., by 1%, 15%, etc.);
- Duration of LOS F describes how long the condition persists (e.g., 15 min, 1 h, 3 h); and
- Spatial extent measures describe the areas affected by LOS F conditions. These include measures such as the back of queue, and the identification of the specific intersection approaches or system elements experiencing LOS F conditions.
All highway "links" which experience LOS F are delineated in these figures by a thick red line; all others are lightly indicated. Figure 7-3 displays the developing congestion within the population center of Burlington, south of WCGS, 45 minutes after the Advisory to Evacuate (ATE). The Housatonic St eastbound approach to US Route 75 is operating at LOS F due to the stop sign and the volume of traffic evacuating Burlington. US Route 75 southbound has service traffic volume that is operating below capacity at LOS D or better.
At one hour after the ATE, congestion (LOS F) has subsided in Burlington as depicted in Figure 7-4. There continues to be traffic volume in Burlington, on US Route 75 southbound and on State Route 58 westbound.
Wolf Creek Generating Station 7-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
At 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 35 minutes after the ATE, as shown in Figure 7-5, all evacuation routes are operating at LOS A, well before the completion of mobilization time at 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and 15 minutes.
The traffic congestion in the study area is very limited due to the presence of several serviceable evacuation routes and the low population density within the EPZ.
7.4 Evacuation Rates Evacuation is a continuous process, as implied by Figure 7-6 through Figure 7-19. These figures indicate the rate at which traffic flows out of the indicated areas for the case of an evacuation of the full EPZ (Region R03) under the indicated conditions. One figure is presented for each scenario considered.
As indicated in Figure 7-6, there is typically a long "tail" to these distributions. Vehicles begin to evacuate an area slowly at first, as people respond to the ATE at different rates. Then traffic demand builds rapidly (slopes of curves increase). When the system becomes congested, traffic exits the EPZ at rates somewhat below capacity until some evacuation routes have cleared. As more routes clear, the aggregate rate of egress slows since many vehicles have already left the EPZ. Towards the end of the process, relatively few evacuation routes service the remaining demand.
This decline in aggregate flow rate, towards the end of the process, is characterized by these curves flattening and gradually becoming horizontal. Ideally, it would be desirable to fully saturate all evacuation routes equally so that all will service traffic near capacity levels and all will clear at the same time. For this ideal situation, all curves would retain the same slope until the end - thus minimizing evacuation time. In reality, this ideal is generally unattainable reflecting the spatial variation in population density, mobilization rates and in highway capacity over the EPZ.
7.5 Evacuation Time Estimate (ETE) Results Table 7-1 and Table 7-2 present the ETE values for all 63 Evacuation Regions and all 14 Evacuation Scenarios. Table 7-3 and Table 7-4 present the ETE values for the 2-mile region for both staged and un-staged keyhole regions downwind to 5 miles. The tables are organized as follows:
Wolf Creek Generating Station 7-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
-I Tabl Cotet ETE represents the elapsed time required for 90 percent of the 7-1 population within a Region, to evacuate from that Region. All Scenarios are considered, as well as Staged Evacuation scenarios.
ETE represents the elapsed time required for 100 percent of the 7-2 population within a Region, to evacuate from that Region. All Scenarios are considered, as well as Staged Evacuation scenarios.
ETE represents the elapsed time required for 90 percent of the 7-3 population within the 2-mile Region, to evacuate from that Region with both Concurrent and Staged Evacuations.
ETE represents the elapsed time required for 100 percent of the 7-4 population within the 2-mile Region, to evacuate from that Region with both Concurrent and Staged Evacuations.
The animation snapshots described above reflect the ETE statistics for the concurrent (un-staged) evacuation scenarios and regions, which are displayed in Figure 7-3 through Figure 7-5.
Congestion within the EPZ is located in Burlington (Subzone SW-i) which is beyond the 2-mile area; this is reflected in the ETE statistics:
" The 9 0 th percentile ETE for Region R01 (2-mile area) is generally between 1:15 (hr:min) and 1:20 (slightly higher for snow).
- The 90th percentile ETE for Regions R02 (5-mile area) and R03 (full EPZ) are approximately a half hour longer.
The 100th percentile ETE for all Regions and for all Scenarios are equal to the mobilization time.
This fact implies that the congestion within the EPZ dissipates prior to the end of mobilization, as is displayed in Figure 7-5.
Comparison of Scenarios 6 and 13 in Table 7-1 indicates that the Special Event - refueling outage at Wolf Creek - does not have a material impact on the ETE for the 90th percentile. The additional 525 employee vehicles at Wolf Creek mobilize quicker than the remainder of the population and due to the limited congestion in the EPZ, employees can evacuate quicker as well. Therefore, the 90th percentile decreases by up to 10 minutes during an outage - not a material change.
Comparison of Scenarios 1 and 14 in Table 7-1 indicates that the roadway closure - a southbound segment of US-75 between 1 0 th Rd and 7 th Ln south of Burlington - does not have a material impact on the 90th percentile ETE. There exists sufficient reserve capacity on other routes exiting the city of Burlington to accommodate evacuees.
7.6 Staged Evacuation Results Table 7-3 and Table 7-4 present a comparison of the ETE compiled for the concurrent (un-staged) and staged evacuation studies. Note that Regions R47 through R63 are the same Wolf Creek Generating Station 7-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
geographic areas as Regions R02 and R04 through R19, respectively.
To determine whether the staged evacuation strategy is worthy of consideration, one must show that the ETE for the 2 mile region can be reduced without significantly affecting the region between 2 miles and 5 miles. In all cases, as shown in these tables, the ETE for the 2 mile region increases by up to 15 minutes (higher during snow scenarios) when a staged evacuation is implemented. This extending of ETE is due to the delay in beginning the evacuation trip experienced by those who shelter for 75 minutes while the 2 mile region clears.
While failing to provide assistance to evacuees from within 2 miles of the WCGS, staging also produces a negative impact on the ETE for those evacuating from within the 5-mile area. A comparison of ETE between Regions R47 through R63 with Regions R02 and R04 through R19, respectively, reveals that staging retards the 90th percentile ETE for those in the 2 to 5-mile area by up to 25 minutes (see Table 7-1). This extending of ETE is also due to the delay in beginning the evacuation trip experienced by those who shelter for 75 minutes while the 2 mile region clears.
In summary, the staged evacuation protective action strategy provides no benefits to those evacuating from the 2 mile region because there is limited traffic congestion in the area, and adversely impacts many evacuees located beyond 2 miles from the WCGS.
7.7 Guidance on Using ETE Tables The user first determines the percentile of population for which the ETE is sought (The NRC guidance calls for the 90th percentile). The applicable value of ETE within the chosen Table may then be identified using the following procedure:
- 1. Identify the applicable Scenario:
" Season
" Summer
" Winter (also Autumn and Spring)
- Day of Week
" Midweek
" Weekend
" Time of Day
" Midday
" Evening
- Weather Condition
" Good Weather
" Rain
" Snow
" Special Event
" Wolf Creek Refueling Outage
" Road Closure (a segment on US-75 southbound is closed)
- Evacuation Staging E No, Staged Evacuation is not considered Wolf Creek Generating Station 7-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
0 Yes, Staged Evacuation is considered While these Scenarios are designed, in aggregate, to represent conditions throughout the year, some further clarification is warranted:
- The conditions of a summer evening (either midweek or weekend) and rain are not explicitly identified in the Tables. For these conditions, Scenarios (2) and (4) apply.
- The conditions of a winter evening (either midweek or weekend) and rain are not explicitly identified in the Tables. For these conditions, Scenarios (7) and (10) for rain apply.
- The conditions of a winter evening (either midweek or weekend) and snow are not explicitly identified in the Tables. For these conditions, Scenarios (8) and (11) for snow apply.
- The seasons are defined as follows:
" Summer assumes that public schools are not in session.
" Winter (includes Spring and Autumn) considers that public schools are in session.
- Time of Day: Midday implies the time over which most commuters are at work or are travelling to/from work.
- 2. With the desired percentile ETE and Scenario identified, now identify the Evacuation Region:
- Determine the projected azimuth direction of the plume (coincident with the wind direction). This direction is expressed in terms of compass orientation in degrees (00 is North).
- Determine the distance that the Evacuation Region will extend from the nuclear power plant. The applicable distances and their associated candidate Regions are given below:
0 2 Miles (Region R01) 0 To 5 Miles (Region R02, R04 through R19)
E To EPZ Boundary (Regions R03, R20 through R46)
- Enter Table 7-5 and identify the applicable group of candidate Regions based on the distance that the selected Region extends from the WCGS. Select the Evacuation Region identifier in that row, based on the azimuth direction of the plume, from the first column of the Table.
- 3. Determine the ETE Table based on the percentile selected. Then, for the Scenario identified in Step 1 and the Region identified in Step 2, proceed as follows:
- The columns of Table 7-1 are labeled with the Scenario numbers. Identify the proper column in the selected Table using the Scenario number defined in Step 1.
- Identify the row in this table that provides ETE values for the Region identified in Step 2.
- The unique data cell defined by the column and row so determined contains the desired value of ETE expressed in Hours:Minutes.
Wolf Creek Generating Station 7-6 KLD Eneineerine.I P.C.
Evacuation Time Estimate Rev. 1
Example It is desired to identify the ETE for the following conditions:
- Sunday, August 10th at 4:00 AM.
- It is raining.
- Wind direction is from 1800.
- Wind speed is such that the distance to be evacuated is judged to be a 2-mile radius and downwind to 10 miles (to EPZ boundary).
- The desired ETE is that value needed to evacuate 90 percent of the population from within the impacted Region.
- A staged evacuation is not desired.
Table 7-1 is applicable because the 90th percentile ETE is desired. Proceed as follows:
- 1. Identify the Scenario as summer, weekend, evening and raining. Entering Table 7-1, it is seen that there is no match for these descriptors. However, the clarification given above assigns this combination of circumstances to Scenario 4.
- 2. Enter Table 7-5 and locate the Region described as "Evacuate 2-Mile Radius and Downwind to the EPZ Boundary" for wind direction from 180' and read Region R33 in the first column of that row.
- 3. Enter Table 7-1 to locate the data cell containing the value of ETE for Scenario 4 and Region R17. This data cell is in column (4) and in the row for Region R33; it contains the ETE value of 1:35.
Wolf Creek Generating Station 7-7 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 7-1. Time to Clear the Indicated Area of 90 Percent of the Affected Population Summer Summer summer Winter Winter Winter Winter Summer Midweek Weekend Midweek 2M5MilweReg, a e MididweeeknMidweek Midweek Weekend Weekend Midday Midday Evening FMidday Midday Evening Midday Midday Region Good Rain Good Fan Good Good Rain Snow Good.e Snw Weathe God Secia Impadwa Weather Weather Ran Weather IWeather ýIWahrWahr Eet Ipc Entire 2-Mile Region, 5-Mile Region, and EPZ Rol 1:15 1:1511:2011:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:05 1:15 R02 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R03 1:50 1:55 1:40 1:40 1:40 1:50 1:55 2:40 [ 1:40 1:40 2:30 1:40 1:50 1:55 2-Mile Region and Keyhole to 5 Miles R04 1:30 1:30 1:25 1:30 1:25 1:30 1:30 2:00 1:25 1:30 2:15 1:25 1:20 1:30 ROS 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R06 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R07 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R08 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R09 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 RIO 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:50 Rll 1:30 1:30 1:25 1:30 1:25 1:30 1:30 2:00 1:25 1:30 2:15 1:25 1:20 1:30 R12 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:05 1:30 1:30 2:15 1:30 1:25 1:30 R13 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:45 1:25 1:25 2:00 1:25 1:15 1:25 R14 1:20 1:20 1:20 1:25 1:20 1:20 1:20 1:40 1:20 1:25 2:00 1:15 1:15 1:20 R1S 1:20 1:25 1:25 1:25 1:25 1:20 1:20 1:45 1:25 1:25 2:00 1:20 1:15 1:20 R16 1:20 1:20 1:25 1:25 1:25 1:20 1:20 1:40 1:25 1:25 2:00 1:20 1:15 1:20 R17 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:45 1:25 1:25 2:00 1:25 1:15 1:25 R18 1:20 1:20 1:25 1:25 1:25 1:20 1:20 1:45 1:25 1:25 2:00 1:20 1:15 1:20 R19 1:30 1:35 1:30 1:30 1:30 1:30 1:35 2:05 1:30 1:30 2:15 1:30 1:25 1:30 2-Mile Region and Keyhole to EPZ Boundary R20 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:25 1:35 1:35 2:25 1:35 1:35 1:45 R21 1:50 1:50 1:40 1:40 1:40 1:50 1:50 2:35 1:40 1:40 2:30 1:40 1:45 1:55 R22 1:50 1:50 1:40 1:40 1:40 1:50 1:50 2:35 1:40 1:40 2:30 1:40 1:45 1:55 Wolf Creek Generating Station 7-8 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Ran Good Good Ri Snw Good Ri Snw Good Special Roadway Weather ____Weather Ran Weather Weather Weather Wahr Eet Ipc R23 1:50 1:55 1:40 1:40 1:40 1:50 1:50 2:40 1:40 1:40 2:30 1:40 1:45 1:55 R24 1:50 1:55 1:40 1:40 1:40 1:50 1:50 2:35 1:40 1:40 2:30 1:40 1:45 1:55 R25 1.50 1:50 1:35 1:40 1:35 1:50 1:50 2:35 1:35 1:40 2:30 1:35 1:45 1:55 R26 1:50 1:50 1:35 1:40 1:35 1:50 1:50 2:35 1:35 1:40 2:30 1:35 1:45 1:55 R27 1:50 1:50 1:35 1:35 1:35 1:45 1:50 2:30 1:35 1:35 2:25 1:35 1:40 1:50 R28 1:50 1:50 1:35 1:40 1:35 1:50 1:50 2:35 1:35 1:35 2:30 1:35 1:45 1:55 R29 1:40 1:45 1:35 1:40 1:35 1:40 1:45 2:25 1:35 1:40 2:25 1:35 1:35 1:45 R30 1:45 1:45 1:35 1:40 1:35 1:45 1:45 2:25 1:35 1:40 2:25 1:35 1:35 1:45 R31 1:40 1:45 1:35 1:35 1:35 1:40 1:45 2:20 1:35 1:35 2:25 1:35 1:30 1:40 R32 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:30 1:35 1:35 2:25 1:35 1:40 1:45 R33 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:25 1:35 1:35 2:20 1:35 1:35 1:45 R34 1:40 1:45 1:35 1:35 1:35 1:40 1:40 2:20 1:35 1:35 2:20 1:35 1:35 1:40 113S 1:40 1:40 1:30 1:35 1:30 1:40 1:40 2:15 1:30 1:35 2:20 1:30 1:30 1:40 R36 1:40 1:40 1:35 1:35 1:35 1:40 1:40 2:20 1:35 1:35 2:20 1:35 1:35 1:40 R37 1:40 1:40 1:30 1:30 1:30 1:35 1:35 2:15 1:30 1:30 2:15 1:30 1:30 1:40 R38 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R39 1:35 1:35 1:30 1:30, 1:30 1:35 1:35 2:05 1:30 1:30 2:10 1:30 1:25 1:35 R40 1:35 1:35 1:35 1:35 1:35 1:35 1:35 2:10 1:35 1:35 2:10 1:35 1:30 1:35 R41 1:35 1:35 1:30 1:35 1:30 1:35 1:35 2:05 1:30 1:35 2:10 1:30 1:30 1:35 R42 1:40 1:40 1:35 1:35 1:35 1:40 1:40 2:20 1:35 1:35 2:20 1:35 1:30 1:40 R43 1:40 1:40 1:35 1:35 1:35 1:40 1:40 2:20 1:35 1:35 2:20 1:35 1:35 1:40 R44 1:45 1:45 1:35 1:40 1:35 1:45 1:45 2:25 1:35 1:40 2:25 1:35 1:35 1:45 R45 1:45 1:45 1:35 1:35 1:35 1:45 1:45 2:25 1:35 1:35 2:25 1:35 1:35 1:45 R46 1:45 1:45 1:35 1:40 1:35 1:45 1:45 2:25 1:35 1:40 2:25 1:35 1:40 1:45
______ _____ ______ ___StagedEvacuation Mile Region and Keyhole to 5 Miles R47 1:50 11:55 1:50 1:50 1:5011:50 1:55 2:3011:5011:502:30 1:50 1:501 2:05 R48 1:35 j1:35 1:35 1:35 1:35 1:35 1:35 2:10 1:35 j1:35 2:15 1:35 1:30 1:35 R49 1:50 j1:55 1:50 1:50 1:50 1:50 1:55 2:30 j 1:50 j1:50 2:30 1:50 1:50 j 2:05 Wolf Creek Generating Station 7-9 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Weekend Midweek Weekend Weekend Weekend Midweek Midweek Scen rio (1) (2) (3) (4)] [(5] [(6)
(7) (8) (910) (11) (12) (13) (14)
Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Special Roadway Weather Weather Weather Weather Weather Weather Event Impact RSO 1:50 1:55 1:50 1:50 1:50 1:50 1:55 2:30 1:50 1:50 2:30 1:50 1:50 2:05 R51 1:50 1:55 1:50 1:50 1:50 1:50 1:55 2:30 1:50 1:50 2:30 1:50 1:50 2:05 R52 1:50 1:55 1:50 1:50 1:50 1:50 1:55 2:30 1:50 1:50 2:30 1:50 1:50 2:05 R53 1:50 1:55 1:50 1:50 1:50 1:50 1:55 2:30 1:50 1:50 2:30 1:50 1:50 2:05 R54 1:50 1:55 1:50 1:50 1:50 1:50 1:55 2:30 1:50 1:50 2:30 1:50 1:50 2:05 R55 1:35 1:35 1:35 1:35 1:35 1:35 1:35 2:10 1:35 1:35 2:20 1:35 1:30 1:35 R56 1:40 1:40 1:40 1:40 1:40 1:40 1:40 2:20 1:40 1:40 2:20 1:40 1:35 1:40 R57 1:30 1:35 1:35 1:35 1:35 1:30 1:30 2:00 1:35 1:35 2:10 1:30 1:25 1:30 R58 1:30 1:30 1:35 1:35 1:35 1:30 1:30 2:05 1:35 1:35 2:10 1:30 1:25 1:30 R59 1:30 1:35 1:35 1:35 1:35 1:30 1:35 2:05 1:35 1:35 2:10 1:30 1:30 1:30 R60 1:30 1:30 1:35 1:35 1:35 1:30 1:30 2:00 1:35 1:35 2:10 1:30 1:25 1:30 R61 1:35 1:35 1:35 1:35 1:35 1:35 1:35 2:05 1:35 1:35 2:10 1:35 1:30 1:35 R62 1:30 1:30 1:35 1:35 1:35 1:30 1:30 2:05 1:35 1:35 2:10 1:30 1:25 1:30 R63 1:30 1:35 1:35 1:35 1:35 1:30 1:35 2:05 1:35 1:35 2:15 1:30 1:30 1:30 Wolf Creek Generating Station 7-10 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 7-2. Time to Clear the Indicated Area of 100 Percent of the Affected Population Region Good Ran Good Ran Good Good Ran So God ai Sow od Spcl Rawy Weather Weather Weather Weather RIn Sno RaintSno Weather Event Impact
_______ ________Entire 2-Mile Region, 5-Mile Region, and EPZ ______ ____ ____
ROl 4:15 4:15 4:15 4:15 14:15 J4:15 4:15 5:15 4:15 J4:15 5:15 4:15 4:15 J4:15 R02 4:20 4:20 4:20 4:20 4:20 j4:20 4:20 j5:20 4:20 4:20 j5:20 4:20 4:20 j4:20 R03 4:25 4:25 4:25 4:25 J 4:25 4:25 4:25 J5:25 J4:25 14:25 15:25 4:25 4:25 4:25 2-Mile Region and Keyhole to 5 Miles R04 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R05 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R06 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R07 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R08 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R09 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R10 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R11 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R12 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R13 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R14 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R15 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R16 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R17 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R18 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R19 4:20 4:20 4:20 4:20 4:20 4:20 4:20 15:20 14:20 4:20 5:20 4:20 4:20 4:20
_____ _______ 2-Mile Region and Keyhole to EPZ Boundary ______ ________
R20 4:25 4:25 4:25 4:25 4:25 4:25 4:25 j5:25 4:25 4:25 5:25 4:25 4:25 4:25 R21 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R22 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R23 4:25 4:25 4:25 4:25 4:25 j4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 J 4:25 Wolf Creek Generating Station 7-11 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Midday Midday Evening Midday Midday ____Evening Midday Midday Region Good Rain Good Ran Good Good Ri Snw Good Ri Snw Good Special Roadway Weather Weather Ran Weather Weather Weather Wahr Eet Ipc 4:5 Rain Snow 42mpact2 Rain
- 2 Snow
- 5 Weathe
- 5 Event 4:5 42 R25 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R26 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R27 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R28 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R29 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R30 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R31 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R32 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R33 4:25 4:25 4:25 4:2 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R34 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R35 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R36 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R37 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R38 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R39 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:2 4:25 5:25 4:25 4:25 4:25 R40 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R41 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R42 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R43 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:2 5:25 4:25 4:25 4:25 R44 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R45 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R46 4:25 4:25 4:25 4:25 4:25 4:25 14:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R47 4:25 4:25 4:25 4:25 4:25 4:25 4:25 5:25 4:25 4:25 5:25 4:25 4:25 4:25 R48 4:20 4:2014:20 4:20 4:20 4:2014:2015:2014:2014:20 5:20 4:20 4:201 4:20 R49 4:20 4:20 4:20 4:20 4:20 4:20 4:20 j5:20 4:20 4:20 5:20 4:20 4:20 j4:20 RSO 4:20 4:20 4:20 4:20 4:20 4:20 j4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 Wolf Creek Generating Station 7-12 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Weekend Midweek Weekend Weekend Weekend Midweek Midweek Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Special Roadway Weather Weather Weather Weather Weather Weather Event Impact R51 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R52 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R53 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 RS4 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R55 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R56 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R57 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 RS9 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R59 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R60 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R61 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R63 4:20 4:20 4:20 4:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 R63 4:20 14:20 4:20 14:20 4:20 4:20 4:20 5:20 4:20 4:20 5:20 4:20 4:20 4:20 Wolf Creek Generating Station 7-13 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 7-3. Time to Clear 90 Percent of the 2-Mile Area within the Indicated Region Summer Summer summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Midweek .IWeekend Weekend Midweek Midweek Region Good0 Midday Weather Ri Good0Midday RanWeather Ri Good Ran Evening Weather Good0 Weather R So ooo0 Midday RIn So Weather d an So oodo Midday Ri Snw Evening Weather pcilRoda Midday Event Midday Impact Entire 2-Mile Region R01 1:15 1:15 1:20 1:20 1:20 1:15 T-1:153 1:30 1:20 1:20 2:00 1:15 1:05 1:15 S- Mile Region and 2-Mile Region with Keyhole to 5 Miles R04 1:20 1:30 1:25 1:25 1:25 1:30 1:30 1:55 1:25 1:25 2:10 1:25 1:20 1:30 RO4 1:20 1:20 1:25 1:25 1:25 1:20 1:20 1:35 1:25 1:25 2:00 1:20 1:10 1:20 ROS 1:20 1:20 1:20 1:25 1:25 1:20 1:20 1:35 1:25 1:25 2:00 1:20 1:10 1:20 R06 1:15 1:20 1:20 1:20 1:20 1:15 1:15 1:35 1:20 1:20 2:00 1:15 1:10 1:15 R07 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:20 1:25 RO8 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:15 1:25 RO9 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:15 1:25 RIO 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:15 1:25 R11 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:15 1:25 R12 1:25 1:25 1:25 1:25 1:25 1:25 1:25 1:55 1:25 1:25 2:15 1:25 1:15 1:25 R13 1:15 1:15 1:20 1:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:10 1:15 R14 1:15 1:15 1:20 1:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:10 1:15 R15 1:15 1:15 1:20 1:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:10 1:15 R16 1:15 1:15 1:20 1:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:05 1:15 R17 1:15 1:15 1:20 1:20 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:10 1:15 R18 1:15 1:15 1:25 1:25 1:20 1:15 1:15 1:30 1:20 1:20 2:00 1:15 1:10 1:15 R19 1:20 1:20 1:25 1:25 1:25 1:20 1:20 1:35 1:25 1:25 2:00 1:20 1:10 1:20 Staged Evacuation Mile Region and Keyhole to 5 Miles R47 1:35 1:35 1:35 1:35 1:35 1:30 1:35 2:05 1:35 1:35 2:15 1:30 1:30 1:35 R48 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:20 1:30 R49 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:20 1:30 R50 1:25 1:25 1:30 1:30 1:30 1:25 1:25 1:55 1:30 1:30 2:05 1:25 1:20 1:25 R51 1:30 1:35 1:30 1:35 1:30 1:30 1:30 2:05 1:30 1:35 2:15 1:30 1:30 1:30 Wolf Creek Generating Station 7-14 KLD Engineering, P.C, Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Weekend Midweek Weekend Weekend Weekend Midweek Midweek Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Special Roadway Weather Weather Weather Weather Weather Weather Event Impact RR2 1:30 1:30 1:30 1:35 1:30 1:30 1:30 2:05 1:30 1:35 2:15 1:30 1:30 1:30 R53 1:30 1:30 1.30 1:35 1:30 1:30 1:30 2:05 1:30 1:35 2:15 1:30 1:30 1:30 R54 1:30 1:30 1:30 1:35 1:30 1:30 1:30 2:05 1:30 1:35 2:15 1:30 1:30 1:30 R54 1:30 1:30 1:30 1:35 1:30 1:30 1:30 2:05 1:30 1:35 2:15 1:30 1:30 1:30 R56 1:35 1:35 1:35 1:35 1:30 1:30 1:35 2:05 1:35 1:35 2:15 1:30 1:30 1:35 R57 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R58 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R59 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R60 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R61 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R62 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:30 2:05 1:30 1:25 1:30 R63 1:30 1:30 1:30 1:30 1:30 1:30 1:30 2:00 1:30 1:35 2:05 1:30 1:25 1:30 Wolf Creek Generating Station 7-15 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 7-4. Time to Clear 100 Percent of the 2-Mile Area within the Indicated Region Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Weekend Weekend MdekMidweek Weekend MdekMidweek Midweek IWeekend IWeekend Midday Midday Evening Midday Midday Evening Midday Midday Region eGood Rain Good Rain Good Good R S Good Rain Snow Good Special Roadway Weather Weather Weather Weather Rain Snow Rain Snow Weather Event Impact Entire 2-Mile Region R01 4:15 4:15 4:15 4:15 4:15 4:15 ] 4:15 5:15 1 4:15 4:15 5:15 4:15 4:15 4:15 5- Mile Region and 2-Mile Region with Keyhole to 5 Miles R02 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R04 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R05 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R06 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R07 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 RO 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R09 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 RIO 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R11 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R12 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R13 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R14 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R15 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R16 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R17 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R18 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R19 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 Staged Evacuation Mile Region and Keyhole to 5 Miles R47 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R48 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R49 4:15 4:15 4:15 4:15 4:15 4:15 _ __ _ _15 4:15 4:15 R50 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R51 4:15 4:15 4:15 4:15 415 4 :15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 Wolf Creek Generating Station 7-16 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Weekend Midweek Weekend Weekend Weekend Midweek Midweek Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Good Special Roadway Weather Weather Weather Weather Rain Weather Weather Event Impact R52 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R53 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R54 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R55 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R56 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R57 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R58 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R59 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:1A 5:15 4:15 4:15 4:15 R60 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R61 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R62 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 R63 4:15 4:15 4:15 4:15 4:15 4:15 4:15 5:15 4:15 4:15 5:15 4:15 4:15 4:15 Wolf Creek Generating Station 7-17 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 7-5. Description of Evacuation Regions Rein Radial Subzones Region Evacuation . . .. . . . . . ... . ..
RO 2-Mile Ring R02 5-Mile Ring
........ C.
Region IWind Direction Subzones From (Degrees): N-i N-2 NE-i NE-2 NE-3 E-1 E-2 SE-2 SE-3 SE-4 S- iS-2 SW-i SW-2 W-1 W-2 RR NW.
R4 354- 6 RO 97 - 16 R06 ~17 -27 lp R7 28 -67 RB 68 -73 R13 174 -196 R14 197-207 R15 208-248 R16 249-275 R7 276 -281 Ri8 282- 298 R19 299 - 353 Wolf Creek Generating Station 7-18 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
KLD Engineering, P.C.
Wolf Creek Generating Station 7-19 7-19 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
I R43 299-315 R44 316-331 R45 332 - 343 R46 344-353 Wind Direction Subzones Region From:
R47 5-Mile Ring R48 354-6 R49 7-16 R50 17- 27 R51 28-67 R52 68-73 R53 74- 96 R54 97- 106 R55 107 - 162 R56 163 - 173 R57 174-196 R58 197-207 R59 208-248 R60 249-275 R61 276-281 R62 282-298 R63 299-353 Subzone(s) Shelter-in-Place Wolf Creek Generating Station 7-20 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 7-1. Voluntary Evacuation Methodology Wolf Creek Generating Station 7-21 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 7-2. WCGS Shadow Region KLD Engineering, P.C.
Wolf Creek Generating Station 7-22 7-22 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 7-3. Congestion Patterns at 45 Minutes after the Advisory to Evacuate KLD Engineering, P.C.
Wolf Creek Generating Station 7-23 7-23 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 7-4. Congestion Patterns at I Hour after the Advisory to Evacuate KLD Engineering, P.C.
Wolf Creek Generating Station 7-24 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 7-5. Congestion Patterns at 1 Hour and 35 Minutes after the Advisory to Evacuate Wolf Creek Generating Station 7-25 KLD Engineering, P.C.
KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Summer, Midweek, Midday, Good (Scenario 1)
Mile Region Mile Region - Entire EPZ 0 90% 0 100%
5
.*2 to0 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-6. Evacuation Time Estimates - Scenario 1 for Region R03 Evacuation Time Estimates Summer, Midweek, Midday, Rain (Scenario 2)
- 2-Mile Region - 5-Mile Region - Entire EPZ
- 90% 0 100%
5 4
&Z LU 3A
- E I-1 /Z000" 0
0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-7. Evacuation Time Estimates - Scenario 2 for Region R03 KLD Engineering, P.C.
Wolf Creek Generating Station Creek Generating Station 7-26 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Summer, Weekend, Midday, Good (Scenario 3)
- 2-Mile Region l5-Mile Region - Entire EPZ
- 90% 0 100%
5 m
- o 4 3
MU Z-0009w-2 a)
> 1 0 I 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-8. Evacuation Time Estimates - Scenario 3 for Region R03 Evacuation Time Estimates Summer, Weekend, Midday, Rain (Scenario 4)
Mile Region Mile Region -Entire EPZ 0 90% 0 100%
5 2
4
>C 0
0 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-9. Evacuation Time Estimates - Scenario 4 for Region R03 KLD Engineering, P.C.
Generating Station Creek Generating Wolf Creek Station 7-27 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Summer, Midweek, Weekend, Evening, Good (Scenario 5)
- 2-Mile Region - 5-Mile Region - Entire EPZ
- 90% 0 100%
5 4 -
4a
> 1 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-10. Evacuation lime Estimates - Scenario 5 for Region R03 Evacuation Time Estimates Winter, Midweek, Midday, Good (Scenario 6)
Mile Region Mile Region -,,-Entire EPZ *90% *100%
5 tican J=2
/zoo" AWL 0
0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-11. Evacuation rime Estimates - Scenario 6 for Region R03 Wolf Creek Generating Station 7-28 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Winter, Midweek, Midday, Rain (Scenario 7)
ZI-O
- 2-Mile Region Mile Region -Entire EPZ 9 90%
- 100%
5 4
U-o2 Z OO I I I 1
0 0 30 60 90 120 150 180 210 2 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-12. Evacuation rime Estimates - Scenario 7 for Region R03 Evacuation Time Estimates Winter, Midweek, Midday, Snow (Scenario 8)
Mile Region - 5-Mile Region - Entire EPZ 0 90% 0 100%
5 4
3 LU 02 1
0 0 30 60 90 120 150 180 210 240 270 300 330 Elapsed Time After Evacuation Recommendation (min)
Figure 7-13. Evacuation lime Estimates - Scenario 8 for Region R03 KLD Engineering, P.C.
Wolf Creek Generating Station 7-29 7-29 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Winter, Weekend, Midday, Good (Scenario 9)
Mile Region 15-Mile Region -Entire EPZ
- 90% 0 100%
5 tNo 4
.S 41 3
M LU in 0 1 .1 L t .LMEW Go 2
- E 1
0 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-14. Evacuation Time Estimates - Scenario 9 for Region R03 Evacuation Time Estimates Winter, Weekend, Midday, Rain (Scenario 10)
- 2-Mile Region Mile Region -Entire EPZ 0 90% 0 100%
5 h 4 mom U'-
0 0
/'00ý or 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-15. Evacuation Time Estimates - Scenario 10 for Region R03 Wolf Creek Generating Station 7-30 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Winter, Weekend, Midday, Snow (Scenario 11)
- 2-Mile Region Mile Region - Entire EPZ 0 90% 0 100%
5 bo 4
.A wo2
> 2 05 0)
Jl 0 30 60 90 120 150 180 210 240 270 300 330 Elapsed Time After Evacuation Recommendation (min)
Figure 7-16. Evacuation Time Estimates - Scenario 11 for Region R03 Evacuation Time Estimates Winter, Midweek, Weekend, Evening, Good (Scenario 12)
- 2-Mile Region - 5-Mile Region - Entire EPZ 9 90%
- 100%
5 4
U, A __
/ Ooeý_
U'-
2 0t
/Z000'"
0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-17. Evacuation Time Estimates - Scenario 12 for Region R03 KLD Engineering, P.C.
Wolf Creek Generating Station Creek Generating Station 7-31 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Evacuation Time Estimates Winter, Midweek, Midday, Good, Special Event (Scenario 13)
- 2-Mile Region - 5-Mile Region - Entire EPZ 0 90% 0 100%
6 5
.m e- 4 u- 3 0
"R 1 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-18. Evacuation Time Estimates - Scenario 13 for Region R03 Evacuation Time Estimates Summer, Midweek, Midday, Good, Roadway Impact (Scenario 14)
Mile Region Mile Region -Entire EPZ 0 90% 0 100%
5 4
41 4A
'cc
'A 1
0 0 30 60 90 120 150 180 210 240 270 Elapsed Time After Evacuation Recommendation (min)
Figure 7-19. Evacuation Time Estimates - Scenario 14 for Region R03 Wolf Creek Generating Station 7-32 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
8 TRANSIT-DEPENDENT AND SPECIAL FACILITY EVACUATION TIME ESTIMATES This section details the analyses applied and the results obtained in the form of evacuation time estimates for transit vehicles. The demand for transit service reflects the needs of three population groups: (1) residents with no vehicles available; (2) residents of special facilities such as schools, medical facilities, and correctional facilities; and (3) homebound special needs population.
These transit vehicles mix with the general evacuation traffic that is comprised mostly of "passenger cars" (pc's). The presence of each transit vehicle in the evacuating traffic stream is represented within the modeling paradigm described in Appendix D as equivalent to two pc's.
This equivalence factor represents the longer size and more sluggish operating characteristics of a transit vehicle, relative to those of a pc.
Transit vehicles must be mobilized in preparation for their respective evacuation missions.
Specifically:
- Bus drivers must be alerted
- They must travel to the bus depot
- They must be briefed there and assigned to a route or facility These activities consume time. Based on discussion with the offsite agencies, it is estimated that bus mobilization time will average approximately 30 minutes extending from the Advisory to Evacuate, to the time when buses first arrive at the facility to be evacuated.
During this mobilization period, other mobilization activities are taking place. One of these is the action taken by parents, neighbors, relatives and friends to pick up children from school prior to the arrival of buses, so that they may join their families. Virtually all studies of evacuations have concluded that this "bonding" process of uniting families is universally prevalent during emergencies and should be anticipated in the planning process. The current public information disseminated to residents of the WCGS EPZ indicates that superintendents will be contacted at levels of Site Area Emergency or higher, and that parents should pick schoolchildren up at the reception and care center if an evacuation is ordered. As discussed in Section 2, this study assumes a fast breaking general emergency. Therefore, children are evacuated to the reception and care centers. Picking up children at school could add to traffic congestion at the schools, delaying the departure of the buses evacuating schoolchildren, which may have to return in a subsequent "wave" to the EPZ to evacuate the transit-dependent population. This report provides estimates of buses under the assumption that no children will be picked up by their parents (in accordance with NUREG/CR-7002), to present an upper bound estimate of buses required. It is assumed that children at day-care centers are picked up by parents or guardians and that the time to perform this activity is included in the trip generation times discussed in Section 5.
The procedure for computing transit-dependent ETE is to:
- Estimate demand for transit service Wolf Creek Generating Station 8-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
- Estimate time to perform all transit functions
- Estimate route travel times to the EPZ boundary and to the reception and care center 8.1 Transit Dependent People Demand Estimate The telephone survey (see Appendix F) results were used to estimate the portion of the population requiring transit service:
- Those persons in households that do not have a vehicle available.
- Those persons in households that do have vehicle(s) that would not be available at the time the evacuation is advised.
In the latter group, the vehicle(s) may be used by a commuter(s) who does not return (or is not expected to return) home to evacuate the household.
Table 8-1 presents estimates of transit-dependent people. Note:
Estimates of persons requiring transit vehicles include schoolchildren. For those evacuation scenarios where children are at school when an evacuation is ordered, separate transportation is provided for the schoolchildren. The actual need for transit vehicles by residents is thereby less than the given estimates. However, estimates of transit vehicles are not reduced when schools are in session.
It is reasonable and appropriate to consider that many transit-dependent persons will evacuate by ride-sharing with neighbors, friends or family. For example, nearly 80 percent of those who evacuated from Mississauga, Ontario who did not use their own cars, shared a ride with neighbors or friends. Other documents report that approximately 70 percent of transit dependent persons were evacuated via ride sharing. We will adopt a conservative estimate that 50 percent of transit dependent persons will ride share, in accordance with NUREG/CR-7002.
The estimated number of bus trips needed to service transit-dependent persons is based on an estimate of average bus occupancy of 30 persons at the conclusion of the bus run. Transit vehicle seating capacities typically equal or exceed 60 children on average (roughly equivalent to 40 adults). If transit vehicle evacuees are two thirds adults and one third children, then the number of "adult seats" taken by 30 persons is 20 + (2/3 xl0) = 27. On this basis, the average load factor anticipated is (27/40) x 100 = 68 percent. Thus, if the actual demand for service exceeds the estimates of Table 8-1 by 50 percent, the demand for service can still be accommodated by the available bus seating capacity.
[20 + 2x 10)] + 40 x 1.5 = 1.00 Table 8-1 indicates that transportation must be provided for 92 people. Therefore, a total of 4 bus runs are required to transport this population to reception and care centers.
Wolf Creek Generating Station 8-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
To illustrate this estimation procedure, we calculate the number of persons, P, requiring public transit or ride-share, and the number of buses, B, required for the WCGS EPZ:
n P = No. of HH x Y'(%HH with i vehicles) x [(Average HH Size) - i]} x A'C' i=0 Where, A = Percent of households with commuters C = Percent of households who will not await the return of a commuter P = 2,778 x [0.017 x 1.80 + 0.241 x (1.40 - 1) x 0.51 x 0.56 + 0.405 x (2.23 - 2) x (0.51 x 0.56)2] = 183 B=(0.5xP)+-30=4 These calculations are explained as follows:
All members (1.80 avg.) of households (HH) with no vehicles (1.7%) will evacuate by public transit or ride-share. The term 2,778 (number of households) x 0.017 x 1.80, accounts for these people.
The members of HH with 1 vehicle away (24.1%), who are at home, equal (1.40-1).
The number of HH where the commuter will not return home is equal to (2,778 x 0.241 x 0.51 x 0.56), as 51% of EPZ households have a commuter, 56% of which would not return home in the event of an emergency. The number of persons who will evacuate by public transit or ride-share is equal to the product of these two terms.
The members of HH with 2 vehicles that are away (40.5%), who are at home, equal (2.23 - 2). The number of HH where neither commuter will return home is equal to 2,778 x 0.405 x (0.51 x 0.56)2. The number of persons who will evacuate by public transit or ride-share is equal to the product of these two terms (the last term is squared to represent the probability that neither commuter will return).
Households with 3 or more vehicles are assumed to have no need for transit vehicles.
The total number of persons requiring public transit is the sum of such people in HH with no vehicles, or with 1 or 2 vehicles that are away from home.
The estimate of transit-dependent population in Table 8-1 far exceeds the number of registered transit-dependent persons in the EPZ as provided by the county (discussed below in Section 8.5). This is consistent with the findings of NUREG/CR-6953, Volume 2, in that a large majority of the transit-dependent population within the EPZs of U.S. nuclear plants does not register with their local emergency response agency.
Wolf Creek Generating Station 8-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
8.2 School Population - Transit Demand Table 8-2 presents the school population and transportation requirements for the direct evacuation of all schools within the EPZ for the 2011-2012 school year. This information was provided by the Coffey County EMO. The column in Table 8-2 entitled "Buses Required" specifies the number of buses required for each school under the following set of assumptions and estimates:
- No students will be picked up by their parents prior to the arrival of the buses.
- While many high school students commute to school using private automobiles (as discussed in Section 2.4 of NUREG/CR-7002), the estimate of buses required for school evacuation do not consider the use of these private vehicles.
- Bus capacities supplied by Coffey County EMO were used.
- Those staff members who do not accompany the students will evacuate in their private vehicles.
- No allowance is made for student absenteeism, typically 3 percent daily.
The county can introduce procedures whereby the schools are contacted prior to the dispatch of buses from the depot, to ascertain the current estimate of students to be evacuated. In this way, the number of buses dispatched to the schools will reflect the actual number needed. The need for buses would be reduced by any high school students who have evacuated using private automobiles (if permitted by school authorities). Those buses originally allocated to evacuate schoolchildren that are not needed due to children being picked up by their parents, can be gainfully assigned to service other facilities or those persons who do not have access to private vehicles or to ride-sharing.
Table 8-3 presents a list of schools in the EPZ and their assigned reception and care center.
Students will be transported to this center where they will be subsequently retrieved by their respective families.
8.3 Medical Facility Demand Table 8-4 presents the census of medical facilities in the EPZ. 130 people have been identified as living in, or being treated in, these facilities. The capacity and current census for each facility were provided by the county. This data includes the number of ambulatory, wheelchair-bound and bedridden patients at each facility.
The transportation requirements for the medical facility population are also presented in Table 8-4. The number of ambulance runs is determined by assuming that 2 patients can be accommodated per ambulance trip; the number of wheelchair bus runs assumes 15 wheelchairs per trip and the number of bus runs estimated assumes 30 ambulatory patients per trip.
Wolf Creek Generating Station 8-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
8.4 Evacuation Time Estimates for Transit Dependent People EPZ bus resources are assigned to evacuating schoolchildren (if school is in session at the time of the ATE) as the first priority in the event of an emergency. In the event that the allocation of buses dispatched from the depots to the various facilities and to the bus routes is somewhat "inefficient", or if there is a shortfall of available drivers, then there may be a need for some buses to return to the EPZ from the reception and care center after completing their first evacuation trip, to complete a "second wave" of providing transport service to evacuees. For this reason, the ETE for the transit-dependent population will be calculated for both a one wave transit evacuation and for two waves. Of course, if the impacted Evacuation Region is other than R03 (the entire EPZ), then there will likely be ample transit resources relative to demand in the impacted Region and this discussion of a second wave would likely not apply.
When school evacuation needs are satisfied, subsequent assignments of buses to service the transit-dependent should be sensitive to their mobilization time. Clearly, the buses should be dispatched after people have completed their mobilization activities and are in a position to board the buses when they arrive at the pick-up points.
Evacuation Time Estimates for transit trips were developed using both good weather and adverse weather conditions. Figure 8-1 presents the chronology of events relevant to transit operations. The elapsed time for each activity will now be discussed with reference to Figure 8-1.
Activity: Mobilize Drivers (A--'B--'C)
Mobilization is the elapsed time from the Advisory to Evacuate until the time the buses arrive at the facility to be evacuated. Coffey County EMO indicated that for a rapidly escalating radiological emergency with no observable indication before the fact, school bus drivers would require 30 minutes to be contacted, to travel to the depot, be briefed, and to travel to the transit-dependent facilities. Mobilization time is slightly longer in adverse weather - 40 minutes when raining, 50 minutes when snowing.
Activity: Board Passengers (C-)'D)
Based on discussions with the Coffey County EMO, a loading time of 3 minutes for LeRoy Schools, 4 minutes for Waverly Schools, and 5 minutes for Burlington Schools (8, 9, and 10 minutes for rain and 13, 14, and 15 minutes for snow) for school buses is used.
For multiple stops along a pick-up route (transit-dependent bus routes) estimation of travel time must allow for the delay associated with stopping and starting at each pick-up point. The time, t, required for a bus to decelerate at a rate, "a", expressed in ft/sec/sec, from a speed, "v", expressed in ft/sec, to a stop, is t = v/a. Assuming the same acceleration rate and final speed following the stop yields a total time, T, to service boarding passengers:
T = t+B +t = B+2t = B +-2, a
Where B = Dwell time to service passengers. The total distance, "s" in feet, travelled during the deceleration and acceleration activities is: s = v 2/a. If the bus had not stopped to service Wolf Creek Generating Station 8-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
passengers, but had continued to travel at speed, v, then its travel time over the distance, s, would be: s/v = v/a. Then the total delay (i.e. pickup time, P) to service passengers is:
P = T - -= B+
a a Assigning reasonable estimates:
B = 50 seconds: a generous value for a single passenger, carrying personal items, to board per stop S v = 25 mph = 37 ft/sec
- a = 4 ft/sec/sec, a moderate average rate Then, P = 1 minute per stop. Allowing 30 minutes pick-up time per bus run implies 30 stops per run, for good weather. It is assumed that bus acceleration and speed will be less in rain; total loading time is 40 minutes per bus in rain, 50 minutes in snow.
Activity: Travel to EPZ Boundary (D--E)
School Evacuation Transportation resources available were provided by the Coffey County EMO and are summarized in Table 8-5. Also included in the table are the number of buses needed to evacuate schools, medical facilities, transit-dependent population, homebound special needs (discussed below in Section 8.5) and correctional facilities (discussed below in Section 8.6).
These numbers indicate there are sufficient resources available to evacuate everyone in a single wave, with the exception of the wheelchair population within the EPZ, which requires two waves of wheelchair bus transportation.
The buses servicing the schools are ready to begin their evacuation trips at 33, 34, and 35 minutes for LeRoy Schools, Waverly Schools, and Burlington Schools, respectively after the advisory to evacuate - 30 minutes mobilization time plus 3, 4, and 5 minutes loading time - in good weather. The UNITES software discussed in Section 1.3 was used to define bus routes along the most likely path from a school being evacuated to the EPZ boundary, traveling toward the reception and care center. This is done in UNITES by interactively selecting the series of nodes from the school to the EPZ boundary. Each bus route is given an identification number and is written to the DYNEV II input stream. DYNEV computes the route length and outputs the average speed for each 5 minute interval, for each bus route. The specified bus routes are documented in Table 8-6 (refer to the maps of the link-node analysis network in Appendix K for node locations). Data provided by DYNEV during the appropriate timeframe depending on the mobilization and loading times (i.e., 30 to 35 minutes for Burlington Schools after the advisory to evacuate for good weather) were used to compute the average speed for each route, as follows:
Wolf Creek Generating Station 8-6 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Average Speed (h-)
zn length of link i (mi) 60 min.
1 hr.
- n{ Delay on link i (min.) + length of link i (mi.) . 60 min.
hr.
current speed on link i (i.)
The average speed computed (using this methodology) for the buses servicing each of the schools in the EPZ is shown in Table 8-7 through Table 8-9 for school evacuation, and in Table 8-11 through Table 8-13 for the transit vehicles evacuating transit-dependent persons, which are discussed later. The travel time to the EPZ boundary was computed for each bus using the computed average speed and the distance to the EPZ boundary along the most likely route out of the EPZ. The travel time from the EPZ boundary to the reception and care center was computed assuming an average speed of 45 mph, 41 mph, and 36 mph for good weather, rain and snow, respectively. Speeds were reduced in Table 8-7 through Table 8-9 and in Table 8-11 through Table 8-13 to 55 mph (50 mph for rain - 10% decrease - and 44 mph for snow - 20%
decrease) for those calculated bus speeds which exceed 55 mph, as the school bus speed limit for state routes in Kansas is 55 mph.
Table 8-7 (good weather), Table 8-8 (rain) and Table 8-9 (snow) present the following evacuation time estimates (rounded up to the nearest 5 minutes) for schools in the EPZ: (1) The elapsed time from the Advisory to Evacuate until the bus exits the EPZ; and (2) The elapsed time until the bus reaches the reception and care center. The evacuation time out of the EPZ can be computed as the sum of times associated with Activities A-4B-->C, C->D, and D->E (For example: 30 min. + 4 + 2 = 0:40 for Waverly Grade School, with good weather, rounded up to the nearest 5 minutes). The evacuation time to the reception and care center is determined by adding the time associated with Activity E->F (discussed below), to this EPZ evacuation time.
Evacuation of Transit-DependentPopulation The buses dispatched from the depots to service the transit-dependent evacuees will be scheduled so that they arrive at their respective routes after their passengers have completed their mobilization. As shown in Figure 5-4 (residents with no commuters), 92 percent of the evacuees will complete their mobilization when the buses will begin their routes, approximately 90 minutes after the Advisory to Evacuate. Mobilization time is 10 minutes longer in rain and 20 minutes longer in snow to account for slower travel speeds and reduced roadway capacity.
Those buses servicing the transit-dependent evacuees will first travel along their pick-up routes, then proceed out of the EPZ. Transit-dependent pick-up locations are provided annually to EPZ residents in the emergency preparedness brochure. The county emergency plan does not define bus routes to service these pick-up locations. The 4 bus routes shown graphically in Figure 8-2 and described in Table 8-10 were designed as part of this study to service the major Wolf Creek Generating Station 8-7 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
routes through each subzone and to service the pre-defined pick-up locations. It is assumed that residents will walk to and congregate at these pre-designated pick-up locations, and that they can arrive at the stops within the 90 minute bus mobilization time (good weather). It is also assumed that buses will make flag stops wherein residents walk to the nearest major route and flag down passing buses.
As previously discussed, a pickup time of 30 minutes (good weather) is estimated for 30 individual stops to pick up passengers, including flag stops, with an average of one minute of delay associated with each stop. A longer pickup time of 40 minutes and 50 minutes are used for rain and snow, respectively.
The travel distance along the respective pick-up routes within the EPZ is estimated using the UNITES software. Bus travel times within the EPZ are computed using average speeds computed by DYNEV, using the aforementioned methodology that was used for school evacuation.
Table 8-11 through Table 8-13 present the transit-dependent population evacuation time estimates for each bus route calculated using the above procedures for good weather, rain and snow, respectively.
For example, the ETE for the transit dependent bus route 1 servicing Subzones E-1, E-2, E-3, NE-1, NE-2, and NE-3 is computed as 90 + 20 + 30 = 2:20 for good weather (rounded up to nearest 5 minutes). Here, 20 minutes is the time to travel 17 miles at 51.3 mph, the average speed output by the model for this route starting at 90 minutes. The ETE for a second wave (discussed below) is presented in the event there is a shortfall of available buses or bus drivers, as previously discussed.
Activity: Travel to Reception and Care Centers (E-4F)
The distances from the EPZ boundary to the reception and care center are measured using GIS software along the most likely route from the EPZ exit point to the reception and care center.
The reception and care center is mapped in Figure 10-1. For a one-wave evacuation, this travel time outside the EPZ does not contribute to the ETE. For a two-wave evacuation, the ETE for buses must be considered separately, since it could exceed the ETE for the general public.
Assumed bus speeds of 45 mph, 41 mph, and 36 mph for good weather, rain, and snow, respectively, will be applied for this activity for buses servicing the transit-dependent population.
Activity: Passengers Leave Bus (F->G)
A bus can empty within 5 minutes. The driver takes a 10 minute break.
Activity: Bus Returns to Route for Second Wave Evacuation (G->C)
The buses assigned to return to the EPZ to perform a "second wave" evacuation of transit-dependent evacuees will be those that have already evacuated transit-dependent people who mobilized more quickly. The first wave of transit-dependent people depart the bus, and the bus then returns to the EPZ, travels to its route and proceeds to pick up more transit-dependent evacuees along the route. The travel time back to the EPZ is equal to the travel time Wolf Creek Generating Station 8-8 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
to the reception and care center.
The second-wave ETE for the transit dependent bus route 1 is computed as follows for good weather:
Bus arrives at reception and care center at 2:58 in good weather (2:20 to exit EPZ +
38 minute travel time to reception and care center).
Bus discharges passengers (5 minutes) and driver takes a 10-minute rest: 15 minutes.
Bus returns to EPZ and completes second route: 38 minutes (equal to travel time to reception and care center) + 19 minutes (17 miles @ 54.4 mph) = 57 minutes
- Bus completes pick-ups along route: 30 minutes.
- Bus travels to EPZ boundary: 23 minutes (17 miles @ 45 mph)
- Bus exits EPZ at time 2:20 + 0:38 + 0:15 + 0:57 + 0:30 + 0:23= 5:05 (rounded to nearest 5 minutes) after the Advisory to Evacuate.
The ETE for the completion of the second wave for all transit-dependent bus routes are provided in Table 8-11 through Table 8-13. The average ETE for a two-wave evacuation of transit-dependent people exceeds the ETE for the general population at the 90th percentile.
The relocation of transit-dependent evacuees from the reception and care center to congregate care centers, if the county decides to do so, is not considered in this study.
Evacuation of Medical Facilities The evacuation of these facilities is similar to school evacuation except:
Buses are assigned on the basis of 30 patients to allow for staff to accompany the patients. Wheelchair buses can accommodate 15 patients, and ambulances can accommodate 2 patients.
Loading times of 1 minute, 5 minutes, and 15 minutes per patient are assumed for ambulatory patients, wheelchair bound patients, and bedridden patients, respectively.
Table 8-4 indicates that 4 bus runs, 7 wheelchair bus runs and 2 ambulance runs are needed to service all of the medical facilities in the EPZ. According to Table 8-5, the county can collectively provide 41 buses, 1 van, 6 wheel-chair accessible buses, and 4 ambulances. Thus, there are sufficient resources to evacuate the ambulatory and bedridden persons from the medical facilities in a single wave, but a two-wave evacuation is needed for wheelchair buses evacuating bedridden patients.
As is done for the transit dependent population, it is estimated that mobilization time averages 90 minutes. Specially trained medical support staff (working their regular shift) will be on site to assist in the evacuation of patients. Additional staff (if needed) could be mobilized over this same 90 minute timeframe.
Table 8-14 through Table 8-16 summarize the ETE for medical facilities within the EPZ for good weather, rain, and snow. Average speeds output by the model for Scenario 6 (Scenario 7 for rain and Scenario 8 for snow) Region 3, capped at 55 mph (50 mph for rain and 44 mph for Wolf Creek Generating Station 8-9 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
snow), are used to compute travel time to EPZ boundary. The travel time to the EPZ boundary is computed by dividing the distance to the EPZ boundary by the average travel speed. The ETE is the sum of the mobilization time, total passenger loading time, and travel time out of the EPZ. Concurrent loading on multiple buses, wheelchair buses/vans, and ambulances at capacity is assumed such that the maximum loading times for buses, wheelchair buses and ambulances are 30, 75 and 30 minutes, respectively. All ETE are rounded to the nearest 5 minutes. For example, the calculation of ETE for the Sunset Manor with 6 ambulatory residents during good weather is:
ETE: 90 + 6 x 1 + 1 = 97 min. or 1:40 rounded to the nearest 5 minutes.
It is assumed that medical facility population is directly evacuated to appropriate host medical facilities. Relocation of this population to permanent facilities and/or passing through the reception and care center before arriving at the host facility is not considered in this analysis.
The following outlines the ETE calculation for the second wave of wheelchair buses for medical facilities in good weather:
- a. Medical facility buses arrive at R.C.C. (average value from Table 8-7): 2:15 + 49 minutes (average distance to R.C.C. from Table 8-7 = 36.8 miles @ 45 mph) = 3:05
- b. Unload patients at R.C.C.: 15 minutes.
- c. Driver takes 10 minute rest: 10 minutes.
- d. Travel time back to EPZ: 49 minutes (Average Travel Time to R.C.C.)
- e. Travel time back to facility: 9 minutes (Average Travel Time to EPZ Boundary from Table 8-14)
- f. Total Loading Time: 15 patients per bus @ 15 minutes per patient = 75 minutes
- g. Travel time to EPZ boundary: 5 minutes (6 miles @ 55.0 mph)
ETE: 2:15 + 49 + 15 + 10 + 49 + 9 + 75 + 5 = 5:50 rounded up to the nearest 5 minutes.
8.5 Special Needs Population The Coffey County EMO has a combined registration for transit-dependent and homebound special needs persons. Based on the data provided by the county, there are an estimated 27 homebound special needs people within the EPZ who require transportation assistance to evacuate - 26 of which are wheelchair-bound people and 1 bedridden person.
ETE for Homebound Special Needs Persons Table 8-17 summarizes the ETE for homebound special needs people. The table is categorized by type of vehicle required and then broken down by weather condition. The table takes into consideration the deployment of multiple vehicles to reduce the number of stops per vehicle.
It is conservatively assumed that ambulatory and wheelchair bound special needs households are spaced 3 miles apart and bedridden households are spaced 5 miles apart. Van and bus speeds approximate 20 mph between households and ambulance speeds approximate 30 mph in good weather (10% slower in rain, 20% slower in snow). Mobilization times of 90 minutes were used (100 minutes for rain, and 110 minutes for snow). The last HH is assumed to be 5 Wolf Creek Generating Station 8-10 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
miles from the EPZ boundary, and the network-wide average speed, capped at 55 mph (50 mph for rain and 44 mph for snow), after the last pickup is used to compute travel time. ETE is computed by summing mobilization time, loading time at first household, travel to subsequent households, loading time at subsequent households, and travel time to EPZ boundary. All ETE are rounded to the nearest 5 minutes.
For example, assuming no more than one special needs person per HH implies that 26 wheelchair-bound households need to be serviced. While only 2 buses are needed from a capacity perspective, if 4 buses are deployed to service these special needs HH, then each would require about 7 stops. The following outlines the ETE calculations:
- 1. Assume 4 buses are deployed, each with about 7 stops, to service a total of 26 HH.
- 2. The ETE is calculated as follows:
- a. Buses arrive at the first pickup location: 90 minutes
- b. Load HH members at first pickup: 5 minutes
- c. Travel to subsequent pickup locations: 6 @ 9 minutes = 54 minutes
- d. Load HH members at subsequent pickup locations: 6 @ 5 minutes = 30 minutes
- e. Travel to EPZ boundary: 5 minutes (5 miles @ 55 mph).
ETE: 90 + 5 + 54 + 30 + 5 = 3:05 rounded to the nearest 5 minutes The following outlines the ETE calculations if a second wave in good weather is needed using the remaining medical facility wheelchair buses after the first wave of evacuation service for medical facilities (see Table 8-18):
- h. Medical facility buses arrive at R.C.C. (average value from Table 8-7): 2:15 + 49 minutes (average distance to R.C.C. from Table 8-7 = 36.8 miles @ 45 mph) = 3:05
- i. Unload patients at R.C.C.: 15 minutes.
- j. Driver takes 10 minute rest: 10 minutes.
- k. Travel time back to EPZ: 49 minutes (Average Travel Time to R.C.C.)
I. Bus travels to all stops: 7 stops @ 9 minutes = 63 minutes
- m. Loading time at all stops: 7 stops @ 5 minutes = 35 minutes
- n. Travel time to EPZ boundary: 5 minutes (5 miles @ 55.0 mph)
ETE: 2:15 + 49 + 15 + 10 + 49 + 63 + 35 + 5 = 6:05 rounded up to the nearest 5 minutes.
8.6 Correctional Facilities As detailed in Table E-5, there is one correctional facility within the EPZ - Coffey County Jail.
The total inmate capacity at this facility is 27 persons. One bus is needed to evacuate the facility, based on a capacity of 30 inmates per bus. Mobilization time is assumed to be 90 minutes (100 minutes in rain, 110 minutes in snow). It is conservatively estimated that it takes 60 minutes to load the inmates onto a bus. The inmates would be evacuated to the Lyon County Registration Center. Using GIS software, the shortest route from the facility to the EPZ boundary, traveling away from the plant and toward the host facility, is 7.5 miles. The travel time to traverse 7.5 miles is 8 minutes (average speed is 55 mph at 2:30) in good weather, 9 minutes (50 mph at 2:40) in rain and 10 minutes (44 mph at 2:50) in snow. All ETE are rounded Wolf Creek Generating Station 8-11 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
to the nearest 5 minutes. Coffey County Jail can be evacuated in a single wave.
ETE: 90 + 60 + 8 = 2:40 Rain ETE: 100 + 60 + 9 = 2:50 Snow ETE: 110 + 60+ 10 = 3:00 Wolf Creek Generating Station 8-12 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
(Subsequent Wave)
Time A Advisory to Evacuate B Bus Dispatched from Depot C Bus Arrives at Facility/Pick-up Route D Bus Departs for Reception and Care Center E Bus Exits Region F Bus Arrives at Reception and Care Center G Bus Available for "Second Wave" Evacuation Service A-*B Driver Mobilization B--C Travel to Facility or to Pick-up Route C--+D Passengers Board the Bus D->E Bus Travels Towards Region Boundary E-->F Bus Travels Towards Reception and Care Center Outside the EPZ F-+G Passengers Leave Bus; Driver Takes a Break Figure 8-1. Chronology of Transit Evacuation Operations Wolf Creek Generating Station 8-13 KLD Engineering. P.C.
Evacuation Time Estimate Rev. I
Figure 8-2. Transit-Dependent Bus Routes Wolf Creek Generating Station 8-14 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-1. Transit-Dependent Population Estimates 6,rve A 2.23 27 1.70% Percent wit Esi I d ac ewihI t d N .o d c t d N .o Pe c n H wt N n- Pe p e Eti a e-equiin Re qurn 201 EP Veice No of Veice wit Reunn Reurn Riesarn Puli Public-.
6,196tio 1.0 1.4 2.2 2,778old 1.0% 1 24140.5%er Co1%er56%sor 183enag 50%si Tra2i Wolf Creek Generating Station 8-15 KLD Engineering, P.C.
Evacuation Time Estimate Rev. I
Table 8-2. School Population Demand Estimates S . -.. Sh. Name
. E..
NE-2 Waverly Grade School 102 3 NE-2 Waverly Junior& High School 116 3 SE-3 LeRoy Elementary School 55 2 SE-3 Southern Coffey County High School 70 2 SW-1 Burlington Elementary School 323 5 SW-1 Burlington High School 262 2 SW-1 Burlington Middle School 270 5 SW-1 Rainbow's End 12 1 Table 8-3. Reception and Care Center Scoo Reepio and Car Center Waverly Grade School Waverly Junior & High School LeRoy Elementary School Southern Coffey County High School Emporia State University Burlington Elementary School Burlington High School Burlington Middle School Rainbow's End Wolf Creek Generating Station 8-16 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-4. Medical Facility Transit Demand NE-2 I Sunset Manor I Waverly 42 32 6 26 0 1 2 0 SW-1 Coffey Health System Burlington 36 14 8 3 3 1 1 2 SW-1 Life Care Center Burlington 77 62 12 50 0 1 4 0 SW-1 The Meadows Burlington 36 22 22 0 0 1 0 0 Cfjy County.ubtotal: 191 13 79 Wolf Creek Generating Station 8-17 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-5. Summary of Transportation Resources Trnsortto Whechi fIhhhhhhhhhhhhhhh RhhefW0IsourehhhhhBushhhhhhhhhh eE1I~.1h~~Vans9I s Bushhhe1sI.LU Amb~EiI*uflances USD 244 15 1 USD 243 12 -
USD 245 12 1 -
Coffey County EMS - - 4 Coffey County Transportation 2 4 -
Wolf Creek Generating Station 8-18 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-6. Bus Route Descriptions Bu Rout Noe Trvese fro Rot Str to Nube Decrpto EP Boundary Waverly Grade School 1 Waverly Junior & High School 57,220,239,2 Sunset Manor 2 TD Route 1 156, 107, 57, 220, 239, 2 3 TD Route 4 111, 241, 129, 112 LeRoy Elementary School 4 Southern Coffey County High School 165, 164, 154, 261, 245, 4, 5, 279, 83 Coffey Health System Life Care Center The Meadows Burlington Elementary School 5 Coffey County Jail 153, 223, 81, 90, 82, 114 Burlington High School Burlington Middle School Rainbow's End 6 TD Route 3 153, 6, 142, 125, 243, 5, 279, 83 7 TD Route 2 86, 9, 10, 228, 11, 257, 13 KLD Engineering, P.C.
Wolf Generating Station Creek Generating Wolf Creek Station 8-19 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-7. School Evacuation Time Estimates - Good Weather waveriy uraae clcnooi Ju 4 U.8 4U.U z 3b.4 49 Waverly Junior & High School 30 4 0.7 40.0 1 36.4 49 LeRoy Elementary School 30 3 11.0 46.8 15 41.9 56 Southern Coffey County High School 30 3 11.0 46.8 15 41.9 56 Burlington Elementary School 30 5 7.5 47.4 10 32.0 43 Burlington High School 30 5 7.6 47.4 10 32.0 43 Burlington Middle School 30 5 7.7 47.4 10 32.0 43 Rainbow's End 30 5 7.9 47.3 11 32.0 43 Maximum for EPZ: Maximum:
Average for Average:
Wolf Creek Generating Station 8-20 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-8. School Evacuation Time Estimates - Rain Wolf Creek Generating Station 8-21 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-9. School Evacuation lime Estimates - Snow waverly uraae :cnooi 14 2 Sb.4 bI Waverly Junior & High School 50 14 0.7 31.9 2 36.4 61 LeRoy Elementary School 50 13 11.0 36.5 19 41.9 70 Southern Coffey County High School 50 13 11.0 36.5 19 41.9 70 Burlington Elementary School 50 15 7.5 35.9 13 32.0 54 Burlington High School 50 15 7.6 35.9 13 32.0 54 Burlington Middle School 50 15 7.7 35.9 13 32.0 54 Rainbow's End 50 15 7.9 35.9 14 32.0 54 Maximum:
Average:
Wolf Creek Generating Station 8-22 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-10. Summary of Transit-Dependent Bus Routes No of S.boe Legt Roul1te Buses& Rot Descr~UBL¶iptI~eioSevcd(
Start at intersection with Trefoil Rd and 16th Rd at the intersection of Subzones NE-1, E-1, and NE-3. Northbound on Trefoil Rd (turns into Pearson Ave). Collect E-1, E-2, E-3, NE-1 I transit dependent people at High School Gym at 513 Pearson Ave. Continue 17.0 1, NE-2, & NE-3 northbound on Pearson Ave. Left onto Old State Hwy 50 westbound to EPZ boundary Start at intersection of US 75 and Lake Rd in New Strawn in between Subzones CTR, W-1, JRR, 2 1 W-1 and CTR. Northbound on US 75 to EPZ boundary NW-i, NW-2, N- 10.9 1, & N-2 Starts at the intersection of 12th Rd and N 4th St in Burlington in Subzone SW-1.
Southbound on N 4th St. Left onto W Neosho St. eastbound. Collect transit W-2, S S 3 1 dependent people at Senior Citizen Building at 204 W Neosho St. in Burlington. 2, S-1, &
S 5-2 10.9 Head westbound on W Neosho St. Left to continue N 4th St. southbound right onto SH 58 westbound to EPZ boundary.
Starts at the intersection of 12th Rd and Shetland Rd at the boundary of 4 1 Subzones E-1 and SE-i. Southbound on Shetland Rd. Right onto 11th St. SE-1, SE-2, SE-3, 19.1 westbound. Collect transit dependent people at High School Gym at 305 11th St. & SE-4 Left onto C St. southbound. Right onto SH 58 to EPZ boundary.
Total: 1 4 Wolf Creek Generating Station 8-23 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-11. Transit-Dependent Evacuation Time Estimates - Good Weather Table 8-12. Transit-Dependent Evacuation Time Estimates - Rain 1 1 100 17.0 46.4 22 40 28.7 1 42 II 5 I 10 I 88 II 40 I I 2 1 100 10.9 50.0 13 40 28.7 1 42 5 1 10 1 71 1 40 3 1 100 10.9 37.0 18 40 42.0 1 61 5 10 1 92 1 40 4 1 100 19.1 38.8 30 40 42.0 1 61 I 5 I 10 I 115 1 40 Maximum ETE: Maximum ETE:
Average ETE: Average ETE:
Wolf Creek Generating Station 8-24 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-13. Transit Dependent Evacuation Time Estimates - Snow 110 17 ..1 35. 50 28.7 48 5 101 50 2 1 110 10.9 44.0 15 50 28.7 48 5 10 81 so50e 3 1 110 10.9 34.3 19 50 42.0 70 5 10 105 50 4 1 110 19.1 35.7 32 50 42.0 70 5 10 130 50
... ........ .. ... . a....
xim um ET : M axm um ETE:
Average E: Average ETE:
Wolf Creek Generating Station 8-25 KLD Engineering. P.C.
Evacuation Time Estimate Rev. 1
Table 8-14. Medical Facility Evacuation Time Estimates - Good Weather Coffey Health System Wheelchair bound 90 5 3 15 I 7.9 I 1i 2:00 Bedridden 90 15 3 30 7.9 11 2:15 LieCretr Ambulatory 90 1 j 12 j 12 j 7.6 j 11 1:55 Wheelchair bound 90 5 75 7.6 11 3:00 The Meadows Ambulatory 90 1 22 22 7.7 11 2:05 Maximum ETE: 3:00 Average ETE: 2:15 Wolf Creek Generating Station 8-26 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-15. Medical Facility Evacuation Time Estimates - Rain ItBL -- -- I--L _4_ L -- I wneelcnair Douno 100 5 /7 0.8 1 3:bU Ambulatory 100 1 8 8 7.9 12 2:00 Coffey Health System Wheelchair bound 100 5 3 15 7.9 12 2:10 Bedridden 100 15 3 30 7.9 11 2:25 Life Care Center Ambulatory 100 1 12 12 7.6 12 2:05 Wheelchair bound 100 5 50 75 7.6 12 3:10 The Meadows Ambulatory 100 1 22 22 7.7 11 2:15 Maximum ETE: 3:10 Average ETE: 2:25 Wolf Creek Generating Station 8-27 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-16. Medical Facility Evacuation Time Estimates - Snow Ambulatory 110 1 12 12 7.6 13 Life Care Center Wheelchair bound 110 5 50 75 7.6 12 3:20 The Meadows : =Ambulatory j 110 ( 1 22 22 J 7.7 J= 13 2:25 Maximum ETE: 3120 Average ETE: 2:35 Wolf Creek Generating Station 8-28 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table 8-17. Homebound Special Needs Population Evacuation Time Estimates Good 90 0 5 1:50 Ambulances 1 Rain 100 15 0 0 6 2:05 Snow 110 0 7 2:15 Maximum ETE: 3:40 Average ETE: 2:45 Table 8-18. Homebound Special Needs Persons Evacuation Time Estimates - Second Wave for Wheelchair Bound People Wolf Creek Generating Station 8-29 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
9 TRAFFIC MANAGEMENT STRATEGY This section discusses the suggested traffic control and management strategy that is designed to expedite the movement of evacuating traffic. The resources required to implement this strategy include:
" Personnel with the capabilities of performing the planned control functions of traffic guides (preferably, not necessarily, law enforcement officers).
" Traffic Control Devices to assist these personnel in the performance of their tasks. These devices should comply with the guidance of the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration (FHWA) of the U.S.D.O.T. All state and most county transportation agencies have access to the MUTCD, which is available on-line: http://mutcd.fhwa.dot.gov which provides access to the official PDF version.
" A plan that defines all locations, provides necessary details and is documented in a format that is readily understood by those assigned to perform traffic control.
The functions to be performed in the field are:
- 1. Facilitate evacuating traffic movements that safely expedite travel out of the EPZ.
- 2. Discourage traffic movements that move evacuating vehicles in a direction which takes them significantly closer to the power plant, or which interferes with the efficient flow of other evacuees.
We employ the terms "facilitate" and "discourage" rather than "enforce" and "prohibit" to indicate the need for flexibility in performing the traffic control function. There are always legitimate reasons for a driver to prefer a direction other than that indicated. For example:
- A driver may be traveling home from work or from another location, to join other family members prior to evacuating.
- An evacuating driver may be travelling to pick up a relative, or other evacuees.
- The driver may be an emergency worker en route to perform an important activity.
The implementation of a plan must also be flexible enough for the application of sound judgment by the traffic guide.
The traffic management plan is the outcome of the following process:
- 1. The existing TCPs and ACPs identified by the offsite agencies in their existing emergency plans serve as the basis of the traffic management plan, as per NUREG/CR-7002.
- 3. Computer analysis of the evacuation traffic flow environment (see Figures 7-3 through 7-5). As discussed in Section 7.3, congestion within the EPZ is clear by 1 Hour after the ATE. The only intersection that experiences LOS F is Housatonic St and US-75 in Burlington. Based on the limited traffic congestion within the EPZ, no additional TCPs or Wolf Creek Generating Station 9-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
ACPs are identified-as a result of this study. The existing traffic management plans are adequate.
The ETE analysis treated all controlled intersections that are existing TCP locations in the offsite agency plans as being controlled by actuated signals.
The ETE calculations reflect the assumption that all "external-external" trips are interdicted and diverted after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> have elapsed from the ATE.
All transit vehicles and other responders entering the EPZ to support the evacuation are assumed to be unhindered by personnel manning ACPs and TCPs.
Study Assumptions 5 and 6 in Section 2.3 discuss ACP and TCP staffing schedules and operations.
Wolf Creek Generating Station 9-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
10 EVACUATION ROUTES Evacuation routes are comprised of two distinct components:
- Routing from a subzone being evacuated to the boundary of the Evacuation Region and thence out of the EPZ.
- Routing of transit-dependent evacuees from the EPZ boundary to the reception and care center.
Evacuees will select routes within the EPZ in such a way as to minimize their exposure to risk.
This expectation is met by the DYNEV II model routing traffic away from the location of the plant, to the extent practicable. The DTRAD model satisfies this behavior by routing traffic so as to balance traffic demand relative to the available highway capacity to the extent possible.
See Appendices B through D for further discussion.
The routing of transit-dependent evacuees from the EPZ boundary to the reception and care center is designed to minimize the amount of travel outside the EPZ, from the points where these routes cross the EPZ boundary.
Figure 10-1 maps the reception and care center for evacuees. The major evacuation routes for the EPZ are presented in Figure 10-2.
It is assumed that all school evacuees will be taken to the reception and care center and subsequently be picked up by parents or guardians. Transit-dependent evacuees are also transported to the reception and care center. This study does not consider the transport of evacuees from the reception and care center to congregate care centers, if the county does make the decision to relocate evacuees.
Wolf Creek Generating Station 10-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Figure 10-1. WCGS Reception and Care Center Wolf Creek Generating Station 10-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. I
Figure 10-2. Evacuation Route Map Wolf Creek Generating Station 10-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
APPENDIX A Glossary of Traffic Engineering Terms
A. GLOSSARY OF TRAFFIC ENGINEERING TERMS Table A-i. Glossary of Traffic Engineering Terms Ter- Deiito Analysis Network A graphical representation of the geometric topology of a physical roadway system, which is comprised of directional links and nodes.
Link A network link represents a specific, one-directional section of roadway. A link has both physical (length, number of lanes, topology, etc.) and operational (turn movement percentages, service rate, free-flow speed) characteristics.
Measures of Effectiveness Statistics describing traffic operations on a roadway network.
Node A network node generally represents an intersection of network links. A node has control characteristics, i.e., the allocation of service time to each approach link.
Origin A location attached to a network link, within the EPZ or Shadow Region, where trips are generated at a specified rate in vehicles per hour (vph). These trips enter the roadway system to travel to their respective destinations.
Prevailing Roadway and Relates to the physical features of the roadway, the nature (e.g.,
Traffic Conditions composition) of traffic on the roadway and the ambient conditions (weather, visibility, pavement conditions, etc.).
Service Rate Maximum rate at which vehicles, executing a specific turn maneuver, can be discharged from a section of roadway at the prevailing conditions, expressed in vehicles per second (vps) or vehicles per hour (vph).
Service Volume Maximum number of vehicles which can pass over a section of roadway in one direction during a specified time period with operating conditions at a specified Level of Service (The Service Volume at the upper bound of Level of Service, E, equals Capacity).
Service Volume is usually expressed as vehicles per hour (vph).
Signal Cycle Length The total elapsed time to display all signal indications, in sequence.
The cycle length is expressed in seconds.
Signal Interval A single combination of signal indications. The interval duration is expressed in seconds. A signal phase is comprised of a sequence of signal intervals, usually green, yellow, red.
Wolf Creek Generating Station A-i A-1 KLD Engineering, P.C.
KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Defiitio I Ter Signal Phase A set of signal indications (and intervals) which services a particular combination of traffic movements on selected approaches to the intersection. The phase duration is expressed in seconds.
Traffic (Trip) Assignment A process of assigning traffic to paths of travel in such a way as to satisfy all trip objectives (i.e., the desire of each vehicle to travel from a specified origin in the network to a specified destination) and to optimize some stated objective or combination of objectives. In general, the objective is stated in terms of minimizing a generalized "cost". For example, "cost" may be expressed in terms of travel time.
Traffic Density The number of vehicles that occupy one lane of a roadway section of specified length at a point in time, expressed as vehicles per mile (vpm).
Traffic (Trip) Distribution A process for determining the destinations of all traffic generated at the origins. The result often takes the form of a Trip Table, which is a matrix of origin-destination traffic volumes.
Traffic Simulation A computer model designed to replicate the real-world operation of vehicles on a roadway network, so as to provide statistics describing traffic performance. These statistics are called Measures of Effectiveness.
Traffic Volume The number of vehicles that pass over a section of roadway in one direction, expressed in vehicles per hour (vph). Where applicable, traffic volume may be stratified by turn movement.
Travel Mode Distinguishes between private auto, bus, rail, pedestrian and air travel modes.
Trip Table or Origin- A rectangular matrix or table, whose entries contain the number Destination Matrix of trips generated at each specified origin, during a specified time period, that are attracted to (and travel toward) each of its specified destinations. These values are expressed in vehicles per hour (vph) or in vehicles.
Turning Capacity The capacity associated with that component of the traffic stream which executes a specified turn maneuver from an approach at an intersection.
Wolf Creek Generating Station A-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
APPENDIX B DTRAD: Dynamic Traffic Assignment and Distribution Model
B. DYNAMIC TRAFFIC ASSIGNMENT AND DISTRIBUTION MODEL This section describes the integrated dynamic trip assignment and distribution model named DTRAD (Dynamic Traffic Assignment and Distribution) that is expressly designed for use in analyzing evacuation scenarios. DTRAD employs logit-based path-choice principles and is one of the models of the DYNEVII System. The DTRAD module implements path-based Dynamic Traffic Assignment (DTA) so that time dependent Origin-Destination (OD) trips are "assigned" to routes over the network based on prevailing traffic conditions.
To apply the DYNEV II System, the analyst must specify the highway network, link capacity information, the time-varying volume of traffic generated at all origin centroids and, optionally, a set of accessible candidate destination nodes on the periphery of the EPZ for selected origins.
DTRAD calculates the optimal dynamic trip distribution (i.e., trip destinations) and the optimal dynamic trip assignment (i.e., trip routing) of the traffic generated at each origin node traveling to its set of candidate destination nodes, so as to minimize evacuee travel "cost".
Overview of Integrated Distribution and Assignment Model The underlying premise is that the selection of destinations and routes is intrinsically coupled in an evacuation scenario. That is, people in vehicles seek to travel out of an area of potential risk as rapidly as possible by selecting the "best" routes. The model is designed to identify these "best" routes in a manner that realistically distributes vehicles from origins to destinations and routes them over the highway network, in a consistent and optimal manner, reflecting evacuee behavior.
For each origin, a set of "candidate destination nodes" is selected by the software logic and by the analyst to reflect the desire by evacuees to travel away from the power plant and to access major highways. The specific destination nodes within this set that are selected by travelers and the selection of the connecting paths of travel, are both determined by DTRAD. This determination is made by a logit-based path choice model in DTRAD, so as to minimize the trip "cost", as discussed later.
The traffic loading on the network and the consequent operational traffic environment of the network (density, speed, throughput on each link) vary over time as the evacuation takes place.
The DTRAD model, which is interfaced with the DYNEV simulation model, executes a succession of "sessions" wherein it computes the optimal routing and selection of destination nodes for the conditions that exist at that time.
Interfacing the DYNEV Simulation Model with DTRAD The DYNEV II system reflects NRC guidance that evacuees will seek to travel in a general direction away from the location of the hazardous event. An algorithm was developed to support the DTRAD model in dynamically varying the Trip Table (O-D matrix) over time from one DTRAD session to the next. Another algorithm executes a "mapping" from the specified "geometric" network (link-node analysis network) that represents the physical highway system, to a "path" network that represents the vehicle [turn] movements. DTRAD computations are performed on the "path" network: DYNEV simulation model, on the "geometric" network.
Wolf Creek Generating Station B-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
DTRAD Description DTRAD is the DTA module for the DYNEV II System.
When the road network under study is large, multiple routing options are usually available between trip origins and destinations. The problem of loading traffic demands and propagating them over the network links is called Network Loading and is addressed by DYNEVII using macroscopic traffic simulation modeling. Traffic assignment deals with computing the distribution of the traffic over the road network for given O-D demands and is a model of the route choice of the drivers. Travel demand changes significantly over time, and the road network may have time dependent characteristics, e.g., time-varying signal timing or reduced road capacity because of lane closure, or traffic congestion. To consider these time dependencies, DTA procedures are required.
The DTRAD DTA module represents the dynamic route choice behavior of drivers, using the specification of dynamic origin-destination matrices as flow input. Drivers choose their routes through the network based on the travel cost they experience (as determined by the simulation model). This allows traffic to be distributed over the network according to the time-dependent conditions. The modeling principles of D-TRAD include:
- It is assumed that drivers not only select the best route (i.e., lowest cost path) but some also select less attractive routes. The algorithm implemented by DTRAD archives several "efficient" routes for each O-D pair from which the drivers choose.
- The choice of one route out of a set of possible routes is an outcome of "discrete choice modeling". Given a set of routes and their generalized costs, the percentages of drivers that choose each route is computed. The most prevalent model for discrete choice modeling is the logit model. DTRAD uses a variant of Path-Size-Logit model (PSL). PSL overcomes the drawback of the traditional multinomial logit model by incorporating an additional deterministic path size correction term to address path overlapping in the random utility expression.
" DTRAD executes the TA algorithm on an abstract network representation called "the path network" which is built from the actual physical link-node analysis network. This execution continues until a stable situation is reached: the volumes and travel times on the edges of the path network do not change significantly from one iteration to the next. The criteria for this convergence are defined by the user.
- Travel "cost" plays a crucial role in route choice. In DTRAD, path cost is a linear summation of the generalized cost of each link that comprises the path. The generalized cost for a link, a, is expressed as c, = at, + /l + yso, where c, is the generalized cost for link a, and a,g8, and yare cost coefficients for link travel time, distance, and supplemental cost, respectively. Distance and supplemental costs are defined as invariant properties of the network model, while travel time is a dynamic property dictated by prevailing traffic conditions. The DYNEV simulation model Wolf Creek Generating Station B-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
computes travel times on all edges in the network and DTRAD uses that information to constantly update the costs of paths. The route choice decision model in the next simulation iteration uses these updated values to adjust the route choice behavior. This way, traffic demands are dynamically re-assigned based on time dependent conditions.
The interaction between the DTRAD traffic assignment and DYNEV II simulation models is depicted in Figure B-1. Each round of interaction is called a Traffic Assignment Session (TA session). A TA session is composed of multiple iterations, marked as loop B in the figure.
The supplemental cost is based on the "survival distribution" (a variation of the exponential distribution).The Inverse Survival Function is a "cost" term in DTRAD to represent the potential risk of travel toward the plant:
Sa =- 13In (p), 0< p <1; 13>0 d,
do dn= Distance of node, n, from the plant do =Distance from the plant where there is zero risk 13= Scaling factor The value of do = 15 miles, the outer distance of the shadow region. Note that the supplemental cost, Sa, of link, a, is (high, low), if its downstream node, n, is (near, far from) the power plant.
creek Generating wolf Creek Station Generating Station KLD Engineering, Rc.
Wolf B-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Network Equilibrium In 1952, John Wardrop wrote:
Under equilibrium conditions traffic arrangesitself in congested networks in such a way that no individual trip-maker can reduce his path costs by switching routes.
The above statement describes the "User Equilibrium" definition, also called the "Selfish Driver Equilibrium". It is a hypothesis that represents a [hopeful] condition that evolves over time as drivers search out alternative routes to identify those routes that minimize their respective "costs". It has been found that this "equilibrium" objective to minimize costs is largely realized by most drivers who routinely take the same trip over the same network at the same time (i.e.,
commuters). Effectively, such drivers "learn" which routes are best for them over time. Thus, the traffic environment "settles down" to a near-equilibrium state.
Clearly, since an emergency evacuation is a sudden, unique event, it does not constitute a long-term learning experience which can achieve an equilibrium state. Consequently, DTRAD was not designed as an equilibrium solution, but to represent drivers in a new and unfamiliar situation, who respond in a flexible manner to real-time information (either broadcast or observed) in such a way as to minimize their respective costs of travel.
Station Generating Station creek Generating Wolf Creek KLD Engineering, p.c.
Wolf B-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Start of next DTRAD Session 0
Set To = Clock time.
Archive System State at To I
DefinePercentages latest Link Turn Execute Simulation Model from B time, To to T1 (burn time)
Provide DTRAD with link MOE at ]
time, T1 I
Execute DTRAD iteration; Get new Turn Percentages
[ Retrieve System State at To; Apply new Link Turn Percents DTRAD iteration converges?
No Yes Next iteration Simulate from To to T2 (DTA session duration)
Set Clock to Te Figure B-1. Flow Diagram of Simulation-DTRAD Interface Wolf Creek Generating Station B-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
APPENDIX C DYNEV Traffic Simulation Model
C. DYNEV TRAFFIC SIMULATION MODEL The DYNEV traffic simulation model is a macroscopic model that describes the operations of traffic flow in terms of aggregate variables: vehicles, flow rate, mean speed, volume, density, queue length, on each link, for each turn movement, during each Time Interval (simulation time step). The model generates trips from "sources" and from Entry Links and introduces them onto the analysis network at rates specified by the analyst based on the mobilization time distributions. The model simulates the movements of all vehicles on all network links over time until the network is empty. At intervals, the model outputs Measures of Effectiveness (MOE) such as those listed in Table C-1.
Model Features Include:
" Explicit consideration is taken of the variation in density over the time step; an iterative procedure is employed to calculate an average density over the simulation time step for the purpose of computing a mean speed for moving vehicles.
" Multiple turn movements can be serviced on one link; a separate algorithm is used to estimate the number of (fractional) lanes assigned to the vehicles performing each turn movement, based, in part, on the turn percentages provided by the DTRAD model.
" At any point in time, traffic flow on a link is subdivided into two classifications: queued and moving vehicles. The number of vehicles in each classification is computed. Vehicle spillback, stratified by turn movement for each network link, is explicitly considered and quantified. The propagation of stopping waves from link to link is computed within each time step of the simulation. There is no "vertical stacking" of queues on a link.
" Any link can accommodate "source flow" from zones via side streets and parking facilities that are not explicitly represented. This flow represents the evacuating trips that are generated at the source.
" The relation between the number of vehicles occupying the link and its storage capacity is monitored every time step for every link and for every turn movement. If the available storage capacity on a link is exceeded by the demand for service, then the simulator applies a "metering" rate to the entering traffic from both the upstream feeders and source node to ensure that the available storage capacity is not exceeded.
" A "path network" that represents the specified traffic movements from each network link is constructed by the model; this path network is utilized by the DTRAD model.
- A two-way interface with DTRAD: (1) provides link travel times; (2) receives data that translates into link turn percentages.
- Provides MOE to animation software, EVAN
" Calculates ETE statistics Wolf Creek Generating Station C-1 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
All traffic simulation models are data-intensive. Table C-2 outlines the necessary input data elements.
To provide an efficient framework for defining these specifications, the physical highway environment is represented as a network. The unidirectional links of the network represent roadway sections: rural, multi-lane, urban streets or freeways. The nodes of the network generally represent intersections or points along a section where a geometric property changes (e.g. a lane drop, change in grade or free flow speed).
Figure C-1 is an example of a small network representation. The freeway is defined by the sequence of links, (20,21), (21,22), and (22,23). Links (8001, 19) and (3, 8011) are Entry and Exit links, respectively. An arterial extends from node 3 to node 19 and is partially subsumed within a grid network. Note that links (21,22) and (17,19) are grade-separated.
Table C-1. Selected Measures of Effectiveness Output by DYNEV II Mesr Vehicles Unt ppisT Vehicles Discharged Link, Network, Exit Link Speed Miles/Hours (mph) Link, Network Density Vehicles/Mile/Lane Link Level of Service LOS Link Content Vehicles Network Travel Time Vehicle-hours Network Evacuated Vehicles Vehicles Network, Exit Link Trip Travel Time Vehicle-minutes/trip Network Capacity Utilization Percent Exit Link Attraction Percent of total evacuating vehicles Exit Link Max Queue Vehicles Node, Approach Time of Max Queue Hours:minutes Node, Approach Route Statistics Length (mi); Mean Speed (mph); Travel Route Time (min)
Mean Travel Time Minutes Evacuation Trips; Network Wolf Creek Generating Station C-2 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table C-2. Input Requirements for the DYNEV II Model HIGHWAY NETWORK
- Links defined by upstream and downstream node numbers
- Link lengths
- Number of lanes (up to 9) and channelization
- Turn bays (1 to 3 lanes)
- Destination (exit) nodes
" Network topology defined in terms of downstream nodes for each receiving link
- Node Coordinates (X,Y)
- Nuclear Power Plant Coordinates (X,Y)
GENERATED TRAFFIC VOLUMES
- On all entry links and source nodes (origins), by Time Period TRAFFIC CONTROL SPECIFICATIONS
- Traffic signals: link-specific, turn movement specific
- Signal control treated as fixed time or actuated
- Location of traffic control points (these are represented as actuated signals)
- Stop and Yield signs
- Right-turn-on-red (RTOR)
- Route diversion specifications
- Turn restrictions
" Lane control (e.g. lane closure, movement-specific)
DRIVER'S AND OPERATIONAL CHARACTERISTICS
- Driver's (vehicle-specific) response mechanisms: free-flow speed, discharge headway
- Bus route designation.
DYNAMIC TRAFFIC ASSIGNMENT
" Candidate destination nodes for each origin (optional)
- Duration of DTA sessions
- Duration of simulation "burn time"
" Desired number of destination nodes per origin INCIDENTS
- Identify and Schedule of closed lanes
- Identify and Schedule of closed links Wolf Creek Generating Station C-3 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Entry, Exit Nodes are numbered 8xxx Figure C-1. Representative Analysis Network Wolf Creek Generating Station C-4 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
C.1 Methodology C.1.1 The Fundamental Diagram It is necessary to define the fundamental diagram describing flow-density and speed-density relationships. Rather than "settling for" a triangular representation, a more realistic representation that includes a "capacity drop", (I-R)Qnmax, at the critical density when flow conditions enter the forced flow regime, is developed and calibrated for each link. This representation, shown in Figure C-2, asserts a constant free speed up to a density, kf, and then a linear reduction in speed in the range, kf _*k _*k, = 45 vpm, the density at capacity. In the flow-density plane, a quadratic relationship is prescribed in the range, kc < k __k, = 95 vpm which roughly represents the "stop-and-go" condition of severe congestion. The value of flow rate, Qs, corresponding to ks, is approximated at 0.7 RQmax. A linear relationship between k, and kj completes the diagram shown in Figure C-2. Table C-3 is a glossary of terms.
The fundamental diagram is applied to moving traffic on every link. The specified calibration values for each link are: (1) Free speed, vf ; (2) Capacity, Qmax ; (3) Critical density, kc =
45 vpm ; (4) Capacity Drop Factor, R = 0.9 ; (5) Jam density, k1 . Then, vc = Qmax kf = kc-(Vc-Vc) k. Setting k=k-kc, 2 thenQ=RQmax RQmax k for 0<k<ks=5 0 It can be Qmax 8333 shown that Q = (0.98 - 0.0056 k) RQmax for ks !5; k !5 kj, where k, = 50 and k = 175.
C.1.2 The Simulation Model The simulation model solves a sequence of "unit problems". Each unit problem computes the movement of traffic on a link, for each specified turn movement, over a specified time interval (TI) which serves as the simulation time step for all links. Figure C-3 is a representation of the unit problem in the time-distance plane. Table C-3 is a glossary of terms that are referenced in the following description of the unit problem procedure.
Wolf Creek Generating Station C-5 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Volume, vph Capacity Drop Qmax R Qmax
--- Qs Density, vpm SlowKegimes mph Free Forced' A
- -i Iii Ii Iii Vf Iii I ii R vc I I II II II II
-- Density, vpm kf k,I Figure C-2. Fundamental Diagrams Wolf Creek Generating Station C-6 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Distance OQ OM OE O Down Qb Qe L
Mb Me Up El E2 -po-.... I n eI TI Figure C-3. A UNIT Problem Configuration with tj > 0 Wolf Creek Generating Station C-7 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Table C-3. Glossary The maximum number of vehicles, of a particular movement, that can discharge Cap from a link within a time interval.
the E The number of vehicles, of a particular movement, that enter the link over time interval. The portion, ETI, can reach the stop-bar within the TI.
The green time: cycle time ratio that services the vehicles of a particular turn movement on a link.
h The mean queue discharge headway, seconds.
k Density in vehicles per lane per mile.
The average density of moving vehicles of a particular movement over a TI, on a link.
L The length of the link in feet.
The queue length in feet of a particular movement, at the [beginning, end] of a Lb Le
, time interval.
The number of lanes, expressed as a floating point number, allocated to service a particular movement on a link.
L, The mean effective length of a queued vehicle including the vehicle spacing, feet.
M Metering factor (Multiplier): 1.
The number of moving vehicles on the link, of a particular movement, that are Mb, Me moving at the [beginning, end] of the time interval. These vehicles are assumed to be of equal spacing, over the length of link upstream of the queue.
The total number of vehicles of a particular movement that are discharged from a link over a time interval.
The components of the vehicles of a particular movement that are discharged the beginning of OQ, OM ,OE from a link within a time interval: vehicles that were Queued at the TI; vehicles that were Moving within the link at the beginning of the TI; vehicles that Entered the link during the TI.
The percentage, expressed as a fraction, of the total flow on the link that executes a particular turn movement, x.
Wolf Creek Generating Station C-8 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
The number of queued vehicles on the link, of a particular turn movement, at the
,Qe [beginning, end] of the time interval.
The maximum flow rate that can be serviced by a link for a particular movement Qmax in the absence of a control device. It is specified by the analyst as an estimate of link capacity, based upon a field survey, with reference to the HCM.
R The factor that is applied to the capacity of a link to represent the "capacity drop" when the flow condition moves into the forced flow regime. The lower capacity at that point is equal to RQmax.
RCap The remaining capacity available to service vehicles of a particular movement after that queue has been completely serviced, within a time interval, expressed as vehicles.
S" Service rate for movement x, vehicles per hour (vph).
tj Vehicles of a particular turn movement that enter a link over the first t1 seconds of a time interval, can reach the stop-bar (in the absence of a queue down-stream) within the same time interval.
TI The time interval, in seconds, which is used as the simulation time step.
v The mean speed of travel, in feet per second (fps) or miles per hour (mph), of moving vehicles on the link.
VQ The mean speed of the last vehicle in a queue that discharges from the link within the TI. This speed differs from the mean speed of moving vehicles, v.
W The width of the intersection in feet. This is the difference between the link length which extends from stop-bar to stop-bar and the block length.
KLD Engineering, p.c.
Wolf Creek Generating Station c-9 C-9 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
The formulation and the associated logic presented below are designed to solve the unit problem for each sweep over the network (discussed below), for each turn movement serviced on each link that comprises the evacuation network, and for each TI over the duration of the evacuation.
Given= Qb, Mb, L, TI, Eo, LN, G/C , h, Lv, RO, Lc, E,M Compute = 0, Qe, Me Define O=OQ+OM+OE ; E=E1 +E 2
- 1. For the first sweep, s = 1, of this TI, get initial estimates of mean density, ko , the R - factor, R0 and entering traffic, E0 , using the values computed for the final sweep of the prior TI.
For each subsequent sweep, s > 1 , calculate E = Zi Pi Oi + S where Pi , Oi are the relevant turn percentages from feeder link, i , and its total outflow (possibly metered) over this TI; S is the total source flow (possibly metered) during the current TI.
Set iteration counter, n = 0, k = k0 ,and E = E0 .
- 2. Calculate v (k) such that k 130 using the analytical representations of the fundamental diagram.
Calculate Cap = Qmax(TI) (G/C) LN;,in vehicles, this value may be reduced 3600 C due to metering SetR= 1.0ifG/c< 1 orifk<kc; Set R=0.9onlyifG/C= land k>kc Calculate queue length, Lb = Qbv LL
- 3. Calculate tj = TI--L Iftl-<0, settT El OE=O; Else, El =EL
- 4. Then E 2 =E-E 1 ; t2 =TI-tj
- 5. If Qb > Cap, then OQ =Cap,OM = OE= 0 If tj > 0,then Qe = Qb + Mb + E1 - Cap Else Q'e = Qb - Cap End if Calculate Qe and Me using Algorithm A (below)
- 6. Else (Qb < Cap)
OQ = Qb, RCap = Cap- OQ Wolf Creek Generating Station C-10 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
- 7. If Mb !5 RCapthen
- 8. If t1 > 0, OM = Mb OE = min (RCap - Mb, TIaP) - 0 Qe = El - OE If Qe > 0,then Calculate Qe, Me with Algorithm A Else Qe 0, Me = E2 End if Else (t, = 0)
OM= (V(TI)-Lb) Mb and OE = 0 M L-Lb +
Me =Mb -- OM + E ; Qe = 0 End if
- 9. Else (Mb > RCap)
OE= 0 If tl > 0, then Om= RCap, Qe = Mb - OM + E1 Calculate Qe and Me using Algorithm A
- 10. Else (t, = 0)
Md [v(TI)-Lb) Mb]
If Md > RCap, then Om= RCap Qe= Md - OM Apply Algorithm A to calculate Qe and Me Else OM = Md Me = Mb - 0M + E and Qe = 0 End if End if End if End if
- 11. Calculate a new estimate of average density, kn = [kb + 2 km + ke],
where kb = density at the beginning of the TI ke = density at the end of the TI km = density at the mid-point of the TI All values of density apply only to the moving vehicles.
If Ikn - kn-1i > E and n < N Wolf Creek Generating Station c-il C-11 KLLJ Engineering, P.L.
KLD Engineering, P.C.
Evacuation Time Estimate Rev. I
where N = max number of iterations, and E is a convergence criterion, then
- 12. set n = n + 1 , and return to step 2 to perform iteration, n, using k = kn*
End if Computation of unit problem is now complete. Check for excessive inflow causing spillback.
13.lIf Qe +Me >(-)___Nte
>(L(LW) LN the The number of excess vehicles that cause spillback is: SB = Qe + Me (LW).LN where W is the width of the upstream intersection. To prevent spillback, meter the outflow from the feeder approaches and from the source flow, S, during this TI by the amount, SB. That is, set SB M= 1 - S) - 0,where M is the metering factor (over all movements).
(E +S)-
This metering factor is assigned appropriately to all feeder links and to the source flow, to be applied during the next network sweep, discussed later.
Algorithm A This analysis addresses the flow environment over a TI during which moving vehicles can join a standing or discharging queue. For the case Qb VQe shown, Qb -- Cap, with t, > 0 and a queue of Qe length, Qe, formed by that portion of Mb and E that reaches the stop-bar within the TI, but could v not discharge due to inadequate capacity. That is, Mb Qb + Mb+- 1 > Cap. This queue length, v L3 Qe = Qb + Mb + El - Cap can be extended to Qe by traffic entering the approach during the current IF TI, traveling at speed, v, and reaching the rear of the tiW t3 queue within the TI. A portion of the entering TI vehicles, E3 = E T, will likely join the queue. This analysis calculates t 3 , Qe and Me for the input values of L, TI, v, E, t, Lv, LN, Qe When t 1 > 0 and Qb -* Cap:
Lv Lv
- Define: Le = Q'e LN - . From the sketch, L3 = v(TI - t 1 - t 3 )= L - (Qe+ E3)
LN Substituting E3 =--t- E yields: - vt 3 + E = L - v(TI - t 1 ) - Le . Recognizing that TI TI LN Wolf Creek Generating Station C-12 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
the first two terms on the right hand side cancel, solve for t 3 to obtain:
t3
[4 E Lv such that 0__ t 3 _<TI-tj
[v TI L-NI If the denominator, [v - TL;-]
- 0, set t3 = TI - t1 Then,Q, = Q'e+E TI Me = E (1 tI +t 3)
The complete Algorithm A considers all flow scenarios; space limitation precludes its inclusion, here.
C.1.3 Lane Assignment The "unit problem" is solved for each turn movement on each link. Therefore it is necessary to calculate a value, LNx, of allocated lanes for each movement, x. If in fact all lanes are specified by, say, arrows painted on the pavement, either as full lanes or as lanes within a turn bay, then the problem is fully defined. If however there remain un-channelized lanes on a link, then an analysis is undertaken to subdivide the number of these physical lanes into turn movement specific virtual lanes, LN,.
C.2 Implementation C.2.1 Computational Procedure The computational procedure for this model is shown in the form of a flow diagram as Figure C-4. As discussed earlier, the simulation model processes traffic flow for each link independently over TI that the analyst specifies; it is usually 60 seconds or longer. The first step is to execute an algorithm to define the sequence in which the network links are processed so that as many links as possible are processed after their feeder links are processed, within the same network sweep. Since a general network will have many closed loops, it is not possible to guarantee that every link processed will have all of its feeder links processed earlier.
The processing then continues as a succession of time steps of duration, TI, until the simulation is completed. Within each time step, the processing performs a series of "sweeps" over all network links; this is necessary to ensure that the traffic flow is synchronous over the entire network. Specifically, the sweep ensures continuity of flow among all the network links; in the context of this model, this means that the values of E, M, and S are all defined for each link such that they represent the synchronous movement of traffic from each link to all of its outbound links. These sweeps also serve to compute the metering rates that control spillback.
Wolf Creek Generating Station C-13 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
Within each sweep, processing solves the "unit problem" for each turn movement on each link.
With the turn movement percentages for each link provided by the DTRAD model, an algorithm allocates the number of lanes to each movement serviced on each link. The timing at a signal, if any, applied at the downstream end of the link, is expressed as a G/C ratio, the signal timing needed to define this ratio is an input requirement for the model. The model also has the capability of representing, with macroscopic fidelity, the actions of actuated signals responding to the time-varying competing demands on the approaches to the intersection.
The solution of the unit problem yields the values of the number of vehicles, 0, that discharge from the link over the time interval and the number of vehicles that remain on the link at the end of the time interval as stratified by queued and moving vehicles: Qe and Me. The procedure considers each movement separately (multi-piping). After all network links are processed for a given network sweep, the updated consistent values of entering flows, E; metering rates, M; and source flows, S are defined so as to satisfy the "no spillback" condition.
The procedure then performs the unit problem solutions for all network links during the following sweep.
Experience has shown that the system converges (i.e. the values of E, M and S "settle down" for all network links) in just two sweeps if the network is entirely under-saturated or in four sweeps in the presence of extensive congestion with link spillback. (The initial sweep over each link uses the final values of E and M, of the prior TI). At the completion of the final sweep for a TI, the procedure computes and stores all measures of effectiveness for each link and turn movement for output purposes. It then prepares for the following time interval by defining the values of Qb and Mb for the start of the next TI as being those values of Qe and Me at the end of the prior TI. In this manner, the simulation model processes the traffic flow over time until the end of the run. Note that there is no space-discretization other than the specification of network links.
Wolf Creek Generating Station c-14 KLD Engineering. P.C.
Evacuation Time Estimate Rev. 1
Figure C-4. Flow of Simulation Processing (See Glossary: Table C-3)
Wolf Creek Generating Station C-15 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1
C.2.2 Interfacing with Dynamic Traffic Assignment (DTRAD)
The DYNEV II system reflects NRC guidance that evacuees will seek to travel in a general direction away from the location of the hazardous event. Thus, an algorithm was developed to identify an appropriate set of destination nodes for each origin based on its location and on the expected direction of travel. This algorithm also supports the DTRAD model in dynamically varying the Trip Table (O-D matrix) over time from one DTRAD session to the next.
Figure B-1 depicts the interaction of the simulation model with the DTRAD model in the DYNEV II system. As indicated, DYNEV II performs a succession of DTRAD "sessions"; each such session computes the turn link percentages for each link that remain constant for the session duration,
[To , T2 ], specified by the analyst. The end product is the assignment of traffic volumes from each origin to paths connecting it with its destinations in such a way as to minimize the network-wide cost function. The output of the DTRAD model is a set of updated link turn percentages which represent this assignment of traffic.
As indicated in Figure B-i, the simulation model supports the DTRAD session by providing it with operational link MOE that are needed by the path choice model and included in the DTRAD cost function. These MOE represent the operational state of the network at a time, Ti _<T2, which lies within the session duration, [To ,T 2]. This "burn time", T1 - To, is selected by the analyst. For each DTRAD iteration, the simulation model computes the change in network operations over this burn time using the latest set of link turn percentages computed by the DTRAD model. Upon convergence of the DTRAD iterative procedure, the simulation model accepts the latest turn percentages provided by the DTA model, returns to the origin time, To , and executes until it arrives at the end of the DTRAD session duration at time, T2 . At this time the next DTA session is launched and the whole process repeats until the end of the DYNEV II run.
Additional details are presented in Appendix B.
Wolf Creek Generating Station C-16 KLD Engineering, P.C.
Evacuation Time Estimate Rev. 1