ML12338A627

From kanterella
Jump to navigation Jump to search
Official Exhibit - ENT00331G-00-BD01 - Indian Point Energy Center - Sheet 7.1, Schematic of Injection Well Location and Design Through Figure 8.3, Bounding Cesium (Cs), Cobalt (Co) and Nickel (Ni) Activity in Groundwater
ML12338A627
Person / Time
Site: Indian Point  
Issue date: 03/29/2012
From:
GZA GeoEnvironmental
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 22127, 50-247-LR, ASLBP 07-858-03-LR-BD01, 50-286-LR, Job 41.0017869.10
Download: ML12338A627 (6)


Text

ENT00331G Submitted: March 29, 2012 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

ENT00331G-00-BD01 10/15/2012 10/15/2012

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

I-2 U3-3 U3-2 U3-1 RW-1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-108 MW-107 MW-58 MW-109 U3-Discharge Canal U1-NCD U1-SFDS 13.1 10.3 42.8 8.2 6.7 8.2 35.4 30.7 1.1 1.1 1.1 12.46

-0.5 0.8 0.3 1.7 0.8 0.7 1.0 1.1 0.3 0.6 5.1 21.1 DRY 2.2 7.1 6.0 5.3 9.8 3.9 2.9 9.6 9.4 8.6 0.7 0.7 24.7 18.6 22.7 24.0 24.8 25.0 39.1 59.4 53.1 58.1 52.4 49.4 50.2 0.9 1.1 0.4 50.6 37.8 41.8 7.1 7.2 8.0 6.0 9.1 10.0 21.0 5.5 4.5 5.4 4.3 5.5 1.3 7.4 7.5 35.6 34.5 22.3 1.4 25.9 26.4 25.7 30.9 12.8 1.0 0.6 33.4 21.8 1.2 28.2 1.1 0.9 1.1 28.5 39.6 41.6 23.1 0.9 1.0 0.7 29.9 0.3 0.9 8.9 3.7 7.5 5.3 4.3 9.6 6.9 9.9 3.0 8.1 8.5 6.0 9.9 9.5 4.2 1.4 5.2 8.9 5.7 6.6 9.6 0.6 0.5 11.8 0.9 12.8 44.1 10.1 32.8 0.1

-0.5

-0.6 0.3

-0.1 0.0 116.8 55.0 0.1 storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open grate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Concrete Retaining Wall Stone retaining wall Gravel parking Gravel parking Gravel parking Asphalt parking Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt curb Grass Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRANSFER POOL STORAGE POOL STORAGE POOL FAILED FUEL AUX. POOL DISASSEMBLY POOL CASK LOAD POOL CASK WASH & DISASSEMBLY ISOLATION PIT ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' 45.6 24.6 26.6 33.6 96.6 105.0 47.9 56.9 60.1 24.9 28.6 0.1 27.2 6.9 19.6-89.6 74.6 73.6 46.6 18.1 97.1 5.1 48.6 31.6-59.6 15.0 96.6 66.6 75.6 42.6 24.6 60.9 42.6 42.9 34.9 89.6 46.6 90.6 81.6 25.2 33.1 25.2 25.2 69.2 48.6 60.9 31.6 24.6 1.1 2.0 0.2 18.0 5.0 26.6 171.6 25.2 14.6 2.6 14.6 5.6 20.6 255 0.1 ND ND ND ND ND ND ND 0.16 ND ND ND ND ND ND ND ND 0.1 ND ND ND ND ND ND ND ND ND 0.02 ND ND ND ND 0.52 ND ND 14.4 ND ND ND 0.7 ND 0.1 0.06 ND ND ND ND ND 0.6 ND ND ND ND ND ND ND ND 0.1 621 0.16 ND 0.05 0.07 24300 ND 1810 1.7 ND 49000 ND 167 ND ND ND 15300 4160 0.1 ND ND 0.3 ND ND ND ND 12700 ND ND ND 0.054 1600 0.002 5690 1.9 46.8 0.1 ND ND ND ND 1.3 40.4 22.8 ND 5.17 ND 23.3 0.95 0.05 0.6 0.65 ND 0.23 ND 23.1 ND ND ND 0.63 0.63 19.1 ND 6.6 ND 13.8 13.8 43.1 985 264 754 41.4 ND ND 1.7 0.3 0.17 4.2 1.3 MH-4 MH-4A MH-5 MH-6 MH-2 CB-B6A CB-B6 U3-CB-B5 U3-CB-B4 U3-CB-B4A U3-CB-B3 U3-CB-B3A U3-CB-B2A U3-CB-B2 U3-CB-B1 U3-CB-A2 U3-CB-A1 U3-MH-14 F5 U3-CB-A2A CB-B CB-E CB-F CB-1 (CB-G)

XX D2 U3-CB-B7 B5 U3-CB-B8 XX CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 U3-CB-A7 (U3-CB-11)

U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 (CB-24)

CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C U3-CB-E1 U3-CB-A6 U3-CB-A5 CB-A3A U3-CB-A3 U3-CB-A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 40 30 20 10 5

20 13 50 40 30 20 10 5

50 Transformer Yard PAB East Fuel Pool Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 U2-C1 HR-1 U3-C1 OUT-1 ALL EY WAY UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH CSS H U D S O N R I V E R J:\\17869\\17869-10\\Figures\\GIS\\MXD Documents\\17869-10_7-2_Max_Tracer_v10.mxd LEGEND Data Notes:

1. Boundary tracer plume represents upper bound concentration measured over both depth and time (available results for sample dates through 8/21/2007). As such, these data are an overstatement of tracer concentrations actually existing on-site at any time.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey & Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".
2. Additional legend on Figure 1.3.

Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS/EMD 41.0017869.10 1-04-2008 7.2 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 Note:

Groundwater contours developed from limited data available on 6/1/2007. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

BOUNDING TRACER (FLUORESCEIN) CONCENTRATION ISOPLETHS BOUNDING TRACER (FLUORESCEIN)

CONCENTRATION ISOPLETHS IN GROUNDWATER Groundwater Elevation Contours Contours Other Than 10' Interval Ambient "Watertable" Contours 6/1/2007 (10' Interval) 20 5

1 1

Concentration Data1 Isopleths; Fluorescein Peak, ug/L 50 - 500 500 - 5,000 5,000 - 50,000

> 50,000 5 - 50 Containment Spray Sump Trench Probable Legacy Release Locations Unit 2 Fuel Pool Terminated Connection To Storm Drain Footing / Storm Drain Exfiltration Inter-Structure Joint / Mud Mat Unit 1 West Fuel Pool Well ID Date Sample Collected Days Until Peak Tracer Arrival1 Max Tracer Concentration (ppb)2 Well ID Date Sample Collected Days Until Peak Tracer Arrival Max Tracer Concentration (ppb)2 I-2 NA3 ND4 MW-52-122 NA ND MH-2 NA ND MW-52-162 NA ND MH-4 3/5/07 24.6 41.40 MW-52-181 NA ND MH-4A NA ND MW-53-82 2/26/07 18.1 5.2 MH-5 3/5/07 24.6 43.1 MW-53-120 NA ND MH-6 2/28/07-5/9/07 19.6-89.6 13.8 MW-54-376 3/5/07 24.6 1.0 MW-30-69 3/12/07-4/9/07 31.6-59.6 5,690 MW-54-586 3/5/07 24.6 0.6 MW-30-84 4/9/07 60.1 167 MW-54-1236 3/5/07 24.6 0.6 MW-31-49 2/8/07 0.1 1,600 MW-54-1636 3/5/07 24.6 0.6 MW-31-63 2/23/07 15.0 12,700 MW-54-1906 3/5/07 24.6 0.7 MW-31-85 2/13/07 5.1 1,810 MW-55-24 3/28/07 47.9 0.1 MW-32-62 2/9/07 1.1 49,000 MW-55-35 3/13/07 33.1 0.2 MW-32-92 2/8/07 0.2 24,300 MW-55-54 3/15/07 34.9 1.1 MW-32-140 2/10/07 2.0 15,300 MW-56-53 NA ND MW-32-165 2/13/07 5.0 4,160 MW-56-83 NA ND MW-32-197 2/26/07 18.0 621 MW-57-11 3/7/07 26.6 14.4 MW-33 3/5/07 24.9 6.6 MW-57-20 NA ND MW-34 3/26/07 45.6 0.1 MW-57-45 NA ND MW-35 4/6/07 56.9 0.1 MW-58-26 3/23/07 42.6 0.6 MW-36-24 4/23/07 73.6 0.002 MW-58-65 5/10/07 90.6 0.16 MW-36-41 4/10/07 60.9 0.054 MW-59-32 5/1/07 81.6 0.16 MW-36-52 NA ND MW-59-45 NA ND MW-37-22 4/10/07 60.9 46.8 MW-59-68 NA ND MW-37-32 3/23/07 42.9 1.3 MW-60-35 5/16/07 96.6 0.1 MW-37-40 NA ND MW-60-53 NA ND MW-37-57 3/23/07 42.6 0.1 MW-60-72 NA ND MW-38 3/27/07 46.6 0.051 MW-60-135 NA ND MW-39-67 NA ND MW-60-154 NA ND MW-39-84 NA ND MW-60-176 NA ND MW-39-100 NA ND MW-62-18 5/16/07 97.1 0.1 MW-39-124 NA ND MW-62-37 5/16/07 96.6 0.1 MW-39-183 NA ND MW-62-53 NA ND MW-39-195 NA ND MW-62-71 NA ND MW-40-24 NA ND MW-62-92 NA ND MW-40-46 NA ND MW-62-138 NA ND MW-40-81 NA ND MW-62-182 NA ND MW-40-100 NA ND MW-63-18 NA ND MW-40-127 NA ND MW-63-29 NA ND MW-40-162 NA ND MW-63-50 NA ND MW-41-13 NA ND MW-63-93 NA ND MW-41-40 NA ND MW-63-112 NA ND MW-41-63 NA ND MW-63-121 NA ND MW-42-49 2/15/07 6.9 1.9 MW-63-163 NA ND MW-42-78 3/7/07 27.2 1.7 MW-63-174 NA ND MW-44-67 NA ND MW-65-48 NA ND MW-44-104 NA ND MW-65-80 NA ND MW-45-43 NA ND MW-66-21 NA ND MW-45-67 NA ND MW-66-36 7/30/07 171.6 0.05 MW-46 NA ND MW-66 (48)5 NA ND MW-47-56 NA ND MW-66 (115)

NA ND MW-47-80 NA ND MW-66 (135)

NA ND MW-48-23 NA ND MW-66 (190)

NA ND MW-48-37 NA ND MW-107 NA ND MW-49-26 5/9/07 89.6 0.23 MW-108 3/9/07 28.6 0.6 MW-49-42 NA ND MW-111 3/29/07 48.6 19.1 MW-49-65 NA ND RW-1 (97) 2/23/07 14.6 255.0 MW-50-42 NA ND RW-1 (110) 2/11/07 2.6 985.0 MW-50-66 NA ND RW-1 (118) 2/23/07 14.6 264.0 MW-51-40 NA ND RW-1 (140) 2/14/07 5.6 754.0 MW-51-79 NA ND CSS 4/16/07 66.6 1.7 MW-51-102 NA ND HR-1 3/12/07 31.6 0.17 MW-51-135 NA ND U1-CSS 3/7/07 26.6 23.3 MW-51-163 NA ND U1-NCD 3/14/07 33.6 4.2 MW-51-189 NA ND U1-SFDS 3/1/07 20.6 1.3 MW-52-11 NA ND U2-C1 3/29/07 48.6 0.5 MW-52-18 NA ND U3-3 3/27/07 46.6 0.07 MW-52-48 5/24/07 105.0 0.02 U3-4D 4/25/07 75.6 0.06 MW-52-64 NA ND U3-C1 3/5/07 24.6 0.3 U3-Discharge Canal 4/24/07 74.6 0.3

1) Tracer Injected on 2/8/2007 at approximately 10:30 AM.
2) Shaded cells indicate sample collected via charcoal packets. Concentrations are expressed as g/day.
3) NA: Not Applicable
4) ND: Not Detected. Water sample detection limit is 0.002 g/l. Carbon sample elutant detection limit is 0.025 g/l.
5) Numbers in parenthesis indicate sample collection depths in an open borehole.
6) Peak tracer sample from MW-54-163 was collected from a packered sampling interval no longer in place. Other MW-54 samples listed were extracted from former packered sample zones reasonably equivalent to those currently in place.

Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth Depth-Specific Data 11.3 11.9 12.6 12.8 Groundwater elevation at time of low river tide for each screened interval, 6/1/2007.

5.1 56.0 24.6 24.9 Time elapsed until peak tracer arrival for each sampled interval.

5250 600 22 5.25 Water sample concentration of Fluorescein (ug/L) for each screened Interval.

Carbon sampler concentration of Fluorescein (ug/day) for each screened Interval.

Bar Graphs; Bounding Fluorescein, ug/day Bar Graphs; Bounding Fluorescein, ug/L Not Detected (ND)

ND - < 1 1 - 5 5 - 25 25 - 50 50 - 500 500 - 5,000 5,000 - 50,000 Not Measured ND 0.5 4

8 32 250 700 25,000 Not Detected (ND)

ND - < 1 1 - 5 5 - 10 10 - 15 15 - 25 Not Measured ND 0.5 2

7 12 16

?

Boring / Monitoring Installation Designation MW-30 Boring / Monitoring Installation

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

I-2 U3-3 U3-2 U3-1 RW-1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-108 MW-107 MW-58 MW-109 MH-4 MH-4A MH-5 MH-6 MH-2 CB-B6A CB-B6 U3-CB-B5 U3-CB-B4 U3-CB-B4A U3-CB-B3 U3-CB-B3A U3-CB-B2A U3-CB-B2 U3-CB-B1 U3-CB-A2 U3-CB-A1 U3-MH-14 F5 U3-CB-A2A CB-B CB-E CB-F CB-1 (CB-G)

XX D2 U3-CB-B7 B5 U3-CB-B8 XX CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 U3-CB-A7 (U3-CB-11)

U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 (CB-24)

CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C U3-CB-E1 U3-CB-A6 U3-CB-A5 CB-A3A U3-CB-A3 U3-CB-A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 U3-Discharge Canal U1-NCD U1-SFDS 13.1 10.3 42.8 8.2 6.7 8.2 35.4 30.7 1.1 1.1 1.1 12.46

-0.5 0.8 0.3 1.7 0.8 0.7 1.0 1.1 0.3 0.6 5.1 21.1 DRY 2.2 7.1 6.0 5.3 9.8 3.9 2.9 9.6 9.4 8.6 0.7 0.7 24.7 18.6 22.7 24.0 24.8 25.0 39.1 59.4 53.1 58.1 52.4 49.4 50.2 0.9 1.1 0.4 50.6 37.8 41.8 7.1 7.2 8.0 6.0 9.1 10.0 21.0 5.5 4.5 5.4 4.3 5.5 1.3 7.4 7.5 35.6 34.5 22.3 1.4 25.9 26.4 25.7 30.9 12.8 1.0 0.6 33.4 21.8 1.2 28.2 1.1 0.9 1.1 28.5 39.6 41.6 23.1 0.9 1.0 0.7 29.9 0.3 0.9 8.9 3.7 7.5 5.3 4.3 9.6 6.9 9.9 3.0 8.1 8.5 6.0 9.9 9.5 4.2 1.4 5.2 8.9 5.7 6.6 9.6 0.6 0.5 11.8 0.9 12.8 44.1 10.1 32.8 0.1

-0.5

-0.6 0.3

-0.1 0.0 116.8 55.0 0.1 storage Gravel Storage Sign Concrete sidewalk Concrete sidewalk Concrete sidewalk Concrete sidewalk Concrete sidewalk Concrete sidewalk Concrete sidewalk Conc. sidewalk Concrete sidewalk Asphalt sidewalk Trans.

Asphalt Concrete sidewalk Concrete sidewalk Transformer area and switch gear Storage Concrete sidewalk Conc. sidewalk Wooden walk Tank Sidewalk Transformer yard Concrete sidewalk Concrete sidewalk Storage Storage Tank Fuel Oil Storage units Tank Concrete sidewalk Concrete walk Wood walk Concrete walk Sidewalk Concrete 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 140 140 Transformer Storage Tank Fuel Oil Tank Tank Tank Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Transformers on raised Concrete Pad Tank Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Trans Trans Trans Storage Tanks Concrete sidewalk Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank FUEL TRANSFER POOL STORAGE POOL STORAGE POOL FAILED FUEL AUX. POOL DISASSEMBLY POOL CASK LOAD POOL CASK WASH & DISASSEMBLY ISOLATION PIT ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' 40 30 20 10 5

20 13 50 40 30 20 10 5

50 64 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 0.019 ND ND ND ND 0.11 ND ND 0.11 ND ND ND 0.039 ND 0.16 0.059 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 56 0.15 ND ND ND 446 ND 1.8 0.37 ND 2.2 ND 86 ND ND ND 5.9 16.4 ND ND ND ND ND ND ND ND 82.7 ND ND ND ND 0.36 ND 2300 0.045 7.0 ND ND ND ND ND 0.099 0.13 ND ND ND ND ND ND ND ND ND 0.22 ND 0.056 ND ND ND 0.05 0.04 2.9 ND 0.93 ND 14.4 13.8 0.17 13.2 0.25 ND ND ND 0.11 ND 2.2 0.16 ND Transformer Yard PAB East Fuel Pool Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 U2-C1 HR-1 U3-C1 OUT-1 ALL EY WAY UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH CSS H U D S O N R I V E R J:\\17869\\17869-10\\Figures\\GIS\\MXD Documents\\17869-10_7-3_Curr_Tracer_v10.mxd LEGEND Data Notes:

1. Current tracer isopleths represent the most recent concentrations measured over depth through 6/14/07.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey & Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".
2. Additional legend on Figure 1.3.

Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS/EMD 41.0017869.10 1-4-2008 7.3 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 Note:

Groundwater contours developed from limited data available on 6/1/2007. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

Bar Graphs; Current Fluorescein, ug/L CURRENT TRACER (FLUORESCEIN) CONCENTRATION ISOPLETHS IN GROUNDWATER CURRENT TRACER (FLUORESCEIN)

CONCENTRATION ISOPLETHS IN GROUNDWATER Isopleths; Maximum Fluorescein, ug/L Plume Data1 50 - 500 500 - 5,000 5,000 - 50,000

> 50,000 5 - 50 Groundwater Elevation Contours Contours Other Than 10' Interval Ambient "Watertable" Contours 6/1/2007 (10' Interval) 20 5

Bar Graphs; Current Fluorescein, ug/day Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth Depth-Specific Data 11.3 11.9 12.6 12.8 Low river tide elevation for each screened interval, 6/1/2007.

Average tidal response for each screened interval (measured between 10/1/2006 and 11/31/2006).

5250 600 22 5.25 Water sample concentration of Fluorescein (ug/L) for each screened interval.

0 0.4 0

1.3 Containment Spray Sump Trench Probable Legacy Release Locations Terminated Connection To Storm Drain Footing /Storm Drain Exfiltration Inter-Structure Joint / Mud Mat Unit 1 West Fuel Pool Unit 2 Fuel Pool Carbon sampler concentration of Fluorescein (ug/day) for each screened interval.

1 1

Well ID Date Sample Collected Tracer Concentration (ppb)1 Well ID Date Sample Collected Tracer Concentration (ppb)

I-2 5/8/07 ND2 MW-52-64 5/24/07 ND MH-2 5/8/07 ND MW-52-122 5/24/07 ND MH-4 5/8/07 0.25 MW-52-162 5/24/07 ND MH-4A 5/8/07 ND MW-52-181 5/24/07 ND MH-5 5/8/07 0.17 MW-53-82 5/10/07 ND MH-6 5/9/07 14.4 MW-53-120 5/10/07 ND MW-30-69 6/12/07 2300 MW-54-37 6/1/07 ND MW-30-84 6/12/07 86 MW-54-58 6/1/07 ND MW-31-49 6/12/07 0.36 MW-54-123 6/1/07 0.050 MW-31-63 6/12/07 82.7 MW-54-173 6/1/07 0.040 MW-31-85 6/12/07 1.8 MW-54-190 6/1/07 0.039 MW-32-62 6/14/07 2.2 MW-55-24 5/9/07 0.056 MW-32-92 6/14/07 446 MW-55-35 5/9/07 0.099 MW-32-140 6/14/07 5.9 MW-55-54 5/9/07 0.13 MW-32-165 6/14/07 16.4 MW-56-53 5/8/07 ND MW-32-197 6/14/07 56 MW-56-83 5/8/07 ND MW-33 6/13/07 0.93 MW-57-11 5/9/07 0.11 MW-34 5/9/07 ND MW-57-20 5/9/07 ND MW-35 5/9/07 0.16 MW-57-45 5/9/07 ND MW-36-24 5/9/07 ND MW-58-26 5/10/07 ND MW-36-41 5/9/07 ND MW-58-65 5/10/07 0.15 MW-36-52 5/9/07 ND MW-59-32 5/10/07 ND MW-37-22 5/9/07 7.0 MW-59-45 5/10/07 ND MW-37-32 5/9/07 ND MW-59-68 5/10/07 ND MW-37-40 5/9/07 ND MW-60-35 6/1/07 ND MW-37-57 5/9/07 ND MW-60-53 6/1/07 ND MW-38 5/10/07 ND MW-60-72 6/1/07 ND MW-39-67 5/22/07 ND MW-60-135 6/1/07 ND MW-39-84 5/22/07 ND MW-60-176 6/1/07 ND MW-39-100 5/22/07 ND MW-62-18 5/17/07 ND MW-39-124 5/22/07 ND MW-62-37 5/17/07 ND MW-39-183 5/22/07 ND MW-62-53 6/1/07 ND MW-39-195 5/22/07 ND MW-62-71 6/1/07 ND MW-40-24 6/5/07 ND MW-62-92 6/1/07 ND MW-40-46 6/5/07 ND MW-62-138 6/1/07 ND MW-40-81 6/5/07 ND MW-62-182 6/1/07 ND MW-40-100 6/5/07 ND MW-63-18 5/18/07 ND MW-40-127 6/5/07 ND MW-63-29 5/18/07 ND MW-40-162 6/5/07 ND MW-63-50 6/1/07 ND MW-41-13 5/8/07 ND MW-63-93 6/1/07 ND MW-41-40 5/8/07 ND MW-63-112 6/1/07 ND MW-41-63 5/8/07 ND MW-63-121 6/1/07 ND MW-42-49 5/10/07 0.045 MW-63-163 6/1/07 ND MW-42-78 5/10/07 0.37 MW-63-174 6/1/07 ND MW-44-67 5/7/07 ND MW-65-48 5/8/07 ND MW-44-102 5/7/07 ND MW-65-80 5/8/07 ND MW-45-42 5/8/07 ND MW-66-21 MW-45-61 5/8/07 ND MW-66-36 MW-46 5/8/07 ND MW-66 (50)4 5/10/07 ND MW-47-56 5/8/07 ND MW-66 (115) 5/10/07 ND MW-47-80 5/8/07 ND MW-66 (135) 5/10/07 ND MW-48-23 5/10/07 ND MW-66 (190) 5/10/07 ND MW-48-38 5/10/07 ND MW-107 5/9/07 ND MW-49-26 5/9/07 0.22 MW-108 5/10/07 ND MW-49-42 5/9/07 ND MW-111 5/8/07 2.9 MW-49-65 5/9/07 ND RW-1 (97) 5/11/07 64 MW-50-42 5/9/07 ND RW-1 (118) 5/11/07 13.2 MW-50-66 5/9/07 ND CSS 5/11/07 ND MW-51-40 5/30/07 ND HR-1 5/9/07 ND MW-51-79 5/30/07 ND U1-CSS 5/9/07 ND MW-51-102 5/30/07 ND U1-NCD 5/11/07 2.2 MW-51-135 5/30/07 ND U1-SFDS 5/11/07 0.16 MW-51-163 5/30/07 ND U2-C1 5/9/07 0.11 MW-51-189 5/30/07 ND U3-3 5/8/07 ND MW-52-11 5/8/07 ND U3-4D 5/8/07 0.059 MW-52-18 5/24/07 ND U3-C1 5/8/07 0.11 MW-52-48 5/24/07 0.019

1) Shaded cells indicate sample collected via charcoal packets.

Concentrations are expressed as g/day.

2) ND: Not Detected. Water sample detection limit is 0.002 g/l.

Carbon sample elutant detection limit is 0.025 g/l.

3) NA: Not Applicable
4) Numbers in parenthesis indicate sample collection depths in an open borehole.

NA NA3 U3-Discharge Canal 5/8/07 ND Not Measured Not Detected (ND)

ND - 2.5 2.5 - 5 5 - 10 10 - 15 15 - 20 20 - 25 ND 1

3 7

12 17 23 Not Measured Not Detected (ND)

ND - 5 5 - 25 25 - 50 50 - 500 500 - 5,000 5,000 - 50,000 ND 4

8 32 250 700 25,000

?

Boring / Monitoring Installation Designation MW-30 Boring / Monitoring Installation

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

I-2 U3-3 U3-2 U3-1 RW-1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-108 MW-107 MW-58 MW-109 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1.89 1.57 0.09 0.15 0.95 0.38 0.16 1.15 1.13 0.21 0.14 1.62 1.57 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.1 0.1 1.6 0.2 0.3 1.3 0.11 0.11 0.17 0.27 0.37 0.23 0.17 2.14 1.36 0.44 0.15 2.08 1.39 2.36 2.04 0.55 2.36 1.65 2.04 1.26 1.88 1.29 1.72 1.72 0.36 0.17 0.34 0.15 1.36 0.63 0.62 0.63 1.72 2.04 1.42 2.29 1.63 0.18 2.91 1.93 0.48 0

0 3.12 0.15 3.12 3.12 3.12 0

0 0

0 0

0 2.49 2.12 1.9 1.5 1.2 1.2 1.2 1.2 1.3 0.63 0

13.1 10.3 42.8 8.2 6.7 8.2 35.4 30.7 1.1 1.1 1.1 12.46

-0.5 0.8 0.3 1.7 0.8 0.7 1.0 1.1 0.3 0.6 5.1 21.1 DRY 2.2 7.1 6.0 5.3 9.8 3.9 2.9 9.6 9.4 8.6 0.7 0.7 24.7 18.6 22.7 24.0 24.8 25.0 39.1 59.4 53.1 58.1 52.4 49.4 50.2 0.9 1.1 0.4 50.6 37.8 41.8 7.1 7.2 8.0 6.0 9.1 10.0 21.0 5.5 4.5 5.4 4.3 5.5 1.3 7.4 7.5 35.6 34.5 22.3 1.4 25.9 26.4 25.7 30.9 12.8 1.0 0.6 33.4 21.8 1.2 28.2 1.1 0.9 1.1 28.5 39.6 41.6 23.1 0.9 1.0 0.7 29.9 0.3 0.9 8.9 3.7 7.5 5.3 4.3 9.6 6.9 9.9 3.0 8.1 8.5 6.0 9.9 9.5 4.2 1.4 5.2 8.9 5.7 6.6 9.6 0.6 0.5 11.8 0.9 12.8 44.1 10.1 32.8 0.1

-0.5

-0.6 0.3

-0.1 0.0 116.8 55.0 0.1 storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Sign Concrete curb Concrete Concrete sidewalk Concrete curb Wooden curb Concrete sidewalk Concrete sidewalk Grass Concrete sidewalk Concrete sidewalk A/C UNIT Handicap ramp Concrete sidewalk A/C unit on concrete Concrete sidewalk Conc. sidewalk Concrete sidewalk Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt curb Asphalt sidewalk Shrubs Trans.

Asphalt Concrete sidewalk Concrete sidewalk Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Concrete sidewalk Conc. sidewalk Wooden walk Open grate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Sidewalk Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Concrete Retaining Wall Stone retaining wall Concrete sidewalk Gravel parking Gravel parking Asphalt parking Asphalt parking Concrete curb Concrete sidewalk curb pad Asphalt curb Asphalt curb Asphalt curb Grass Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Concrete sidewalk Overhead walkway Concrete curb Asphalt parking Concrete walk Asphalt parking Asphalt Asphalt Asphalt Wood walk Asphalt Concrete walk Concrete pier Courtyard Asphalt Rip-rap Sidewalk Concrete 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Concrete sidewalk Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRANSFER POOL STORAGE POOL STORAGE POOL FAILED FUEL AUX. POOL DISASSEMBLY POOL CASK LOAD POOL CASK WASH & DISASSEMBLY ISOLATION PIT 40 30 20 10 5

20 13 50 40 30 20 10 5

50 ND ND 0.187 ND 0.187 ND ND ND ND 0.225 ND 0.176 ND 0.247 ND ND ND ND ND ND 0.248 ND ND ND ND 0.255 4.61 2.25 0.467 0.819 0.573 0.2 9.75 4.86 34.2 0.346 0.754 11.3 0.502 264 9.1 0.23 10.8 5.40 4.32 11.2 11.3 297 302 11.9 107 44.8 119 34.9 1.59 17 0.71 30.1 276 26.8 2.42 24.0 3.51 15.4 4.32 0.28 55.2 2.63 3.57 11.3 0.76 1.85 13.1 9.04 12.5 3.08 13.2 40.6 4.06 3.91 5.76 1.25 0.297 1.89 2.08 0.282 0.591 0.326 0.679 0.761 0.849 0.593 0.278 0.311 0.183 0.7 0.208 0.281 0.78 9.61 0.960 3.43 1.71 4.15 0.701 0.369 0.508 0.888 0.856 0.55 0.471 0.462 0.76 1.28 0.541 0.892 0.313 0.578 0.473 0.805 0.538 0.339 0.392 1.65 0.424 0.223 0.763 1.05 1.86 0.393 0.261 1.11 10.5 0.755 0.761 ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 CB-B6A CB-B6 U3-CB-B5 U3-CB-B4 U3-CB-B4A U3-CB-B3 U3-CB-B3A U3-CB-B2A U3-CB-B2 U3-CB-B1 U3-CB-A2 U3-CB-A1 U3-MH-14 F5 U3-CB-A2A CB-B CB-E CB-F CB-1 (CB-G)

XX D2 U3-CB-B7 B5 U3-CB-B8 XX CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 U3-CB-A7 (U3-CB-11)

U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 (CB-24)

CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C U3-CB-E1 U3-CB-A6 U3-CB-A5 CB-A3A U3-CB-A3 U3-CB-A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 Transformer Yard PAB East Fuel Pool Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 U2-C1 HR-1 U3-C1 OUT-1 ALL EY WAY 2

3 4

UTILITY TUNNEL UTILITY TUNNEL 5

6 CSS CSS TRENCH H U D S O N R I V E R J:\\17869\\17869-10\\Figures\\GIS\\MXD Documents\\17869-10_8-1_Max_H3_v10.mxd LEGEND Data Notes:

1. H3 bounding isopleths / data represent upper bound values measured over both depth and time (available results for sample dates through 8/28/2007). As such, the "plume" is an overstatement of contaminant levels actually existing on-site at any time.
2. Tritium activity as high as 601,000 pCi/L, as measured on 11/22/2005 in MW-30 open borehole prior to multi-level well completion.
3. Tritium activity as high as 44,400 pCi/L, as measured on 6/27/2006 in MW-32 open borehole prior to multi-level well completion.
4. This upper bound Tritium concentration was obtained from the RW-1 open borehole during a pumping test.
5. Tritium activity as high as 337 pCi/L, as measured on 7/19/2006 in MW-52 open borehole prior to multi-level well completion.
6. Tritium activity as high as 16,000 pCi/L, as measured on 8/25/2006 in MW-55 open borehole prior to multi-level well completion.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey & Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".
2. Additional legend on Figure 1.3.

Plant North N

N 50 0

50 100 150 25 Feet Activity Data1 Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 41.0017869.10 1-4-2008 8.1 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 Note:

Groundwater contours developed from limited data available on 6/1/2007. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

BOUNDING UNIT 2 ACTIVITY ISOPLETHS 1

BOUNDING UNIT 2 ACTIVITY ISOPLETHS 1

Bar Graphs; Bounding H3, pCi/L No Depth-Specific Samples Not Detected (ND)

ND - 1,000 1,000 - 5,000 5,000 - 10,000 10,000 - 50,000 50,000 - 100,000 100,000 - 250,000

> 250,000 Isopleths; Bounding H3, pCi/L 5,000 - 10,000 10,000 - 50,000 50,000 - 100,000 100,000 - 250,000

> 250,000 ND 0.56 2.8 6.25 32.2 65 155 260 Vadose Zone Contaminant Transport Groundwater Elevation Contours Contours Other Than 10' Interval 5

Ambient "Watertable" Contours 6/1/2007 (10' Interval) 20 H3 data x1,000 pCi/L Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth Depth-Specific Data 11.3 11.9 12.6 12.8 Groundwater elevation at time of low river tide for each screened interval, 6/1/2007.

0 0.4 0

1.3 Average Tidal Response for each screened interval (measured between 10/1/2006 and 11/30/2006).

255.0 56.0 42.3 1.2 Activity of H3 (pCi/L x1000) for each screened Interval.

Well ID Date Sample Collected Bounding Tritium Concentration pCi/L Well ID Date Sample Collected Bounding Tritium Concentration pCi/L I-2 5/13/06 ND MW-54-37 7/31/07 888 MW-30-69 6/12/07 297,000 MW-54-58 5/3/07 760 MW-30-84 8/22/06 12,500 MW-54-123 5/3/07 1,110 MW-31-49 8/2/07 11,900 MW-54-144 7/31/07 1,890 MW-31-63 8/2/07 40,600 MW-54-173 7/31/07 2,080 MW-31-85 9/11/07 4,320 MW-54-190 7/31/07 2,250 MW-32-62 6/28/07 24,000 MW-55-24 6/28/07 3,080 MW-32-92 1/19/07 11,200 MW-55-35 11/9/06 9,040 MW-32-140 1/19/07 11,300 MW-55-54 11/9/06 13,100 MW-32-165 1/19/07 10,500 MW-56-53 1/4/07 780 MW-32-197 1/19/07 11,300 MW-56-83 6/22/07 1,850 MW-33 7/3/06 264,000 MW-57-11 6/22/07 4,610 MW-34 4/7/06 276,000 MW-57-20 6/22/07 1,650 MW-35 3/3/06 119,000 MW-57-45 8/24/06 4,060 MW-36-24 3/23/06 34,200 MW-58-26 7/31/07 856 MW-36-41 3/24/06 55,200 MW-58-65 1/5/07 550 MW-36-52 3/24/06 26,800 MW-59-32 6/21/07 467 MW-37-22 3/27/06 34,900 MW-59-45 6/21/07 754 MW-37-32 2/24/06 30,100 MW-59-68 7/31/07 819 MW-37-40 3/10/06 17,000 MW-60-35 7/27/07 761 MW-37-57 6/27/06 44,800 MW-60-53 7/27/07 ND MW-38 2/23/06 2,630 MW-60-72 7/27/07 ND MW-39-67 5/22/07 473 MW-60-135 7/27/07 392 MW-39-84 5/22/07 591 MW-60-154 7/27/07 462 MW-39-102 5/22/07 805 MW-60-176 7/27/07 849 MW-39-124 5/22/07 261 MW-61 MW-39-183 5/22/07 247 MW-62-18 7/26/07 508 MW-39-195 5/22/07 255 MW-62-37 5/17/07 297 MW-40-24 7/23/07 ND MW-62-53 5/10/07 393 MW-40-46 7/23/07 ND MW-62-71 5/10/07 502 MW-40-81 7/23/07 ND MW-62-92 5/10/07 700 MW-40-100 6/5/07 176 MW-62-138 7/26/07 538 MW-40-127 6/5/07 187 MW-62-182 5/10/07 541 MW-40-162 7/23/07 ND MW-63-18 5/18/07 230 MW-41-13 MW-63-34 7/30/07 280 MW-41-40 6/19/07 3,910 MW-63-50 5/15/07 326 MW-41-63 4/12/06 701 MW-63-93 5/15/07 281 MW-42-49 4/7/06 3,980 MW-63-112 5/15/07 424 MW-42-78 3/24/06 1,280 MW-63-121 5/15/07 311 MW-43-28 4/12/06 346 MW-63-163 5/15/07 578 MW-43-62 4/12/06 200 MW-63-174 5/15/07 593 MW-44-67 7/20/06 892 MW-65-48 1/4/07 208 MW-44-102 8/4/06 761 MW-65-80 1/4/07 183 MW-45-42 9/13/06 4,150 MW-66-21 7/30/07 3,570 MW-45-61 5/25/06 1,710 MW-66-36 7/30/07 9,100 MW-46 6/14/07 3,430 MW-66 MW-47-56 4/13/06 760 MW-67-39 8/31/2007 4860 MW-47-80 8/10/07 3,510 MW-67-105 8/31/2007 1860 MW-48-23 5/22/06 755 MW-67-173 8/31/2007 1050 MW-48-37 9/5/06 573 MW-67-219 8/31/2007 1250 MW-49-26 3/22/06 15,400 MW-67-276 8/31/2007 679 MW-49-42 3/22/06 11,300 MW-67-323 8/31/2007 313 MW-49-65 8/1/06 5,760 MW-67-340 8/31/2007 369 MW-50-42 3/22/06 9,750 MW-101 6/8/06 ND MW-50-66 5/19/06 10,802 MW-105 6/8/06 ND MW-51-40 7/24/07 223 MW-107 6/6/06 ND MW-51-79 7/24/07 ND MW-108 5/13/06 278 MW-51-102 7/24/07 ND MW-109 5/13/06 339 MW-51-135 7/24/07 ND MW-110 6/8/06 225 MW-51-163 7/24/07 ND MW-111 11/4/05 302,000 MW-51-189 5/30/07 187 RW-1 10/31/06 107,000 MW-52-11 8/6/07 ND U1-CSS 2/27/07 4,320 MW-52-18 8/6/07 ND U3-1 3/16/06 763 MW-52-48 8/6/07 ND U3-2 10/6/05 960 MW-52-64 8/6/07 ND U3-3 11/10/05 471 MW-52-118 8/6/07 ND U3-4D 6/22/06 710 MW-52-162 5/24/07 282 U3-4S MW-52-181 5/24/07 248 U3-T1 10/7/05 1,590 MW-53-82 8/23/06 13,200 U3-T2 1/6/06 2,420 MW-53-120 6/22/07 9,610 No Sample No Sample No Sample No Sample Note: Illustration of contaminant plume is a schematic representation only. In reality, the geologic bedrock formation is over 99% solid, crystalline rock, with the contaminated water contained only in the remaining (less than 1%) interstitial space (i.e. fractures).

?

Boring / Monitoring Installation Designation MW-30 Boring / Monitoring Installation Containment Spray Sump Pipe Trench Probable Legacy Release Locations Terminated Connection To Storm Drain Footing / Storm Drain Exfiltration Inter Structure Joint / Mud Mat Unit 1 West Fuel Pool Unit 2 Fuel Pool

G G

G G

G G

G G

G G

G

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' I-2 U3-3 U3-2 U3-1 RW-1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-108 MW-107 MW-58 MW-109 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1.89 1.57 0.09 0.15 0.95 0.38 0.16 1.15 1.13 0.21 0.14 1.62 1.57 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.1 0.1 1.6 0.2 0.3 1.3 0.11 0.11 0.17 0.27 0.37 0.23 0.17 2.14 1.36 0.44 0.15 2.08 1.39 2.36 2.04 0.55 2.36 1.65 2.04 1.26 1.88 1.29 1.72 1.72 0.36 0.17 0.34 0.15 1.36 0.63 0.62 0.63 1.72 2.04 1.42 2.29 1.63 0.18 2.91 1.93 0.48 0

0 3.12 0.15 3.12 3.12 3.12 0

0 0

0 0

0 2.49 2.12 1.9 1.5 1.2 1.2 1.2 1.2 1.3 0.63 0

13.1 10.3 42.8 8.2 6.7 8.2 35.4 30.7 1.1 1.1 1.1 12.46

-0.5 0.8 0.3 1.7 0.8 0.7 1.0 1.1 0.3 0.6 5.1 21.1 DRY 2.2 7.1 6.0 5.3 9.8 3.9 2.9 9.6 9.4 8.6 0.7 0.7 24.7 18.6 22.7 24.0 24.8 25.0 39.1 59.4 53.1 58.1 52.4 49.4 50.2 0.9 1.1 0.4 50.6 37.8 41.8 7.1 7.2 8.0 6.0 9.1 10.0 21.0 5.5 4.5 5.4 4.3 5.5 1.3 7.4 7.5 35.6 34.5 22.3 1.4 25.9 26.4 25.7 30.9 12.8 1.0 0.6 33.4 21.8 1.2 28.2 1.1 0.9 1.1 28.5 39.6 41.6 23.1 0.9 1.0 0.7 29.9 0.3 0.9 8.9 3.7 7.5 5.3 4.3 9.6 6.9 9.9 3.0 8.1 8.5 6.0 9.9 9.5 4.2 1.4 5.2 8.9 5.7 6.6 9.6 0.6 0.5 11.8 0.9 12.8 44.1 10.1 32.8 0.1

-0.5

-0.6 0.3

-0.1 0.0 116.8 55.0 0.1 storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open grate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Concrete Retaining Wall Stone retaining wall Gravel parking Gravel parking Asphalt parking Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt curb Grass Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRANSFER POOL STORAGE POOL STORAGE POOL FAILED FUEL AUX. POOL DISASSEMBLY POOL CASK LOAD POOL CASK WASH & DISASSEMBLY ISOLATION PIT 40 30 20 10 5

20 13 50 40 30 20 10 5

50 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 1.3 1.3 46.0 4.8 1.2 19.5 0.8 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 18.6 ND ND 5.0 ND ND ND ND ND ND ND ND ND 1.1 ND ND 7.0 ND ND ND ND 31.0 37.0 1.3 6.2 1.4 0.6 1.7 7.1 3.5 ND 1.5 1.6 2.5 110 18.3 23.3 24.4 18.9 40.4 22.8 2.7 7.0 2.3 26.8 12.5 1.8 1.0 1.3 2.2 19.5 18.4 3.6 23.1 2.7 18.8 25.6 20.8 21.9 19.2 20.9 2.5 0.7 0.9 0.7 0.8 MH-4 MH-4A MH-5 MH-6 MH-2 CB-B6A CB-B6 U3-CB-B5 U3-CB-B4 U3-CB-B4A U3-CB-B3 U3-CB-B3A U3-CB-B2A U3-CB-B2 U3-CB-B1 U3-CB-A2 U3-CB-A1 U3-MH-14 F5 U3-CB-A2A CB-B CB-E CB-F CB-1 (CB-G)

XX D2 U3-CB-B7 B5 U3-CB-B8 XX CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 U3-CB-A7 (U3-CB-11)

U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 (CB-24)

CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C U3-CB-E1 U3-CB-A6 U3-CB-A5 CB-A3A U3-CB-A3 U3-CB-A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB EAST FUEL POOL STORAGE POOL FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 U2-C1 HR-1 U3-C1 OUT-1 ALL EY WAY TRANSFER POOL SPENT FUEL POOL COMPLEX 6

6 6

6 6

5 33' WATER 3

2 UTILITY TUNNEL UTILITY TUNNEL 4

2 6

6 5

5 5

5 5

5 5

CSS CSS TRENCH 6

H U D S O N R I V E R I:\\17869\\17869-10\\Figures\\GIS\\MXD Documents\\17869-10_8-2_Max_Sr_v10.mxd LEGEND Data Notes:

1. Sr-90 "bounding isopleths" / data represent upper bound values measured over both depth and time (available results for sample dates through 8/28/2007). As such, the "plume" is an overstatement of contaminant levels actually existing on-site at any time.
2. Sr-90 activity at MW-111 and MW-33 may be due to desorption of residual Sr-90 from backfill used in the Transformer Yard.
3. Sr-90 only detected in MW-30 during pumping test of RW-1 on 11/29/06.
4. A Sr-90 value of 0.9 was measured on 5/24/2006 in MW-31 open borehole.
5. Three discrete isopleths have been drawn around MW-39, 41, and 43 given measured concentrations greater than 2 pCi/L. It is expected that similar concentrations exist at other locations along the legacy piping alignment in addition to the locations shown.
6. The low Sr-90 concentrations measured in these wells are consistent with that expected due to residual levels remaining as the legacy plume has attenuated over time.

Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 41.0017869.10 1-4-2008 8.2 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 Note:

Groundwater contours developed from limited data available on 6/1/2007. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey & Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".
2. Additional legend on Figure 1.3.

Groundwater Elevation Contours BOUNDING UNIT 1 ACTIVITY ISOPLETHS 1

BOUNDING UNIT 1 ACTIVITY ISOPLETHS 1

Activity Data1 2 - 4 4 - 8 8 - 25 25 - 75

> 75 Isopleths; Bounding Sr-90, pCi/L Contours Other Than 10' Interval Ambient "Watertable" Contours 6/1/2007 (10' Interval) 20 5

Screened in Soil Screened in Bedrock 11.3 11.9 12.6 12.8 Groundwater elevation at time of low river tide for each screened interval, 6/1/2007.

Multiple Screened Intervals w/ Depth Depth-Specific Data 0

0.4 0

1.3 Average Tidal Response for each screened interval (measured between 10/1/06 and 11/30/06).

1.6 20.2 6.0 1.3 Activity of Sr90 (pCi/L) for each screened interval.

Bar Graphs; Bounding Sr-90, pCi/L No Depth-Specific Samples Not Detected (ND)

ND - 1.0 1.0 - 2.0 2.0 - 4.0 4.0 - 8.0 8.0 - 25 25 - 75

> 75 ND 0.74 1.7 2.86 5.5 16.1 40.4 110 Well ID Date Sample Collected Bounding Strontium 90 Concentration pCi/L Well ID Date Sample Collected Bounding Strontium 90 Concentration pCi/L I-2 5/13/06 ND MW-54-37 5/3/07 12.5 MW-30-69 11/29/06 2.5 MW-54-58 5/3/07 2.2 MW-30-84 1/17/07 ND MW-54-123 5/3/07 21.9 MW-31-49 8/2/07 ND MW-54-144 7/31/07 19.2 MW-31-63 8/2/07 ND MW-54-173 5/3/07 20.9 MW-31-85 8/2/07 ND MW-54-190 5/3/07 19.5 MW-32-62 8/13/07 ND MW-55-24 8/2/07 23.1 MW-32-92 8/13/07 ND MW-55-35 11/9/06 40.4 MW-32-140 8/13/07 ND MW-55-54 11/9/06 22.8 MW-32-165 8/13/07 ND MW-56-53 8/10/07 ND MW-32-197 8/13/07 ND MW-56-83 9/8/06 2.7 MW-33 6/7/06 0.7 MW-57-11 6/22/07 46.0 MW-34 8/3/07 ND MW-57-20 6/22/07 2.0 MW-35 8/3/07 ND MW-57-45 8/24/06 18.8 MW-36-24 4/5/06 1.6 MW-58-26 7/31/07 1.0 MW-36-41 4/5/06 3.5 MW-58-65 7/31/07 ND MW-36-52 3/24/06 5.0 MW-59-32 7/31/07 ND MW-37-22 8/7/07 18.3 MW-59-45 7/31/07 ND MW-37-32 8/7/07 18.9 MW-59-68 7/31/07 ND MW-37-40 6/27/07 24.4 MW-60-35 7/27/07 ND MW-37-57 8/7/07 23.3 MW-60-53 7/27/07 ND MW-38 2/12/07 ND MW-60-72 7/27/07 ND MW-39-67 8/7/07 4.8 MW-60-135 7/27/07 ND MW-39-84 5/22/07 1.7 MW-60-154 7/27/07 ND MW-39-102 5/22/07 1.3 MW-60-176 7/27/07 ND MW-39-124 8/7/07 ND MW-61 MW-39-183 8/7/07 ND MW-62-18 7/26/07 ND MW-39-195 5/22/07 1.3 MW-62-37 7/26/07 ND MW-40-24 6/5/07 ND MW-62-53 7/26/07 ND MW-40-46 6/5/07 ND MW-62-71 7/26/07 ND MW-40-81 6/5/07 ND MW-62-92 7/26/07 ND MW-40-100 6/5/07 ND MW-62-138 5/10/07 0.8 MW-40-127 6/5/07 ND MW-62-182 7/26/07 ND MW-40-162 6/5/07 ND MW-63-18 7/30/07 ND MW-41-13 MW-63-29 7/30/07 ND MW-41-40 7/14/06 7.0 MW-63-50 7/25/07 ND MW-41-63 6/20/07 7.1 MW-63-93 7/25/07 ND MW-42-49 4/7/06 110 MW-63-112 7/25/07 ND MW-42-78 8/17/07 ND MW-63-121 7/25/07 ND MW-43-28 5/25/06 2.7 MW-63-163 7/25/07 ND MW-43-62 6/12/06 1.3 MW-63-174 7/25/07 ND MW-44-67 5/24/06 0.7 MW-65-48 1/4/07 ND MW-44-102 8/14/07 ND MW-65-80 1/4/07 ND MW-45-42 4/4/06 1.0 MW-66-21 7/30/07 1.8 MW-45-61 11/13/06 1.7 MW-66-36 7/30/07 6.2 MW-46 4/12/06 0.6 MW-66 MW-47-56 4/13/06 2.3 MW-67-39 8/31/2007 18.6 MW-47-80 8/10/07 3.6 MW-67-105 8/31/2007 1.1 MW-48-23 2/9/07 ND MW-67-173 8/31/2007 ND MW-48-37 2/9/07 ND MW-67-219 8/31/2007 ND MW-49-26 3/22/06 18.4 MW-67-276 8/31/2007 ND MW-49-42 8/9/07 25.6 MW-67-323 8/31/2007 ND MW-49-65 8/9/07 20.8 MW-67-340 8/31/2007 ND MW-50-42 5/19/06 19.5 MW-101 6/8/06 ND MW-50-66 7/26/07 31.0 MW-105 6/8/06 ND MW-51-40 7/24/07 ND MW-107 6/6/06 ND MW-51-79 7/24/07 ND MW-108 5/13/06 ND MW-51-102 7/24/07 ND MW-109 5/13/06 ND MW-51-135 7/24/07 ND MW-110 6/8/06 ND MW-51-163 7/24/07 ND MW-111 5/17/06 2.5 MW-51-189 7/24/07 ND RW-1 11/3/06 ND MW-52-11 8/6/07 ND U1-CSS 8/6/07 26.8 MW-52-18 8/6/07 ND U3-1 6/22/06 ND MW-52-48 8/6/07 ND U3-2 6/22/06 1.4 MW-52-64 8/6/07 ND U3-3 6/22/06 ND MW-52-118 8/6/07 ND U3-4D 6/22/06 ND MW-52-162 8/6/07 ND U3-4S MW-52-181 8/6/07 ND U3-T1 5/26/06 1.3 MW-53-82 8/30/06 6.7 U3-T2 5/26/06 1.5 MW-53-120 8/9/07 37.0 No Sample No Sample No Sample No Sample Note: Illustration of contaminant plume is a schematic representation only. In reality, the geologic bedrock formation is over 99% solid, crystalline rock, with the contaminated water contained only in the remaining (less than 1%) interstitial space (i.e. fractures).

?

Boring / Monitoring Installation Designation MW-30 Boring / Monitoring Installation Probable Legacy Release Locations Footing / Storm Drain Exfiltration Inter-Structure Joint / Mud Mat Terminated Connection To Storm Drain Containment Spray Sump Trench Unit 1 West Fuel Pool Unit 2 Fuel Pool Vadose Zone Contaminant Transport

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

I-2 U3-3 U3-2 U3-1 RW-1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-108 MW-107 MW-58 MW-109 storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open grate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Concrete Retaining Wall Stone retaining wall Gravel parking Gravel parking Gravel parking Asphalt parking Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt curb Grass Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRANSFER POOL STORAGE POOL STORAGE POOL FAILED FUEL AUX. POOL DISASSEMBLY POOL CASK LOAD POOL CASK WASH & DISASSEMBLY ISOLATION PIT 40 30 20 10 5

20 13 50 40 30 20 10 5

50 ND 36.7 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 22.4 ND ND ND ND ND ND ND 29.1 54.3 ND ND 34.1 ND ND ND ND ND ND ND 56.5 ND 64.1 48.7 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 27.1 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 36.6 ND 5120 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 194 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 13.6 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 46.6 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 7.2 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 7.9 ND ND ND ND ND ND ND ND ND ND ND ND ND ND 88.3 72.7 115 152 294 199 149 11.8 2.7 35.4 4.2 ND ND ND ND ND 4460 3130 102000 ND ND 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1.89 1.57 0.09 0.15 0.95 0.38 0.16 1.15 1.13 0.21 0.14 1.62 1.57 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.1 0.1 1.6 0.2 0.3 1.3 0.11 0.11 0.17 0.27 0.37 0.23 0.17 2.14 1.36 0.44 0.15 2.08 1.39 2.36 2.04 0.55 2.36 1.65 2.04 1.26 1.88 1.29 1.72 1.72 0.36 0.17 0.34 0.15 1.36 0.63 0.62 0.63 1.72 2.04 1.42 2.29 1.63 0.18 2.91 1.93 0.48 0

0 3.12 0.15 3.12 3.12 3.12 0

0 0

0 0

1.3 2.49 2.12 2.29 1.97 1.76 1.69 1.78 1.74 1.8 0.63 13.1 10.3 42.8 8.2 6.7 8.3 35.3 30.7 0.68 0.68 0.68 8.8

-0.77 0.19

-0.305 0.7326

-1.0318

-0.208

-0.0301

-0.0067

-0.645

-1.6283 5.0 21 2

7.1 5.9 5.3 9.8 3.8 2.9 9.6 9.3 8.6 0.6 5.25 24.7 18.6 22.7 24.0 24.8 25.0 39.1 59.4 53.1 58.1 52.4 49.4 50.2 0.79 0.78 0.67 50.6 37.8 41.8 7

7 8

6 9

10 21 5.4 4.4 5.4 4.2 5.5 1.3 7.4 7.3 35.6 34.5 22.3 0.97 25.9 26.4 25.6 30.9 12.8 1.04 0.61 33.4 21.8 0.85 28.2 1.0 0.83 0.68 28.5 39.6 41.6 23.1 0.43 0.68 0.65 29.9 0.31 0.89 8.9 3.6 8.3 5.3 4.2 9.6 6.9 9.9 2.8 8.1 8.4 6.04 9.9 9.5 4.1 1.3 5.1 8.8 5.6 6.6 9.6 0.5 0.11 11.8 0.69 12.8 44.1 10.1 32.7

-0.07

-0.61

-0.77

-0.12

-0.13

-0.17 116.8 54.95

-0.004 ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 CB-B6A CB-B6 U3-CB-B5 U3-CB-B4 U3-CB-B4A U3-CB-B3 U3-CB-B3A U3-CB-B2A U3-CB-B2 U3-CB-B1 U3-CB-A2 U3-CB-A1 U3-MH-14 F5 U3-CB-A2A CB-B CB-E CB-F CB-1 (CB-G)

XX D2 U3-CB-B7 B5 U3-CB-B8 XX CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 U3-CB-A7 (U3-CB-11)

U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 (CB-24)

CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C U3-CB-E1 U3-CB-A6 U3-CB-A5 CB-A3A U3-CB-A3 U3-CB-A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 U2-C1 HR-1 U3-C1 OUT-1 Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co UTILITY TUNNEL UTILITY TUNNEL 2

2 2

2 CSS CSS TRENCH H U D S O N R I V E R J:\\17,000-18,999\\17869\\17869-10.DW\\Figures\\GIS\\MXD Documents\\17869-10_8-3_Max_Cs-Co-Ni_v10.mxd Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 41.0017869.10 1-4-2008 8.3 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 BOUNDING CESIUM (Cs), COBALT (Co), AND NICKEL (Ni) ACTIVITY IN GROUNDWATER 1

LEGEND Data Notes:

1. Cesium, Cobalt, and Nickel bounding data represent upper bound values measured over both depth and time (available results for sample dates through 8/28/2007). As such, these data are an overstatement of contaminant levels actually existing on-site at any time.
2. Bounding values for Cs in MW-30 and MW-31 were measured just after the RW-1 pumping test.

Note:

Contours developed from limited data available on 6/1/2007. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey & Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".
2. Additional legend on Figure 1.3.

Groundwater Elevation Contours Contours Other Than 10' Interval Ambient "Watertable" Contours 6/1/2007 (10' Interval) 20 5

11.3 11.9 12.6 12.8 Groundwater elevation at time of low river tide for each screened interval, 6/1/2007.

0 0.4 0

1.3 Average tidal response for each screened interval (measured between 10/1/2006 anf 11/30/2006).

Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth Depth-Specific Data 6000 836 294 Activity of Cs 137 (pCi/L) for each screened interval.

37 508 250 194 4

526 207 49 20 Activity of Co 60 (pCi/L) for each screened interval.

Activity of Ni 63 (pCi/L) for each screened interval.

Cesium Data1 Bounding Cs, pCi/L Cobalt Data1 Bounding Co, pCi/L Nickel Data 1 Bounding Ni, pCi/L Not Detected (ND)

ND - 10 10 - 50 50 - 500 500 - 1,000 1,000 - 5,000

> 5,000 No Depth-Specific Samples ND 4.2 37 294 836 4460 6000 Not Detected (ND)

ND - 25 25 - 100 100 - 200 200 - 300 300 - 500

> 500 No Depth-Specific Samples ND 4

83 194 250 350 508 Not Detected (ND)

ND - 12 12 - 25 25 - 50 50 - 100 100 - 250 250 - 500

> 500 No Depth-Specific Samples ND 4

20 49 54 207 300 526 BOUNDING CESIUM (Cs), COBALT (Co),

AND NICKEL (Ni)

ACTIVITY IN GROUNDWATER 1

Containment Spray Sump Trench Probable Legacy Release Locations Terminated Connection To Storm Drain Footing / Storm Drain Exfiltration Inter-Structure Joint / Mud Mat Unit 1 West Fuel Pool Unit 2 Fuel Pool Well ID Date Sample Collected Bounding Cs 137 pCi/L Date Sample Collected Bounding Co 60 pCi/L Date Sample Collected Bounding Ni 63 pCi/L Well ID Date Sample Collected Bounding Cs 137 pCi/L Date Sample Collected Bounding Co 60 pCi/L Date Sample Collected Bounding Ni 63 pCi/L I-2 5/13/06 ND MW-54-37 7/31/07 ND 7/31/07 ND 7/31/07 ND MW-30-69 11/29/06 3,130 7/25/07 ND 6/12/07 ND MW-54-58 7/31/07 ND 7/31/07 ND 7/31/07 ND MW-30-84 11/29/06 294 7/25/07 ND 6/12/07 ND MW-54-123 5/3/07 4.2 7/31/07 ND 7/31/07 ND MW-31-49 8/2/07 88.3 8/2/07 ND 6/12/07 ND MW-54-144 7/31/07 ND 7/31/07 ND 7/31/07 ND MW-31-63 11/27/06 199 8/2/07 ND 6/12/07 ND MW-54-173 7/31/07 ND 7/31/07 ND 7/31/07 ND MW-31-85 11/27/06 152 8/2/07 ND 6/12/07 ND MW-54-190 7/31/07 ND 7/31/07 ND 7/31/07 ND MW-32-62 8/13/07 ND 8/13/07 ND MW-55-24 8/2/07 ND 8/2/07 ND 8/2/07 ND MW-32-92 8/13/07 ND 8/13/07 ND MW-55-35 8/2/07 ND 8/2/07 ND 8/2/07 ND MW-32-140 8/13/07 ND 8/13/07 ND MW-55-54 8/2/07 ND 8/2/07 ND 8/2/07 ND MW-32-165 8/13/07 ND 8/13/07 ND MW-56-53 1/4/07 13.6 8/10/07 ND 6/26/07 ND MW-32-197 8/13/07 ND 8/13/07 ND MW-56-83 1/4/07 11.8 8/10/07 ND 6/22/07 ND MW-33 8/3/07 ND 8/3/07 ND 6/15/07 ND MW-57-11 8/6/07 ND 8/6/07 ND 6/22/07 22.4 MW-34 8/3/07 ND 8/3/07 ND MW-57-20 8/6/07 ND 8/6/07 ND 8/6/07 ND MW-35 6/15/07 46.6 8/3/07 ND 6/15/07 ND MW-57-45 8/6/07 ND 8/6/07 ND 8/6/07 ND MW-36-24 8/8/07 ND 8/8/07 ND 3/23/06 64.1 MW-58-26 11/16/06 72.7 7/31/07 ND 6/21/07 ND MW-36-41 6/27/07 ND 6/27/07 ND 3/24/06 48.7 MW-58-65 7/31/07 ND 7/31/07 ND 6/21/07 ND MW-36-52 8/8/07 ND 8/8/07 ND 8/8/07 ND MW-59-32 7/31/07 ND 7/31/07 ND 6/21/07 ND MW-37-22 8/7/07 ND 8/7/07 ND 3/27/06 54.3 MW-59-45 1/5/07 149 7/31/07 ND 6/21/07 ND MW-37-32 8/7/07 ND 8/7/07 ND 2/28/06 34.1 MW-59-68 11/16/06 115 7/31/07 ND 6/21/07 ND MW-37-40 8/7/07 ND 8/7/07 ND 2/28/06 56.5 MW-60-35 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-37-57 8/7/07 ND 8/7/07 ND 2/28/06 29.1 MW-60-53 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-38 2/12/07 2.7 8/16/07 ND 8/7/06 ND MW-60-72 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-39-67 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-60-135 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-39-84 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-60-154 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-39-100 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-60-176 7/27/07 ND 7/27/07 ND 5/8/07 ND MW-39-124 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-61 MW-39-183 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-62-18 7/26/07 ND 7/26/07 ND 5/17/07 ND MW-39-195 8/7/07 ND 8/7/07 ND 5/22/07 ND MW-62-37 7/26/07 ND 7/26/07 ND 5/17/07 ND MW-40-27 7/23/07 ND 7/23/07 ND MW-62-53 7/26/07 ND 7/26/07 ND 5/10/07 ND MW-40-46 7/23/07 ND 7/23/07 ND MW-62-71 7/26/07 ND 7/26/07 ND 5/10/07 ND MW-40-81 7/23/07 ND 7/23/07 ND MW-62-92 7/26/07 ND 7/26/07 ND 5/10/07 ND MW-40-102 7/23/07 ND 7/23/07 ND MW-62-138 7/26/07 ND 7/26/07 ND 5/10/07 ND MW-40-127 7/23/07 ND 7/23/07 ND MW-62-182 7/26/07 ND 7/26/07 ND 5/10/07 ND MW-40-162 7/23/07 ND 7/23/07 ND MW-63-18 7/30/07 ND 7/30/07 ND 5/18/07 ND MW-41-13 MW-63-34 7/30/07 ND N/A N/A 5/18/07 N/A MW-41-40 8/14/07 ND 8/14/07 ND 6/19/07 ND MW-63-50 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-41-63 8/14/07 ND 8/14/07 ND 6/20/07 ND MW-63-93 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-42-49 3/23/06 102,000 3/23/06 194 4/7/06 5,120 MW-63-112 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-42-78 3/24/06 4,460 8/17/07 ND 4/7/06 36.6 MW-63-121 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-43-28 8/13/07 ND 8/13/07 ND 6/18/07 ND MW-63-163 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-43-62 8/13/07 ND 8/13/07 ND 6/19/07 ND MW-63-174 7/25/07 ND 7/25/07 ND 5/15/07 ND MW-44-67 7/20/06 35.4 8/14/07 ND MW-65-48 1/4/07 ND 1/4/07 ND 1/4/07 ND MW-44-102 8/14/07 ND 8/14/07 ND 6/19/07 ND MW-65-80 1/4/07 ND 1/4/07 ND 1/4/07 ND MW-45-42 8/15/07 ND 8/15/07 ND 6/21/07 ND MW-66-21 7/30/07 ND 7/30/07 ND MW-45-61 8/15/07 ND 8/15/07 ND 6/21/07 ND MW-66-36 7/30/07 ND 7/30/07 ND MW-46 8/1/07 ND 8/1/07 ND 6/19/07 ND MW-66 MW-47-56 8/10/07 ND 8/10/07 ND 6/20/07 ND MW-67-39 8/31/07 ND 8/31/07 ND MW-47-80 8/10/07 ND 8/10/07 ND 6/19/07 ND MW-67-105 8/31/07 ND 8/31/07 ND MW-48-23 8/16/07 ND 8/16/07 ND 6/9/06 ND MW-67-173 8/31/07 ND 8/31/07 ND MW-48-37 8/16/07 ND 8/16/07 ND 6/9/06 ND MW-67-219 8/31/07 ND 8/31/07 ND MW-49-26 8/9/07 ND 8/9/07 ND 8/1/06 36.7 MW-67-276 8/31/07 ND 8/31/07 ND MW-49-42 8/9/07 ND 8/9/07 ND 8/9/07 ND MW-67-323 8/31/07 ND 8/31/07 ND MW-49-65 8/9/07 ND 8/9/07 ND 8/9/07 ND MW-67-340 8/31/07 ND 8/31/07 ND MW-50-42 11/15/06 7.2 7/26/07 ND 7/26/07 ND MW-101 6/8/06 ND 6/8/06 ND MW-50-66 7/26/07 ND 7/26/07 ND 7/26/07 ND MW-105 6/8/06 ND 6/8/06 ND MW-51-40 7/24/07 ND 7/24/07 ND MW-107 7/23/07 ND 7/23/07 ND MW-51-79 7/24/07 ND 7/24/07 ND MW-108 5/13/06 ND 5/13/06 ND MW-51-104 7/24/07 ND 7/24/07 ND MW-109 5/13/06 ND 5/13/06 ND MW-51-135 7/24/07 ND 7/24/07 ND MW-110 6/8/06 ND 6/8/06 ND MW-51-163 7/24/07 ND 7/24/07 ND MW-111 8/3/07 ND 8/3/07 ND 6/15/07 ND MW-51-189 7/24/07 ND 7/24/07 ND RW-1 11/3/06 ND 11/3/06 ND MW-52-11 8/6/07 ND 8/6/07 ND 6/20/07 ND U1-CSS 8/6/07 ND 8/6/07 ND 6/13/07 ND MW-52-18 8/6/07 ND 8/6/07 ND 5/24/07 ND U3-1 6/22/06 ND 6/22/06 ND MW-52-48 8/6/07 ND 8/6/07 ND 5/24/07 ND U3-2 6/22/06 ND 6/22/06 ND MW-52-64 8/6/07 ND 8/6/07 ND 5/24/07 ND U3-3 6/22/06 ND 6/22/06 ND MW-52-122 8/6/07 ND 8/6/07 ND 5/24/07 N/A U3-4D 6/22/06 ND 6/22/06 ND MW-52-162 8/6/07 ND 8/6/07 ND 5/24/07 ND U3-4S MW-52-181 8/6/07 ND 8/6/07 ND 5/24/07 ND U3-T1 8/1/07 ND 8/1/07 ND 6/12/07 ND MW-53-82 8/9/07 ND 8/9/07 ND 8/9/07 ND U3-T2 8/1/07 ND 8/1/07 ND 6/12/07 ND MW-53-120 6/22/07 7.9 8/9/07 ND 11/9/06 27.1

1. Not Analyzed
2. Result from a composite sample NA1 NA NA NA NA NA 7/10/06 2 ND 6/20/06 2 ND No Sample No Sample No Sample No Sample NA NA

?

Boring / Monitoring Installation Designation MW-30 Boring / Monitoring Installation