Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 10 Status: FT ] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves EauiDment Descriotion:

SHUTDOWN COOLING/ Shut Down PumDs Suction Line Valve Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 517.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchoragie

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

Yes C-163

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 10 Status: FT I N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SHUTDOWN COOLING/ Shut Down Pumps Suction Line Valve

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Adjacent masonry wall is safety-related.

9.

Do attached lines have adequate flexibility to avoid damage?

Yes Yes

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Robust valve body and operator near gallery judged to be acceptable.

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/3/2012 Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-164

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 10 Status:

YI N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SHUTDOWN COOLING/ Shut Down Pumps Suction Line Valve C-165

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 10 Status: FYII N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-166

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 10 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-167

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 10 Status:

Y-- N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-168

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 10 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-169

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 8 of 10 Status: EY[II N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-170

Dresden Generating Station Unit 3 1200108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 9 of 10 Status: jYJ N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-171

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 10 of 10 Status:

Y-I N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0002AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-172

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 10 Status: F-- N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves EauiDment DescriDtion:

SHUTDOWN COOLING/ Iniection Line Valve Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable' Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes C-173

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-1 2-167 Sheet 2 of 10 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SHUTDOWN COOLING/ Injection Line Valve Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

Approximately 1/2-inch gap between valve 3-1001-5A yoke and operator and adjacent valve yoke. All are robust and judged to be acceptable.

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Yes Yes

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/3/2012 Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9 /30/2012 C-174

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 10 Status: r N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

SHUTDOWN COOLING/ Injection Line Valve C-175

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 10 Status: E-Z N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-176

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 10 Status: [TI N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves

-r C-177

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 10 Status: [LI N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-178

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 10 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-179

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 8 of 10 Status:

Y-] N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves JTDOWN COOLING C-180

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 9 of 10 Status: EZII N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1001-0005AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-181

Dresden Generating Station Unit 3 1200108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 10 of 10 Status: FIIY N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1001-0005AV20 (8) Motor-Operated and Solenoid-Operated Valves C-182

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 7 Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Eauioment DescriDtion:

CCSW/ Heat Exchanaer Outlet Service Water Line Valve Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes C-183

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 7 Seismic Walkdown Checklist (SWC)

Status: ELI N U Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

CCSW/ Heat Exchanqer Outlet Service Water Line Valve Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Light fixture with I of 2 chains unsupported at hard-wired cord end judged acceptable.

9.

Do attached lines have adequate flexibility to avoid damage?

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Yes Yes Yes Other Adverse Conditions *

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/1/2012 Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-184

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 7 Status: [Y] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

CCSW/ Heat Exchanger Outlet Service Water Line Valve C-185

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 7 Status: [1 N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-186

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 7 Status:

Y-] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-187

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 7 Status: FY1 N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1501-0003AV20 (8) Motor-Operated and Solenoid-Operated Valves C-188

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 7 Status: lJ N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0003AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-189

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 11 Status: FYi N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

LPCI/ LPCI Injection Line Valve Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 517.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes C-190

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 11 Status: Eli] N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

LPCI/ LPCI Injection Line Valve Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Overhead light fixtures are judged to be acceptable.

9.

Do attached lines have adequate flexibility to avoid damage?

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Yes Yes Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/1/2012 For upper area walk-by, see U3 East HCU Bank area walk-by notes from 7/31/12.

Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-191

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 11 Status: r N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves EauiDment

Description:

LPCI/ LPCI Iniection Line Valve C-192

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 11 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Line 1

P 20120801-Dresden-3 058 w

C-193

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 11 Status: E-1 N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves i Lir C-194

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 11 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-195

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 11 Status: T N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1501-0021AV20 (8) Motor-Operated and Solenoid-Operated Valves I-C-196

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 8 of 11 Status:

Y-] N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-197

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 9 of 11 Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-198

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 10 of 11 Status:

Y-L N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves n Line Valve C-199

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 11 of 11 Status: [I N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0021AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves EauiDment DescriDtion:

LPCI/ LPCI Iniection Line Valve C-200

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 7 Status: Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Equipment

Description:

LPCI/ LPCI Header Crosstie Line Valve Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes C-201

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 7 Status: F N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves EauiDment

Description:

LPCI/ LPCI Header Crosstie Line Valve Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Overhead light fixtures judged to be acceptable.

9.

Do attached lines have adequate flexibility to avoid damage?

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Yes Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/1/2012 Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-202

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 7 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves Eauipment

Description:

LPCI/ LPCI Header Crosstie Line Valve C-203

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 7 Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-204

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-1 2-167 Sheet 5 of 7 Status: Yj N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-205

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 7 Status: L-ul N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0032AV20 Equipment Class:

(8) Motor-Operated and Solenoid-Operated Valves C-206

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 7 Status: F N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1501-0032AV20 (8) Motor-Operated and Solenoid-Operated Valves C-207

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet I of 9 Status:

T N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps Equipment

Description:

CCSW/ CCSW Pump "A" Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Turbine, 495.00 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

Yes

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Yes

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

Yes

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

Yes Minor shrinkage cracks in floor judged to be acceptable.

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Yes

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yes C-208

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev, 2 Correspondence No.: RS-12-167 Sheet 2 of 9 Status:

YI N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps Eauipment DescriDtion:

CCSW/ CCSW PumD "A" Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

Tube touches pump casing; judged acceptable due to flexibility of tube and robustness of pump casing.

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

One overhead light fixture above with one open S-hook on one chain at one end of fixture. Other chain at same end has a closed S-hook. Light fixture judged to be acceptable.

9.

Do attached lines have adequate flexibility to avoid damage?

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Yes Yes Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments SEWS Anchorage Notes:

Pump bolted with six 7/8" Cast-in-place bolts (3 on each side).

Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 7/31/2012 Evaluated by:

James Griffith Date:

9/30/2012 S

Michael Wodarcyk 9/30/2012 C-209

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 9 Status: FYý N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps Equipment

Description:

CCSW/ CCSW Pump "A" Photos C-210

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 9 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps VAI tl'tPA C;

C-211

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 9 Status: -

N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps IIA" C-212

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 9 Status: [*

N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps "A"

C-213

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 9 Status: EYII N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps Lm C-214

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 8 of 9 Status:

Y-] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps C-im-r1ýoinC~n PPQAII PI'QIAIDim "l

C-215

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 9 of 9 Status: [*

N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1501-0044AP30 Equipment Class:

(5) Horizontal Pumps C-216

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 10 Status:

Y1 N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A ---- P30 Equipment Class:

(6) Vertical Pumps Equipment

Description:

LPCI/ LPCI Injection Pump "A" Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

Yes of SWEL items requiring such verification)?

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Yes

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

Yes

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

Yes Minor grout pad cracking near bolts judged to be acceptable because bolts are cast in place into the concrete slab.

5.

Is the anchorage configuration consistent with plant documentation? (Note:

Yes This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6.

Based on the above anchorage evaluations, is the anchorage free of Yes potentially adverse seismic conditions?

C-217

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 10 Status: T N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A ---- P30 Equipment Class:

(6) Vertical Pumps Equipment

Description:

LPCI/ LPCI Injection Pump "A" Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Yes

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments SEWS Anchorage Notes:

Vertical pump is anchored with four 1" Cast-in-Place bolts.

Seismic Walkdown Team: J. Griffith & M. Wodarcyk - 8/1/2012 Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-218

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 10 Status:

T N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A---P30 Equipment Class:

(6) Vertical Pumps Eauipment

Description:

LPCI/ LPCI Injection Pump "A" Photos C-219

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 10 Status: Liii N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A---P30 Equipment Class:

(6) Vertical Pumps I DtII I D('I C-220

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 10 Status: FYii N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A---P30 Equipment Class:

(6) Vertical Pumps C-221

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 10 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A--P30 Equipment Class:

(6) Vertical Pumps Pump "A" 20120801 -Dresden-3 345 C-222

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 10 Status: T N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1 502-A--- P30 (6) Vertical Pumps C-223

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 8 of 10 Status: [-ý N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A---P30 Equipment Class:

(6) Vertical Pumps

=^-inm~nf FlI-ir~nfit~n-I DPCIl I P*I InLa,4it* n Paimn "A" C-224

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 9 of 10 Status: F-ý N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A--P30 Equipment Class:

(6) Vertical Pumps C-225

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 10 of 10 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1502-A--P30 Equipment Class:

(6) Vertical Pumps Eauioment DescriDtion:

LPCI/ LPCI Injection PumD "A" C-226

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 1 of 7 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A ---- H15 Equipment Class:

(21) Tanks and Heat Exchangers Equipment

Description:

LPCI/ LPCI Heat Exchanger Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item.of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Yes Yes Yes

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

Mounted directly to gallery steel.

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Not Applicable Yes Yes C-227

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 7 Status: EYI N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A ---- H15 Equipment Class:

(21) Tanks and Heat Exchangers Equipment

Description:

LPCI/ LPCI Heat Exchanger Interaction Effects

7.

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

IR 1396014:

LIGHT FIXTURE CONNECTION DEFICIENCY During the Seismic Walkdowns it was identified that a light fixture just west of the 3A Hx in the SE LPCI Comer Room had a detached chain on one side of the fixture. However, the other chain at the same end of the fixture was securely attached and the two chains at the other end of the fixture were also securely attached. Therefore, the fixture is judged to be acceptable.

9.

Do attached lines have adequate flexibility to avoid damage?

Yes Yes Yes

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments SEWS Anchorage Notes:

SRT: R. P. Kennedy & J. D. Stevenson, 3/4-3/8/96.

This vertical heat exchanger is 60" in diameter and supported at approx. 2/3 its height by a floor system composed of wide flange beams.

Seismic Walkdown Team: J. Griffith & M. Wodarcyk-8/1/2012 C-228

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 7 Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A--H15 Equipment Class:

(21) Tanks and Heat Exchangers EquiDment DescriDtion:

LPCI/ LPCI Heat Exchanaer Evaluated by:

James Griffith Date:

9/30/2012 Michael Wodarcyk 9/30/2012 C-229

Dresden Generating Station Unit 3 1200108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 7 Status:

Y N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

003-1 503-A-Hi 5 (21) Tanks and Heat Exchangers I D0'1l I DfIl L C-230

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 7 Status: [*

N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A--H15 Equipment Class:

(21) Tanks and Heat Exchangers

~nm inmat flep~nj~n I PC'*II I P(I W)n' F1 '-Innr C-231

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 6 of 7 Status:

Y N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A--H15 Equipment Class:

(21) Tanks and Heat Exchangers C-232

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 7 of 7 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1503-A-H15 Equipment Class:

(21) Tanks and Hea I'..:.,,.s a

a vIes1 I vIe'*s UA *& I*

t Exchangers C-233

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167

  • Sheet 1 of 5 Status: T N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1541 -----

A-FE Equipment Class:

(18) Instruments on Racks Equipment

Description:

CCSW/ CCSW Pump "A" and "B" Discharge Flow Element Project:

Dresden 3 SWEL Location (Bldg, Elev, Room/Area):

Reactor, 476.50 ft, ALL Manufacturer/Model:

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1.

Is anchorage configuration verification required (i.e., is the item one of the 50%

of SWEL items requiring such verification)?

No

2.

Is the anchorage free of bent, broken, missing or loose hardware?

Not Applicable

3.

Is the anchorage free of corrosion that is more than mild surface oxidation?

4.

Is the anchorage free of visible cracks in the concrete near the anchors?

5.

Is the anchorage configuration consistent with plant documentation? (Note:

This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Not Applicable Not Applicable Not Applicable

6.

Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Flow element is in pipeline (in-line component).

Yes C-234

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 2 of 5 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1541 -----

A-FE Equipment Class:

(18) Instruments on Racks Equipment

Description:

CCSW/ CCSW Pump "A" and "B" Discharge Flow Element Interaction Effects 7,

Are soft targets free from impact by nearby equipment or structures?

Yes

8.

Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Yes

9.

Do attached lines have adequate flexibility to avoid damage?

Yes

10.

Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Yes Other Adverse Conditions

11.

Have you looked for and found no adverse seismic conditions that could Yes adversely affect the safety functions of the equipment?

Comments Seismic Walkdown Team: J. Griffith & M. Wodarcyk-8/3/2012 Reference Drawing:

M-392, Rev. T.

Evaluated by:

James Griffith Date:

10/24/2012 Michael Wodarcyk 10/24/2012 C-235

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 3 of 5 Status: F N U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1541 -----

A-FE Equipment Class:

(18) Instruments on Racks Equipment

Description:

CCSW/ CCSW Pump "A" and "B" Discharge Flow Element C-236

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 4 of 5 Status: F N

U Seismic Walkdown Checklist (SWC)

Equipment ID No.:

D03-1541 -----

A-FE Equipment Class:

(18) Instruments on Racks C-237

Dresden Generating Station Unit 3 12Q0108.30-R-002, Rev. 2 Correspondence No.: RS-12-167 Sheet 5 of 5 Status:

Yl] N U

Seismic Walkdown Checklist (SWC)

Equipment ID No.:

Equipment Class:

D03-1541- -----

A-FE (18) Instruments on Racks rr(Z%~AII rr'QIAI P "A"

C-238