Dose Calculations for Aquatic Biota in the Hudson River Water Concentration in Hudson River pCi/L*

Bq/L H-3 10 0.37 Sr-90 20 0.74

  • Provided by M. Barvenik Bioconcentation Factor L/kg H-3 1

Sr-90 320 Concentration in aquatic biota Bq/kg H-3 0.37 Sr-90 237.04 Dose Coefficients (from UNSCEAR 2008 Report)

External ExposureInternal Exposure uGy/h per Bq/kg uGy/h per Bq/kg H-3 8.2E-11 3.3E-06 Sr-90 2.0E-04 6.3E-04 Dose rate - aquatic biota External ExposureInternal Exposure uGy/h uGy/h H-3 3.0E-11 1.2E-06 Sr-90 4.7E-02 1.5E-01 External ExposureInternal Exposure Total Dose Rate (UNSCEAR 2008)

Total Dose Rate (RESRAD-BIOTA) rad/d rad/d rad/d rad/d H-3 7.3E-14 2.9E-09 2.9E-09 2.1E-09 Sr-90 1.1E-04 3.6E-04 4.7E-04 3.7E-04 F. Owen Hoffman, Ph.D.