{{#Wiki_filter:ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, -15.00 ft, CAL-AB-119 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchoracqe
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? Yes
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Anchorage is consistent with drawing FSK-C-0078.
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Yes Interaction Effects C-435
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes Observed that the pump's sight glass cage is missing, not a seismic interaction concern.
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-436
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1PUMPSICS11 8-6-12 200 I FumliblUbi I 5-b-lz ZU1 C-437
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1PUMPSICS11 8-6-12 203 1PUMPSICS11 8-6-12 202 C-438
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1 1PUMPSICS11 8-6-12 204 I ljumvblL;bl I t5--j-1 z ZU0 C-439
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1PUMPSICS11 8-6-12 207 1PUMPSICS11 8-6-12 206 C-440
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: MI N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1PUMPSICS11 8-6-12 208 I111l,* ~ 1 WI I '." I I I[ 1PUMPSICS11 8-6-12 211 1PUMPSICS11 8-6-12 212 C-441
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 CONTAINMENT SPRAY PUMP 1 PUMPSICS1 1 8-6-12 213 1PUMPSICS11 8-6-12 215 1PUMPSICS11 8-6-12 216 C-442
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 CONTAINMENT SPRAY PUMP Project: CCNPP I SWEL Location (Bldg, Elev, Room/Area): AUX, -15.00ft, CAL-AB-118 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? No Yes Yes Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Interaction Effects C-443
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 CONTAINMENT SPRAY PUMP
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes Drain line supported near pump at floor, judged not a seismic concern..
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-444
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: V N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSICS12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 CONTAINMENT SPRAY PUMP WFUMvbSIA512 U-1-12 236 1PUMPSICS12 8-7-12 237 1PUMPSICS12 8-7-12 238 1PUMPSICS12 8-7-12 239 C-445
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: Equipment
Description:
1PUMPSICS12 (5) Horizontal Pumps 12 CONTAINMENT SPRAY PUMP 1PUMPSICS12 8-7-12 241 1PUMPSICS12 8-7-12 242 1PUMPSICS12 8-7-12 243 C-446
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 HIGH PRESS SAFETY INJ Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, -15.00 ft, CAL-AB-119 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? Yes
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes Yes Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Anchorage is consistent with drawing
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Interaction Effects C-447
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 HIGH PRESS SAFETY INJ
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? A drip catch device hose is resting on a sight glass and the sight glass has no cage. SRTjudged that the hose does not have sufficient mass to break the glass during a seismic event, therefore not a concern. Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-448
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: EauiDment DescriDtion: 1 PUMPSIHPI 1 (5) Horizontal Pumps 11 HIGH PRESS SAFETY INJ 1'I W1II'HIHI-' 1 M-K-1,.1 1 I 1PI IIU'IV.*,IIHI"*"I"I M,,JPi-I'J *"1l'4 1PUMPSIHP11 8-6-12 219 1PUMPSIHP11 8-6-12 220 C-449
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP11 Equipment Class: (5) Horizontal Pumps Equipment
Description:
11 HIGH PRESS SAFETY INJ IFUMIJbINFIll U-b-12222 I 1jUMvb1N1j1 I U-b-1Z Zzi 1I-'UMI-SIH'1 1 U-43-12 224 C-450
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: biment
Description:
1PUMPSIHPI11 (5) Horizontal Pumps 11 HIGH PRESS SAFETY INJ 1PUMPSIHP11 5-6-12 225 1PUMPSIHP11 8-6-12 227 C-451
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 HIGH PRESS SAFETY INJ Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, -15.00 ft, CAL-AB-119 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? No
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Yes Yes Yes
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Interaction Effects C-452
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: F N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 HIGH PRESS SAFETY INJ
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Observed scaffold hardware attached to a beam above the pump, judged the hardware to be adequately attached, therefore not a seismic concern.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-453
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: inmn*nt la=*rrinfinn. 1PUMPSIHP12 (5) Horizontal Pumps 12 HIGH PRESS SAFETY INJ 1PUMPSIHP12 8-6-12 231 1PUMPSIHP12 8-6-12 233 1PUMPSIHP12 8-6-12 232 C-454
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 HIGH PRESS SAFETY INJ 1PUMPSIHP12 8-6-12 234 1PUMPSIHP12 8-6-12 236 1PUMPSIHP12 8-6-12 237 C-455
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: FnninmAnt Drcrintinn-1 PUMPSIHP12 (5) Horizontal Pumps 12 HIGH PRESS SAFETY INJ 1PUMP5IHP12 B-5-12 239 II"UM"*IM"IZ --{*-Iz ZJO* C-456
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Lu-l N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSIHP12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 HIGH PRESS SAFETY INJ 1IUM1'iIIr-I1Z 0i-10-Z Z4U C-457
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSILPSI12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 LOW PRESS SAFETY INJ Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, -15.00 ft, CAL-AB-118 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? No Yes Yes
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Interaction Effects C-458
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSILPSI12 Equipment Class: (5) Horizontal Pumps Equipment
Description:
12 LOW PRESS SAFETY INJ
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes Scaffold is judged as seismically adequate.
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes Small bore piping is supported on a stanchion anchored to the floor near the pump, flexibility judged adequate.
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-459
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: ipment
Description:
1 PUMPSILPS112 (5) Horizontal Pumps 12 LOW PRESS SAFETY INJ 1PUMPSILPSI12 8-7-12 244 1PUMPSILPSI12 8-7-12 245 1PUMPSILPSI12 8-7-12 247 1PUMPSILPSI12 8-7-12 246 C-460
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSILPSI12 Equipment Class: (5) Horizontal Pumps ipment
Description:
12 LOW PRESS SAFETY INJ 1PUMPSILPSI12 8-7-12 248 1PUMPSILPS112 8-7-12 249 P-BE 1PUMPSILPSI12 8-7-12 250 1PUMPSILPSI12 8-7-12 251 C-461
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSILPSI12 Equipment Class: (5) Horizontal Pumps inment Descriotion: 12 LOW PRESS SAFETY INJ IFUMVZ51LV511Z t$-t-12 Zbý3 1PUMPSILPSI12 8-7-12 254 C-462
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSRW13 Equipment Class: (5) Horizontal Pumps Equipment
Description:
13 SERVICE WATER PUMP Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 5.00 ft, CAL-AB-226 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% Yes of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Anchorage is consistent with drawing FSK-0097.
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Yes Yes Yes Yes Interaction Effects C-463
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: E N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSRW13 Equipment Class: (5) Horizontal Pumps Equipment
Description:
13 SERVICE WATER PUMP
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes Lines attached to equipment consist of flex conduit and flexible tubing, both having adequate flexibility, therefore no seismic concern.
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-464
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSRW13 Equipment Class: (5) Horizontal Pumps Equipment
Description:
13 SERVICE WATER PUMP 1PUMPSRW13 8-16-12 071 1PUMPSRW13 8-16-12 074 1PUMPSRWI3 8-16-12 073 C-465
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSRW13 Equipment Class: (5) Horizontal Pumps Equipment
Description:
13 SERVICE WATER PUMP 1PUMPSRW13 8-16-12 076 1PUMPSRW13 8-16-12 077 C-466
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: inmant 1lAqerrinfinn" 1PUMPSRW13 (5) Horizontal Pumps 13 SERVICE WATER PUMP 1PUMPSRW13 8-16-12 080 1PUMPSRW13 8-16-12 079 C-467
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y EW U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW11 Equipment Class: (6) Vertical Pumps Equipment
Description:
11 SALT WATER PUMP Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): Intake, -7.00 ft, CAL-ISPR-INT1 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchoraae
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Anchorage is inaccessible.
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Anchorage is inaccessible.
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Anchorage is inaccessible.
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) No No No Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Anchorage is inaccessible. No Interaction Effects C-468
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: YEE U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW11 Equipment Class: (6) Vertical Pumps Equipment
Description:
11 SALT WATER PUMP
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and No masonry block walls not likely to collapse onto the equipment? A portable flow monitor may fall into pit and damage small bore piping below. CR-2012-009091
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: /*" A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-469
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y E U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW11 Equipment Class: (6) Vertical Pumps &r. M4,4 A 'A I - IAIAr T A Mf I IRiIi 1 WI IIUIIJW-NVI11 1.1K-J 1 HU 1PUMPSW11 8-16-12 190 1PUMPSW11 8-16-12 192 1PUMPSW11 8-16-12 193 C-470
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y ji-U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW12 Equipment Class: (6) Vertical Pumps Equipment
Description:
12 SALT WATER PUMP Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): Intake, -7.00 ft, CAL-ISPR-INT1 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? No
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? No Anchorage is inaccessible.
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? No Anchorage is inaccessible.
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? No Anchorage is inaccessible.
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Anchorage is inaccessible. No Interaction Effects C-471
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y R-- u Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW12 Equipment Class: (6) Vertical Pumps Equipment
Description:
12 SALT WATER PUMP
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and No masonry block walls not likely to collapse onto the equipment? A portable flow monitor may fall into pit and damage small bore piping below. CR-2012-009091
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by:
- 17.
i A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-472
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y iT U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW12 Equipment Class: (6) Vertical Pumps Equipment
Description:
12 SALT WATER PUMP 1FUMFz5vv12 ts-ib-12 196 1PUMPSW12 8-16-12 199 C-473
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y U u Seismic Walkdown Checklist (SWC) Equipment ID No.: 1PUMPSW12 Equipment Class: (6) Vertical Pumps Equipment
Description:
12 SALT WATER PUMP 1PUMPSW12 8-16-12 201 1PUMPSW12 8-16-12 200 C-474
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: I-Y-N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14A Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14A Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-430 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% No of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes Yes Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Interaction Effects C-475
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14A Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14A
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Nearby masonry block wall, identified as SS on drawing A-259, is safety-related and thus seismically rated per IE Bulletin 80-11.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: /7" A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-476
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14A Equipment Class: (4) Transformers I:nainmant fl-rinti~n" A~\\I .%I:P\\I YIPRA: I IAAn1_AA l, IJ-"rITV-I"r#-* 1RY150#151#T14A 8-16-12 114 1RY150#151#T14A 8-16-12 115 C-477
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14A Equipment Class: (4) Transformers Pmnainmjanf FIldarnfinn-A.Qf %\\I _r\\ YPIAIP I I AAAnIAA 1RY150#151#T14A 8-16-12 117 1RY150#151#T14A 8-16-12 116 C-478
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14A Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14A 1RY150#151#T14A 8-16-12 118 I KTIOUN1010 I 14A U-Ib-U I I W C-479
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: F-Y-N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14B Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14B Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-430 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% YE of SWEL items requiring such verification)? es
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) The XFMR is welded to embedded steel by welds that range in length from 6" to 9.5", one weld near each corner. Anchorage is consistent with calculation CA02066 Pg. 27-7 that shows a minimum required weld length of 0. 7" which is smaller than the as-built measurements.
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Yes Yes Yes Yes C-480
ATTACHMENT 3 WALKDOWN CHECKLISTS Status:- N Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14B Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14B Interaction Effects
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Observed a masonry block wall behind the equipment. The wall, identified as SS on drawing A-259, is safety-related and thus seismically rated per IE Bulletin 80-11.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes Lines attached to equipment consist of flex conduit having adequate flexibility, therefore no seismic concern.
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-481
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150/151/T14B Equipment Class: (0) Other nment Descrintion: 480V SERV XFMR U-440-I K Y IMMI b 11; 1 14b U-1 U-1 Z I W IKYIbU;FIbII;I 14tS U-16-12 IU4 C-482
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y W U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14A Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14A Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-430 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? No
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Anchorage is inaccessible.
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Anchorage is inaccessible.
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Anchorage is inaccessible.
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Anchorage is inaccessible. No No No Not Applicable No Interaction Effects C-483
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y W U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14A Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14A
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could No adversely affect the safety functions of the equipment? Cabinet is inaccessible for internal inspection. Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-484
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y K U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14A Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14A 1RY150G#T14A 8-16-12 107 1RY150G#T14A 8-16-12 108 C-485
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y L-I U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14A Equipment Class: (0) Other Eauibment Descdntion: 480V SERV XFMR U-440-14A 1RY150G#T14A 8-16-12 109 1RY150G#T14A 8-16-12 110 C-486
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: YN-U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14A Equipment Class: (0) Other Equipment
Description:
480V SERV XFMR U-440-14A 1RY150G#T14A 8-16-12 111 1RY15UCU#V14A B-16-12 112 1RY150G#T14A 8-16-12 113 C-487
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y W U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14B Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14B Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-430 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchoracqe
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? No
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Anchorage is inaccessible.
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Anchorage is inaccessible.
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Anchorage is inaccessible.
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) No No No Not Applicable
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Anchorage is inaccessible. No Interaction Effects C-488
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y W U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY150G/T14B Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14B
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Observed a masonry block wall behind the equipment. The wall, identified as SS on drawing A-259, is safety-related and thus seismically rated per IE Bulletin 80-11.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could No adversely affect the safety functions of the equipment? Cabinet is inaccessible for internal inspection. Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-489
ATTACHMENT 3 WALKOOWN CHECKLISTS Status: YEE U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: iinmant alQrprinfinn. 1 RY1 50G/T1 4B (4) Transformers 480V SERV XFMR U-440-14B 1RY150G#T14B 8-16-12 093 1RY150G#T14B 8-16-12 094 1RY150G#T14B 8-16-12 096 1RY150G#T14B 8-16-12 095 C-490
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y u Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY15OG/T14B Equipment Class: (4) Transformers Equipment
Description:
480V SERV XFMR U-440-14B I KY I bUUP I 14b t$-Itj-IZ U9t$ 1RY150G#T14B 8-16-12 099 C-491
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y W U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYIY03A/64/B13 Equipment Class: (16) Inverters Equipment
Description:
1Y03 INVERTER Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 27.00 ft, CAL-AB-306 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? Yes
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Yes
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Yes
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Anchorage configuration is consistent with DWG 84195 SHOO02.
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Yes Interaction Effects C-492
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y-N-u Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYlY03A/64/B13 Equipment Class: (16) Inverters Equipment
Description:
1Y03 INVERTER
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes 3/8" gap to I Y03 1/4" gap to 1K02 Evaluated using 8 Hz frequency for cabinets 2% Damping Ratio, 1.5 PF Response Spectrum AB027D2N. dat A=0.25g D= 2 * (1.5*0.25*386) / (8*2*3.14)A2 = 0. 11" < 1/4" OK
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could No adversely affect the safety functions of the equipment? Cabinet is inaccessible for internal inspection. Comments Evaluated by: 7." A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 C-493
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYIYO3A/64/B13 Equipment Class: (16) Inverters Equipment
Description:
1Y03 INVERTER Photos W4 1RYIY03A#64#B13 8-14-12 053 1 RY1Y03A#64#B 13 8-14-12 054 C-494
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y i-U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RY1YO3A/64/B13 Equipment Class: (16) Inverters Pniiinmant rflarinfinn. iVna IIMVI:R*TFP 1RY1Y03A#64#B 13 8-14-12 055 1 RYIY03A#64#B 13 8-14-12 057 1 RY1Y03A#64#B 13 8-14-12 058 C-495
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K1 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K1 RELAY Project: CCNPP I SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-405 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% YR of SWEL items requiring such verification)? Ds
- 2.
Is the anchorage free of bent, broken, missing or loose hardware5.?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors?
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.) Anchorage configuration is consistent with Dwg G 1992 SHOO07 Rev. 9.
- 6.
Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? Yes Yes Yes Yes Yes Interaction Effects C-496
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K1 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K1 RELAY
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Need to determine if drop ceiling is seismically adequate. 10/3/12 - The control room ceiling has been previously evaluated by CCNPP and was determined to not be a credible seismic concem. Masonry block walls, identified as D and E on drawing A-259, are safety-related and thus seismically rated per IE Bulletin 80-11.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: 'V A. Karavoussianis Date: 11/09/2012
- I C. Figliolini 11/09/2012 Photos C-497
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: r N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K1 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K1 RELAY Status: F N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K4 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K4 RELAY Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): AUX, 45.00 ft, CAL-AB-405 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1. Is anchorage configuration verification required (i.e., is the item one of the 50%
No of SWEL items requiring such verification)?
- 2.
Is the anchorage free of bent, broken, missing or loose hardware?
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation?
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Yes Yes Yes
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: This question only applies if the item is one of the 50% for which an anchorage Not Applicable C-498
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K4 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K4 RELAY configuration verification is required.)
- 6.
Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions? Interaction Effects
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment? Need to determine if drop ceiling is seismically adequate. 10/3/12 - The control room ceiling has been previously evaluated by CCNPP and was determined to not be a credible seismic concern. Masonry block walls, identified as D and E on drawing A-259, are safety-related and thus seismically rated per IE Bulletin 80-11.
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments C-499
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1RYRPS-K4 Equipment Class: (18) Instruments on Racks Equipment
Description:
AUTO RX TRIP K4 RELAY Evaluated by: / A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos Status: N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1SV3986 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
AUX FEED PP TURBINE 11 TRIP Project: CCNPP 1 SWEL Location (Bldg, Elev, Room/Area): TURB, 12.00 ft, CAL-AFWPR-603 Manufacturer/Model: Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments. Anchorage
- 1.
Is anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? No
- 2.
Is the anchorage free of bent, broken, missing or loose hardware? Not Applicable C-500
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1SV3986 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
AUX FEED PP TURBINE 11 TRIP
- 3.
Is the anchorage free of corrosion that is more than mild surface oxidation? Not Applicable
- 4.
Is the anchorage free of visible cracks in the concrete near the anchors? Not Applicable
- 5.
Is the anchorage configuration consistent with plant documentation? (Note: Not Applicable This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
- 6.
Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions? Interaction Effects
- 7.
Are soft targets free from impact by nearby equipment or structures? Yes The SV cover is in contact with the valve's insulation pad, Judged to not be a seismic concern.
- 8.
Are overhead equipment, distribution systems, ceiling tiles and lighting, and Yes masonry block walls not likely to collapse onto the equipment?
- 9.
Do attached lines have adequate flexibility to avoid damage? Yes Lines attached to equipment consist of flex conduit having adequate flexibility, therefore no seismic concern.
- 10.
Based on the above seismic interaction evaluations, is equipment free of Yes potentially adverse seismic interaction effects? C-501
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: Y N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1SV3986 Equipment Class:. (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
AUX FEED PP TURBINE 11 TRIP Other Adverse Conditions
- 11.
Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment? Comments Evaluated by: A. Karavoussianis Date: 11/09/2012 C. Figliolini 11/09/2012 Photos C-502
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: M N U Seismic Walkdown Checklist (SWC) Equipment ID No.: 1SV3986 Equipment Class: (8) Motor-Operated and Solenoid-Operated Valves Equipment
Description:
AUX FEED PP TURBINE 11 TRIP 1 SV3986 8-10-12 027 1SV3986 8-10-12 028 C-503
ATTACHMENT 3 WALKDOWN CHECKLISTS Status: [] N U Seismic Walkdown Checklist (SWC) Equipment ID No.: Equipment Class: 1 SV3986 (8) Motor-Operated and Solenoid-Operated Valves NE 11 TRIP 1*SV39W 6-1u-12 U3U 1 SV3986 8-10-12 029 1SV3986 8-10-12 031 C-504}}