|
---|
Category:Legal-Exhibit
MONTHYEARML15337A3522015-11-17017 November 2015 Official Exhibit - NYS000582-00-BD01 - Diagram of Strength Vs Amplitude by Dr. Richard T. Lahey ML15337A3372015-11-11011 November 2015 Official Exhibit - ENTR00726-00-BD01 - Track 2 Hearing Exhibit List ML15337A3322015-11-0505 November 2015 Official Exhibit - ENT000726-00-BD01 - Entergy Track 2 Hearing Exhibit List ML15337A3352015-11-0505 November 2015 Official Exhibit - RIVR14001-00-BD01 - Riverkeeper Tailored Track 2 Exhibit List ML15337A3362015-11-0505 November 2015 Official Exhibit - NRCR10001-00-BD01 - NRC Staff Track 2 Exhibit List ML15337A3332015-11-0404 November 2015 Official Exhibit - NYSR25001-00-BD01 - NYS Revised Tailored Exhibits List Relevant to Track 2 Contentions ML15337A3312015-11-0303 November 2015 Official Exhibit - NRC000230-00-BD01 - Corrections to Prefiled Testimony NRC000168 and NRC000197 ML15337A3262015-10-29029 October 2015 Official Exhibit - ENT000722-00-BD01 - Supplemental Testimony of Entergy Witnesses Nelson Azevedo, Timothy Griesbach & Randy Lott ML15337A3292015-10-29029 October 2015 Official Exhibit - ENTR16001-00-BD01 - Entergy Revised Exhibit List ML15337A3242015-09-23023 September 2015 Official Exhibit - NYS000576-00-BD01 - Pre-Filed Supplemental Testimony of Richard T. Lahey Re Contentions NYS-25, NYS-26B/RK-TC-1B & NYS-38/RK-TC-5 ML15337A3072015-09-0909 September 2015 Official Exhibit - NYS000573-PUB-00-BD01 - Supplemental Reply Statement of Position of the State of New York and Riverkeeper, Inc. in Support of Contention NYS-38/RK-TC-5 (Public, Redacted) (September 9, 2015) ML15337A2962015-09-0909 September 2015 Official Exhibit - NYS000570-PUB-00-BD01 - Supplemental Reply Statement of Position of the State of New York and Riverkeeper, Inc. in Support of Contention NYS-26B/RK-TC-1B (Public, Redacted) (September 9, 2015) ML15337A2832015-09-0909 September 2015 Official Exhibit - NYS000563-00-BD01 - Pressurized Water Reactor (PWR) Systems, USNRC Technical Training Center, Reactor Concepts Manual, Pages 4-1 to 4-28 ML15337A2952015-09-0909 September 2015 Official Exhibit - NYS000569-PUB-00-BD01 - Pre-filed Supplemental Reply Testimony of Richard T. Lahey, Jr. in Support of Contention NYS-26B/RK-TC-1B (Public, Redacted) (September 9, 2015) ML15337A2942015-09-0909 September 2015 Official Exhibit - NYS000568-PUB-00-BD01 - Supplemental Reply Statement of Position of the State of New York in Support of Contention NYS-25 (Public, Redacted) (September 9, 2015) ML15337A2932015-09-0909 September 2015 Official Exhibit - NYS000567-PUB-00-BD01 - Pre-filed Supplemental Reply Testimony of Richard T. Lahey, Jr. in Support of Contention NYS-25 (Public, Redacted) (September 9, 2015) ML15337A3042015-09-0909 September 2015 Official Exhibit - NYS000571-PUB-00-BD01 - Pre-filed Supplemental Reply Testimony of David J. Duquette in Support of Contention NYS-38/RK-TC-5 (Public, Redacted) (September 9, 2015) ML15337A2972015-09-0909 September 2015 Official Exhibit - RIV000164-00-BD01 - NUREG-1740, ACRS, Voltage-Based Alternative Repair Criteria: a Report to the Advisory Committee on Reactor Safeguards by the Ad Hoc Subcommittee on a Differing Professional Opinion (2001) ML15337A3062015-09-0909 September 2015 Official Exhibit - NYS000572-PUB-00-BD01 - Pre-filed Supplemental Reply Testimony of Richard T. Lahey, Jr. in Support of Contention NYS-38/RK-TC-5 (Public, Redacted) (September 9, 2015) ML15337A2822015-09-0909 September 2015 Official Exhibit - NYS000566-00-BD01 - Figure 1 for Supplemental Reply Testimony of Dr. Richard T. Lahey ML15337A3142015-09-0404 September 2015 Official Exhibit - ENTR00615-PUB-00-BD01 - Entergy'S Statement of Position Re Contention NYS-25 (Embrittlement) - Redacted ML15334A2842015-08-10010 August 2015 Official Exhibit - ENT000687-00-BD01 - NRC, Safety Evaluation Report, Topical Report on ASME Section III Piping and Component Fatigue Analysis Utilizing the Westems Computer Code (WCAP-17577, Revision 2) (Undated) ML15335A2932015-08-10010 August 2015 Official Exhibit - NRCR00104-00-BD01 - on Yee Statement of Professional Qualifications (Revised) ML15337A2642015-08-10010 August 2015 Official Exhibit - NRC000196-PUB-00-BD01 - NRC Staff'S Initial Statement of Position on Contention NYS-25 (Reactor Vessel Internals) ML15337A3192015-08-10010 August 2015 Official Exhibit - ENT000698-PUB-00-BD01 - Entergy'S Revised Statement of Position Regarding Contention NYS-38/RK-TC-5(Safety Commitments) (Aug. 10, 2015)Redacted ML15337A3202015-08-10010 August 2015 Official Exhibit - ENT000699-PUB-00-BD01 - Redacted Revised Testimony of Entergy Witnesses Nelson Azevedo, Robert Dolansky, Alan Cox, Jack Strosnider, Timothy Griesbach, Barry Gordon, Randy Lott, and Mark Gray Regarding Contention NYS-38/RK ML15337A3172015-08-10010 August 2015 Official Exhibit - ENT000678-PUB-00-BD01 - NL-07-140, Letter from F. Dacimo, Entergy, to NRC Document Control Desk, ?Reply to Request for Additional Information Regarding License Renewal Application? (Nov. 28, 2007)Redacted ML15337A2652015-08-10010 August 2015 Official Exhibit - NRC000197-PUB-00-BD01 - NRC Staff Testimony of Dr. Allen Hiser, Jeffrey Poehler, and Gary Stevens on NYS-25 and NYS-38/RK-TC-5 ML15337A2412015-08-10010 August 2015 Official Exhibit - NRCR00147-00-BD01 - NRC Staff'S Revised Statement of Position on State of New York and Riverkeeper'S Joint Contention NYS-38/RK-TC5 (Revised) ML15335A2902015-08-10010 August 2015 Official Exhibit - NRC000222-00-BD01 - IP3 FSAR Rev. 04 Chapter 3 (2011) (Excerpt) ML15334A2632015-08-10010 August 2015 Official Exhibit - ENT000648-00-BD01 - M. Mitchell, Chief, Vessels and Internals Integrity Branch, Response to Non-Concurrence Regarding Safety Evaluation for Topical Report MRP-227 Pressurized Water Reactor Internals Inspection and Evaluat ML15337A2622015-08-10010 August 2015 Official Exhibit - NRC000228-00-BD01 - Indian Point Unit 2 Technical Specifications 3.1.4 ML15337A2452015-08-10010 August 2015 Official Exhibit - NRC000227-00-BD01 - Gary Stevens Statement of Professional Qualifications ML15337A2632015-08-10010 August 2015 Official Exhibit - NRC000229-00-BD01 - Indian Point, Unit 3 Technical Specifications 3.1.4 ML15335A2192015-08-10010 August 2015 Official Exhibit - ENTR00031-00-BD01 - Curriculum Vitae of Alan B. Cox ML15335A2112015-08-10010 August 2015 Official Exhibit - ENTR20186-00-BD01 - Curriculum Vitae of Mark A. Gray ML15337A3162015-08-10010 August 2015 Official Exhibit - ENT000616-PUB-00-BD01 - Testimony of Entergy Witnesses Nelson F. Azevedo, Robert J. Dolansky, Alan B. Cox, Jack R. Strosnider, Timothy J. Griesbach, Randy G. Lott, and Mark A. Gray Regarding Contention NYS-25 (Embrittleme ML15337A2782015-08-10010 August 2015 Official Exhibit - NRC000168-PUB-00-BD01 - NRC Staff Testimony of Dr. Allen Hiser, Dr. Ching Ng, Mr. Gary Stevens, P.E., and Mr. on Yee, Concerning Contentions NYS-26B/RK-TC-1B and NYS-38/RK-TC-5 ML15337A2712015-08-10010 August 2015 Official Exhibit - NRC000223-00-BD01 - IP3 FSAR Rev. 04 Chapter 14 (2011) ML15337A2592015-08-10010 August 2015 Official Exhibit - NRC000224-00-BD01 - IP3 FSAR Rev. 04 Chapter 16 ML15337A2442015-08-10010 August 2015 Official Exhibit - NRCR00161-00-BD01 - NRC Staff Testimony of Dr. Allen L. Hiser and Mr. Kenneth J. Karwoski Concerning Portions of State of New York and Riverkeeper, Inc. Joint Contention NYS-38/RK-TC5 (Revised) ML15334A2822015-08-10010 August 2015 Official Exhibit - ENT000680-00-BD01 - Curriculum Vitae of Barry M. Gordon ML15335A2912015-08-10010 August 2015 Official Exhibit - NRCR00118-00-BD01 - Indian Point Unit 3 Technical Specifications (Excerpt) (Revised) ML15334A2282015-08-10010 August 2015 Official Exhibit - ENT000634-00-BD01 - Entergy, IP2, FSAR Update, Revision 25 (2014) (Excerpts) ML15335A2822015-08-10010 August 2015 Official Exhibit - NRC000220-00-BD01 - Pressurized Water Reactor Owners Group (PWROG) Presentation Slides, Industry and NRC Coordination Meeting Materials Programs Technical Exchange: Clevis Insert Bolt Update, (June 2014) ML15337A2692015-08-10010 August 2015 Official Exhibit - NRC000169-00-BD01 - NRC000169 - Indian Point, Unit 2 Technical Specifications (Excerpt) ML15337A2602015-08-10010 August 2015 Official Exhibit - NRC000226-00-BD01 - Jeffrey C. Poehler Statement of Professional Qualifications ML15335A2732015-08-10010 August 2015 Official Exhibit - NRC000183-00-BD01 - NRC Inspection Manual, Inspection Procedure 71013, Site Inspection for Plants with a Timely Renewal Application (Sept. 25, 2013) ML15335A2202015-08-10010 August 2015 Official Exhibit - ENTR00184-00-BD01 - Curriculum Vitae of Jack R. Strosnider ML15335A3012015-08-10010 August 2015 Official Exhibit - NRC000206-00-BD01 - Indian Point, Unit 2, Updated Final Safety Analysis Report (Ufsar), Rev. 25, Chapter 14 - Safety Analysis (2014) 2015-09-09
[Table view] |
Text
United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.
In the Matter of:
(Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #: ENT000037-00-BD01 Identified: 10/15/2012 Admitted: 10/15/2012 Withdrawn:
Rejected: Stricken:
Other:
ENT000037 Submitted: March 28, 2012 Technologies, Inc.
Resume: Robert M. Aleksick Professional Highlights 3/4 President of CSI Technologies, a technology firm that provides software and consulting to the nuclear electric power generation industry worldwide 3/4 Published, nationally recognized expert in Flow-Accelerated Corrosion (FAC) 3/4 Over twenty years of engineering and project management experience in the nuclear industry, specializing in Flow-Accelerated Corrosion (FAC) and Buried/Underground Piping issues 3/4 Managed or worked on nearly 1,000 FAC and other projects since 1989 3/4 Invited by EPRI to sit on various software design/review committees, including multi-million dollar development projects for CHECWORKS/SFA and BPWORKS Experience Mr. Aleksick has overall responsibility for creating and delivering value to our clients, including strategic aspects of marketing, finance, sales, operations, and new product develoment. He is a published, nationally recognized expert in the FAC services field with over twenty years of experience.
His technical background is in mechanical systems engineering, specializing in the development, implementation, and management of Engineering Programs, with special expertise in flow-accelerated corrosion (FAC), buried piping, and service water/raw water corrosion programs. His technical experience includes the following:
x Legal/Regulatory Expert Support for Restart, Power Uprate, and License Extension Efforts Mr. Aleksick has provided expert support to clients before, during, and after various NRC inspections, audits, and licensing proceedings. For example, Mr. Aleksick played a key role interfacing with NRC in support of Fort Calhouns restart efforts following their 1997 FAC rupture.
In addition, he has supported numerous Extended Power Uprate license amendments (see tinyurl.com/3bq7xj4 for a transcript of his testimony in support of the Waterford EPU). In addition, he has provided support to clients in advance of and during audits and assessments by other bodies, including INPO, WANO, and others. Mr. Aleksick also provided expert support to Kansas City Power & Light for the develoment of legal strategies following the fatalities caused by the FAC piping rupture at Iatan Station in 2007.
x FAC Project Management and Performance Mr. Aleksick has managed or worked on nearly 1,000 FAC projects since 1989 and is intimately familiar with every element of such programs, including:
Development, review, and calibration of FAC-predictive risk-ranking codes, including CHEC, CHECUP, CHECMATE, CHECWORKS/SFA, and others Development and review of technical and administrative procedures Preparation and review of essential FAC program documents including system susceptibility/program basis documents and susceptible non-modeled ranking analyses Preparation of program health reports/matrices Preparation of detailed program assessements/audits Page 1 of 3
Technologies, Inc.
x Notable Projects Mr. Aleksick has had involvement in a number of high-profile FAC projects, including:
Served (on a contract basis) as the Corporate FAC Program Manager at Exelon, responsible for day-to-day management and long-term planning for their entire fleet of nuclear stations Developed and provided FAC/Buried Pipe training to utility executive and technical personnel, EPRI management and technical personnel, INPO field auditors, and NRC personnel Developed and provided FAC training to engineers in China on the application of CHEWORKS/SFA to the generation of reactors currently under construction there Due to his familiarity with the industry direction, practices, needs, and personnel, Mr. Aleksick is frequently consulted about staffing decision by utilities Mr. Aleksick has assisted numerous utilities with restart/recovery plans following FAC ruptures or other significant events x Field Experience Mr. Aleksick's FAC experience on site includes over twenty outages at fifteen different sites. This hands-on site work consisted of coordinating NDE and craft contractors and calculations of component remaining life based on data obtained from the examinations.
Mr. Aleksick also has extensive experience in the development and implementation of programs to address raw water/service water corrosion, valve body erosion, and drywell corrosion.
Prior to founding CSI Technologies, Inc., Mr. Aleksick was a Senior Engineer and key team member at Vectra Technologies (formerly ABB Impell) where he served as the lead Project Engineer.
Education x Undergraduate: University of Illinois at Urbana-Champaign, five years of B.S.-level studies in Nuclear Engineering.
x Undergraduate: University of Nottingham (England), School of Humanities, one year of undergraduate study of Philosophy.
x Graduate: Northwestern University, Evanston, IL, Kellogg Graduate School of Management, Kellogg Management Institute: Essentials of the Masters in Business Administration, one-year non-degree certificate program.
Coursework Mr. Aleksick's coursework at the University of Illinois included: Design in Nuclear Engineering, Safety Analysis of Nuclear Reactor Systems, Nuclear Waste Management, Materials in Nuclear Engineering, Nuclear Physics, Nuclear Reactor Physics, and Radiation Protection.
Mr. Aleksicks coursework at the Kellogg School of Management included: Negotiation, Leadership and Strategic Change, Accounting, Evaluating Financial Results, Functional Integration, Finance, Marketing, Strategy Implementation, Operations, Managerial Decision-Making, and Information Technology.
Affiliations Member, American Nuclear Society Member, American Society of Mechanical Engineers Sustaining Member, NACE International INPO Flow-Accelerated Corrosion Programs Instructor Page 2 of 3
Technologies, Inc.
Selected Publications Aleksick, R. M., and Rhoades, K. E., An Integrated Approach to Erosion/Corrosion Monitoring Programs, ANS/ASME Nuclear Energy Conference Proceedings, August 1992.
Aleksick, R. M., Pulido, J. E., et al, An Alternate Approach to Calibrating FAC-Predictive Models Using Inspection Data, 4th International Topical Meeting on Nuclear Thermal Hydraulics, Operations and Safety, April 1994.
Aleksick, R. M., Iverson, J. A, Ratway, J. R., and Penny, R., Flow-Accelerated Corrosion of Susceptible Non-Modeled Piping, Fourth International Symposium on Flow-Accelerated Corrosion, June 1995.
Technical Editor of EPRI TR-106611, Flow-Accelerated Corrosion in Power Plants, a 500+ page technical handbook on FAC, 1998 and 2003 editions.
Technical Reviewer of EPRI Final Report 1009599, September 2004, Guidelines for Plant Modeling and Interpretation of Inspection Data (technical reviewer).
Significant Contributor to EPRI 1010059, Service Water Piping Guidline, Final Report, 2005.
Significant Contributor to EPRI NSAC-202L, Recommendations for an Effective Flow-Accelerated Corrosion Program, multiple editions from 1994 to 2006.
Page 3 of 3