ML12338A579

From kanterella
Jump to navigation Jump to search
Official Exhibit - ENT000273-00-BD01 - Transmittal of the Final Exercise Report for Indian Point Energy Center Radiological Emergency Preparedness Plume Pathway Exercise Conducted on 09/14/2010
ML12338A579
Person / Time
Site: Indian Point  
Issue date: 12/05/2011
From: Canton L
US Dept of Homeland Security, Federal Emergency Management Agency
To: Tailleart D
Atomic Safety and Licensing Board Panel, Office of Nuclear Security and Incident Response
SECY RAS
References
RAS 22118, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12338A579 (103)


Text

ENT000273 Submitted: March 29, 2012 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of:

Entergy Nuclear Operations, Inc.

(Indian Point Nuclear Generating Units 2 and 3)

ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #:

Identified:

Admitted:

Withdrawn:

Rejected:

Stricken:

Other:

ENT000273-00-BD01 10/15/2012 10/15/2012 c,,,,tJ"oR REGlJ<..q" U.S. Department of Bomelaud Security Region n

~'.

t:

~

0

~

~

Jacob K. Javits Federal Office BuiJding 26 Federal Plaza, Room 1311

~

i

........ 1-0-

Mr. Don Tailleart Office of Nuclear Security and Incident Response U.S. Nuclear Regulatory Commission 11555 Rockville Pike, Mail Stop DB46M Rockville, MD 20852

Dear Mr. Tailleart:

e FWA December 5, 2011 Enclosed please find a copy of the Final Exercise Report for the Indian Point Energy Center radiological emergency preparedness Plume Pathway Exercise conducted on September 14, 2010.

This report, dated November 30, 2011, includes a number of related out-of-sequence drills and demonstrations that were completed after the plume phase exercise, including into 2011.

The State of New York and local emergency response organizations successfully demonstrated the capabilities to implement their off-site radiological emergency response plans and procedures, based on the evaluation of this exercise by the Regional Assistance Committee and a team of Federal evaluators. There were no deficiencies and no new Areas Requiring Corrective Actions (ARCAs). Seven prior ARCA's were corrected; two outstanding prior ARCAs remain unresolved.

Therefore, we fmd that State and local preparedness is adequate to protect the health and safety of the public living in the vicinity of the Indian Point Energy Center and that there is reasonable assurance that appropriate measures can be taken offsite in the event ofa radiological emergency.

If you have any questions regarding this matter, please contact Rebecca Thomson, Chair of the R. II Regional Assistance Committee at (212) 680-8509.

Sincerely yours,

~~.,

~ynnCanton Regional Administrator cc:

Vanessa Quinn, Chief, Radiological Emergency Preparedness Branch, FEMA HQ.

NRC HQ Document Control Desk (w/copy)

Enclosure www.dbs.gov.PH: (212) 680-3600

FINAL EXERCISE REPORT INDIAN POINT ENERGY CENTER FULL SCALE EXERCISE Licensee:

Entergy Exercise Date: September 14,2010 Report Date:

Nov. 30,2011 u.s. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY REGION II 26 Federal Plaza New York, New York 10278

2.2 PUTNAM OUNTY............................................................................................................ 31 2.2.1 Putnam County Emergency Operations Center.................................................................. 31 2.2.2 Putnam County Warning Point........................................................................................... 31 2.2.3 Putnam County Accident Assessment................................................................................ 32 2.2.4 Putnam County Field Monitoring Team A......................................................................... 32 2.2.5 Putnam County Field Monitoring Team B......................................................................... 32 2.2.6 Putnam County - General Population Reception Center (George Fisher Middle School May 25, 2010)..................................................................................................................... 33 2.2.7 Putnam County - General Population Reception Center Reception Center (Carmel High School-September 2,2009 and May 24, 2010)................................................................. 33 2.2.8 Putnam County - Medical MS-l Drill Putnam County Hospital/Carmel Ambulance May 12, 2010)..................................................................................................................... 35 2.2.9 Putnam County - Traffic and Access Control 1................................................................. 35 2.2.10 Putnam County - Traffic and Access Control 2................................................................. 35 2.2.11 Putnam County - Emergency Worker PMC (Carmel Fire Dept, Nov. 16,2010)................ 36 2.3 ROCKLAND COUNTy..................................................................................................... 37 2.3.1 Rockland County Emergency Operations Center................................................................ 37 2.3.2 Rockland County Warning Point......................................................................................... 37 2.3.3 Rockland County Accident Assessment.............................................................................. 37 2.3.4 Rockland County Field Monitoring Team 1........................................................................ 38 2.3.5 Rockland County Field Monitoring Team 2........................................................................ 38 2.3.6 Rockland County - Special Population Bus Company Interviews..................................... 38 (Chestnut Ridge - January 11,2010; Student Bus January 7, 2010) 2.3.7 Rockland County - School Bus Company Interviews....................................................... 39 (Chestnut Ridge -January 11,2010; Student Bus January 7,2010) 2.3. 8 Rockland County - General Population Bus Company Interviews................................... 39 (Chestnut Ridge -January 11,2010; Student Bus January 7,2010).................................. 39 2.3.9 Rockland County - School Interviews (Nyack: Valley Cottage ES; North Rockland and 39 Willow Grove MS; East Ramapo Rockland Work Site Daycare; Ramapo Robin Hill Nursery School-March 25,2010; Clarkstown - Woodglen ES - May 11,2010) 2.3.10 Rockland County Traffic and Access Control 1................................................................ 40 2.3.11 Rockland County - Traffic and Access Control 2............................................................. 40 2.3.12 Rockland County Emergency Worker PMC (Rockland County Sewer District, September 25, 2008)........................................................................................................... 40 2.4 WESTCHESTER COUNTY................................................................................................ 42 2.4.1 Westchester County Emergency Operations Center............................................................ 42 2.4.2 Westchester County Warning Point..................................................................................... 42 2.4.3 Westchester County Accident Assessment.......................................................................... 42 2.4.4 Westchester County Field Monitori~g Team 1................................................................... 43 2.4.5 Westchester County Field Monitoring Team 2................................................................... 43 2.4.6 Westchester County Traffic Control Point 1....................................................................... 44 2.4.7 Westchester County Traffic Control Point 2....................................................................... 44 2.4.8 Westchester County - Medical Drill (Westchester Medical Center - October 28,2010.... 44 2

2.4.9 Westchester County - Special Population Bus Company Interviews (Royal Coach.......... 45 Feb.25, 2010, White Plains Bus - May 27,2010, Mile Square Bus June 3, 2010) 2.4.10 Westchester County - School Bus Company Interviews (White Plains.......................... 45 Bus - May 27, 2010, Mile Square Bus June 3, 2010) 2.4.11 Westchester County - Public Call Center......................................................................... 45 2.4.12 Westchester County - (Medical Services Transport - Trans/Care Ambulance...................46 November 5,2009) 2.4.13 Westchester County - School Interviews - (Yorktown Central School District,.............. 46 Brookside Elementary School, Crompond, Mildred E. Strong Middle School Mohansic Elementary School, Yorktown Alternative High School, December 2, 2010 2.4.14 Westchester County - Day Care Interviews - (All Aboard Child Education Center,....... 47 Lakeland Children's Center, Aunt Bessie's Open Door, Peekskill Head Start Bright Beginnings Pre-School, Rosenthall JCC of North em Westchester Chappaqua Children's Workshop, The Seed Day Care Center, Childrenspace Preschool, Young Wonders, Early Learning Center at Fieldhome, Westchester ARC/Childrens School for Early Development at St. Ann's Ossining, Holy Name of Mary Montessori School, December 16,2010)

3. SUPPORT JURISDICTION...................................................................................................... 47 3.1 Bergen County - Emergency Operations Center...................................................................... 47 APPENDIX 1. ACRONYMS AND ABBREVIATIONS............................................................. 46 APPENDIX 2. EXERCISE EVALUATORS AND TEAM LEADERS........................................ 50 APPENDIX 3. EXERCISE OBJECTIVES AND EXTENT OF PLAy........................................ 53 APPENDIX 4.2010 INDIAN POINT ENERGY CENTER EXERCISE SCENARIO................. 93 APPENDIX 5. PLANNING ISSUES............................................................................................. 95 LIST OF TABLES TABLE 1. Exercise Time Line........................................................................................................ 13 TABLE 2. Summary of Results of Exercise Evaluation............................................................... 15 3

I. EXECUTIVE

SUMMARY

On September 14, 2010 an exercise was conducted in the plume exposure pathway emergency planning zone (EPZ) around the Indian Point Energy Center (IPEC). The exercise was evaluated by Federal Emergency Management Agency (FEMA) Region II. The purpose of the exercise was to demonstrate and assess the level of State and local preparedness in responding to a radiological emergency. The exercise was held in accordance with FEMA's policies and guidance concerning the exercise of State and local radiological emergency response plans (RERP) and procedures.

The most recent previous exercise at this site was conducted on December 3, 2008. The qualifying emergency preparedness exercise was conducted on March 3, 1982.

FEMA wishes to acknowledge the efforts of the many individuals in New York State; Westchester, Rockland, Orange, and Putnam Counties; and Bergen County, New Jersey who participated in this exerCise.

Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. The cooperation and teamwork of all participants were evident during this exercise.

This report contains the draft evaluation of the biennial exercise and of the following out-of-sequence activities in Orange, Putnam, Rockland and Westchester counties: Day Cares; Reception Centers; Congregate Care Centers; Emergency Worker Personnel Monitoring Centers; General and Special Population Bus Companies; School Bus Companies; Traffic Control Points; School Interviews and Medical Drills.

The State and local organizations, except where noted in this report, satisfactorily demonstrated knowledge of their emergency response plans and procedures and adequately implemented them.

There were no Deficiencies and no new Areas Requiring Corrective Actions (ARCAs) identified; six prior ARCA's were resolved at the time of demonstration and one resolved by plan change. Two outstanding prior ARCA remains unresolved.

4

II. Introduction On December 7, 1979, the President directed the Federal Emergency Management Agency (FEMA) to assume the lead responsibility for all off-site nuclear planning and response. FEMA's activities were conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of Tribal, State, and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation injoint exercises with licensees.

FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

Taking the lead in offsite emergency planning and in the review and evaluation of Radiological Emergency Response Plans (RERPs) and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993; and Coordinating the activities of the following Federal agencies with responsibilities in the radiological emergency planning process:

- U.S. Department of Commerce,

- U.S. Nuclear Regulatory Commission,

- U.S. Environmental Protection Agency,

- U.S. Department of Energy,

- U.S. Department of Health and Human Services,

- U.S. Department of Transportation,

- U.S. Department of Agriculture,

- U.S. Department of the Interior, and

- U.S. Food and Drug Administration.

Representatives of these agencies serve on the FEMA Region II Regional Assistance Committee (RAC), which is chaired by FEMA.

5

A REP exercise was conducted on September 14,2010 to assess the capabilities of State and local emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving the Indian Point Energy Center.

The purpose of this exercise report is to present the exercise results and findings on the performance of the off-site response organizations (OROs) during a simulated radiological emergency.

The findings presented in this report are based on the evaluations of the Federal evaluator team, with final determinations made by the FEMA Region II Technological Hazards Branch Chief and RAC Chairperson and approved by the Regional Administrator.

These reports are provided to the NRC and participating States. State and local governments used the findings contained in these reports for the purposes of planning, training, and improving emergency response capabilities.

The criteria used in the FEMA evaluation process are contained in the following:

NUREG - 0654-REP-1, REV 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980.

Interim Radiological Emergency Preparedness (REP) Manual, August 2002 Section III ofthis report, "Exercise Overview," presents basic information and data relevant to the exercise. This section of the report contains a description of the plume pathway emergency planning zone (EPZ), a listing of all participating jurisdictions and functional entities that were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.

Section IV of this report, "Exercise Evaluation and Results," presents information on the demonstration of applicable exercise evaluation areas at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues-only format. This section also contains: (1) descriptions of all Deficiencies and Areas Requiring Corrective Action (ARCAs) assessed during this exercise, recommended corrective actions, and the Tribal, State, and local governments' schedule of corrective actions for each identified exercise issue and (2) descriptions of ARCAs assessed during previous exercises and resolved at this exercise, including the corrective action demonstrated as well as ARCAs assessed during previous exercises and scheduled for demonstration at this exercise which remain unresolved.

The final sections of the report are comprised of the appendices and tables. The appendices contain the following supplementary information: acronyms and abbreviations, exercise evaluators and team leaders, exercise evaluation area criteria and Extent-of-Play agreement, and a summary of the exercise scenario. The tables contain the Exercise Time Line, along with the summary results of the exercise evaluation.

6

III. EXERCISE OVERVIEW Contained in this section are data and basic infonnation relevant to the September 14, 2010 exercise held to test the offsite emergency response capabilities in the area surrounding the Indian Point Energy Center OPEC). This section of the exercise report includes a description of the plume pathway EPZ, a listing of all participating jurisdictions and functional entities that were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.

A. Plume Emergency Planning Zone Description The IPEC's 10-mile plume pathway EPZ contains portions of four New York State counties: Orange, Putnam, Rockland, and Westchester.

The IPEC is located on the east bank of the Hudson River about 24 miles north of the New York City boundary line at Indian Point, Village of Buchanan in upper Westchester County, New York. The station is about 0.8 miles southwest of the city of Peekskill, 8.3 miles south of West Point, 1.5 miles northeast of the Lovett Generating Station site, 4.6 miles north of the Bowline Point Generating Station site, and 2.3 miles north of Montrose Point.

The IPEC is accessible by several roads in the Village of Buchanan. Broadway, a two-lane paved road, borders the site to the east and is the primary access road to the site. The Village roads of Bleakley Avenue and First Street enter Broadway across from the eastern site boundary. Additionally, a paved road links the eastern boundary of the site to the plants.

There are no residences within the site boundary. In addition, there are no public highways or railroads that traverse the site area.

The IPEC is surrounded on almost all sides by high ground ranging from 600 to 1,000 feet above sea level. The site is on the east bank of the Hudson River which runs northeast to southwest at this point but turns sharply northwest approximately two miles northeast of the site. The west bank of the Hudson is flanked by the steep, heavily wooded slopes of the Dunderberg and West Mountains to the northwest (elevations 1,086 feet and 1,257 feet respectively) and Buckberg Mountain to the west-southwest (elevation 793 feet). These peaks extend to the west by other names and gradually rise to slightly higher peaks.

The general orientation of this mass of high ground is northeast to southwest. One mile northwest of the site, Dunderberg Mountain bulges to the east; north of Dunderberg and the site, high ground reaching 800 feet fonns the east bank of the Hudson as the river makes a sharp tum to the northwest.

To the east of the site, peaks are generally lower than those to the north and west. The Spitzenberg and Blue Mountains average about 600 feet in height and there is a weak, poorly defined series of ridges that again run mainly in a north-northeast direction. The river south of the site makes another sharp bend to the southeast and then widens as it flows past Croton and Haverstraw.

7

The IPEC is approximately 239 acres in size and contains three pressurized water reactors: Unit 1 (615 MWt, 265 MWe, de-fueled), Unit 2 (2,758 MWt, 873 MWe), and Unit 3 (3,025 MWt, 965 MWe). Indian Point Unit 3 is adjacent to and south of Unit 1 and Unit 2 is to the north of Unit 1. The two operating units, #'s 2 and 3, were designed by the Westinghouse Electric Corporation. Indian Point Unit 1 was decommissioned and defueled in 1974.

IPEC's pressurized water nuclear power plants each contain a nuclear reactor and closed loops of pressurized water that remove the heat energy from the reactor core and transfer the energy to a secondary water system that generates steam. The steam, in tum, drives a turbine generator set which produces electric power.

B. Exercise Participants The following agencies, organizations, and units of government participated in the Indian Point 2 exercise on September 14, 2010.

ST ATE OF NEW YORK New York State Correctional Services New York State Department of Agriculture and Markets New York State Department of Environmental Conservation New York State Department of Health New York State Department of Labor New York State Department of Taxation and Finance New York State Department of Transportation New York State Division of Criminal Justice Services New York State Division of Military and Naval Affairs New York State Education Department New York State Energy Research and Development Authority New York State Office for People with Developmental Disabilities New York State Office for the Aging New York State Office of Emergency Management New York State Office of Fire Prevention and Control New York State Office of General Services New York State Office of Mental Health New York State Office of Parks, Recreation, and Historic Preservation New York State Police New York State Public Service Commission New York Thruway Authority 8

RISK JURISDICTIONS Orange County Orange County Commission on Aging Orange County Commissioner on Emergency Services Orange County Commissioner on Finance Orange County Commissioner on Fire Services Orange County Commissioner on Mental Health Orange County Commissioners on Health Orange County Commissioners on Social Services Orange County Department of Health Orange County Department of Public Works, Buildings and Grounds Orange County Department of Social Services Orange County Deputy Commissioner for 911 Orange County District Attorney's Office Orange County Division Budget Orange County Division of Emergency Management Orange County Division of Environmental Health Orange County Division of Fire Services Orange County Executive Office Orange County Health Department Orange County Maintenance Orange County Radio Amateur Civil Emergency Services Orange County Sheriff s Office Putnam County Putnam County Bureau of Emergency Services Putnam County Department of Highways and Facilities Putnam County Department of Social Services Putnam County Deputy County Executive Putnam County Division of Mental Health Putnam County Office for Aging Putnam County Patient Services Putnam County Schools Putnam County Sheriffs Department Rockland County Rockland Board of Cooperative Education Services Rockland County Sheriff s Department Rockland County Community College Rockland County Clerk's Office Rockland County Department of Finance and Administration Rockland County Department of Health Rockland County Department of Highways Rockland County Department of Hospitals Rockland County Department of Planning 9

Rockland County Department of Public Transportation Rockland County Department of Social Services Rockland County Division Environmental Resources Rockland County Emergency Medical Services Rockland County Executive's Office Rockland County Facilities Management Rockland County Fire and Emergency Management Rockland County Fire Training Center Rockland County Legislature Rockland County Liaison Officer Rockland County Management Information Systems Rockland County Mental Health Department Rockland County Office of Consumer Protection, Weights, and Measures Rockland County Planning Board Rockland County Sewer District, Sparkill Rockland County Sheriff Westchester County Westchester County Attorney's Office Westchester County Clerk's Office Westchester County Department of Corrections Westchester County Department of Environmental Facilities Westchester County Department of Finance Westchester County Department of Health Westchester County Department of Human Resources Westchester County Department of Law Westchester County Department of Mental Health Westchester County Department of Parks and Recreation Westchester County Department of Public Safety Westchester County Department of Public Works Westchester County Department of Senior Services Westchester County Department of Social Services Westchester County Department of Transportation Westchester County Executive Office Westchester County Office of Emergency Services Westchester County Office of the Disabled Westchester County Police Department Westchester County Probation Department Westchester County Public Information 10

Support Jurisdictions Clarkstown Police Department Connecticut Department of Emergency Management and Homeland Security Grassland Fire Brigade New Castle Police Department New Jersey Department of Environmental Protection, Bureau of Nuc1ear Energy New Jersey Office of Emergency Management New Jersey State Police South Orangetown Volunteer Ambulance Stoney Point Police Department Yorktown Police Department Bergen County Bergen County Hazardous Materials Personnel Bergen County Office of Emergency Management PrivateN olunteer Organizations American Red Cross Entergy Radio Amateur Civil Emergency Services (RACES)

Westchester Emergency Communication Association The Salvation Army WHUD Radio Station staff Putnam Emergency & Amateur Repeater League (PEARL) 11

c.

Exercise Timeline Table 1, on the following page, presents the time at which key events and activities occurred during the Indian Point Exercise on September 14,2010. Also included are times notifications were made to the participating jurisdictions/functional entities.

12

TABLE 1. EXERCISE TIMELINE September 14, 2010 - Indian Point Energy Center Emergency Time Time That Notification Was Received or Action Was Taken Classification Utility State Putnam Rockland Westchester Orange Bergen Co.

JIC EAS Station Co.

Co.

Co.

Level or Event Declared EOC EOC EOC Co.EOC EOC EOC t!lert 0836 0839 0850 0917 0857 0850 0846 0852 0908 Site Area Emergency 1054 N/A 1100 N/A 1057 1058 1058 1059 1106 General Emergency 1101 1104 1105 1104 1104 1104 1104 1105 1125

~imulated Rad. Release Started 1246 1253 1250 N/A 1252 1251 1246 1300 1315 Simulated Rad. Release Terminated 1439 1434 1440 N/A 1437 1435 1436 1437 1441 Facility Declared Operational 0902 0914 0945 N/A 0940 0930 0955 0945 0915 Declaration of State of Emergency N/A N/A 1145 N/A 1106 1106 1100 1145 1140 Local State N/A 1222 N/A N/A N/A N/A N/A N/A N/A Exercise Terminated 1507 1506 1510 N/A 1506 1509 1507 1504 1506 Early Precautionary Actions - Parks closed, rail traffic N/A 0915 0915 N/A 0919 0921 0921 0916 1120 uspended, early dismissal of schools, shelter livestock

'Heads Up" Siren Activation N/A 0923 0923 N/A 0923 0923 0923 0923 0945 "Heads Up" EAS Message N/A 0927 0927 0927 0927 0927 0927 0927 0948 lst Protective Action Decision Shelter: None Evacuate: Areas in Westchester County; Buchanan, Cortland, Croton on Hudson, Montrose, Peekskill, Verplank.

N/A 1118 1118 N/A 1118 1118 1118 1118 1118

~ockland County; Bear Mountain & Harriman State Park, Jones Point. Stoney Point, Tompkins Cove.

Orange County: Bear Mountain and Harriman State Park, Highland Falls, Highlands 1st Siren Activation N/A 1121 1121 N/A 1121 1121 1121 1121 1121 1st EAS Message 1125 -

1125 1125 1125 1125 1125 1125 1125 N/A i2nd Protective Action Decision

~helter: None

~vacuate: Areas in Westchester County; Buchanan, Cortland, Croton on Hudson, Montrose, Peekskill, Verplank.ln addition Somers West of Route 18 and Yorktown N/A 1321 1321 N/A 1321 1321 1321 1321 1321 Rockland County: Bear Mountain & Harriman State Park, Jones Point, Stoney Point, Tompkins Cove.

Orange County: Bear Mountain and Harriman State Park, Highland Falls, Highlands

~nd Siren Activation N/A 1324 1324 N/A 1324 1324 1324 1324 1324

~nd EAS Message N/A 1328 1328 N/A 1328 1328 1328 1328 1328 3rd Protective Action Decision fShelter: None Evacuate: Areas in Westchester County; Buchanan,

~ortland, Croton on Hudson, Montrose, Peekskill,

~erplank. In addition; Somers West of Route 18 and

!yorktown

!Rockland County:

~ear Mountain & Harriman State Park, Jones Point, N/A 1449 1449 N/A 1449 1449 1449 1449 1449

~toney Point, Tompkins Cove.

Orange County: Bear Mountain and Harriman State Park, Highland Falls, Highlands. In addition; Town of f'::'omwall South of Angola, Town of Tuxedo, Village of

!Harriman East of Thruway, Village of Woodbury East of

~hruway and Town of Highlands excluding Highland Walls.

iKI Administration Decision 1118 1110 N/A 1111 1118 1104 1118 1118 Emergency Workers General Public in Evacuated Areas N/A 1118 N/A N/A N/A N/A 1104 N/A N/A 13

V. EXERCISE EVALUATION AND RESULTS Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the September 14, 20 10 exercise to test the offsite emergency response capabilities of State and local governments in the 10-mile EPZ surrounding the IPEC.

Each jurisdiction and functional entity was evaluated on the basis of its demonstration of criteria contained in the September 12,2001; Federal Register Notice (revised April 25, 2002). Detailed information on the exercise criteria and the extent-of-play agreement used in this exercise are found in Appendix 3 of this report.

A. Summary Results of Exercise Evaluation The matrix presented in Table 2, on the following pages, presents the status ofthe exercise evaluation area criteria from the FEMA REP Exercise Evaluation Methodology that were scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. Exercise evaluation area criteria are listed by number and the demonstration status of the criteria is indicated by the use of the following letters:

M - Met (No Deficiency or ARCAs assessed and no unresolved ARCAs from prior exercises)

D - Deficiency assessed A - ARCA(s) assessed N - Not Demonstrated (Reason explained in Subsection B)

U - Unresolved ARCA(s) from prior exercises 14

SIBf1P!I\\!PUI paJI1~1 UEJUO:) 10 JJ8l.UlEQl.L '!l SUBJ.L ffl ~

t-------------------II-j::r2 saan:JeJI3 p aJeO AleJod.ua.L ~:J 0 1-------------------1 Q. ur2 JJQ.Ud!llb3.JalI.ICM 6la.u3 P UOOE(] '!l6u!lOI!UC4111 ~ Ll: J:i t--------------------!tIlzr2 Q.

~

o ~

B!PElIIII '!l ::l!1ClI1d El4I.lOl SIJO!jOf1JjSUl '!l OJUI 6la.u3 '"

J:i 1------------------1 !!: e~

searv UO!P3C>><3 U! J!J:N '!l varv P-urud UO!IBJI!Pv' b:!; ~

t-________________

--!z()~

(J9>IBBl8 ISB.::I) u~ g~ J!J:N '!l j.IafV P-urud UO!IBJI!Pv' ~ ~ \\;j 1-________________ -1 W::J~

iE Q.

~

W

~

SIJO!JEUaCb AIojl!JOqe'l ~

0 1-________________ -1 W

~

6u!!WEs '!l SjI.JEWa.InSeEI PI9!:1 a5e4d EUnId!SOd ~!!1 Li 1-------------------\\ a:: til...!.

J )-, '"

paclQId S!~'!l SjI.JEWa.InSeEI PI.::! a5e4d EUnId tIl;i!

111 r-----------------\\ L1i Z~

J.Uf\\III S!~

'!l jI.ISI.l.QJI15eei/11 PI9I..:I asB4d EUnId d!llb3 S~'!l ~

asB4d EUnId

iE< \\;j g"'~

~ m

u.

wn~

'!lIN~~.IOj 6uPPil/ll::lG() '!l J.USS'V~

Gi t-------------------I~~~

aJ/1SOCbg jSG6u1.IOj 6u!>tEIIII UO!SPEIJ '!l J.USS'V ~ j:: Z "

() i2~

~

s,uo!12lncbd IBpeds.lOl SIJO!SPEIJ UO!Pv' IIl.Id w:iE 0

t-------------------I~z~

l!1CJ1d iBJ<lUEIE).lOlli\\J'v'd J.USS'V ~ 0 Q ~

t-------------------I~~~

UO!jEWJOJUl I!BIIV UO pasee ~d J.USS'V ~ 0 w.a t-------------------\\g:c~

PJIl.IO:J Blnsocbg.JalI.ICM kluafiJau3

~

SIJO!JEUaCb j.ICldctls 01 5a!iddns '!l jUa.lJd!llb3 til Gi t-------------------I~I-r!=

jI.Ja.lId!nb3 SIJO!!2::l!Uru&.UCl'J 0 ~ ~

I------------------It~,:;

IOJIIJOO '!l UO!jOQJO Z ~ 0 r----------------i ~ ~ ~

5a!l!IPB.::I a:: ~.a I----------------------------\\~ ~

UO!lBZ!I!CR'\\I w 111

~

... o

~

z l()

s\\enpI"IPU\\ pam!u\\ welUO~!O luaWleaJl ~ sueJl

~:;;

~------------------------------------~ ~~~

saanoe"3!O aJe~ A.ieJodwal

~::::; u

~

~

~u~

luawdlnb3 Ja)!.loM 6Jaw3 !O uooaa ~ 6uPOllUOVII g, ~ J:i

~

____________________________________ ~

en £ ~

sM3 ~ saanoell3 !O UOlleJlSl6a~/uooaa/6ulJOllUOVII 0

c2l elpaVII ~ o!lqnd alH JO! SUOIPrulSU\\ ~ O!U\\ 6JaW3

~

c

~------------------------------------~ ~~~

seaJV' uOlldaox3 ul !llON ~ lJalV' ldwOJd uOllelllPV' b ~ ~

~

~ z (.) ~

(Ja>\\eaJS lSe:l) U!LIII S~ !llON ~ lJalV' ldwOJd uOllelllPV' ~ iii ';!!!l0N ~ lJalV' ldwOJd !O uOllelllloV' as ~ ~

UJnla~ ~/Allua-a~/ola~ JO! 6uI>\\eLl\\l oaa ~ lWSSV' pe~

Qi aJnsodx3 lsa6uI JO! 6uI>\\eLl\\l uOIspaa ~ lWSSV' pe~ ~ ~ ~

(.) S2.!::!.

s,uollelndod lepads JO! suoIspaa uOIlOV' lOJd ~ ~ u

~------------------------------------~ ~ Z.!::!.

o!lqnd leJaUa~ JO! saV'd lWSSV pe~ t; Q ~

~--------------------------------------i w~.!::!.

uOlleWJO!UI lIellV' uo pases S~V'd lWssV' pe~ b frl :c

~-----------\\-O-Jl-U-O~--a-J-nS-O-d-X-3-J-a-)!.I-O-M--"-:>-u-a Ja-W-3-1 ~ c ~

N SUOlleJado lJoddns Ol sa!lddns ~ luawdlnb3 C/)

Qi

~

~ z

~

~ ~ ~

o UJ "0

~--------------------------------------i ~ as~

10JlUO~ ~ uOlloaJla z C) 0

~

~

w~~

sall!lpe:l ~ ~ :c

~

~

W ~~

as n;

UOlleZ!I!qOLl\\l z o

~

o o

...I

~

Q)

J r::T Q)

U)

.0

J en

~

CD o iii CD III m>>

x ;;C

!!l ()

~, ~

CD III 1Il~

~

III CD If)

If)

CD a.

Q c

J iil If) o

~

a. >>
C

() >>

§:

a 3

"U Q

~ ~

Co

~

3

~'

~ "U iil 0

> a

~

0

~

s::

s::

s::

m g

~(J) G) ~

3

~ 0 CD CD

~

III :y :::>

CD

~o CD 0

~ 0 o

0

~ ~

CD 0 0=

"U 0 o "U

Q 3,<0

~

a

~

~ Q. a :;?,

c:

-CD c: ![

"U dl~ ![

~

0' 0

0' a a OJ "U i'J.....

OJ c:

s:

c:

U>

U>

0

°

° 0 9

~ §:

III CD

~ :;?,

CD

~

S::S:: s:

s:s::

s::s: s:

s::s:

s::

S:S::

S::S::

s:

s:

(J).,., )om 0

m' m' 8 0

y a: a:

0 c: O Q. s: s: CD a OJ 0 0

c:

~

U> 5 0

~ ~' ~' $

U>

3 (j} (j}

i' CD III III a 3 3 i'J.....

s::s::

s::

s::

s::s::

s::

s::

s::

s::

s::

s:s: s:s::

S:S:

s:

s:

s::

s:

s:

S:S:

S:S:

s:

s::

s:

r-0 0

~

0 z

5' I

~IC

~I(I)

0 in>

0

I :::j

(')

CD -I

!m d'm

I\\"

iii' 0

I Il.

0 0 c

~

m m Mobilization

~ ~~

~ ~~

Facilities c-Gl m

~ m Z Direction & Control

"="

s::Q

~ mo Communications Equipment Z-o c-

-I z

~

en Equipment & Supplies to Support Operations Emergency Worker Exposure Control

~

-0

~ 0;0 Rad Assmt PARs Based on Avail Information tT mo

~

(')-1 tT

~~ Rad Assmt PADs for General Public 0-1

~ ~<

~ ~~ Prot Action Decisions for Special Population's

~ "(')

Q.

z::! Rad Assmt & Decision Making for Ingest Exposure

~ GlO z

Rad Assmt & Dec Making for RelolRe-entry/& Return

~

-0 Implementation of Emergency Wrkr Exposure Control til

0

~ 0 -I Implementation of KI Decision

~

m fc;;

(')

-I

~

Implementation of PADs for Special Population's fc;;

m Implementation of PADs for Schools R,

(')

fc;;

-I Q.

0 Implementation of Traffic Access & Control 6-z

~

Impediments to Evac & Traf are Identified & Resolved Q.

-0 r-f;;;

m

~

s::

Implementation of Ingestion Pathway Decisions m

fc;;

z

<D

~

Impl of IP Decisions Show Strat & Instr Material

~

-I 0

Impl of RelocationlRe-entry/Return Decisions z

Plume Phase Measurement & Analysis Equip

~

m

~ r-til 1/00 Plume Phase Field Measurement & Analysis Mgmt

'" >>s::

~ ~~

Plume Phase Fld Measurements & Analysis Proced III

"" ~~

~ en;o Post Plume Phase Field Measurements & Sampling tT -m i

ens::

m Laboratory Operations

~

z

-I 01 m Activation of Prompt Alert & Notification III

~

-oS::

em III m;o Activation Prompt Alert & Notif 15 Min (Fast Breaker)

CGl Ui' (,)z III

~~

Activation Prompt Alert & Notif in Exception Areas w

Ui' O'TI Emerg Info & Instructions for the Public & Media

~

I/O m

Monitoring/DeconlRegistration of Evacuees & EWs

~ 0 Oi' -0 zen Monitoring & Decon of Emerg Worker Equipment

~ -e

'TI-o Oi' >>-0 Q o Temporary Care of Evacuees

~ C;o Oi'

!-I

~ m Trans & Treatment of Contam Injured Individuals en

Slenp!lI!pUI paJn[UI weluo~ JO Iuawleall ~ SUeJl

(/)

c w

.!£.

~E saan::>ell3 JO aJe~ AleJodwal 0=

U

a. u

.!£.

luawd!nb3 JaljJOM 6JaW3 JO uooaa ~ 6u!J01!UOVII a.e(

c

~!!::

(/)Z

.!£.

SM3 ~ saanoell3 JO uO!leJIS!6a~IUOOaaI6u!J01!UOVII

a.

'(ij 0

CD e!paVII ~ O!lqnd alii JOJ SUO!IOnJISUI ~ 0JUI 6JaW3 0/1

c u..0 ~

seaN UO!ldaox3 U! J!ION ~ !JalV' IdwOJd uO!lell!loV' i=~ '"

~

0_

01 Zu..!!!.

(Ja>teaJS ISe.:::l) U!VII 9 ~ J!ION ~ !Jaw ldwOJd UO!lell!!OV' C!)::::;

N o::m 01 w~..!!!.

UO!le:J!l!ION ~ !JalV' ldwOJd JO uO!lell!!OV'

!ill.

'(ij

~

W SUO!leJado AlOleJoqel I-

'0 Z

w

-=t

!i(/)

6u!ldwes ~ SluawaJnSeaVII Pla!.:::l aselld awnld ISOd w_ :c 0:: en

-=t

~>-

PaoOJd S!S~leU'\\i ~ SluaWaJnSeaVII PI.:::l aselld awnld

(/)....1

~~

01

-=t lw6V11 S!S~leuV' ~ luawaJnseaVII Pla!.:::l aselld awnld

!ie(

N 00/1 01

....I

-=t d!nb3 S!S~leuV' ~ luawaJnSeaVII aselld awnld w

'(ij u:

'<t suo!spaa wnja~IAllua-a~:llUO!leOOla~ JO IdWI Z

.E 0

i=

le!JaleVII J1SUI ~ leJ1S MOllS SUo!spaa dl JO Idwi

~

N Q)

Z

~

SUo!spaa ~eMllled uO!lsa6UI JO UO!leluaWaldwl w

Qj

!i w

~

....I paillosa~ ~ pa!!!luapi aJe JeJl ~ oell3 01 Sluaw!padwi

a.

N

~

'tI

~

~

IOJ1UO~ ~ ssaoOV' o!>>eJl JO UO!leluaWaldwl Z

c 0

~

i=

SIOOljOS JOJ SaV'd JO UO!leluaWaldwl U

N CJ e(

~

w S,UO!lelndod lepads JOJ saV'd JO UO!leluaWaldwl U

~

i=

~

U uo!spaa 1>1 JO UO!leluaWaldwl w

c I-

~

0 10JIUO~ aJnsodX3 JljJM ~ua6Jaw3 JO uO!leluawaldwl 0::

'(ij

a.

Wnja~ ~IAllua-a~IOla~ JOJ 6u!>teVII oaa ~ lWSSV' pe~

Qj Z

~

OC!)

9Jnsodx3 Isa6uI JOJ 6u!>teVII Uo!spaa ~ lWSSV' pe~

i=~ :c U~ ~

S,UO!lelndOd lepads JOJ SUo!s!oaa UO!!OV' 10Jd e(~

U

~

~z ~

O!lqnd leJaUa~ JOJ SaV'd lWSSV' pe~ 1-0 N

~

u-n w!Q ~

uO!leUJJoJUI l!ellV' uo pases S~V'd lWssV' pe~ I-U

c Ow 0::0 ~

IOJ1UO~ aJnsodX3 JaljJoM ~oua6JaW3 a.

'(ij N

SUO!leJado !Joddns 01 sa!lddns ~ luawd!nb3 en Qj

~ ~

zl-

~

luawd!nb3 suo!le:J!unwwo~ a. z

~ ~

Ow "C

>-::!i ~

10JIUO~ ~ UO!!OaJ!a Uw U

~

ZC!)

we( ~

sa!l!l!oe.:::l C!)z

c ffi~
!i

~

uO!lez!I!qoVII w

'(ij

~ ~

~

l 0

(.)

~

WI'S 0

WI~

c

... a..

... 0.

~

c c( Q) 0 en III aU}

=c Z

..5 0 -

i=

c:

c(

"0 0

a.. g 9 (.) "E o RI w3:

~

~

~

~~

~ ~ ~~ ~

~ ~ ~ ~ ~

~

~ ~

~ ~

~

c:

Q)

(.)

c:

0

~

N

~

E E Q) 0::.-

N RI RI - -

c:

Q) {E c: c: c:

~I-0 "0 "0 Ul g g ~ a.. a..

~ "§

~ ee "C::

Ul_ B 0 'E'E

~ "§ "2 a.. o 0

0

(.)(J lii:::i: :::i: ~ o 0

~:!2 "C Q) tete Qj c::

o

"!!1 Q)

~ ~

<<LL u:: (!) 1 ~~

~

~ ~

~ ~

~

~

E 0

(.)

Ul

~

l al

~ ~

c:

0

~

Q) 0 "2: (.) ~

Q)

Ul

l 0

Eal a..

00 co o

0 "0

.s::.s::

.~

o 0

mm m

~

(J

i:

a..

~

t:

0

~

c::

~

Q)

E w

gj Ul

~

Q)

~ o

~

E g Ul

<<~

u m o::~

<< c u

0

~ts

~~

Q) C c~

Q) o "!:

C III uo.

C X IIlW U

C Q) 0 III III III III Q)

Q)

Jl!;

<<u cn~

~-5 u Q) 0::.I::.

<<~

o III

>>1Il ou C

Q)

~~

'al~

OOi:j' o E c

~~"~

Q)o~

~zo I

I I

~zo

c: e "C

~

s Ql "C

Cl

~

'E E

~

al

'0 IS

,S Ul

l 0

Ul C.

CO CO

'E

<II Ul ct:

U Ul Ul (ij Cl e

~

~

CO w

'iii

-c:

Ql

~

E

'6 Ql 0

ct:

c:

0-

l Ul c:

Ul

c. ~

~

,2 0

~

Ul C.

co

~

(J) oCI E

-c:

Ul "C

c:

0

l Cii oCI

'iii c:

'3

'iii Ul en

'lil c:

Ul

c.
2 0

~

,2 w

'E Ul

'3 e

'0 0

a J?-

'iii oCI co 0

Ql Cii 0

"C

'iii LJJ J?-

oCI Ql "0

f!!

E iii

c.

'E Ql Ql

<

c.

a

'0 Ul

<<I Ul c:

,s.!

l LJJ c:

~

Ql

)(

0 0

!E iii

~

c:

c:

'E 0

~

<)

e.2

c.

Cl Ql LJJ 0-U

'E

'iii

~

~

Ql

~

c:

0

~ iii "C

SITE

<)

0 c:

ct:

Ul c:

~ ~

~

0

'E

-=

0- -

'0 j (ij

'0 oCI Ql

~ -

E (ij oCI oCI E

l W

~

t

0

'0 0

"C oCI c:

'E

~

It) 0-

~

l Indian Point 0

'iii

l (ij

.2 Qi

<II -

.c

l

!l c:

(J)

'0

'2' 0

U 0-ct:

Ql

.c Ul

~

Cii

"§ al

~

Ql

l

~.....

.c

c.

~

'u Cl c:

C.

<)

~

E c:

Ul

~

~

c:

c.

~

~

Ql c:

~

en en co 0-W ct:

oCI Ql co z

'0 15 0

EI Ul E

'E

l c:
c.
i2

.2 c:

0

<)

'§ c:

~ 'E

~ E Ql

~ ~

Ql Ql

~

l

'iii oCI Z

Z Ql en Ul 0

Ql en co Ql

.2

.2

~

0 Ql

l

~

~

E Ql E

8.

c:

~

Cl EI 'u 0

I-

~

'E

<II t

oCI oCI If>

l 0

.9

-g

~

c:

~

Ul Ul 0

E

l "C

Ql c:

'lil LJJ 0

DATE

c.

.2

i2 Ql a

a

==

oCI Ql

.c Ql

~

co Ul Qi

< t t

0

'g>

co U

<II c:

Ql

<II

'0 Ql w

Ul Ul 0

<<I E

~ ~ f!!

0 Cl en cU

~

<<I c:

Ql Ql 13

'0 14-Sep-10

<<I 52

l Ql u:

LJJ a

m

.2 c:

'iii

~ LJJ I-

<<I

-=

Ul

~

Ul 0

Q. < <

l ct:

c:

e w Q.

iii 0

c:

co "C

Ql

~

0

'0

'E

c.

~

<II Ul

'iii

'0 0

'0 '0

'0 '0 '0 LJJ

'0 0

(J)

Qi "C

Ul E

Q.

Q.

'lil

'i:

0 Ul Ql (J) 0 Ql

'E c:

l ct:

a

'0

'iii

~ u:

u:

co e

E E

c:

8

~

~

en

~

a a

c:

c:

c:

c:

c:

.9 c:

§

.c

~

0 0

~ ~ ~

0 0

0 0

0 0

'0

c.

0-0 e -

Ql co U

~

oCI oCI oCI l'§

~

l'§ E !l l'§ Ql Ql Ql Ql a..

0

'0 0:

oCI Q

oCI u

c:

Cii Ul

<II Ul 0-

~

0 oCI

'E

~ E E c: E E

'E c:

a Qi co

<<I

<II Ql

~

.2 Cl Cl

~

Ul c:

'c; Ql c:

0 c:

c:

c:

Ql c:

0-ct:

.c J:

J:

E 0

c:

c:

c:

c:

c:

c:

f!!

I-

l Ql Ul Ul ti Ul Ul Ql Ql Ql Ql Ql E

Ql -

0-a..

0-

l 0

0 0 - £

'C:

oCI N

Ql 0

E Ul

<II Ul Ul E

E E

E E

E

'0 '0 a::

~ Cii

~ :;;

0 0

n E

c.

EI

~

~

~

~

~

Ql Ql Ql Ql Ql

'6 Ql Ql Q)

Ql EI C.

<II

is 13

~

E

'3 Ql "C

"C e "C "C

Q.

Q.

C.

C.

Q.

Ql C.

C.

C.

E E

E iii

,2 (J)

'c; c:

E c:

0 co 0

a E

co

<<I co

<

I I

~

I

.g i 1

j j I i I i i i

.; i i

~

~

a6

! j J i

i

~

a6

~

1

~ j ] I

.11 SITE

~

.11

~

111

~

I a6

~

~

j I

~

~

i

~

Indian Point i

1 I

.Q

~

j

~ I J

~ i 1!

'!5 i ) i

.Q j Ii

~

~

~

b i5 f I !

j i5

  • iII

.ll

.ll

~ i i I

~

I s

J

.ll E'

~

~ ~

0

~

i i

~

~ i DATE Kl

.g I

~

i i

~ I

'5 14-Sep-10

.ll j 2

~

II:

f

'!5

~

! j f ~

~ ~

'!5

'5

'!5 I

'!5

'!5.g f ~ I f f

~

'!5 I I

I I t t j Ii S

~

~

~

I

~ i ~

'!5

~

i

~ i I j j ~ i j

~ f

~

E' J

~

~

[l.

j i j

~

'!5

~ ~ ~

0:

I I i

~

~ 'Q

~ ~

~

~

~

~ ~ ~ ~

~ ~ E"

~

~

~

u..

C EMERGENCY OPNS PROTECTIVE ACTION PROTECTIVE ACTION IMPLEMENTATION FIELD MEASUREMENT EMERG NOTIF &

SUPPORT MANAGEMENT DECISION-MAKING

& ANALYSIS PUBLIC INFO OPN/FACILITIES lal11bl11Cl 11dl j1e1 2al 12bl 12b212cl 12d1 12el 3al 13b113c1 13c213dl 13d213e113e213f1 4a1 14a214a314bl 14C1 Sal 15a215a31sb1 6al 16bl 16cl 16dl LOCATION - Bergen Coun~

EOC MIMIMIMIMI I

I I

I I

I

_l 1 IMIMJ 1 -'

I

~ ~ i J

J I II i i

J I

~

M - Met (No Deficiency or AReA(s) Assessed and no Unresolved AReAs from Prior Exercises N - Not Demonstrated as Scheduled (Reason Explained in Section IV. B)

A - AReA(s) Assessed or Unresolved AReA(s) from Prior Exercises D - Deficiency 20

B.

Status of Jurisdictions Evaluated This subsection provides information on the evaluation of each participating jurisdiction and functional entity, in a jurisdiction-based, issues-only format. Presented below is a definition ofthe terms used in this subsection relative to objective demonstration status.

Met - Listing of the demonstrated exercise evaluation criteria under which no Deficiencies or AReAs were assessed during this exercise and under which no AReAs assessed during prior exercises remain unresolved.

Deficiency - Listing of the demonstrated exercise evaluation criteria under which one or more Deficiencies were assessed during this exercise. Included is a description of each Deficiency and recommended corrective actions.

Area Requiring Corrective Actions - Listing of the demonstrated exercise evaluation criteria under which one or more AReAs were assessed during the current exercise or AReAs assessed during prior exercises remain unresolved. Included is a description of the AReAs assessed during this exercise and the recommended corrective action to be demonstrated before or during the next biennial exercise.

Not Demonstrated - Listing ofthe exercise evaluation criteria which were not demonstrated as scheduled during this exercise and the reason they were not demonstrated.

Prior ARCAs - Resolved - Description of AReAs assessed during previous exercises which were resolved in this exercise and the corrective actions demonstrated.

Prior ARCAs - Unresolved - Description of AReAs assessed during prior exercises which were not resolved in this exercise. Included is the reason the AReA remains unresolved and recommended corrective actions to be demonstrated before or during the next biennial exercise.

The following are definitions of the two types of exercise issues which are discussed in this report.

A Deficiency is defined in FEMA-REP-14 as "... an observed or identified inadequacy of organizational performance in an exercise that could cause a finding that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant."

An AReA is defined in FEMA-REP-14 as "... an observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself to have adverse impact public health and safety."

21

FEMA has developed a standardized system for numbering exercise issues (Deficiencies and ARCAs).

This system is used to achieve consistency in numbering exercise issues among FEMA Regions and site-specific exercise reports within each Region. It is also used to expedite tracking of exercise issues on a nationwide basis.

The identifying number for Deficiencies and ARCAs includes the following elements, with each element separated by a hyphen (-).

Plant Site Identifier - A two-digit number corresponding to the Utility Billable Plant Site Codes.

Exercise Year - The last two digits of the year the exercise was conducted.

Evaluation Area Criterion - A letter and number corresponding to the criteria in the FEMA REP Exercise Evaluation Methodology.

Issue Classification Identifier - (D = Deficiency, A = ARCA). Only Deficiencies and ARCAs are included in exercise reports.

Exercise Issue Identification Number - A separate two (or three) digit indexing number assigned to each issue identified in the exercise.

22

1.

NEW YORK STATE 1.1 Emergency Operations Center

a.

MET: La. 1, I.b.1, I.e. 1, I.d.1, I.e. 1, 2.b.2, 2.c.l, 3.c.l, 5.b.1

h.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIORARCAS - UNRESOLVED: ONE ISSUE: 32-08-5.a.l-A-O 1 CONDITION: During the preparation of the third EAS message, there was confusion between Orange County and the State EOC. The OCEOC listed specific instructions and areas to be evacuated and announced in the EAS. These areas are mentioned in OC's Evacuation Plans. The State EOC was more general in the writing of the EAS. For example, instead of writing "Town of Cornwall East ofRt. 32 is to be evacuated" the State EOC wrote "Town of Cornwall is to be evacuated." This would have the effect of directing members of the public outside the 1 O-mile EPZ to evacuate. The State mentioned there was an issue with their pre-scripted EAS messages.

The OCEOC advised the State EOC to review the county's Radiological Emergency Response Plans for specific localities and area descriptions in the Orange County portion of the 10-mile EPZ. The discussions between the OCEOC and the State to correct the EAS message delayed its release and also delayed the sounding of the sirens, possibly putting members of the public at risk.

POSSIBLE CAUSE: The State did not review the locations and boundary limits for all localities within the 10-mile EPZ for Orange Country prior to drafting EAS messages. They may not have the updated and correct pre-scripted EAS messages.

REFERENCE:

NUREG-0654, E.5.6.7.

EFFECT: If the State's original EAS message had been broadcast, some of the public outside the 10 - mile EPZ would have been incorrectly advised to evacuate and incorrectly advised to take KI (which they do not have). This could have led to general confusion as to who should evacuate and who should stay behind. The delay of the sirens while the text of the EAS message was corrected could have put people in the EPZ at risk.

RECOMMENDATION: The NY State Emergency Management Agency should work with Orange County personnel to be sure that the EPZ area information is accurate, and that pre-scripted EAS messages are clear.

23

CORRECTIVE ACTION SCHEDULE: Correction of this issue will be verified at the next federally - evaluated biennial exercise.

1.2 Warning Point

a.

MET: 1.a.1, 1.d.1, 1.e.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 1.2 Accident Assessment

a.

MET: 2.a.1, 2.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 1.4 Emergency Operations Facility

3.

MET: I.a.1, I.c.l, I.d.l, I.e.l, 3.a.l, 3.b.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 24

1.5 Joint Information Center

a.

MET: 1.a.l, 1.e.l, 1.d.l, 1.e.l, 5.a.l, 5.h.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 1.6 Emergency Alert Station - Station WHUD-FM

a.

MET: 1.d.I,5.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE

1. 7 State of New York Call Center
a.

MET: 1.a.l, 1.e.I, I.d.l, I.e.l, 5.bl

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 25

2.

RISK JURISDICTIONS 2.1 ORANGE COUNTY 2.1.1 Orange County Emergency Operations Center

a.

MET: I.a.l, I.c.l, I.d.l, I.e.l, 2.b.2, 2.c.l,

3. c.l, 3.c.2, 3.d.l, 3.d.2, S.a.l, S.a.3, S.b.l
b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: ONE PRIOR ISSUE: 32-08-S.a.l-A-02 CONDITION: The Joint Information Center's web page on New York Alert posted two Information Alerts for the general public at 1222 and 1243. In each

/

case the counties and the specific localities evacuated were listed, with areas to be evacuated shown in bold-face type. However, unlike the other three counties, the Orange County list was divided into two sections. Some areas were listed in the bolded section under Orange County. Other towns/villages where listed in plain text in a paragraph format within the text of the document.

Example - in bolded text:

Orange County:

Bear Mountain State Park West Point Highlands "Orange County orders additional evacuation of these areas Village of Harriman East of the NYS Thruway, Village of Woodbury East ofNYS Thruway... "

If this had been an actual emergency, members of the public may not have seen the "additional areas" to be evacuated if they did not completely read - and understand - the on-line bulletins.

CORRECTIVE ACTION DEMONSTRATED: The news bulletins posted on the NY Alert web site were accurately posted. The evacuation locations were not divided into sections, nor displayed in a different font or style. All evacuation locations for the four risk counties were displayed in the same format. This closes ARCA 32-08-Sal-A-02.

f.

PRIOR ARCAS - UNRESOLVED: NONE 26

2.1.2 Orange County Warning Point

a.

MET: La.l, Ld.I, I.e. I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.3 Orange County Accident Assessment

a.

MET: 2.a.l, 2.b.l, 4.a.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARC AS - UNRESOLVED: NONE 2.1.4 Orange County Field Monitoring Team 1

a.

MET: La.I, Ld.l, 3.a.l, 3.b.I, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 27

2.1.5 Orange County Field Monitoring Team 2

a.

MET: l.a.I, l.d.I, 3.a.l, 3.b.l, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.6 Orange County - General Population Recep~ion Center - (Newburg Free Academy -

April 28, 2010)

a.

MET: 3.a.l, 3.b.l, 6.a.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.7 Traffic and Access Control 1

a.

MET: 3.a.I, 3.b.I, 3.d.I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 28

2.1.8 Orange County Traffic and Access Control 2

a.

MET: 3.a.l, 3.h.l, 3.d.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.9 Orange County Special Population Bus Company - (Monroe - Woodbury Bus Co.

October 14,2010)

a.

MET: 3.a.l, 3.b.l, 3.c.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.10 Orange County School Interview - (Highland Falls Intermediate School October 14, 2010)

a.

MET: 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 29

2.1.11 Orange County School Bus Company - (West Point Tours, October 14,2010)

a.

MET: 3.a.1, 3.h.l, 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.1.12 Orange County - Medical Services Hospital (St Lukes Cornwall Hospital - May 28, 2009)

a.

MET: 3.a.l, 3.h.l, 6.d.l

b.

AREAS REQUIRING CORRECTIVE ACTION: NONE

c.

DEFICIENCY: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 30

22.2 PUTNAM COUNTY 2.2.1 Putnam County Emergency Operations Center

a.

MET: l.a.l, l.c.l, l.d.1, l.e.l, 2.b.2, 2.c.l, 3.c.l, 3.c.2, 3.d.1, 3.d.2, 5.a.1, 5. a.3, 5.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: ONE ISSUE: 32-08-S.b.l-A-04 CONDITION: Several Emergency Alert System (EAS) Follow-On messages that had been approved for publication by the Putnam County leadership were not published in the NY -Alert system.

CORRECTIVE ACTION DEMONSTRATED: In response to Issue 32 5.b.l-A-04 the county developed and logged 4 EAS Follow on News Bulletins correlating the Alert, and General Emergency declarations. An additional follow-on message was generated updating the general public that the County Executive was currently monitoring the situation and would advise the resident with any new information; that Putnam County schools inside the 10 mile Emergency Planning Zone (EPZ) had been relocated and the remaining schools outside the EPZ were dismissed early; that field monitoring teams were in the field; and that police, fire, and Emergency Medical Services (EMS) were on standby. The final follow-up message informed the general public that a release of radioactive material from the Indian Point Energy Center was occurring. Each of the follow-on news releases were successfully documented in the NY Alert System in accordance with the Putnam County Radiological Response Plan.

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.2 Putnam County Warning Point

a.

MET: l.a.l, l.d.l, l.e.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE 31

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.3 Putnam County Accident Assessment

a.

MET: 2.a.I, 2.b.I, 4.a.2

h.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.4 Putnam County Field Monitoring Team A

a.

MET: 1.a.I, 1.d.I, 3.a.l, 3.b.l, 4.a.I, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.5 Putnam County Field Monitoring Team B

a.

MET: 1.a.I, 1.d.l, 3.a.l, 3.b.i, 4.a.i, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 32

2.2.6 Putnam County - General Population Reception Center (George Fisher Middle School-May 25, 2010)

a.

MET: 3.a.l, 3.b.l, 6.a.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.7 Putnam County - General Population Reception Center Reception Center (Carmel High School-September 2,2009 Registration Only and May 24, 2010)

a.

MET: 3.a.l, 3.b.l, 6.a.l, 6.b.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: TWO ISSUE NO: 32-08-6.a.l-A-05 CONDITION: At both male and female decontamination areas, although they appear in the Reception Center Schematics (Putnam County Radiological Response Plan Appendix V, Rev 8/08, page V -6), step-off pads were not utilized. At the male decontamination area, the post-decontamination survey was conducted in the middle of the room and not at a clear egress point. The evacuee was then allowed to walk out through a potentially contaminated area. Also in the male decontamination area the personnel monitors were not initially aware of the release criteria and (0.1 mR above background) and had to be prompted by the controller. At the female decontamination area, the bottoms of the evacuee's shoes were not checked and the Personnel Decontamination Specialists were admittedly not familiar with the procedure. In both areas, contamination controls must be improved to prevent the potential spread of contamination to non-contaminated areas of the facility.

33

CORRECTIVE ACTION DEMONSTRATED: The Deputy Commissioner, Putnam County Bureau of Emergency Services requested retraining and the opportunity to re-demonstrate the operation of the Reception Center at Carmel High School. On May 11, 2010, FEMA conducted an assistance visit to assist with the re-training of Reception Center staff. One subject matter expert from FEMA assisted two representatives from NYSEMO in conducting "hands-on" re-training of the reception center staff at Carmel High School. Training topics included: exposure control; monitoring of evacuees; proper set-up and use of the decontamination facilities and contamination limits and how to apply them. The training was well-received by the volunteers who staff the facility.

On May 24, 2010 at 1630, in an evaluated out-of-sequence demonstration, Putnam County successfully re-demonstrated the ability to operate the Reception Center at Carmel High School. This re-demonstration was only required to cover the monitoring and decontamination of evacuees. However, exposure control was also re-demonstrated and was evaluated. The staff consisted of members of RACES, the Medical Reserve Corp., and the Putnam County Health Department.

No issues were identified as a result of this re-demonstration.

ISSUE NO: 32-08-6.a.l-A-06 CONDITION: At the personnel monitoring point, after an alarm was received on the portal monitor, the Personnel Monitor proceeded to frisk the evacuee. This unnecessary step took several minutes to complete and is contrary to the Putnam County Radiological Response Plan, Procedure 3, step 4.5.7, which directs the Monitor, in the event of an alarm to, "note the area of the alarm indication and to direct the evacuee to step back and proceed to the decontamination area."

CORRECTIVE ACTION DEMONSTRATED: The Deputy Commissioner, Putnam County Bureau of Emergency Services requested retraining and the opportunity to re-demonstrate the operation of the Reception Center at Carmel High School. On May 11, 2010, FEMA conducted an assistance visit to assist with the re-training of Reception Center staff. One subject matter expert from FEMA assisted two representatives from NYSEMO in conducting "hands-on" re-training of the reception center staff at Carmel High School. Training topics included: exposure control; monitoring of evacuees; proper set-up and use of the decontamination facilities and contamination limits and how to apply them. The training was well-received by the volunteers who staff the facility.

34

2.2.8 Putnam County - Medical MS-l Drill (Putnam Hospital Center/Carmel Ambulance-May 12,2010)

a.

MET: 3.a.I,3.b.l,6.d.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.2.9 Putnam County Traffic and Access Control 1

a.

MET: NONE

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: THREE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE CONDITION: This interview did not take place due to a real life emergency involving the Sheriffs Department, and will be rescheduled for the next federally graded exercise.

2.2.10 Putnam County - Traffic and Access Control 2

a.

MET: 3.a.l, 3.b.I, 3.dI

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE.

f.

PRIOR ARCAS - UNRESOLVED: NONE 35

2.2.11 Putnam County - Emergency Worker Personnel Monitoring Center (Carmel Fire Dept.

November 16, 2010)

a.

MET: 3.a.l, 3.b.l, 6.a.l, 6.b.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 36

2.3 ROCKLAND COUNTY 2.3.1 Rockland County Emergency Operations Center

a.

MET: I.a.l, I.c.l, I.d.!, I.e.!, 2.b.2, 2.c.l, 3.c.I, 3.c.2, 3.d.l, 3.d.2, S.a.I, S.a.3, S.b.1

h.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.2 Rockland County Warning Point

a.

MET: 1.a.1, 1.d.1, 1.e.1

h.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.3 Rockland County Accident Assessment

a.

MET: 2.a.1, 2.b.I, 3.a.1, 3.b.I, 4.a.2

h.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARC AS - UNRESOLVED: NONE 37

2.3.4 Rockland County Field Monitoring Team 1

a.

MET: l.a.l, l.d.l, 3.a.l, 3.h.l, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.5 Rockland County Field Monitoring Team 2

a.

MET: l.a.l, l.d.l, 3.a.l, 3.b.l, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.6 Rockland County Special Population Bus Company Interviews (Chestnut Ridge -

January 11,2010; Student Bus January 7,2010)

a.

MET: 3.a.l, 3.b.l, 3.e.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 38

2.3. 7 Rockland County - School Bus Company Interviews(Chestnut Ridge -

January 11,2010; Student Bus January 7, 2010)

a.

MET: 3.a.I, 3.b.I, 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3. 8 Rockland County - General Population Bus Company Interviews(Chestnut Ridge -

January 11,2010; Student Bus January 7, 2010)

a.

MET: 3.a.l, 3.b.l, 3.c.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.9 Rockland County - School Interviews (Nyack: Valley Cottage ES; North Rockland and Willow Grove MS; East Ramapo Rockland Work Site Daycare; Ramapo Robin Hill Nursery School-March 25, 2010; Clarkstown - Wood glen ES - May 11,2010)

a.

MET: 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR AReAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 39

2.3.10 Rockland County Traffic and Access Control 1

a.

MET: 3.a.l, 3.b.I, 3.d.I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.11 Rockland County - Traffic and Access Control 2

a.

MET: 3.a.I, 3.b.I, 3.d.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.3.12 Rockland County - Emergency Worker Personnel Monitoring Center (Rockland County Sewer District September 25, 2010)

a.

MET: 3.b.l, 6.a.l, 6.b.I

b.

AREAS REQUIRING CORRECTIVE ACTION: NONE

c.

DEFICIENCY: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIORISSUES-RESOLVED:NONE

f.

PRIOR ISSUES - UNRESOLVED: ONE 40

ISSUE NO: 7S-06-3.a.l-A-09 ISSUE: The South Orangetown Ambulance Emergency Medical Technicians (EMT) were issued a high range 0 to 200 R direct reading dosimeter but were not issued a low range dosimeter.

REASON UNRESOLVED: South Orangetown Ambulance EMTs were not demonstrated (or evaluated) during this exercise.

CORRECTIVE ACTION SCHEDULE: Low range dosimeters will be verified at the next demonstration and evaluation of the South Orangetown Ambulance Corps, or during a FEMA Staff Assistance Visit before the next federally - evaluated biennial exercise.

41

2.4 WESTCHESTER COUNTY 2.4.1 Westchester County Emergency Operations Center

a.

MET: l.a.l, l.e.I, I.d.l, I.e.l, 2.b.2, 2.e.l, 3.e.I,

3. e.2, 3.d.1, 3.d.2, 5.a.l 5.a.3, 5.b.l
b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.2 Westchester County Warning Point

a.

MET: La. I, I.d.I, I.e.l, 5.a.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.3 Westchester County Accident Assessment

a.

MET: 2.a.I, 2.b.1, 4.a.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

pRlOR ISSUES - UNRESOLVED: NONE

e.

NOT DEMONSTRATED: NONE

f.

PRIOR ARCAS - RESOLVED: ONE 42

ISSUE NO: 32-08-4.a.2-A-09 ISSUE: In order to characterize the plume, both exposure rate data and radioiodine concentration measurements are needed. The licensee uses one of two default noble gas to iodine ratios for two types of release scenarios. For a Loss of Coolant Accident the assumed noble gas to iodine ratio is 10000 and for a steam generator accident the ratio is 100.

The field monitoring data is one method verifying the validity of these assumptions. The licensee failed to provide any radioiodine concentration data to the offsite jurisdictions.

CORRECTIVE ACTION DEMONSTRATED: The collection of four air samples and the fact that at 1257, the Westchester County dose assessors received an IPEC Radiological Emergency Data Form Part 2 defining the measured noble gas and iodine release rates and the noble gas to iodine ratio closes the previous ARC A number 32-08-4.a.2-A-09.

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.4 Westchester County Field Monitoring Team 1

a.

MET: l.a.l, l.d.l, 3.a.l, 3.b.l, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR AReAS - RESOLVED: NONE

f.

PRIOR AReAS - UNRESOLVED: NONE "2.4.5 Westchester County Field Monitoring Team 2

a.

MET: 1.a.l, l.d.l, 3.a.l, 3.b.l, 4.a.l, 4.a.3

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR AReAS - RESOLVED: NONE

f.

PRIOR AReAS - UNRESOLVED: NONE 43

2.4.6 Westchester County Traffic Control Point 1

a.

MET: 3.a.I, 3.b.1, 3.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.7 Westchester County Traffic Control Point 2

a.

MET: 3.a.1, 3.b.I, 3.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.8 Westchester County - Medical Drill (Westchester Medical Center - October 28, 2010)

a.

MET: 3.b.1,6.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 44

2.4.9 Westchester County - Special Population Bus Company Interviews (Royal Coach-Feb.25, 2010, White Plains Bus - May 27, 2010, Mile Square Bus June 3, 2010)

a.

MET: 3.a.l, 3.b.l, 3.c.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.10 Westchester County - School Bus Company Interviews (White Plains Bus - May 27, 2010, Mile Square Bus June 3, 2010)

a.

MET: 3.a.I, 3.b.I, 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 2.4.11 Westchester County - Public Call Center

a.

MET: 1.a.l, 1.d.l, 1.e.l, 5. b.I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE 45

2.4.12 Westchester County - (Medical Services Transport-Trans Care Ambulance Service November 5, 2009)

a.

MET: 3.a.1, 3.b.1, 6.d.l

b.

AREAS REQUIRING CORRECTIVE ACTION: NONE

c.

DEFICIENCY: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: ONE ISSUE NO: 75-06-3.a.l-A-12 ISSUE: The ambulance crew (Transcare Ambulance Service who responded to the Emergency Worker Personnel Monitoring Center (PMC) to transport the injured emergency worker did not have any dosimetry. While the PMC was located outside the emergency planning zone, handling and transporting a contaminated emergency worker requires the use of dosimetry by the ambulance crew in accordance with Westchester County Procedure IP-3.3, Section 3.5.

CORRECTIVE ACTION DEMONSTRATED: The Transcare Ambulance Service is no longer referenced in the Westchester County Radiological Emergency Response Plan and will no longer be used to transport injured emergency workers.

Therefore ARCA 75-06-3al-A-12 is closed.

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.4.13 Westchester County - School Interviews - (Yorktown Central School District, Brookside Elementary School, Crompond, Mildred E. Strong Middle School, Mohansic Elementary School, Yorktown Alternative High School, December 2, 2010)

a.

MET: 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOL YED: NONE 46

2.4.14 Westchester County - Daycare Interviews - (All Aboard Child Education Center, Lakeland Children's Center, Aunt Bessie's Open Door, Peekskill Head Start, Bright Beginnings Pre-School, Rosenthall JCC of Northern Westchester, Chappaqua Children's Workshop, The Seed Day Care Center, Childrenspace Preschool, Young Wonders, Early Learning Center at Fieldhome, Westchester ARC

/ Children's School for Early Development at St. Ann's Ossining, Holy Name of Mary Montessori School, December 16,2010)

a.

MET: 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARC AS - RESOLVED: NONE

f.

PRIOR ARCAS - UNRESOLVED: NONE

3.

SUPPORT JURISDICTION 3.1 Bergen County - Emergency Operations Center

a.

MET: La. 1, l.b.1, I.c.1, I.d.1, I.e.1, 3.c.2, 3.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ARCAS - RESOLVED: NONE

f.

PRIOR ARCAs - UNRESOLVED: NONE 47

ACP ARC ARCA ARES BOCES CFR CPM DHS DOE DOH DOT EAL EAS ECL EMS EMO EOC EOF EPA EPZ ERPA EWPMC FDA FEMA GE ICF IPEC JNC KI MIDAS mR MRP-DAS APPENDIX 1. ACRONYMS AND ABBREVIATIONS Access Control Point American Red Cross Area Requiring Corrective Action Amateur Radio Emergency Service Board of Cooperative Educational Services Code of Federal Regulations Counts Per Minute Department of Homeland Security u.S. Department of Energy Department of Health U.S. Department of Transportation Emergency Action Level Emergency Alert System Emergency Classification Level Emergency Medical Service Emergency Management Organization Emergency Operations Center Emergency Operations Facility U.S. Environmental Protection Agency Emergency Planning Zone Emergency Response Planning Area Emergency Worker Personnel Monitoring Center U.S. Food and Drug Administration Federal Emergency Management Agency General Emergency ICF Consulting, Inc.

Indian Point Energy Center Joint News Center Potassium Iodide Meteorology Information and Dose Assessment System milliRoentgen Meteorological Radiological Plant "Data System 48

NOUE NRC NUREG-0654 NYS NYSEMO OCEOC ORO PAR PCEOC PIO PMC PSC RAC RACES RCEOC REA RECS REP REPP RERP RETA SAE SEMO SEOC TCP TDD TEDE TL TLD USDA WCEOC Notification of Unusual Event U.S. Nuclear Regulatory Commission New York State New York State Emergency Management Office Orange County Emergency Operations Center Offsite Response Organization Protective Action Recommendation Putnam County Emergency Operations Center Public Information Officer Personnel Monitoring Center New York State Public Service Commission Regional Assistance Committee Radio Amateur Civil Emergency Service Rockland County Emergency Operations Center Radiological Emergency Treatment Area Radiological Emergency Communications System Radiological Emergency Preparedness Radiological Emergency Preparedness Plan Radiological Emergency Response Plan Radiological Emergency Treatment Area Site Area Emergency State Emergency Management Office State Emergency Operations Center Traffic Control Point Telephone Device for the Deaf Total Effective Dose Team Leader Thermoluminescent Dosimeter U.S. Department of Agriculture Westchester County Emergency Operations Center 49

APPENDIX 2. EXERCISE EVALUATORS and TEAM LEADERS LOCATION EVALUATOR AGENCY EXERCISE OVERSITE R. Thomson FEMA Chair, Regional Assistance Committee STATE OF NEW YORK New York State Emergency Operations Center Kevin Reed (TL)

FEMA Patricia Mason FEMA Laura Forrest FEMA New York State Warning Point Patricia Mason FEMA Indian Point Emergency Operations Facility Doug Tifft NRC New York State Accident Assessment James Hickey ICF Indian Point Joint Information Center Rick Kinard FEMA Region III Indian Point Joint Information Center Briefings Deborah Bell ICF Indian Point Joint Information Center - Media Patricia Tenorio FEMAflQ Monitoring Indian Point EAS Station W ABC Miriam Weston FEMA State of New York Call Center Rosemary Samsel ICF ORANGE COUNTY Orange County - Warning Point Sara Gelves FEMA Orange County Emergency Operations Center William Cullen (TL)

FEMA Sara Gelves FEMA Gary Goldberg ICF Sam Nelson ICF Orange County Accident Assessment Kenneth Wierman FEMAHQ Orange County - Field Monitoring Team 1 Michael Howe FEMAHQ Orange County - Field Monitoring Team 2 Raymond Wood ICF Orange County - General Population Reception Dave Stuenkel ICF Center - Newburgh Free Academy

  • Ron Biernacki ICF Orange County Traffic Control Point 1 Carl Wentzell ICF Orange County Traffic Control Point 2 Carl Wentzell ICF PUTNAM COUNTY Putnam County - Warning Point Michele Sturman FEMA Putnam County Emergency Operations Center Mabel Santiago (TL)

FEMA Michael Shuler FEMA Region III Michele Sturman FEMA Cheryl Weaver ICF Putnam County Accident Assessment Korky Dulgerian FEMA Putnam County - Field Monitoring Team Alpha Earl Shollenbei"Ker ICF Putnam County - Field Monitoring Team Bravo Michael DeBonis USEPA Putnam County - General Population Reception Ron Biernacki ICF Gary Goldberg ICF Center - George Fischer Middle School

  • 50

Putnam County - General Population Reception Ron Biernacki ICF Center - Carmel High School

  • Gary Goldberg ICF Putnam County Traffic Control Point 2 Robert Duggleby ICF Putnam County Traffic Control Point Robert Duggleby ICF ROCKLAND COUNTY Rockland County Emergency Operations Center Chris Cammarata(TL)

FEMA Paul Anderson FEMA Region IX Todd Sniffin ICF Larry_ Visnies~

ICFI Rockland County - Warning Point Paul Anderson FEMA Region IX Rockland County Accident Assessment Joe Keller ICF Rockland County - Field Monitoring Team 1 Nidal Azzam EPA Rockland County - Field Monitoring Team 2 Ronald Biernacki ICF Rockland County - Transportation Dependant Bus Korky Dulgerian FEMA Company - Chestnut Ridge Transit

  • Rockland County - General Population Bus Mabel Santiago FEMA Company - Student Bus Company
  • Rockland County - School Interview - Rockland Bill Cullen FEMA Work Site Day Care
  • Rockland County - School Interview - Robin Hill Bill Cullen FEMA Nursery School
  • Rockland County - School Interview - Valley Bill Cullen FEMA Cottage School
  • Rockland County - School Interview - Willow Bill Cullen FEMA Grove Middle School Rockland County - School Interview - Woodglen Mabel Santiago FEMA Elementary School
  • Chris Cammarata FEMA Rockland County Traffic Control Point Danny Loomis ICF Rockland County Traffic Control Point 2 Danny Loomis WESTCHESTER COUNTY Westchester Coun!y - Warning Point John Flynn ICF Westchester County Emergency Operations Center Brian Hasemann FEMA Scott Hallett FEMA HQ Russell Fox FEMA Richard McPeak ICF Westchester County Accident Assessment Daryl Thome ICF Westchester County - Field Monitoring Team HD-Jeanette Eng EPA 1

Westchester County - Field Monitoring Team HD-Michael Leal ICF 2

Westchester County Call Center Robert Noecker ICF Westchester County - School Bus Company - Mile Mabel Santiago FEMA Square School Bus

  • Westchester County - School Bus Company -

Mabel Santiago FEMA 51

White Plains School Bus

  • Westchester County - School Interview - Royal Mabel Santiago FEMA Coach
  • Westchester County Traffic Control Point Rebecca Fontenot FEMAHQ Westchester County Traffic Control Point 2 Rebecca Fontenot FEMAHQ BERGEN COUNTY Bergen County Emergency Operations Center Kent Tosch (TL)

ICF Meg Swearingen ICF

  • Out of Sequence Demonstration 52

APPENDIX 3:

EXERCISE OBJECTIVES AND EXTENT OF PLAY FINAL OFF SITE EXTENT OF PLAY FOR THE SEPTEMBER 14, 2010 INDIAN POINT ENERGY CENTER - UNIT 2 FULL-PARTICIPATION EXERCISE 53

EXTENT-OF-PLAY GROUND RULES 54

EXTENT-OF-PLAY GROUND RULES REAL LIFE EMERGENCIES TAKE PRIORITY OVER EXERCISE PLAY.

The Scenario Development Team will develop the "Exercise" free play messages. The State Controller will inject these messages for action as agreed upon.

"Optional" messages will be developed and inserted to facilitate EOC participation.

The Scenario Development Team will develop "Exercise" free play messages for Public Inquiry conducted at the New York State Tax and Finance Call Center in Albany, NY and at the Westchester County Alternate Emergency Operations Center/MOB in White Plains, NY. Public Inquiry messages will be injected to the two call centers by a control cell(s}.

The Scenario Development Team will develop "Exercise" free play messages for Media Inquiry. Media Inquiry messages will be injected to the State and county EOCs by a control cell(s).

The State Controller will provide radiological data for any radiological field activities (e.g.,

Field Teams, Emergency Worker Personnel Monitoring Centers, Reception Centers, etc.).

According to REP Program Strategic Review Initiative 1.5, "During tabletop exercises, drills and other demonstrations conducted out-of-sequence from an integrated exercise, if FEMA and the offsite response organizations (ORO) agree, the FEMA Evaluator may have the participants re-demonstrate an activity that is determined to be not satisfactorily demonstrated. Immediate correction of issues in an integrated exercise is authorized only if it would not be disruptive and interrupt the flow of the exercise and affect other Evaluation Areas." This initiative is not applicable to EOC/JIC/EOF demonstrations during the September 14,2010 exercise.

The following criteria, which deal with ingestion pathway, relocation, re-entry and return, post-plume phase and lab operations, will not be demonstrated:

2.d.1 2.e.1 3.e.1 3.e.2 3.f.1 4.b.1 4.c.1 55

EXTENT OF PLAY 56

EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.a - Mobilization Criterion 1.a.1: OROs use effective procedures to alert, notify, and mobilize emergency personnel and activate facilities in a timely manner. (NUREG-0654, A.4; 0.3, 4; E.1, 2; H.4)

WARNING POINTS Extent-of-Play Agreement:

The latest quarterly revised call lists will be provided at the Federal/State evaluators briefing session the day before the exercise, if requested by FEMA. The lists will contain the business telephone numbers only.

EOCs Extent-of-Play Agreement:

State liaisons will be pre-positioned in the area and will arrive at County EOCs 30 minutes after receiving notification to activate via pager or other means.

Licensee Technical Liaisons will be pre-positioned in the area and will arrive at the State and county EOCs 30 minutes after receiving notification to activate via pager or other means.

EOF Extent-of-Play Agreement:

State liaisons will be pre-positioned in the area and will arrive at the EOF 30 minutes after receiving notification to activate via pager or other means.

57

Extent-of-Play Agreement:

State JIC Staff will be pre-positioned in the area and will arrive at the JIC no sooner than 30 minutes after receiving notification to activate via pager or other means.

58

EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.b - Facilities Criterion 1.b.1: Facilities are sufficient to support the emergency response.

(NUREG*0654, H.3)

Extent-of-Play Agreement:

There is a new EOC in Bergen County. This is the only facility to be evaluated under this criterion.

59

EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.c - Direction and Control Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible. (NUREG-0654, A.1.d; A.2.a., b.)

Extent-of-Play Agreement:

The State Controller will inject "Exercise" messages for action as agreed upon.

60

EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.d - Communications Equipment Criterion 1.d.1: At least two communication systems are available, at least Qne operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations. (NUREG-0654, F.1, 2).

Extent-of-Play Agreement:

A back up to commercial telephones or radios will be demonstrated between the State and four Risk County EOCs as per the County REP Plan. Back-up means may include RACES, cell, satellite, VOIP phones, email, etc. The State Controller, along with the FEMA evaluator, will prompt this demonstration during an agreed upon time during the exercise.

An alternate to the Executive Hotline may be used to coordinate protective action decisions (PADs) among the Risk Counties and State if needed.

61

EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.e - Equipment and Supplies to Support Operations Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI),

and other supplies are sufficient to support emergency operations. (NUREG-0654, H.7, 10; J.10.a, b, e, J.11; K.3.a)

Extent-ot-Play Agreement:

Maps and displays will vary with each facility and may include hard copy printouts and listings and electronic displays.

The instruments that are used for field monitoring are the RO-20 (Gamma and Beta-mR/hr or R/hr) or equivalent and RM-14 (Gamma and Beta - GPM) or equivalent.

Field team equipment is calibrated by IPEG's RP Department. An internal IPEG requirement provides for calibration of this equipment every six months. Therefore, the calibration sticker for this equipment shows a "calibration due date" which reflects the six month calibration schedule. The instruments are considered calibrated as long as the current date is within one year of the calibration date.

General Atomics electronic dosimeters are calibrated every 3 years as per manufacturers' specifications.

No equipment (e.g., barriers, traffic cones, signs, etc.) will be deployed to the field with the exception of Field teams, Reception Centers and EWPMCs.

62

EVALUATION AREA 2: PROTECTIVE ACTION DECISION-MAKING Sub-element 2.a - Emergency Worker Exposure Control Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to insure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.

(NUREG-0654, J.10.e, f; K.4)

Extent-of-Play Agreement:

All activities will be based on the OROs' plans and procedures as they would in an actual emergency.

63

EVALUATION AREA 2: PROTECTIVE ACTION DECISION-MAKING Sub-element 2.b. Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data, and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions. (NUREG-0654, 1.8, 10 and Supplement 3).

Extent-of-Play Agreement:

In the event of a simulated radiological release, the licensee field teams will obtain plume centerline data.

64

EVALUATION AREA 2: PROTECTIVE ACTION DECISION-MAKING Sub-element 2.b. Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy). (NUREG-0654, J.9, 10.f, m).

Extent-of-Play Agreement:

All activities will be based on the OROs' plans and procedures as they would in an actual emergency.

65

EVALUATION AREA 2: PROTECTIVE ACTION DECISION-MAKING Sub-element 2.c - Protective Action Decisions Consideration for the Protection of Special Populations Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups. (NUREG-0654, J.9, J.10.d, e)

Extent-of-Play Agreement:

All activities will be based on the OROs' plans and procedures as they would in an actual emergency.

66

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.a - Implementation of Emergency Worker Exposure Control Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart. (NUREG-0654, K.3.a, b)

Extent-of-Play Agreement:

All activities will be based on the OROs' plans and procedures as they would in an actual emergency.

General Atomics electronic dosimeters are calibrated every 3 years as per manufacturers' specifications.

67

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.b - Implementation of KI Decision Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals is maintained. (NUREG-0654, J.10. e)

Extent-of-Play Agreement:

All activities will be based on the OROs' plans and procedures as they would in an actual emergency.

The post distribution ot KI to the public will also be discussed at reception centers when demonstrated as per the Offsite Extent-ot-Play Activities Schedule.

68

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.c - Implementation of Protective Actions for Special Populations Criterion 3.c.1: Protective action decisions are implemented for special populations other than schools within areas subject to protective actions. (NUREG-0654, J.10.c, d, g).

EOC ACTIVITIES:

TRANSPORTATION DEPENDENT POPULATION Extent-of-Play Agreement:

During the exercise, there will be initial contact with the transportation providers (telephone call) by the Transportation Coordinator. Initial contacts will be actual and some follow-up contacts may be simulated. All calls will be logged at each EOC.

NOTIFICATION OF HEARING IMPAIRED Extent-of-Play Agreement:

Jurisdiction Extent-ot-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Westchester The hearing-impaired County list will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact hearing-impaired individuals will be discussed with the federal evaluator at the EOC.

69

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Rockland The hearing-impaired County list will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact hearing-impaired individuals will be discussed with the federal evaluator at the EOC.

Orange The hearing-impaired County list will be available for review at the county EOG. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact hearing-impaired individuals will be discussed with the federal evaluator at the EOG.

Putnam The hearing-impaired County list will be available for review at the county EOG. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact hearing-impaired individuals will be discussed with the federal evaluator at the EOG.

70

NON-INSTITUTIONALIZED MOBILITY IMPAIRED INDIVIDUALS Extent-ot-Play Agreement:

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Westchester The list of non-County institutionalized mobility-impaired will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact non-institutionalized mobility-impaired individuals will be discussed with the federal evaluator at the EOC.

Rockland The list of non-County institutionalized mobility-impaired will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact non-institutionalized mobility-impaired individuals will be discussed with the federal evaluator at the EOC.

71

Jurisdiction Extent-ot-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Orange The list of non-County institutionalized mobility-impaired will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact non-institutionalized mobility-impaired individuals will be discussed with the federal evaluator at the EOC.

Putnam The list of non-County institutionalized mobility-impaired will be available for review at the county EOC. This list will be reviewed but not copied or retained by the Federal evaluator.

(X)

The procedure to contact non-institutionalized mobility-impaired individuals will be discussed with the federal evaluator at the EOC.

72

SPECIAL FACILITIES Extent-ot-Play Agreement:

During the exercise, there will be initial contact with the special facilities (telephone call). Initial contacts will be actual and some follow-up contacts may be simulated. All calls will be logged at each EOC.

FIELD ACTIVITIES:

EVACUATION OF TRANSPORTATION DEPENDENT POPULATION Extent-ot-Play Agreement:

Jurisdiction Extent-ot-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Westchester Bus companies will Group interviews County be interviewed as per requested the Offsite Extent-of-Play Activities Schedule. Each company will provide (X) a supervisor/

dispatcher and 5 -

10% (minimum of 2) of that company's drivers for interviews.

Rockland Bus companies will Group interviews County be interviewed as per requested the Offsite Extent-of-Play Activities Schedule. Each company will provide (X) a supervisor/

dispatcher and 5 -

10% (minimum of 2) of that company's drivers for interviews.

Orange Bus companies will Group interviews County be interviewed, requested procedures will be reviewed and equipment will be inspected. Each company will provide (X) a supervisor/

dispatcher and at least 5-10%

(minimum of 2) of that company's drivers for interview.

73

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Putnam Bus companies will Putnam 'county County be interviewed, proposes to procedures will be demonstrate with school reviewed and administrator, equipment will be dispatcher and driver(s).

inspected. Each (X) company will provide Also proposes a supervisorl interviews of General dispatcher and 5-10%

Population and School (minimum of 2) of that Bus concurrently.

company's drivers for interview.

NOTIFICATION OF HEARING IMP AIRED Extent-at-Play Agreement:

There will be no actual notification of hearing-impaired individuals during the exercise.

EVACUATION OF NON-INSTITUTIONALIZED MOBILITY IMP AIRED INDIVIDUALS Extent-at-Play Agreement:

There will be no actual dispatch of vehicles for transport of non-institutionalized mobility-impaired individuals.

There will be no actual contact of non-institutionalized mobility-impaired individuals identified on the list.

74

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.c - Implementation of Protective Actions for Special Populations Criterion 3.c.2: OROs/School officials implement protective actions for schools.

(NUREG-0654, J.10.c, d, g).

EOC ACTIVITIES:

Extent-of-Play Agreement:

During the exercise, there will be initial contact with the schools and transportation providers (telephone call or auto-dialer) by the School and Transportation Coordinators. Initial contacts will be actual and some follow-up contacts may be simulated. All calls will be logged at each EOC.

FIELD ACTIVITIES:

EVACUATION OF SCHOOL POPULATIONS Extent-of-Play Agreement:

Bus companies will be interviewed as per the Offsite Extent-Of-Play Activities Schedule.

Each company will provide a supervisor/dispatcher and 5-10% (minimum of 2) of that company's drivers for interview.

SCHOOL INTERVIEWS Extent-of-Play Agreement:

The minimum number of schools/licensed day care providers/private schools (one school per district) to be interviewed per the Offsite Extent-Of-Play Activities Schedule is as follows:

Westchester County - The County will schedule interviews with public schools which were not visited by FEMA as a part of the 2008 (PEC exercise. The County will also work cooperatively with New York State to schedule a group interview with non-public schools and/or day care providers within the Westchester County EPZ.

Rockland County - 5 schools 75

Orange County - 1 school Putnam County - 3 schools Additional interviews of schools and school reception centers (baseline evaluations 2008-2013) will be conducted as agreed to by FEMA, NYSEMO and each county EMO.

Interviews for schools within the same district may be conducted with school administrators at a scheduled district meeting.

76

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.d. - Implementation of Traffic and Access Control Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel. (NUREG-0654, J.10.g, j)

TRAFFIC AND ACCESS CONTROL POINTS (TCPs and ACPs)

Extent-of-Play Agreement:

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Westchester There will be two (2)

County interviews of law enforcement officials to discuss how to activate TCPs!ACPs.

Each deSignated law enforcement agency will provide one (1) officer. The State (X)

Controller will provide a free play message to select the TCP!

ACP assigned to that agency to be discussed. The interviews will take place at the EOC.

Rockland There will be two (2)

County interviews of law enforcement officials to discuss how to activate TCPs!ACPs.

Each designated law enforcement agency will provide one (1) officer. The State (X)

Controller will provide a free play message to select the TCP!

ACP assigned to that agency to be discussed. The interviews will take place at the EOC.

77

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Orange There will be two (2)

County interviews of law enforcement officials to discuss how to activate TCPs/ACPs.

Each designated law enforcement agency will provide one (1) officer. The State (X)

Controller will provide a free play message to select the TCPI ACP assigned to that agency to be discussed. The interviews will take place at the EOC.

Putnam There will be two (2)

County interviews of law enforcement officials to discuss how to activate TCPs/ACPs.

Each designated law enforcement agency will provide one (1) officer. The State (X)

Controller will provide a free play message to select the TCPI ACP assigned to that agency to be discussed. The interviews will take place at the EOC.

78

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.d. - Implementation of Traffic and Access Control Criterion 3.d.2: Impediments to evacuation are identified and resolved. (NUREG-0654, J.10.k).

IMPEDIMENTS TO EVACUATION Extent-of-Play Agreement:

Each of the four 10-mile plume exposure pathway EPZ counties is to demonstrate the organizational ability to deal with at least two (2) impediments to evacuation.

The State Controller will inject "Exercise" messages for action as agreed upon.

No equipment (Barriers, Traffic cones, Signs, etc.) will be deployed to the field.

This demonstration will not involve the dispatch of a police or other emergency vehicle to the scene of a simulated impediment. Initial contact of resource providers and some follow-up contacts may be simulated. All calls will be logged at each EOC.

79

EVALUATION AREA 4: FIELD MEASUREMENT AND ANALYSIS Sub-element 4.a - Plume Phase Field Measurements and Analyses Criterion 4.a.1: The field teams are equipped to perform field measurements of direct radiation exposure (cloud and ground shine) and to sample airborne radioiodine and particulates. (NUREG-0654, H.10; 1.7,8,9)

FIELD MONITORING TEAMS Extent-of-Play Agreement:

The monitoring teams will not be suited up in anti-contamination clothing. However, the clothing will be 'available for inspection. The initial use of gloves will be demonstrated.

Field team equipment is calibrated by IPEG's RP Department. An internal IPEG requirement provides for calibration of this equipment every six months. Therefore, the calibration sticker for this equipment shows a "calibration due date" which reflects the six month calibration schedule. The instruments are considered calibrated as long as the current date is within one year of the calibration date.

80

EVALUATION AREA 4: FIELD MEASUREMENT AND ANALYSIS Sub-element 4.a - Plume Phase Field Measurements and Analyses Criterion 4.a.2: Field teams are managed to obtain sufficient information to help characterize the release and to control radiation exposure. (NUREG-0654, H.12; 1.8, 11; J.10.a)

Extent-of-Play Agreement:

In the event of a simulated radiological release, the licensee field teams will obtain plume centerline data.

81

EVALUATION AREA 4: FIELD MEASUREMENT AND ANALYSIS Sub-element 4.a - Plume Phase Field Measurements and Analyses Criterion 4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected.

Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media. (NUREG-()654, 1.9).

FIELD MONITORING TEAMS Extent-of-Play Agreement:

Each EPZ County will dispatch two (2) radiological monitoring teams. Each team will be supplied with a State Controller and FEMA evaluator.

The monitoring teams will not be suited up in anti-contamination clothing. However, the clothing will be available for inspection. The initial use of gloves will be demonstrated.

Each team will take at least six (6) ambient radiation measurements (including background measurements) and at least two (2) air samples. All teams must take the air samples as though they were in the presence of the plume including County teams that may not be impacted by the plume. If necessary, an inject message from the State Controller may be used to complete the taking of all six measurements prior to the end of the exercise.

The use of silver zeolite cartridges will be simulated and charcoal cartridges will be used. However, the silver zeolite cartridges will be available at dispatch point of kit.

There will be no actual packaging or transport of samples to the laboratory. EOC staff will be questioned only regarding means of transportation of air samples to a central point and the location of the laboratory. Field teams will demonstrate how to obtain air samples during the exercise and will be questioned only regarding the procedures for the pick-up point of air samples and chain of custody.

Eating, drinking, and smoking will be allowed after concurrence of the FEMA evaluator.

82

EVALUATION AREA 5: EMERGENCY NOTIFICATION & PUBLIC INFORMATION Sub-element 5.a - Activation of the Prompt Alert and Notification System Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance. (10 CFR Part 50, Appendix E.lV.D &

NUREG-0654, E.5, 6, 7)

Extent-of-Play Agreement:

There will be no actual sounding of sirens and no actual broadcasting of EAS messages. The Indian Point siren system will be tested during 2010. FEMA will be invited to observe the tests at those times.

To demonstrate the procedures for siren activation, all counties will conduct an actual "Silent" test (no siren sounding) in conjunction with an EAS message broadcast (simulated) during the exercise.

One (1) complete alerting and notification sequence will be evaluated. This sequence will include simulation of siren activation, preparation and transmission of a simulated EAS message to the LP-1 radio station. There will be actual telephone contact with the radio station for one (1) simulated EAS message which contains protective actions. Contact with the radio station for all other EAS messages may be simulated.

Airing of the all EAS messages will be simulated.

Regular programming responsibilities of the radio station may preclude participation at the time of the issuance of the simulated EAS message.

All simulated EAS messages will be available via the JIC website.

83

EVALUATION AREA 5: EMERGENCY NOTIFICATION & PUBLIC INFORMATION Sub-element 5.a - Activation of the Prompt Alert and Notification System Criterion 5.a.3: Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system. (NUREG-0654, E. 6, Appendix 3.B.2.c).

Extent-of-Play Agreement:

To demonstrate the procedures for siren activation, all counties will conduct an actual "Silent" test (no siren sounding) in conjunction with an EAS message broadcast (simulated) during the exercise.

The results of the initial "Silent" test will be used to discuss backup alerting by the telephone call-out system for sirens that have been simulated to fail. Subsequent silent tests if conducted by the counties will not be evaluated.

An inject message(s) to simulate siren failures will be used if no sirens appear to have failed on the "Silent" test.

Demonstration of this criterion will be limited to two (2) actual "Silent" test failures or two (2) simulated siren failures per county.

Jurisdiction Westchester County Rockland County Extent-of-Play EOC discussion only, after "Silent" test.

The county's telephone call-out system will be demonstrated to notify an area impacted by a simulated siren failure.

EOC discussion only, after "Silent" test.

In Sequence With Exercise (X)

(X)

(X)

Out of Out of Sequence; Sequence; Comments Day of NOT Day of Exercise Exercise A small test group will be used for demonstration.

The county's A small test group will telephone call-out be used for system will be demonstration.

demonstrated to notify an area impacted by a simulated siren failure.

(X) 84

Jurisdiction Extent-of-Play In Out of Out of Sequence Sequence; Sequence; Comments With Day of NOT Day of Exercise Exercise Exercise Orange EOC discussion after (X)

County "Silent" test.

The county's A small test group will telephone call-out be used for system will be demonstration.

demonstrated to (X) notify an area impacted by a simulated siren failure.

Putnam EOC discussion after (X)

County "Silent" test.

The county's A small test group will telephone call-out be used for system will be demonstration.

demonstrated to (X) notify an area impacted by a simulated siren failure.

85

EVALUATION AREA 5: EMERGENCY NOTIFICATION & PUBLIC INFORMATION Sub-element ~.b - Emergency Information and Instructions for the Public and the Media Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner. (NUREG-0654, E. 5, 7; G.3.a, G.4.c).

PUBLIC INSTRUCTION AND EMERGENCY INFORMATION Extent-of-Play Agreement:

The preparation and transmission of EAS Follow-On News Releases (at least one for each county, if applicable) following an EAS message containing protective actions, may be actually distributed to the LP-1 EAS radio station via the JIC website.

The EAS Follow-On News Releases from each county may not necessarily apply to the same EAS Message.

Westchester County will also post News Releases (and EAS messages) to the county "Exercise" website.

All simulated EAS Follow-On News Releases will be available to the media via the JIC website.

EMERGENCY INFORMATION Extent-of-Play Agreement:

At least two (2) media briefings will be conducted and evaluated. The briefings to be evaluated will be selected by a State Controller with concurrence from the lead JIC FEMA evaluator. Preparation and scheduling activities for all media briefings will be conducted in accordance with the JIC procedures.

AudioNideo conference links from the County EOCs to the JIC will be utilized for media briefings.

PUBLIC INQUIRY Extent-of-Play Agreement:

The public inquiry function will be staffed for evaluation at two (2) locations:

the New York State Tax and Finance Call Center in Albany (-6 people including a supervisor) and the Westchester County Public Inquiry Call Center at the Alternate 86

EOC in White Plains (-6 people including a supervisor).

Inject messages will indicate false or misleading information to enable the public inquiry function to identify trends and false rumors at both locations.

Coordination of trends and false information will be conducted on the PIO Coordination line.

Media Monitoring will be conducted at the JIC.

Callbacks from the NYS Tax and Finance Call Center in Albany may be simulated.

87

EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES SUb-element 6.a - Monitoring and Decontamination of Evacuees and Emergency Workers, and Registration of Evacuees Criterion 6.a.1: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers.

(NUREG-06S4, J.10.h; J.12; K.S.a)

Extent-of-Play Agreement:

Reception centers will be demonstrated as per the offsite extent of play activities schedule. Additional reception centers will be evaluated (baseline evaluations 2008-2013) as agreed to by FEMA, NYSEMO and each county EMO.

At least six (6) simulated evacuees will be monitored.

Initial personnel monitoring staff will be demonstrated as tabulated below. Staff will be provided to simulate evacuees.

Number of Persons for Initial Personnel Monitoring Category Orange Rockland Westchester Putnam County County County County Radiological monitors 3

3 3

2 for initial monitoring (See Note 4)

(See Note 4)

(See Note 4)

(See Note 1)

Other Personnel 0

0 0

(See Note 5)

(See Note 2)

(See Note 5) 0 (See Note 3)

No. of Portal Monitors 2

2 2

1 Note 1: One monitor for portal monitoring; one monitor for hand held monitoring.

Note 2:

Evacuees will be monitored, then either given a "clean" card or directed to decontamination area.

Note 3: Evacuees will be monitored, then either hand-stamped clean or directed to decontamination area.

Note 4:

Two monitors for portal monitOring and 1 monitor available for hand held monitoring.

Note 5: Evacuees will be monitored, then directed to a "clean" area or to decontamination area.

The number of decontamination personnel, vehicle monitoring/decon personnel and social services personnel demonstrating this criterion will be in accordance with each county's plans and procedures.

Vehicle monitoring will be conducted in accordance with plans.

There will be only a representative sample of supplies available at each facility.

88

Outside activities (vehicle monitoring/decon) may be demonstrated at different dates/times from inside activities (personnel monitoring and decon, social services, etc.)

As necessary, decontamination techniques will be simulated. At the PMC, activities that may damage property (such as parking vehicle on grass) are to be simulated.

The monitoring and decontamination teams will not be suited up in anti-contamination clothing. However, all required materials will be available for inspection. The initial use of gloves will be demonstrated.

Reception Center floors may be covered with a representative sample of paper/plastic during this demonstration. However, all required materials will be available for inspection.

One decon area will be set up and used to demonstrate both male and female decontamination technique by appropriate personnel.

Portal monitors will be operated in accordance with each county's procedures.

Portal monitors are checked with a check source to verify operability and the capability to meet the FEMA portal monitor standard (11JCi Cs-137 at midline).

Monitoring and decontamination capabilities for a school reception center (Rockland County only) will be demonstrated as per the Offsite Extent-of-Play Activities Schedule.

The post distribution of KI to the public will also be discussed at reception centers when demonstrated as per the Offsite Extent-of-Play Activities Schedule.

89

EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES Sub-element 6.b - Monitoring and Decontamination of Emergency Worker Equipment Criterion 6.b.1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles. (NUREG-0654, K.5.b)

Extent-or-Play Agreement Emergency Worker Personnel Monitoring Centers (EWPMC)will be demonstrated as per the offsite extent-of-play agreement schedule.

Each facility will demonstrate the following:

At least two (2) monitors for personnel decontamination (1 male and 1 female);

At least one (1) monitor for vehicle monitoring; At least one (1) monitor for vehicle decontamination.

The monitoring and decontamination teams will not to be suited up in anti-contamination clothing. However, all required materials will be available for inspection. The initial use of gloves will be demonstrated.

Decontamination actions are to be simulated. At the PMC, activities that may damage property (such as parking vehicles on grass) are to be simulated.

EWPMC floors may be covered with a representative sample of paper/plastic during this demonstration. However, all required materials will be available for inspection.

One (1) portal monitor for personnel monitoring will be demonstrated by Rockland County. The other counties will not demonstrate EWPMCs for this exercise.

One decon area will be set up and used to demonstrate both male and female decontamination technique by appropriate personnel.

The Portal monitor will be operated in accordance with each county's procedures.

Portal monitors are checked with a check source to verify operability and the capability to meet the FEMA Portal Monitor standard (1 uCi Cs-137 at midline).

90

EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES Sub-element 6.c - Temporary Care of Evacuees Criterion 6.c.1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines (found in MASS CARE-Preparedness Operations, ARC 3031). Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities. (NUREG-0654, J.10.h, J.12).

Extent-of-Play Agreement:

There are no new centers or configuration changes to existing centers. This criterion will not be evaluated in this exercise.

91

EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES Sub-element 6.d - Transportation and Treatment of Contaminated Injured Individuals Criterion 6.d.1: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals. (NUREG-0654, F.2; H.10; K.S.a, b; L.1, 4)

Extent-of-Play Agreement:

MS-1 drills for the four EPZ counties will be conducted as per the Offsite Extent-Of-Play Activities Schedule.

The use of flashing lights and sirens for exercise play is not required.

92

APPENDIX 4.

2010 INDIAN POINT ENERGY CENTER EXERCISE SCENARIO Exercise Commences:

Entergy Nuclear Northeast Indian Point Energy Center Unit 2 FEMINRC Exercise September 14, 2010 0830 - Operations Drill Team assumes the Watch.

0830 - Inadvertent turbine trip and a failure of automatic Reactor trip signal occurs.

Operations will attempt to manually trip the reactor and will be successful.

0845 - An Alert should be declared based on EAL 1. I.} "Any failure of and automatic trip signal to reduce power range < 5% and manual trip is successful".

Site assembly alarms will not be sounded. Emergency Response Facilities will be requested to be activated with exercise participants only and protected area non-essential personnel will remain in their work locations. Accountability will be simulated.

0945 - Bus 3A de-energizes due to ground fault.

1100 - 1045 Chemistry sample returns with the coolant Dose Equivalent Iodine (DE I) reading -330 UCi/cc.

1130 - LOCA occurs. 23 FCU goes out of service due to closing coil failure on the breaker and 22 Spray Pump goes out of service due to winding short on the motor. Containment isolation valve 201 is mechanically bound and will not close on Containment Isolation signal. During implementation of E-l Loss of Reactor or Secondary Coolant, the operators will attempt to reset the Containment Isolation Signal and will need to use the key bypass switches to reset the signal. Once the Containment Isolation signal is reset Containment Isolation valve 1228 will open and Instrument Air will be established to containment. Letdown isolation valve LCV -459 and Letdown Orifice isolation valve 200C will open. Attempts to isolate valves from the Control Room will not be successful.

93

Note: LOCA to occur when RCS temperature reaches 520 degrees even if time has not been reached. This may change time for declaration.

1145 - GE should be declared based on EAL 4.1.4 "Confirmed Phase "8" isolation signal following confirmed LOCA with less than minimum containment cooling safeguards equipment operating, Table 4.3 AND any indicators of fuel clad loss, Table 4.1".

1205 - Radiation Monitors R2, R7 and R25126 begin to increase. R25126 will continue to increase to 2250 Rlhr.

1245 - A break in the Letdown line between valves 201 and 202 will result in an RCS leak outside Containment into the Primary Auxiliary Building. Plant Vent Radiation Monitor R27 readings reach 518 dis (6750 cpm) indicating an airborne release in progress above federal limits.

1430 - Release is terminated by either 200C or LCV-459 being successfully isolated.

1530 - After consultation with the Offsite Exercise Controller Organization, the Exercise will end after all objectives have been given ample opportunity for demonstration by BOTH onsite and offsite responders.

94

APPENDIX 5.

PLANNING ISSUES NEW YORK STATE ISSUE NO: 32-1O-5.b.l-P-01 ISSUE: A process does not currently exist to address incomplete or inaccurate information posted on the JIC website.

RECOMMENDATION: Modify the section on page 6 of the Indian Point Joint Information Center Plan, "News Releases and Media Advisories/Deleting Press Releases".to include the actions the NY State Office of Emergency Management needs to take when a press release containing incomplete or inaccurate information has been posted to the He website, to include specific clarification as to why the release was deleted and any new andlor revised information.

ORANGE COUNTY ISSUE NO: 32-10-4.a.3-P-02 ISSUE: Procedure 22, Field Radiological Monitoring Revised 7110, Paragraph IV B 2 a) (1) and paragraph IV C 2 f), refer to the plume boundary being defined by an RO-20 meter reading of 1-2 mRlhr. Though a team reading 1-2 mRlhr on their instruments may very well be immersed in the plume, it may also be receiving that exposure from shine while being below or horizontal to the plume.

The teams' instructions to take open window and closed window readings before, during, and after air sampling will indicate whether or not the team was within the plume. However, the team does not have instructions in the plan to compare the readings to assure that the plume is being sampled. As Procedure 22 is currently written, the answer to any questions verifying that a Field Team is actually sampling within the plume is null.

RECOMMENDATION: The plan should state a criterion and instruct the teams to use that criterion that assures that the sampling point is in the plume. As an example, the plan could specify that the open window reading should exceed the closed window reading by a certain percentage.

ISSUE NO: 32-10-4.a.3-P-04 ISSUE: Procedure 22 in the Orange County Radiological Emergency Response Plan contains on page 22-10 a reference to the Field Monitoring Air Sampling Sequence Form. This is, according to the note containing the reference, the form upon which the air sample results are to be recorded. No such form was available to Orange County Field Monitoring Team 2, and the team leader was not aware that any such form existed. All data was recorded on the Monitoring Data Log form, which was more than adequate for the purpose. The reference to the nonexistent form should be removed from Procedure 22.

95

RECOMMENDATION: Change the text in Procedure 22,Section IV.C.3.b)(4)(d) to reference the Orange County Monitoring Data Log rather than the Air Sampling Sequence Form.

ISSUE NO: 32-1O-2.b.l-P-05 ISSUE: Projected doses were incorrectly calculated by staff in the Orange County Emergency Operations Center (OCEOC) using the manual method detailed on Form #14 Assessment Worksheet No.2 of Procedure 21 of the Orange County Radiological Emergency Response Plan (OCRERP).

RECOMMENDATION: Modify Procedure 21 of the Orange County Radiological Emergency Response Plan, Assessment Worksheet Number 2 Form #14, page 21-2 to clarify "Note 2" and remove Table K2 since information on this table is not used on this Form.

ISSUE NO: 32-10-3.c.2-P-06 ISSUE: There are students in the Cornwall CSD and the Monroe Woodbury CSD, the John S. Burke Catholic High School and the Orange Ulster BOCES who live inside the EPZ but go to schools that are outside the EPZ. When the Orange County portion of the EPZ was evacuated these students were retained at their schools to be picked up by their parents. Further conversation with the Schools Coordinator indicated that such retention would be the case for any such evacuation. Also parents had received information to this effect from their children's school and would be informed by media broadcasts during such an event, were it to occur. However, the 2009-2010 Orange County Indian Point Emergency Guide tells parents that many schools have plans in place for parents to pick up students before they are relocated and to check with the principal of one's children's schools about such plans. It also has a box with orange background, which states, "The school reception center for Orange County is South Jr. High School, 33-63 Monument St. Newburgh, NY. Refer to the foldout map for more information. TV and Radio broadcasts will keep you informed about the relocation of students to the school reception center." But it does not indicate that students living inside the EPZ going to schools outside it will be retained at their school for pick up. This could lead to confusion by some parents as to the proper action to take.

RECOMMENDATION: Add information in the Orange County Indian Point Emergency Guide orange box that all students at schools outside the EPZ will be retained at their schools.

ISSUE NO: 32-10-3.d.l-P-07 ISSUE: The TCPs are to be set up atBAE according to the Procedure 2 Law Enforcement 4.6.1.2.

"The Sheriff, in conjunction with the State Police and local Police Departments, will order the establishment of traffic control checkpoints at the following locations to prevent unnecessary traffic from entering the lO-mile EPZ (see Table 7 A of Appendix H)." There are twenty TCPs in this table.

Establishment of these TCPs involves from 3 to 16 cones at 18 checkpoints, and 8 barricades and a sign at the other two. At least some of these supplies are supposed to be provided by the Orange County Department of Public Works. However, their procedure is not quite consistent with the above.

Procedure 7 Public Works 5. SAE 5.1.3 "The County Commissioner of Public Works will make available to law enforcement agencies any requested resources that can be spared (e.g. equipment, barricades etc.) to support the establishment of traffic control points.

96

"Rather than wait for the request the barricades, at least, should be put in place at SAE or EAS message, whichever is earlier. Cones, if needed could be provided to the police at their departments to take into the field. This procedure should also cite Table 7 A. There are 10 Access Control Points to the EPZ (Table 7B of Appendix H) Six of these are also TCPs. The ten ACPs require 51 barriers and 3 signs. There is a reference to acce~s control along the evacuation route (Table 2 of Appendix H).

However, that table makes no reference to ACPs. These are to be established in the event of an evacuation according to both the police and DPW procedures. With the barricades and signs to be provided if requested according to the DPW evacuation procedure (General Evacuation Procedure 1.A.3). Waiting for these requests, which would occur as the ACPs began to be staffed would delay their effectiveness. Additional ACPs along the evacuation route are mentioned in both the Law Enforcement and Public Works procedures but none are noted in the table cited above.

RECOMMENDATION: Plan should be changed so that police are provided with enough cones to establish TCPs at Alert. If needed, cones can be dispatched to Police stations and the Sheriffs Department to be deployed to TCPs by officers assigned. The two TCPs requiring barricades and signs should be referenced in Procedure 7, Public Works, to be deployed at SAE or the first EAS message, whichever comes first. Earlier setup up could unduly alarm the public. Once these are deployed, then barricades for the ACPs should be deployed at least to the six that are also TCPs. Certainly all ACP barricades should be deployed at GE so that the ACPs can be quickly activated in the event of an evacuation. ACPs along the evacuation route are mentioned but none are noted in the Table cited. This should be rectified by citing these ACPs, omitting the reference, or stating they will be set up along the route based on circumstances.

ISSUE NO: 32-08-3.b.1-P-Ol ISSUE: While appropriate KI was available for use by emergency workers, the issuance of KI to FMTs was not in accordance with the current requirements of Procedure 24, "Exposure Control." This procedure also does not accurately reflect the intended manner of distribution of dosimetry and KI at the new Orange County EOC. Specifically, according to Procedure 24, Steps 5.2.1 and 5.2.5, issuance of dosimetry and KI to workers is the sole responsibility of the Emergency Worker Supervisor.

However, current protocol at the Orange County EOC is for FMTs to deploy directly to the new EOC and begin inventory and operational checks without necessarily interfacing with an emergency worker supervisor. In this exercise, the RACES Team members assigned to the FMTs were performing the functions of dosimetry and KI issuance. However issuance of dosimetry or KI by anyone other than the Field Team supervisor is a deviation from Procedure 24 requirements. The RACES personnel did not use or have an appropriate procedure to accomplish this task and while dosimetry was appropriately provided to Team 1, KI was not.

When questioned about KI prior to dispatch, Team 1 technical members recalled that the KI was stored in a cabinet and they proceeded to obtain sufficient KI to take to the field. It is not clear whether this would have been accomplished had the question not been asked, however the existing exposure control Procedure 24, as implemented without the field team supervisor, did not drive KI issuance by the RACES support personnel. Other KI responsibilities, including providing instructions for continued use after initial authorization to take it, and instruction on the potential allergic reactions, were also not accomplished during issuance ofKI or during the FMT briefing by the Field Team Coordinator.

97

Lastly, the Form 3, Individual Radiation Exposure Record Form does not include a place to record KI expiration, although Procedure 22 - "Field Radiological Monitoring," Step 4.2.3 requires the Field Teams to record the KI expiration date on the form. Since Procedure 22 does not address RACES team member tasks and KI issuance was being done by RACES personnel and not technical team members using Procedure 22 for operational checks, this step in the procedure was never performed and the expiration date was not recorded on the Form 3 for team 1.

CORRECTIVE ACTION DEMONSTRATED: Procedure 24, Exposure Control, revised 5/10, no longer assigns sole responsibility for dosimetry issuance to the Field Team Supervisor. Procedure 22, Field Radiological Monitoring, revised 5/10, directs the field team members to obtain an exposure control packet and provides direction for checking and for documenting personal dosimetry usage.

This was adequately demonstrated on September 14,2010.

ISSUE NO: 32-08-4.a.l-P-02 ISSUE: During the RM-14 operability check, neither the procedural instruction nor other mechanism (equipment label, etc) specified an acceptable range of readings needed to ensure the equipment was indeed operational and suitable for field use. In order to be properly tested for operability, a given instrument reading must fall within both a lower and upper range of values specific to the source being used. However Procedure 22, "Field Radiological Monitoring," states only that the Cs-137 check source must read greater than 10,000 counts per minute (cpm). No upper level is provided for which a higher reading would also indicate an equipment malfunction and no specific source is identified.

The source provided in the kit delivered only 9000 cpm and the team then borrowed a check source from another kit and found that the instrument response with this source was well over the required 10000 cpm. No upper range was evaluated since the procedure (or other instruction) did not specify one.

RECOMMENDATION: Update procedures for operational checks of equipment to include upper ranges specific to each source.

ISSUE NO: 32-08-6.d.l-P-03 ISSUE: Use of the 44-9 probe with the Ludlum Model 14 survey meter should utilize the counts-per-minute (cpm) scale for detection of contamination. This is inconsistent with the contamination decision criteria designated in the hospital procedure, which provides action levels in mRlhr. The procedure specifies survey action levels of less than 0.05 mRlhr as background, 0.005-100 mRlhr as contamination and greater than 100 mRlhr as heavy contamination.

CORRECTIVE ACTION DEMONSTRATED: Procedure IP 1018 is no longer used. Rather, the hospital has a new procedure. The new procedure, Management of the Radioactively Contaminated Patient, St Luke's-Cornwall Hospital, revised 11/2010, specifies the contamination limit as 300 cpm above background.

98

ISSUE NO: 32-08-6.d.l-P-04 ISSUE: The crew from the Cornwall Volunteer Ambulance Corps and staff at the St. Luke's Cornwall Hospital were unaware of the procedure that requires the ambulance crew to report to an Orange County Emergency Worker Personnel Monitoring Center (EWPMC) if found to be contaminated after monitoring by hospital staff.

In Attachment 9, Under Section III, Paragraph B, on page 10-23 in the Orange County RERP, it reads as follows:

For Rescue-Squad personnel:

1. Hospital personnel will perform a survey of clothing, ambulance, etc. upon arrival at the hospital before undertaking further activity.
2. If contaminated, discard clothing in container marked "Radioactive"
3. All rescue-squad personnel that are found to be contaminated should report to an activated Orange County Emergency Worker Personnel Monitoring Center.

This procedure needs more clarity on what actions is to take place on part of hospital staff and ambulance crew after the patient is discharged into the hospital's care. The procedure should state under what circumstances if any, that ambulance crew members are to be decontaminated and treated at the hospital, or "must" report to a EWPMC instead of "should".

The removal of contaminated clothing by ambulance crew members at the hospital and the sending them to a EWPMC may not be feasible due to weather conditions and temperatures, and what the clothing requirements are of the Rescue Squad.

CORRECTIVE ACTION DEMONSTRATED: The Orange County Radiological Officer has agreed with this recommendation and has revised the procedure accordingly. The updated procedure has been reviewed and approved by FEMA.

ISSUE NO: 32-08-3.a.l-P-08 ISSUE: The procedure for St. Luke's Cornwall Hospital does not adequately address exposure control for emergency workers. Radiology Policy and Procedure Number IP 1018 does not include procedures for using dosimetry, administrative reporting limits, or a decision chain for replacing emergency workers. During the event, workers were questioned regarding their dose limits. Workers reported that the dose limit was 5 R, with a reporting level of 1 R. If increasing levels of exposure were noted on the OROs, then the Radiological Safety Officer (RSO) would be consulted and would be responsible for replacing workers if necessary. This information was covered in the training session, but is not included in the procedures. Additionally, since they used a 200 mR ORO, the ORD would have to be re-zeroed four times before reaching the administrative reporting level of 1 R.

RECOMMENDATION: The procedure needs revision to include guidance on use of dosimetry, administrative dose limits, and designating an individual who is responsible for managing worker exposure control. Also, provision of higher-reading (0-20 R) self reading dosimeters in addition to the 200 mR's should be considered. Personnel should be trained on the revised procedure.

99

PUTNAM COUNTY ISSUE NO: 32-1O-6.a.l-P-09 ISSUE: When the Emergency Worker Personnel Center (EWPMC), Monitoring Station staff member detected contamination of 1000 cpm on the emergency workers jacket, he said he would send him to the Decontamination Station. Then after looking at nearby "contaminated materials" garbage can, he added that he may ask the emergency worker to remove his jacket and place it in the "contaminated materials" garbage cans and re-monitor the emergency worker.

RECOMMENDATION: It is recommended that the EWPMC procedure be revised to remove the "contaminated materials" garbage can near the monitoring station. Contaminated materials may be brought to the Decontamination Station to be disposed.

ISSUE: 32-1O-6.a.l-P-IO CONDITION: The EWPMC staff said they would bag the dosimeters and exposure records form, but they were uncertain as TO what to do with them when they referred to Procedure 4.5.

RECOMMENDATION: Modify Procedure 4, Sections 4.4, 4.5 and / or 4.9 so they are consistent and don't cause any confusion for the EWPMC staff.

ISSUE: 32-10-6.a.l-P12 CONDITION: At the male personnel decontamination point, when contamination levels were "detected" on the head and shoulders, the evacuee was directed to the sink instead of the shower.

Generally, the sink should only be use to decontaminate the hands and forearms.

RECOMMENDATION: Revise Procedure 3 to be clearer with respect to when to use the sink and when to use the shower. The sink should only be used for decontamination of the hands and forearms.

ROCKLAND COUNTY ISSUE NO: 32-10-3.b.l-P-ll ISSUE: Procedure No. DOH-II, Section 3.2 which states that "Detailed records of drug administration must be kept on the individual's Radiation Exposure Card" was not implemented because there is no such location on the Exposure Card to note time and amount of KI ingested.

RECOMMENDATION: It is recommended that the Exposure Card be revised to be consistent with the Procedure. At a minimum, the exposure cards should have the following information: the amount ingested, the name of person ingesting the KI, and date and time of KI ingestion.

ISSUE NO: 32-1O-3.b.l-P-12 ISSUE: The Dose Assessment Team Leader (DATL) announced that a list would be circulated to all 100

staff in the RCEOC for them to sign indicating that they would ingest KI. In accordance with the Extent-of Play agreement ingestion ofKI was to be simulated. The DATL also announced that those choosing not to ingest KI should notify her individually. For demonstration purposes a sleeve ofKI and copy of the informational material was distributed to the RCEOC staff. While the activities described above are adequate, there is no requirement in the current Rockland County Plan and Procedures to document the ingestion of KI by the staff in the RCEOC which is within the 10-mile EPZ.

RECOMMENDATION: Develop a form to document who ingested KI and when and include the use of this form in the appropriate DOH procedure. It is suggested that the individual TLD serial number be included with the individual's name.

ISSUE NO: 32-10-4.a.2-P-13 ISSUE: Procedure DOH-5, Attachment 4, page 22 of36 states that the field team is in the plume if the reading at the sampling site is two times background or higher. This statement is potentially incorrect.

The plume may be elevated at the sampling site and the shine may cause the ambient reading to be greater than twice background. This also holds for a plume horizontally displaced from the sampling site.

RECOMMENDATION: Replace statement in Procedure DOH-5, Attachment 4, page 22 of36 with a statement that includes making the decision that an air sample is appropriate if the open window reading is greater that the closed window reading by some percentage.

ISSUE NO: 32-08-3.b.1-P-05 ISSUE: One Rockland County Field Monitoring Team 2 (RC FMT2) team member commented that she was allergic and could not take KI. When the team was instructed by the Field Team Coordinator (FTC) to take KI the other RC FMT2 team members took their KI (simulated) and notified the FTC that they had done so. The FTC was not advised that one team member was unable to take KI.

RECOMMENDATION: Procedures should be updated to require emergency workers to report taking, or not taking, KI when instructed to do so. Procedures should also include guidance for emergency worker coordinators to take appropriate measures when an emergency worker is unable to take KI.

ISSUE NO: 32-08-2.b.2-P-06 ISSUE: The Rockland County Radiological Emergency Preparedness Plan,Section III, Rev. 07/08, page 111-25, Table III-I, states that when the projected dose to the population is 25 rem committed dose equivalent (CDE) to the thyroid from radioiodine, then the recommended action is to administer stable iodine. The projected 25 rem thyroid CDE to warrant the recommendation to ingest KI is consistent with the U.S. Food and Drug Administration (FDA) guidance found in the U.S. Environmental Protection Agency Manual of Protective Action Guides and Protective Actions for Nuclear 101

Emergencies, 1992, EPA-400-R-92-001. However, this guidance has been superseded by the FDA Guidance: "Potassium Iodide as a Thyroid Blocking Agent in Radiation Emergencies," November 2001. This guidance recommends the ingestion ofKI as a function of age and projected thyroid CDE.

It includes the recommendation to ingest KI for: Children from birth to 18 years <<70 kg in weight): >

5 rem thyroid CDE Pregnant or lactating women: > 5 rem thyroid CDE Adults 18 through 40: > 10 rem thyroid CDE Adults over 40: > 500 rem thyroid CDE Also, the policy in Table 111-1 is not consistent with the Rockland County Procedure, DOH-8 "Potassium Iodide Issue and Use," Rev 07/08, page 3, that states, "... upon declaration of a General Emergency by the licensee, a recommendation to evacuate and take KI would be made simultaneously."

RECOMMENDATION: Modify the county plan to be consistent with FOH-8 and the current FDA guidance on the projected thyroid CDE that warrants the ingestion of KI by the public.

WESTCHESTER COUNTY ISSUE NO: 32-08-1.a.l-P-1O ISSUE: The Emergency Operations Center (EOC) activation list provided to the evaluator to demonstrate quarterly updating was not the same list that was used during the exercise.

CORRECTIVE ACTION DEMONSTARTED: This criterion was re-evaluated on 09/14/10.

During the exercise, the Westchester county staff was effectively notified.

ISSUE NO: 32-08-3.a.l-P-20 ISSUE: The inventory at the School Bus Garage no longer has TLDs. Instead the TLDs were replaced with a newer technology OSL permanent record dosimeter. The new inventory is not accurately documented in Westchester County's Plan CORRECTIVE ACTION DEMONSTRATED: Procedure 5, Department of Transportation, revised 08/06/1 0, now references a Dosimeter of Legal Record (DLR), which is the appropriate term for the new permanent record dosimetry.

ISSUE NO: 32-08-3.a.l-P-18 ISSUE: Hendrick Hudson Bus Company did not have proper dosimeters as described in the "Westchester County Radiological Emergency Plan for the Indian Point Energy Center". The bus company had 50 Arrow-Tech, Model 730 direct reading dosimeters with a range ofO-20R. Procedures 3 and 5 of the Westchester County Radiological Emergency Plan call for a 0-5R dosimeter and a 0-200R dosimeter to be issued.

CORRECTIVE ACTION DEMONSTRATED: Procedure 5, Department of Transportation,, revised 08/06/1 0, now gives the option of providing Bus Drivers either 0-5R and 0-200R Direct Reading Dosimeters (DRSs) or a single 0-20R DRD. However, Procedure 3.3 has been similarly revised and now also gives the option of using a single 0-20R DRD.

102