United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.

In the Matter of:

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #: NRC000085-00-BD01 Identified: 10/15/2012 Admitted: 10/15/2012 Withdrawn: NRC000085 Rejected: Stricken:

Other: Submitted: March 30, 2012 APPENDIX B U.S. Commercial Nuclear Power Reactors Permanently Shut DownFormerly Licensed To Operate Reactor Decommissioning Unit Type NSSS OL Issued Alternative Selected Location MWt Vendor Shut Down Current Status Big Rock Point BWR GE 05/01/1964 DECON Charlevoix, MI 240 08/29/1997 DECON Completed GE Bonus* BWR CE 04/02/1964 ENTOMB Punta Higuera, PR 50 06/01/1968 ENTOMB CVTR** PTHW WEST 11/27/1962 SAFSTOR Parr, SC 65 01/01/1967 SAFSTOR Dresden 1 BWR GE 09/28/1959 SAFSTOR Morris, IL 700 10/31/1978 SAFSTOR Elk River* BWR AC/S&L 11/06/1962 DECON Elk River, MN 58 02/01/1968 DECON Completed Fermi 1 SCF CE 05/10/1963 DECON Newport, MI 200 09/22/1972 DECON in Progress Fort St. Vrain HTG GA 12/21/1973 DECON Platteville, CO 842 08/18/1989 DECON Completed GE VBWR BWR GE 08/31/1957 SAFSTOR Sunol, CA 50 12/09/1963 SAFSTOR Haddam Neck PWR WEST 12/27/1974 DECON Meriden, CT 1,825 12/05/1996 DECON Completed Hallam* SCGM BLH 01/02/1962 ENTOMB Hallam, NE 256 09/01/1964 ENTOMB NS Savannah PWR B&W 08/1965 SAFSTOR Baltimore, MD 74 11/1970 SAFSTOR Humboldt Bay 3 BWR GE 08/28/1962 DECON Eureka, CA 200 07/02/1976 DECON In Progress Indian Point 1 PWR B&W 03/26/1962 SAFSTOR Buchanan, NY 615 10/31/1974 SAFSTOR La Crosse BWR AC 07/03/1967 SAFSTOR Genoa, WI 165 04/30/1987 SAFSTOR Maine Yankee PWR CE 06/29/1973 DECON Wiscasset, ME 2,700 12/06/1996 DECON Completed Millstone 1 BWR GE 10/31/1970 SAFSTOR Waterford, CT 2,011 07/21/1998 SAFSTOR Path"nder BWR AC 03/12/1964 DECON Sioux Falls, SD 190 09/16/1967 DECON Completed APPENDIX APPENDIXA-B B

Peach Bottom 1 HTG GA 01/24/1966 SAFSTOR Delta, PA 115 10/31/1974 SAFSTOR 2010-2011 Information Digest t 115

APPENDIX B U.S. Commercial Nuclear Power Reactors Permanently Shut DownFormerly Licensed To Operate (continued)

Reactor Decommissioning Unit Type NSSS OL Issued Alternative Selected Location MWt Vendor Shut Down Current Status Piqua* OCM AI 08/23/1962 ENTOMB Piqua, OH 46 01/01/1966 ENTOMB Rancho Seco PWR B&W 08/16/1974 DECON Herald, CA 2,772 06/07/1989 DECON Completed San Onofre 1 PWR WEST 03/27/1967 DECON San Clemente, CA 1,347 11/30/1992 DECON In Progress Saxton PWR WEST 11/15/1961 DECON Saxton, PA 23.5 05/01/1972 DECON Completed Shippingport* PWR WEST N/A DECON Shippingport, PA 236 1982 DECON Completed Shoreham BWR GE 04/21/1989 DECON Wading River, NY 2,436 06/28/1989 DECON Completed Three Mile Island 2 PWR B&W 02/08/1978 (1)

Middletown, PA 2,770 03/28/1979 Trojan PWR WEST 11/21/1975 DECON Rainier, OR 3,411 11/09/1992 DECON Completed Yankee-Rowe PWR WEST 12/24/1963 DECON Rowe, MA 600 10/01/1991 DECON Completed Zion 1 PWR WEST 10/19/1973 DECON Zion, IL 3,250 02/21/1997 DECON In Progress Zion 2 PWR WEST 11/14/1973 DECON Zion, IL 3,250 09/19/1996 DECON In Progress

  • AEC/DOE owned; not regulated by the U.S. Nuclear Regulatory Commission.

Notes: See Glossary for de"nitions of decommissioning alternatives (DECON, ENTOMB, SAFSTOR).

(1) Three Mile Island Unit 2 has been placed in a postdefueling monitored storage mode until Unit 1 permanently ceases operation, at which time both units are planned to be decommissioned.

Source: DOE Integrated Database for 1990; U.S. Spent Fuel and Radioactive Waste, Inventories, Projections, and Characteristics (DOE/RW-0006, Rev. 6), and U.S. Nuclear Regulatory Commission, Nuclear Power Plants in the World, Edition 6 116 t U.S. NRC Protecting People and the Environment