ML12340A437

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - Acceptance of Dresden Units 2 and 3, Relief Request Associated with Fifth Inservice Testing Intercal (ME9865 Through ME9872)
ML12340A437
Person / Time
Site: Dresden  
Issue date: 12/04/2012
From: Nicholas Difrancesco
Plant Licensing Branch III
To: Mathews M
Exelon Corp
References
TAC ME9865, TAC ME9872
Download: ML12340A437 (3)


Text

1 NRR-PMDAPEm Resource From:

DiFrancesco, Nicholas Sent:

Tuesday, December 04, 2012 5:12 PM To:

Mitchel.Mathews@exeloncorp.com Cc:

Faria-Ocasio, Carolyn; Dudek, Michael; patrick.simpson@exeloncorp.com; Mozafari, Brenda

Subject:

Acceptance of Dresden Units 2 and 3, Relief Request Associated with Fifth Inservice Testing Intercal (ME9865 through ME9872)

Mr. Mathews, By letter dated October 30, 2012 (Agencywide Document Access and Management System (ADAMS)

Accession No. ML12305A532), Exelon Generation Company, LLC (EGC) submitted a relief requests for Dresden Nuclear Power Station, Units 2 and 3. The purpose of this e-mail is to provide the results of the U.S.

Nuclear Regulatory Commission (NRC) staffs acceptance review of these relief requests. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. The proposed relief requests would authorize the actions listed in the table below:

Relief Request TAC Nos.

Summary of Request Applicable 10 CFR 50.55a paragraph RV-01 ME9869/70 Apply additional tolerances to the testing frequencies described in the ASME OM Code as an alternative from the frequency specifications of the ASME OM Code.

50.55a(a)(3)(ii)

RV-02 ME9867/68 Use ASME Code Case OMN-1, Revision 1 for the testing of active, non-skid mounted, ASME Class 1, 2 and 3 motor-operated valves (MOVs) in the DNPS MOV testing programas an alternative to requirements of the OM Code (ISTC-3100,3310,3510,3521,3700,5120) 50.55a(a)(3)(i)

RV-02C ME9865/66 Allow six-year IST frequency with allowance for an additional six-month grace period for the DNPS main steam safety valves as an alternative to the five

-year test interval requirement of ASME OM Code, Appendix I, Section I-1320(a).

50.55a(a)(3)(ii)

RV-23H ME9871/72 Use of High Pressure Coolant Injection system exhaust line drain valve testing as an alternative method as an alternative to ISTC-5150 requirements of OM Code 50.55a(a)(3)(ii)

The NRC staff has reviewed your letter and concluded that relief requests, provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

2 If you have any questions, please contact Carolyn Faria-Ocasio at (301) 415-4050.

In accordance with our process as described in LIC-109, "Acceptance Review Procedures," I am placing a copy of this email in ADAMS as a publicly-available, official agency record.

Sincerely, Nicholas DiFrancesco Project Manager Plant Licensing Branch III-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation nicholas.difrancesco@nrc.gov l Tel: (301) 415-1115

Hearing Identifier:

NRR_PMDA Email Number:

551 Mail Envelope Properties (8DBF4F9959B56A41BFAD44DF618A435B06713255E3)

Subject:

Acceptance of Dresden Units 2 and 3, Relief Request Associated with Fifth Inservice Testing Intercal (ME9865 through ME9872)

Sent Date:

12/4/2012 5:11:35 PM Received Date:

12/4/2012 5:11:00 PM From:

DiFrancesco, Nicholas Created By:

Nicholas.DiFrancesco@nrc.gov Recipients:

"Faria-Ocasio, Carolyn" <Carolyn.Faria-Ocasio@nrc.gov>

Tracking Status: None "Dudek, Michael" <Michael.Dudek@nrc.gov>

Tracking Status: None "patrick.simpson@exeloncorp.com" <patrick.simpson@exeloncorp.com>

Tracking Status: None "Mozafari, Brenda" <Brenda.Mozafari@nrc.gov>

Tracking Status: None "Mitchel.Mathews@exeloncorp.com" <Mitchel.Mathews@exeloncorp.com>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 3258 12/4/2012 5:11:00 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: