ML12335A414
ML12335A414 | |
Person / Time | |
---|---|
Site: | Indian Point ![]() |
Issue date: | 08/31/2008 |
From: | Armbruster J, Kim W, Seeber L, Sykes L Columbia Univ |
To: | Atomic Safety and Licensing Board Panel |
SECY RAS | |
References | |
RAS 21601, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 | |
Download: ML12335A414 (24) | |
Text
United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.
RIV000031 In the Matter of: Submitted: December 22, 2011 (Indian Point Nuclear Generating Units 2 and 3)
ASLBP #: 07-858-03-LR-BD01 Docket #: 05000247 l 05000286 Exhibit #: RIV000031-00-BD01 Identified: 10/15/2012 Admitted: 10/15/2012 Withdrawn:
Rejected: Stricken:
Other:
Bulletin of the Seismological Society of America, Vol. 98, No. 4, pp. 1696-1719, August 2008, doi: 10.1785/0120070167 Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes in the Greater New York City-Philadelphia Area by Lynn R. Sykes, John G. Armbruster, Won-Young Kim, and Leonardo Seeber Abstract A catalog of 383 earthquakes in southeastern New York, southwestern Connecticut, northern New Jersey, and eastern Pennsylvania, including metropolitan New York City and Philadelphia, is compiled from historical and instrumental data from 1677 through 2006. A magnitude-felt area relationship is used to calculate the equivalent magnitude mb Lg prior to the advent of abundant instrumental data in 1974.
Revised locations are computed for a number of historic earthquakes. Most hypo-centers are concentrated in older terranes bordering the Mesozoic Newark basin in the Reading, Manhattan, and Trenton prongs and in similar rocks found at a shallow depth beneath the coastal plain from south of New York City across central New Jersey. Historic shocks of mb Lg 3 and larger were most numerous in the latter zone.
The largest known event, mb Lg 5.25, occurred just offshore of New York City in 1884.
Many earthquakes have occurred beneath the 12-km wide Ramapo seismic zone (RSZ) in the eastern part of the Reading prong, where station coverage was the most ex-tensive since 1974. The southeastern boundary of the RSZ, which is nearly vertical, extends from near the surface trace of the Mesozoic Ramapo fault to depths of 12-15 km. Because the Mesozoic border fault dips about 50°-60° southeast, earth-quakes of the RSZ are occurring within middle Proterozoic through early Paleozoic rocks. Which faults within the RSZ are active is unclear. Well-located activity in the Manhattan prong since 1974 extends to similar depths but cuts off abruptly at all depths along a northwest-striking boundary extending from Peekskill, New York, to Stamford, Connecticut. That boundary, which is subparallel to brittle faults farther south, is inferred to be a similar fault or fault zone. Those brittle features may have formed between the Newark, Hartford, and New York bight basins to accommodate Mesozoic extension. The Great Valley in the northwestern part of the study region is nearly devoid of known earthquakes. While few focal mechanism solutions and in situ stress measurements of high quality are available, the maximum compressive stress is nearly horizontal and is oriented about N64°E, similar to that in adjacent areas. The catalog is likely complete for events of mb Lg > 5 since 1737, 3:5 since 1840, and 3:0 since 1928. Extrapolation of the frequency-magnitude relationship indicates that an event of mb Lg 6:0 is expected about once per 670 yr.
Online Material: Observations and tectonic setting of historic and instrumentally located earthquakes in the greater New York City-Philadelphia area.
Introduction The purpose of this article is twofold: to present a for various magnitudes. We end with a brief discussion of catalog of all known earthquakes in the greater New York earthquake hazards and risks.
City-Philadelphia area from 1677 through 2006 and then Better understanding of seismic hazard and risk in the to describe those events in a context that includes geologic region, especially better knowledge and calibration of the terranes, faults, and contemporary state of stress in this preinstrumental and limited instrumental records prior to highly populated intraplate region. We describe the sizes of the advent of a more extensive network in 1974, is very im-all events in terms of a common magnitude scale, mb Lg, and portant. The 2° by 2° area examined (Figs. 1-3) has a rela-discuss the completeness of the catalog as a function of time tively low earthquake hazard but high vulnerability and, 1696
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1697 42 K
N M > 5.0 Hudson 4.0 < M < 5.0 New York State River 3.5 < M < 4.0 P 3.0 < M < 3.5 1881 P axis Wf Borehole Breakout N Hydrofracture ig y h 0 KM 50 a lle H V ud H
a t re 1951 1845 G ng CT PA NJ PS 1848 G
ong l t Pro CL 41 Pr fau o
n g 1783 ap n. 1985 i am e ad R Ma R 1737 NYC Long Is.
1957 sin CL 2003 FF HF a SI 1937 B
r k 1895 wa 1884 BV Ne 1927 B
1979 1884 NB T n 1980 l ai 1938 P F t al HV PHIL s 1938 Coa 1938 40 75 74 W Figure 1. Known earthquakes of M 3:0 in the greater New York City-Philadelphia area from 1677 through 2006. Magnitude, mbest , is mb Lg or its equivalent, as explained in text. Epicenters of large events of 1737 and 1783 maybe uncertain by 100 km and are shown as open circles. No events occurred behind the legend inset. Pink denotes Pre-Cambrian rocks; yellow denotes Mesozoic rocks of the Newark basin.
Place names: Kingston, New York, K; New York City, NYC; Philadelphia, PHIL; Newburgh, New York, N; Poughkeepsie, New York, P; Staten Island, New York, SI; Trenton, New Jersey, T; and Wappinger Falls, New York, Wf. Geological features: Buckingham Valley, BV; Camerons Line, CL; Flemington-Furlong fault, FF; Green Pond syncline, GPS; Hopewell fault, HF; Hudson Highlands, Hud High.;
Huntingdon Valley fault, HVF; Manhattan prong, Man. Prong; and New York bight basin, NBB. Major faults and geology are from Prucha et al. (1968), Fisher et al. (1970), Ratcliffe (1971, 1976), Isachsen and McKendree (1977), Ratcliffe (1980), Hall (1981), Hutchinson et al.
(1986), Ratcliffe et al. (1986), Lyttle and Epstein (1987), Seeber and Dawers (1989), Ratcliffe (1992), Drake et al. (1996), and Olsen et al.
(1996). Horizontal projections of the P axes of better-determined focal mechanisms of earthquakes and directions of maximum horizontal compressive stress from two sets of hydrofracture (Zoback et al., 1985; Rundle et al., 1987) and one set of borehole breakout experiments are indicated by inward-pointing arrows (stress data in Table 4 in the electronic edition of BSSA).
1698 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber 42 K
N M > 5.0 4.0 < M < 5.0 New York State 3.5 < M < 4.0 3.0 < M < 3.5 1881 Wf 2.24 < M < 3.0 X M < 2.25 N 0 KM 50 Pe NJ PA CT 1783 St 41 1737 NYC 1937 1895 1884 PHIL 40 75 74 W Figure 2. Entire catalog of known earthquakes in greater New York City-Philadelphia area from 1677 through 2004. No events occurred behind the legend inset. Rock units, faults, magnitudes, open circles, and place names are the same as in Figure 1. Peekskill, New York, Pe; Stamford, Connecticut, St.
hence, high seismic risk (Tantala et al. 2003). New York number of major construction projects including a replace-City, Newark, Trenton, and Philadelphia as well as their ment for the aging Tappan Zee Bridge, which carries the highly populated surrounding areas are located in the study New York State Thruway over the Hudson River, and to area. The population of the area was 21.4 million in 2005 the proposed extensions of the operating licenses for two nu-(G. Yetman, personal comm., 2007, based on U.S. census clear power plants at Indian Point. Filled land poses greater data). Better knowledge of seismic hazard is relevant to a earthquake hazards for large portions of several cities while
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1699 Figure 3. Instrumental locations of earthquakes from 1974.0 to 2007.0. Arrows denote approximate southeastern boundary of the RSZ and nortwest-striking seismic boundary BB between Stamford, Connecticut, and Peekskill, New York. Purple numerals denote the distance along the Ramapo zone.
other parts of the study area consist of hard rock at or close to Coverage by a more extensive network extends from 1974 to the surface (Tantala et al., 2003). the present. Limited instrumental data extend back to the The Lamont-Doherty Earth Observatory in conjunction 1930s. While the largest earthquakes since the 1930s were with several local institutions has operated a network of three of about M 4, the historic record is much longer and includes or more seismograph stations in the greater New York City three events larger than M 5. Historic activity of M > 5 has area since 1962 (Isacks and Oliver, 1964; Page et al., 1968). been higher in southeastern New York and northern New
1700 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber Jersey than in many other areas of the central and eastern other pertinent data, the values of mb Lg and felt area used for United States. It stands out as a bulls-eye on seismic hazard magnitude calibration, and stress determinations.
maps (e.g., Frankel et al., 2005). While those hazard maps indicate higher values near Charleston, South Carolina, New Data Sources Madrid, Missouri, and northern New York State and compar-able values in southern New Hampshire, those four areas Sykes (1986) compiled a catalog of hypocenters, origin have much smaller populations and assets at risk than the times, magnitudes, and felt information for known earth-study region. quakes in the study area through 1983 from the literature Which faults are active in this intraplate region has been and instrumental data from the network of stations operated a subject of ongoing debate. Several faults displace Mesozoic by Lamont-Doherty. Only an abstract of that work was pub-sedimentary and igneous rocks, but evidence of faulting in lished. Seeber and Armbruster (1991) published a catalog of younger sediments of the coastal plain and in postglacial central and eastern U.S. earthquakes of M 3 using im-sediments is either missing or debatable. We find that proved intensity data. The present catalog updates those earthquakes originate from many faults rather than a few sin- studies through 2006 using instrumental data from the gle major faults. Nevertheless, seismicity is not pervasive Lamont Cooperative Seismic Network (e.g., Schnerk et al.,
through our study area but is concentrated in prominent 1976; Seeber and Armbruster, 1986, 1991; Seeber et al.,
zones, such as the Ramapo seismic zone (RSZ in Fig. 3) 1993). It includes many earthquakes of M < 3. Locations and the Manhattan prong (Fig. 1). The southeastern side of and other parameters were obtained from detailed studies the RSZ forms an abrupt boundary that extends to depths of of several individual earthquakes and their aftershocks by 12-15 km. While that boundary intersects the surface trace Sbar et al. (1970), Pomeroy et al. (1976), Sykes (1976),
of the Mesozoic Ramapo fault, its dip is generally steeper, Yang and Aggarwal (1981), Seborowski et al. (1982), Dewey placing it within older footwall rocks. The strikes and dips and Gordon (1984), J. W. Dewey and D. W. Gordon (per-of contemporary individual faults within the RSZ are uncer- sonal comm., 1984), Kafka et al. (1985), Quittmeyer et al.
tain. Seismic activity within the Manhattan prong also ex- (1985), Thurber and Caruso (1985), Seeber and Dawers tends from near the surface to depths of about 12-15 km. (1989), Kim (1998), and Seeber (2004).
A surprising new result based on 34 yr of instrumental data Information on pre-1974 earthquakes, especially felt re-is that activity in the Manhattan prong cuts off abruptly along ports, were obtained from Rockwood (1872-1886), Smith a nearly vertical, northwest-striking boundary that extends (1962, 1966), the yearly series United States Earthquakes from Stamford, Connecticut, to Peekskill, New York. This from 1928 to 1986 of the U.S. Department of Commerce boundary is subparallel to the youngest brittle faults in the (1968) and U.S. Geological Survey, Sykes (1976), Winkler Manhattan prong, some of which are seismogenic. The east- (1979), Nottis (1983), Nottis and Mitronovas (1983), Seeber ern Hudson Highlands to the northeast, also an area of older and Armbruster (1986, 1988, 1991), Stover and Coffman strong rocks, is nearly aseismic. (1993), and Wheeler et al. (2005). We collected additional Those who are mainly interested in the geologic and intensity information for several events from newspapers, tectonic setting of earthquakes and/or hazards and risk may which we used in revising their epicentral locations.
skip the next sections on compilation of the catalog, its com- Revised locations for nearly all events from 1951 to pleteness, magnitude determination, and rates of earthquake 1974 of mb Lg > 2:5 are based on a combination of felt re-occurrence. ports and at least some instrumental data as are those for three earthquakes in central New Jersey of mb Lg 3.8-3.9 in 1938 (Street and Turcotte, 1977; Dewey and Gordon, 1984; Compilation of the New Catalog J. W. Dewey and D. W. Gordon, personal comm., 1984). Lo-cations and origin times for nearly all events since 1974 are One aim in this article is to provide a common measure based on instrumental data from local and regional stations of earthquake size over the 330 yr for which a variety of pa- as reported in the series Regional Seismicity Bulletin of the rameters were reported or measured, such as the size of the Lamont-Doherty Network (e.g., Schnerk et al., 1976), final felt area, maximum intensity, and several different seismic reports on the Lamont network (e.g., Seeber et al., 1993), and magnitudes. These parameters were then normalized in terms the series Northeastern U.S. Seismic Network (e.g., Chiburis of the magnitude scale mb Lg as determined from Lg surface and Ahner, 1976). Arrival times were reread in revising the waves for frequencies near 1 Hz as described by Nuttli locations and mb Lg for nine earthquakes between 1951 and (1973). Lg waves are typically the largest seismic waves re- 1976 (asterisks in Table 1 in the electronic edition of corded at regional distances from earthquakes in the eastern BSSA). Other arrival times were not reread.
and central United States and adjacent parts of Canada. Quarry and other industrial explosions were eliminated Much better data on Lg are available for calibration in those by record analysts as much as possible and are not included regions compared to Mw , the magnitude derived from seis- in the new catalog. Pomeroy et al. (1976) identified a series mic moment. Tables 1-4 in the electronic edition of BSSA of very shallow earthquakes at Wappinger Falls, New York contain the catalog, which lists various measures of size and (Fig. 1), that were triggered by the removal of a vertical load
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1701 at a large quarry. They are included in the catalog and figures. mb Lg ML 0:15 for 2 ML 6:5 in eastern North Seeber et al. (1998) identified a similar sequence in Pennsyl- America. Figure 5 shows that his relationship also holds with vania to the west of the study area in 1994. While those little scatter for earthquakes of 2 < mb Lg < 4:2 in the study events were identified as earthquakes, small triggered shocks area (red circles) and for larger events reported by him in at or near some other quarries may well have been missed adjacent areas. ML 0:15 and mb Lg were used in determin-by record analysts. Table 2 in the electronic edition of ing a single best estimate of equivalent Lg magnitude, which BSSA describes 15 events that were identified as either we call mbest . This expands the list of reliable measures of having nonearthquake sources (e.g., Nottis, 1983) or result- mb Lg because only ML was determined for nine of the events ing from erroneous listings and duplications in previous in Table 1 in the electronic edition of BSSA. Either mb Lg catalogs. or ML or both were determined for all but one event (an after-shock) of mbest > 3:0 in the catalog since 1937. We give Magnitude Determination either measure the highest weight in estimating mbest . We note that estimates of ML made by Smith (1966) for eastern The felt area offers a measure of size for earthquakes North America generally are too large because he used at-without either any or good instrumental recordings. Earth- tenuation values appropriate to southern California.
quakes with both felt areas and good instrumental data Intensities and other magnitudes were reported for many (18 in Table 3 in the electronic edition of BSSA) were of the earthquakes in the study area. The four subparts of used for calibration of those earthquakes. Measurements of Figure 6 compare magnitudes determined from Lg waves mb Lg at stations in eastern North America were made for (mb Lg), ML , felt area (mf ), coda duration (Mc ), higher-events in the study area from 1951 to 1984 at frequencies frequency Lg (Mn ), and maximum reported intensity on near 1 Hz following the methodology of Nuttli (1973). We the Modified Mercalli (MM) scale. Unless stated otherwise, used analog records from the World-Wide Standardized mb Lg was measured in a narrow frequency band near 1 Hz.
Seismograph Network and similar instruments with peak Because mf was determined from the log of the felt area magnification near 1 Hz, which, unlike many shorter-period using the relationship in Figure 4, it is understandable that recordings that became available in the 1970s, did not need it is nearly equivalent to mb Lg between mf 2.2 and 4 to be filtered to measure 1 Hz Lg. We also determined felt (Fig. 6a). Hence, mf offers a measure of size for preinstru-areas for as many of these events as possible. Felt area-mb Lg mental events that is reasonably consistent with mb Lg.
values for those earthquakes along with those for the se-A magnitude scale Mc based on signal (coda) duration quence in central New Jersey in 1938 (Street and Turcotte, of higher-frequency seismic waves was developed for New 1977) and the 1985 Ardsley, New York, shock of mb Lg 4.2 England by Chaplin et al. (1980). An advantage of Mc is that (Kim, 1998) are shown as red circles in Figure 4. While some it often can be determined for very small events. Most re-events as small as mb Lg 2 are felt, felt area decreases rapidly ported magnitudes for the Lamont-Doherty network since for mb Lg < 2:5. Also, Lg near 1 Hz often was difficult to measure even at one to a few stations for mb Lg < 2:5. 1982 are Mc as are some values as early as 1973. They were Because several historic events in our study area were calculated using the parameters of Chaplin et al. (1980).
larger than the largest instrumental event (mb Lg 4.2), it was Figure 6b indicates considerable scatter in mb Lg, mb , and necessary to extend the calibration using measurements from ML as a function of Mc , especially for Mc 3. Using data other areas with similar attenuation characteristics. Lg prop- from 1974 to 1983 Kafka et al. (1985) found that Mc over-agates efficiently in eastern North America, including the estimates mb Lg (1 Hz) by about 0.1-0.2 units. In determin-study area, but not so in tectonically active regions of western ing mbest we take Mc mb Lg but give it less weight than North America. The other values of mb Lg in Figure 4 are either mb Lg, ML , or mf .
from Nuttli and Zollweg (1974), Sbar et al. (1975), Street Figure 6c indicates that Mn , a measure of mb Lg at (1976), Street and Turcotte (1977), Bollinger (1979), Street higher frequency, also scatters considerably with respect and Lacroix (1979), Kim (1998), and Seeber et al. (1998). to either mf , ML , or mb Lg (1 Hz.). Hence, we give small The felt areas of those events are either from them, yearly weight to Mn in calculating mbest . It is much larger than those issues of United States Earthquakes, or the Community In- three magnitudes for Mn > 3. The two largest values of Mn ternet Intensity Working Group (2006). Because a linear (Fig. 6c) were from a sequence at Abington, Pennsylvania, relationship does not fit the entire data set in Figure 4, a near Philadelphia in 1980 (Bischke et al., 1980). For those series of solid lines were fit by eye. They were then used to two we took mbest mf and then used the relative values of derive an equivalent Lg magnitude (mf ) from felt area. In cal- Mn to obtain mbest for four other events in that sequence. Six culating mf , however, we did not take into account popula- remaining events from 1973 to 1981 that did not have other tion density, time of day, hypocentral depth, or site response. measures of magnitude were not larger than Mn 2.2-2.8; 27 The regional magnitude scale ML , which was originally others were smaller. Only one of those was felt and it only at developed for southern California, was modified by Ebel a single location. For those 33 events we took mbest Mn .
(1982) and Kim (1998) to account for much smaller seis- Inclusion of two values of Mn 2.8 and four of Mn 2.4-2.6 mic attenuation in eastern North America. Kim (1998) finds may contribute to the somewhat larger rates of small events
1702 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber 7
greater NYC area NEUS+Canada Central US 6 SE US DEL + PA 5
log(felt area--km2) 4 3
2 2 3 4 5 6 7 mbLg(~1 Hz)
Figure 4. Log of felt area as a function of mb Lg as determined for frequencies near 1 Hz using methodology of Nuttli (1973). Black solid line is fit by eye to data. Two red arrows indicate mb Lg may be minimum values. Events and sources of data from Table 3 in the electronic edition of BSSA.
between those dates in the next section on the completeness seismal areas is another likely factor. MM is used to deter-of the seismic record. mine mbest only when other measures were not available.
In contrast to mf , maximum intensity, MM, scatters Most of these events were reported from only one location greatly as a function of either mb Lg or ML and is clearly a and all of them have MM IV. Many of these events were poor measure of earthquake size (Fig. 6d versus 6a). This probably too small to be reported from multiple localities, difference is in part a depth effect. The depth of the source but they were likely shallow and hence felt only at very short has little effect on felt area but has a major effect on MM, distances. Their size, therefore, will be overestimated if de-particularly for small earthquakes that radiate rapidly attenu- rived from an MM-magnitude scale developed for a represen-ating high-frequency waves. Inconsistent sampling of mezo- tative range of depths. In our region magnitudes estimated
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1703 7 that size is likely not complete prior to about 1840. A slope greater NYC area of minus one indicates a record that is totally incomplete be-NEUS+Canada fore a certain date. The lines on each subfigure were drawn 6 Central US by eye, emphasizing larger values of N and, of course, de-DEL + PA emphasizing counts of one to a few events.
The record for mb Lg > 3:0 is judged complete for about 5 the 78-yr interval 2005-1928, (since the start of the yearly ML + 0.15 series U.S. Earthquakes), that 4 since 1840, and that 5 for the last 270 yr, that is, since the 1737 event. The records for 4 mb Lg < 3:0 are not complete prior to about 1974, the start of the more extensive local network. From about 1975 to 1982 rates for those smaller magnitudes were about a factor of 3 1.5-2 times higher than those from 1983 to 2005. During that earlier interval funding for data analysis was at its peak as were the number of scientists, students, and record ana-lysts working on the data. More marginally recorded and felt 2 events likely were identified then. Different rates of occur-rence of small events also may be attributed in part to the 2 3 4 5 6 7 several different magnitude scales in use (Fig. 6), the transi-mbLg(~1Hz) tion from analog to digital recording, more reliance upon a triggered digital system, and a gap in the publication of felt Figure 5. ML as a function of mb Lg for events in the study area reports by the U.S. Geological Survey.
(filled circles) plus determinations from Kim (1998) for larger Figure 8 shows the cumulative number of events per shocks in adjacent areas. Measurements of ML for the study area from Ebel (1982), Ebel et al. (1986), and Kim (1998). Values year greater than a given mb Lg as a function of that magni-are listed in Tables 1 and 3 in the electronic edition of BSSA. tude. The rates used for each data point were based on the values of T in Figure 7 for which the record was judged com-plete. A negative slope, or b-value, of 0:70 0:13 was ob-from MM using formulas in the literature typically are sys- tained by the maximum-likelihood method of Aki (1965).
tematically too high. For our area we estimate the following The a-value of 1.37 in the recurrence relationship in Figure 8 values of mbest using Figure 6d: 2.7 for MM IV, 2.4 (more becomes a0 3:20 when N=T is divided by the area of populated areas) to 2.6 (less populated) for MM III, and Figure 1 in square kilometers. Extrapolating the recurrence 2.2 for MM II. A few small events that were not felt (MM I) relationship to mb Lg 6.0 and 7.0 gives repeat times of about and lack any measures of size were assigned default magni- 670 and 3400 yr but with an uncertainty that increases with tudes of 1.5-2.0. magnitude. Nearly all of the known earthquakes, however, In summary, the (best) values of magnitude, mbest , were are confined to about 60% of the area of Figures 1-3, where obtained from all available measurements of earthquake size we think future large earthquakes are most likely to occur.
weighting them progressively less in the following order:
mb Lg (from seismic waves near 1 Hz), ML , mf (from total felt area), Mc (from coda duration), Mn (from seismic waves Distribution of Earthquakes at 2-10 Hz), and MM (from maximum intensity). Figure 1 shows our study area and earthquakes in it through 2006 of mbest > 3:0. It is intended to give a perspec-Earthquake Rates and Completeness of the Catalog tive on the relative distribution of earthquakes in the entire area that is influenced the least by population density and Figure 7 shows rates of occurrence of earthquakes for distribution of seismic stations. As discussed earlier, events magnitudes greater than or equal to eight different values of of M 3 appear to be complete since 1928, those 4 appear mb Lg. Each diagram is a log-log plot where time, T, extends to be complete since 1840, and those 5 appear to be back in time before 2005 on the horizontal axis as does the complete since 1737. None of the magnitudes in Figure 1 cumulative rate of occurrence, N=T, on the vertical axis. N is are based on maximum intensity or the high-frequency mag-the cumulative number of events counted back in time from nitude Mn . Events of M 3 are typically felt over an area of 2005. T and N=T are counted back in time because records about 2500 km2 , ensuring their likely detection well before typically are more complete closer to the present. A horizon- the advent of instrumental data. Figure 2 includes all shocks tal line on each diagram of constant N=T indicates that class in the same area from 1677 through 2004 regardless of the of events is complete back to a certain date. In Figure 7a, for accuracy of their locations or completeness for various mag-example, 13 events of mb Lg 3:5 occurred in the 165-yr nitude classes. Both figures indicate Mesozoic rocks of the period 2005-1840. Going further back in time, the decrease Triassic-Jurassic Newark basin in yellow and Precambrian in cumulative values of N=T indicates the record of events of rocks of the Reading prong, Hudson Highlands, and the
1704 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber Figure 6. Relationships between various magnitudes for earthquakes in the study area. Solid lines denote equal values of quantities on two axes. (a) mf determined from felt area using the relationship in Figure 4 as a function of mb Lg. Arrows indicate mf or mb Lg values likely are minima based on poorly defined felt area or small seismic signals. (b) mf , mb Lg, and ML as a function of coda-length magnitude, Mc .
(c) mb Lg measured near 1 Hz; ML and mf as a function of Mn (mb Lg determined between about 3 and 10 Hz). (d) mb Lg, ML , and mf as a function of maximum intensity on MM scale. Intensity 1 indicates not felt.
Manhattan and Trenton prongs in pink. The first five events of newspapers and other documents (Armbruster and Seeber, in the catalog from 1677 to 1729 were felt at single localities 1986; Seeber and Armbruster, 1986, 1988). Those events and in western Connecticut. Hence, for most purposes the seis- the Westchester shocks of 1845 (mf 3.75), 1848 (mf 4.35),
mic history starts with the large shock of 1737 of mf 5:1. No and 1985 (mbest 4.07) were situated along the same belt as events are known from the period of Dutch ownership of was a sequence of three shocks beneath the coastal plain of much of the area. New Jersey in August 1938. The eastern belt also includes Earthquakes in the study area are not distributed uni- our revised location for the July 1937 earthquake of mbest 3.5, formly in space but are concentrated in zones that generally which moved it from west-central Long Island to near its follow the northeasterly trend of Appalachian orogenies and southwestern coast.
correlate with geologic provinces or terranes. The greatest Another belt of activity about 30 km wide (Figs. 2 and 3) activity in Figure 1 occurs in a belt about 35 km wide to is located to the northwest of the Newark basin and includes the east and southeast of the Newark basin. The largest his- the 1881, 1951, 1957, and 2003 shocks (Fig. 1) plus numer-toric shock, mf 5:25 in 1884, occurred along that zone. In- ous smaller earthquakes. Most of those events, especially tensity data for it and aftershocks constrain their epicenters to those located instrumentally (Fig. 3), are concentrated in the within 30 km of Lower New York Bay (Seeber and Armbrus- eastern Reading prong between the Green Pond syncline and ter, 1986). The 1884 events and the New Jersey shock of the Mesozoic Ramapo fault (Fig. 1). A special study of the 1895 of mf 4.15 were relocated using data based on searches 1895 event relocated it from the northwestern to the south-
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1705 Figure 7. Cumulative number of earthquakes of a given magnitude class per year where time, T, extends backward from 2005.0. Sub-figures (a) to (d) show results for various magnitude classes. Horizontal lines indicate rates for periods of completeness. Lines of negative slope on log-log plots indicate that class is incomplete before a certain date, that is, prior to about 1840 for M 3:5. Number beside a selected data point indicates cumulative number at various times.
eastern side of the Newark basin (Seeber and Armbruster, mined thereafter. Depths of nearly all pre-1974 events are 1988). Unfortunately, intensity data for the early historic either poorly determined or unknown.
earthquakes of mf 5.1 in 1737 and mf 5.1 and 4.65 two hours apart in November 1783 do not constrain their epicenters to better than about 50-100 km. We retain the locations for Instrumental Locations them used by Stover and Coffman (1993) (open circles in Instrumental epicenters from 1974 through 2006 (Fig. 3, Figs. 1 and 2). same area as in Figs. 1 and 2) are located more precisely While the overall distributions of earthquakes in Fig- (about 2 km) than those based solely on intensities. Fur-ures 1-3 are similar, several significant differences should thermore, instruments have detected many smaller events; be noted. Most of the smaller earthquakes in the Newark about 71% of the earthquakes in the catalog occurred since basin in Figure 2 occurred prior to 1974; many of them were 1974. Consequently, more and better data are available now felt at a single locality. The population of the basin has long than before 1974. Instrumental locations are relevant to the been much higher than that of the mountainous Reading fine structure of the seismicity, (purposely shown free of prong-Hudson Highlands. Hence, the record of activity in other data in Fig. 3), but their relative numbers within the Figure 2 for the entire period since 1677 likely overportrays study area depend in part on station distribution. For several the rate of activity in the Newark basin relative to that of decades the location capability of the local seismic network those sparsely populated regions. The distribution of events was strongest for events between about 40.4° N and 41.5° N of M > 3 (Fig. 1) is not likely to be as biased. Epicenters of in northern New Jersey and southeastern New York State.
pre-1974 shocks are not as precisely located as those deter- (The distribution of stations at various times is shown in
1706 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber by the Indian Point network from 1976 to 1983 ranged from 1 to 12 km (Seborowski et al., 1982; Thurber and Caruso, 1985).
Special studies using portable instruments permitted aftershocks of a few of the larger earthquakes in the region to be determined with a precision of 1 km or better. Pomeroy et al. (1976) report depths of only 0-1.5 km for aftershocks of the Wappinger Falls earthquake of 1974 (Fig. 2), which was triggered by the removal of a vertical load by quarrying.
Seeber (2004) computed aftershock depths of 1-2 km for an M 3.5 earthquake that occurred beneath the Delaware River in 2003 (Fig. 1). Seeber and Dawers (1989) report depths of 4.5-5.5 km for aftershocks of the 1985 Ardsley, New York, earthquake (Fig. 1). Sbar et al. (1975) calculate depths of aftershocks of 5.0-8.4 km for the 1973 Delaware-New Jersey earthquake, which occurred just off the southwestern corner of Figure 1. Hence, well-determined depths of earth-Figure 8. Cumulative frequency (log N=T) as a function of quakes in the study area range from as shallow as 1 to as deep magnitude, mb Lg. For each magnitude class, the number of events N is calculated for time interval T for which it is complete (Fig. 7). as 12-15 km. This places all of them within the upper crust.
Slope or b-value is maximum-likelihood estimate with 68% confi- Crustal thickness ranges from about 35 km beneath the dence limits. coastal plain to 45 km in the northwestern part of the study area (Costain et al., 1989).
To our knowledge all probabilistic seismic hazard cal-Schnerk et al. [1976], Kafka et al. [1985], and Seeber et al.
culations for the eastern United States assume that earth-
[1993]). Coverage south and southwest of New York City in quakes occur at a single default depth. A shock of a given Figure 3 has not been as good as that farther north. Location magnitude at a depth of only 0-2 km can generate higher capability has improved in the last decade with the installa-intensities of ground motion than one at a depth of 10 km tion of stations in New York City, Pennsylvania, and Dela-(Atkinson and Wald, 2007). Such very shallow earthquakes, ware. No stations exist, however, in the coastal plain of New which are uncommon in the western United States, occur in Jersey where the rate of activity is likely under represented in our area and surrounding regions where hard rock is found at Figure 3.
or close to the surface. They present a greater hazard than deeper shocks of the same size at epicentral distances of up Depths of Earthquakes to several kilometers.
The distribution of seismic stations for much of the study area since 1974 permitted most focal depths to be es- Tectonic Setting of Earthquakes timated with a precision of a few to 5 km. It is likely poorer in the peripheries of Figure 3, especially offshore. Hence, some The study area experienced several episodes of inter-depths are determined with higher precision than others. Fig- plate (plate boundary) tectonism during the last 1.3 billion ure 9 shows a histogram of the number of instrumentally lo-cated earthquakes as a function of depth. Ninety-five percent of those events are shallower than 12.5 km. The peaks in activity at 0, 5, and 10 km are artificial and result from those being default depths of 5-km increments for some of the calculations. Similar velocity structures of two crustal lay-ers over a mantle half-space were used in locating events since 1974.
For several years the Lamont network was augmented by a close-in array of stations surrounding the Indian Point reactors (near Pe in Fig. 2), permitting depths to be calculated with higher precision. For two events of M 1.5 and 2.1 beneath Annsville (just to the west of Pe in Fig. 2), well-determined depths of 15 km were determined independently by Lamont analysts and by Thurber and Caruso (1985). They are shown in the cross sections of Figures 10 and 11. The two depths of 16 and 19 km in the cross sections are not as well Figure 9. Histogram of the number of instrumentally located constrained. Depths for several other nearby events recorded earthquakes as a function of depth.
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1707 Figure 10. Vertical cross sections of instrumentally located earthquakes oriented perpendicular to the Ramapo fault. No vertical ex-aggeration. (a) Data from between purple kilometer markers 0 and 50 in Figure 3; (b) data from between purple markers 50 and 90.
Figure 11. Vertical cross section of instrumentally located earthquakes oriented perpendicular to line BB, the Peekskill-Stamford seis-mic boundary, of Figure 3. No vertical exaggeration.
1708 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber years (Hatcher et al., 1989). The structure and lithology left the 1957 and 2003 shocks (Fig. 1) likely occurred in those by those orogenies may influence the distribution of earth- older rocks as well. Also, few instrumentally located earth-quakes in what is now an intraplate region. The oldest rocks quakes (Fig. 3) within the Newark basin occurred on or close are found in the Reading prong-Hudson Highlands and the to the Flemington-Furlong and Hopewell intrabasinal faults Manhattan and Trenton prongs (Fig. 1). Rifting and forma- (Fig. 1). Those faults form the boundaries between three of tion of the continental margin of the Iapetus Ocean occurred the five major structural blocks of the Newark basin (Olsen during in the late Precambrian. The New York Promontory et al., 1996).
characterized the Cambrian passive continental margin of Other portions of the study area with low activity in-North America in the study area. During subsequent colli- clude the Great Valley to the northwest of the Reading prong, sional orogenies in the Paleozoic, that margin was subjected western Long Island, and the far northeastern portion of to transpressional tectonics that saw the docking of island Figure 3 in the eastern Hudson Highlands. Most of the earth-arcs, continental fragments, and possibly smaller terranes. quakes near Wappinger Falls (Wf in Fig. 2) were triggered by In contrast, the present continental margin forms an embay- quarrying (Pomeroy et al., 1976).
ment south of New York City.
By the late Triassic-early Jurassic the stress regime Ramapo Seismic Zone and Other Activity had changed, and rifting occurred during the early separation in Reading Prong of eastern North America from Africa (Manspeizer et al.,
1989). Subsequently, horizontal compression during the Ju- The Newark basin is bordered along its northwestern rassic resulted in some west-northwest-trending folds in margin by a series of right-stepping, southeast-dipping the Newark basin (Schlische et al., 2003). Stresses changed faults. We use the term Ramapo fault to refer to its again to become the current contemporary intraplate regime northeastern-most Mesozoic border fault (Fig. 1). Ratcliffe characterized by high horizontal compressive stress oriented (1971) refers to it and its multibranched northeastern exten-east-northeast but low tectonic strain (Sbar and Sykes, 1973; sions into the Hudson Highlands as the Ramapo fault zone.
Zoback, 1992). Prowell (1988) estimates the onset of the He concludes that Mesozoic activity extends for 25 km to the present stress regime sometime between the middle Jurassic northwest of the Ramapo fault. While some instrumentally and early Cretaceous. The rift-drift transition in the Jurassic located earthquakes in Figure 3 extend that far northwest, (Klitgord et al., 1988) and the ensuing and continuing most are concentrated in the eastern 12 km of the Reading growth of a huge sedimentary apron are obvious reasons prong. We follow Ratcliffe (1980) in calling that narrower for changes in the stress regime near the passive Atlantic region the RSZ; we take it to extend as far northeast as the margin. During the Pleistocene, continental glaciation ex- Hudson River.
tended as far south as Long Island and central New Jersey We concentrate on the RSZ first because its southeastern and is the most recent large perturbation of the stress field. border forms the most conspicuous alignment of instrumen-Land levels are continuing to subside (and sea level to rise) as tally located earthquakes in Figure 3. Figure 10 shows two the peripheral bulge from the last glaciation collapses. cross sections of the RSZ that are oriented perpendicular to a straight line connecting points 0 and 90 in Figure 3. That line nearly coincides with the more sinuous surface trace of Concentrations of Earthquakes in Older Terranes the Ramapo fault. In the cross section of the southwestern Most of the earthquakes in Figures 1-3 are concentrated 0-50 km of the fault (Fig. 10a), activity is abundant in a in middle-Proterozoic through Ordovician metamorphic and 12-km wide zone within Precambrian rocks between the sur-igneous rocks that are either exposed at the surface or pres- face trace of the Ramapo fault and the Green Pond syncline ent at relatively shallow depths beneath the Mesozoic and of Cambrian to Devonian rocks (Fig. 1). Because that 12-km Cenozoic rocks of the New Jersey coastal plain. The coastal width cannot be attributed to epicentral uncertainty, more plain forms a southeastward-thickening prism, which is less than one fault, likely many, must be involved in generat-than 1 km thick near the coast in the study area (Lyttle and ing its earthquakes. The depths of events with magnitudes Epstein, 1987; Volkert et al., 1996). We think earthquakes labeled 1.0 or smaller are not well constrained. The abrupt occur in stronger basement rocks below those younger sedi- southeastern boundary of the zone appears to be nearly ver-ments. Most computed hypocenters in that area are 5-10 km tical. Shallower dips are obtained, however, if the hypocen-deep, but are often poorly constrained. The well-located ters of the three small events of M 0.5, 0.6, and 1.0, in fact, Delaware-New Jersey sequence of 1973, however, was were located as deep and as far southeast as shown in 5.0-8.4 km deep, placing it in basement rocks. Figure 10a.
Rates of occurrence of events of M 3 and instrumen- Other activity in the Reading prong in Figure 10a ex-tally located shocks (Figs. 1 and 3) are very low beneath the tends as far northwest as the westernmost outcrops of Pre-Mesozoic Newark basin. To first order, it is a half graben cambrian rock. The depth of the event shown at 19 km is structure (Schlische, 1992; Olsen et al., 1996). It is bounded not well constrained. A band of high activity strikes about on the northwest by older, crystalline rocks of the Reading N10°W close to longitude 74.5° W (Figs. 2 and 3) and ex-prong. Ratcliffe et al. (1986) and Seeber (2004) deduce that tends from the Ramapo fault across the entire Reading prong.
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1709 Much of the activity in Figure 10 from 12 to 25 km northwest within older rocks of the Reading prong and not at the of the Ramapo fault occurs along that band. A left step in the Mesozoic-middle-Proterozoic boundary.
Mesozoic border fault to the south and a similar step in Proceeding southwesterly in New Jersey, fault dips at instrumentally located events from the nearly straight south- three sites along the Ramapo fault decrease from 50° to 44° eastern boundary of the RSZ (Figs. 1-3) occur near 74.5° W southeast and then to 34° at the Flemington-Furlong fault and 40.8°-40.9° N. Earthquakes are nearly absent beneath (FF in Fig. 1) and 25° to 35° southeast along the Mesozoic the wider and deeper portion of the Newark basin that is in- border fault at the Delaware River (Ratcliffe, 1980; Ratcliffe cluded in Figure 10a. Some or all of the few events in Fig- and Burton, 1984; Ratcliffe et al., 1986). The first three sites ure 3 in the eastern part of the basin may have occurred at are between purple kilometer marks 0 and 50 in Figure 3.
depth within the older rocks of the Manhattan prong. We There too, the southeastern boundary of the Ramapo seismic do not have enough depth resolution to ascertain if any zone appears to dip steeper than the Mesozoic Ramapo fault.
events occurred within Mesozoic igneous bodies such as the Palisades sill. Activity in the Manhattan Prong Figure 10b shows hypocenters in a vertical section per-The Manhattan Prong has been one of the most seismi-pendicular to and across the northeastern part of the Ramapo cally active terranes for both historic and instrumentally fault (data from 50 to 90 km in Fig. 3). An abrupt increase in located earthquakes (Figs. 1, 3, and 12). Hypocenters, like activity occurs across a nearly vertical boundary beneath the those in the Reading prong, extend from near the surface surface trace of the Ramapo fault. The 15-km depths of the to depths of 12-15 km (Figs. 10 and 11). Nearly all of the two events of M 1.5 and 2.1 are well constrained but that for earthquakes in those two terranes, as in the rest of our study the event of M 0.5 at 16 km is not. Earthquake depths de-area, appear to be confined to crystalline rocks of the upper crease systematically from a maximum of 15 km beneath the crust. Earthquakes in New England exhibit a similar depth surface trace of the Ramapo fault to about 5 km at the north-distribution (Ebel and Kafka, 1991) as do those in the western boundary of Precambrian rocks. The lower boundary Piedmont area and beneath the coastal plain from Virginia of activity beneath the Reading prong in Figure 10b appears to Georgia (Bollinger et al., 1991). The majority of earth-to dip southeasterly. It may be controlled by one or more quakes in eastern Tennessee and the adjacent Giles County Paleozoic imbricate thrust faults that sole into a master sub-seismic zone in southwestern Virginia are located at depths horizontal detachment fault whose depth seems likely to be of about 7-25 km and occur beneath the master Appalachian as great as the 12-15 km maximum depth of earthquakes decollment (Bollinger et al., 1991). Earthquakes in the Ca-beneath the Ramapo fault.
nadian Shield in southern Quebec extend to depths greater Ratcliffe (1976, 1980) and Ratcliffe and Burton (1984) than 20 km (Adams and Basham, 1991). In all of these areas examined cores from four drill holes that penetrated the earthquakes are not confined to single major through-going Mesozoic Ramapo fault to depths of up to 0.14 km. They fault but are more distributed in map view.
found no evidence of post-Jurassic displacement. Several factors could explain the apparent discrepancy between the Peekskill-Stamford Seismic Boundary distribution of earthquakes seen in Figure 10 and that lack of displacement for the last 150 Ma along this shallow portion A surprising result based on 34 yr of instrumental data of the fault. Earthquakes may be occurring either on other since 1974 is the existence of an aseismic area in the eastern preexisting subparallel faults below and to the northwest Hudson Highlands, which contains no instrumental locations of the border fault or along a series of brittle faults whose in Figure 3. It is sharply bounded on the southwest by a well-strike differs from that of the Ramapo fault. Prowell (1988) defined zone of earthquakes (between the arrows B and B estimates fault slip rates of 0:3-1:5 mm=ka since the Early in Fig. 3) that extends northwesterly from near Stamford, Cretaceous for several faults in the Atlantic coastal margin to Connecticut, to Peekskill, New York (St and Pe in Fig. 2, the south of our study area. These are 104 smaller than rates respectively). It is one of the better defined seismic bound-of seafloor spreading along the Mid-Atlantic ridge today. aries in our study. Near its western end it coincides approxi-Contemporary rates of deformation along individual faults mately with the boundary between the Manhattan prong and in the RSZ may be even smaller because earthquakes occur the Hudson Highlands, but farther east it is nearly perpendic-on many faults throughout its 12-km width. ular to and cuts across the northeasterly grain of igneous and Ratcliffe (1980) and Ratcliffe and Burton (1984) report metamorphic rocks of Precambrian to early Paleozoic age as dips of 70°, > 45°, and 55° southeast at three core locations mapped at the surface. That aseismic region is bounded on along the Mesozoic Ramapo fault between the New Jersey- the northwest by several events to the northeast of Peekskill New York border and the Hudson River (kilometer marks in the vicinity of several faults of the Ramapo fault zone 50-70 in Fig. 3). The steepest dip is found near the north- on the east side of the Hudson River (Ratcliffe, 1971). That eastern end of the Newark basin. The sharp southeastern aseismic region probably extends farther east than the eastern boundary RSZ in Figure 10b is nearly vertical and appears longitude of our study.
to be significantly steeper than at least two of those three Figure 2, which includes all earthquakes in the catalog values. Hence, we conclude that those earthquakes occur from 1677 through 2004, gives the impression that a number
1710 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber of shocks have occurred in the aseismic region of Figure 3. northwest. The strikes of nodal planes of three of those Accurate locations and depths of earthquakes, especially mechanisms are compatible with the orientation of the those east of the Hudson River, however, became available Peekskill-Stamford line.
only after the installation of a seismic station near the New It may be more than a coincidence that the northeastern York-Connecticut border in 1971. The catalog contains no end of the Newark basin occurs close to Peekskill and line events for 1970 and 1971, one well outside that aseismic BB (Fig. 3). Ratcliffe (1971) finds no evidence for Triassic region in 1973, and one of questionable accuracy within it down-dropping at the northeastern end of the Newark basin.
in 1972. The first five events in the catalog and in Figure 2 The boundary of the Manhattan prong seismicity along the (1677-1729) are reported as being felt only at single towns in Peekskill-Stamford line (Fig. 3) thus may coincide with Connecticuteither Stamford or Danbury. Given the very the northeastern end of Mesozoic extensional tectonics. The low population density at that time, we simply do not know amount of this extension, however, probably was more con-their locations, and some may have occurred far from either tinuous along the former collisional orogen, but the locus of of those towns. Locations of many other pre-1974 events extension jumped from the Newark to the Hartford, Connec-may be uncertain by 10-20 km, making them unreliable ticut, basin). The New York bight basin south of Long Island for defining the seismic-aseismic boundary seen in Figure 3. (Fig. 1) may be a continuation of the Hartford basin (Hutch-Many of the older less-accurately located events, such as the inson et al., 1986). The series of northwest-southeast strik-1845 shock of M 3.75, may have occurred along or south- ing faults across the Manhattan prong (see next section) may west of the Peekskill-Stamford seismic boundary. have served to relay strain from the Newark basin to the other The vertical cross section in Figure 11 is oriented per- two basins where they overlap along strike. If this hypothesis pendicular to the Peekskill-Stamford line. A sharp boundary is correct, all of the extension northeast of the Peekskill-between abundant activity to the southwest and none to the Stamford boundary took place east of our study area.
northeast extends from near the surface to a depth of 12-15 km. The two well-located events at depths of 15 km are Brittle Faults of Manhattan Prong situated at the intersection of the Ramapo seismic zone and the Peekskill-Stamford line just to the northwest of Peekskill Odom and Hatcher (1980), Ratcliffe (1980), and Seeber near Annsville. Seborowski et al. (1982) conclude that epi- and Dawers (1989) emphasize likely differences in the occur-centers of shallow earthquake sequences near Annsville from rence of earthquakes for two main fault typesbrittle faults 1977 to 1980 are aligned northwesterly, indicating they were that are characterized by discrete breaks and cataclastic situated along the Peekskill-Stamford boundary. fabrics as opposed to those that exhibit semiductile and An abrupt bend in the Hudson River to a northwesterly ductile behavior. The grade of Paleozoic metamorphism trend is situated near line BB of Figure 3 and is shown on the increases rapidly to the east of the Hudson River (e.g., Rod-more detailed map of Figure 12. Ratcliffe (1980) suggests gers, 1970; Ratcliffe, 1971). A number of the through-going that segment of the Hudson River is controlled by brittle frac- faults of Precambrian and early Paleozoic age in the Manhat-tures of Mesozoic age. Ratcliffe (1976) indicates a north- tan prong, the eastern Hudson Highlands, and in the Hartland westerly striking, left-lateral fault on the north side of that terrane to the east of Camerons Line (CL in Fig. 1) likely portion of the river (the short red fault in Fig. 12). An exten- were healed during the Paleozoic. The grade of Paleozoic sion of that trend to the northwest follows a major lineament metamorphism was lower in the Reading prong and the wes-that crosses the Hudson Highlands on the Preliminary Brittle tern Hudson Highlands.
Structures Map of New York (Isachsen and McKendree, The Peekskill-Stamford seismicity boundary is nearly 1977). It is shown as a fault (the longer red segment in parallel to several brittle faults of northwesterly strike in the Fig. 12) on the state geological map (Fisher et al., 1970). Manhattan prong (Fig. 12). That boundary may delineate one The Cortland igneous complex of late Ordovician-early of the most important brittle faults in the region. Known brit-Silurian age (Ratcliffe, 1971) lies along or close to the tle faults of the Manhattan prong include the 125 Street fault Peekskill-Stamford boundary. The Croton reservoir in that extends across upper Manhattan to Queens, several other Westchester County (Fig. 12) consists of two northeasterly faults in New York City, and the Dobbs Ferry fault farther striking segments and a middle, northwesterly striking part north in Westchester County (Isachsen and McKendree, that lies close to the seismic boundary. We do not know 1977; Baskerville, 1982; Fluhr and Terenzio, 1984). Geo-if that middle segment is fault controlled, but it has a geo- logic mapping in New York City water tunnels and other morphic expression much like that of the 125 Street fault in field studies indicate that these northwesterly striking brittle Manhattan. faults are the youngest structural features in the region (Mer-Seborowski et al. (1982) and Quittmeyer et al. (1985) guerian, 2004). One of them offsets a swarm of late Paleo-obtained focal mechanism solutions for two small events zoic (295 Ma) dikes in a tunnel (Merguerian, 2004).
and composite solutions for two earthquake sequences that The 1985 Ardsley earthquake occurred along the pre-occurred within the Indian Point seismic network near viously recognized west-northwest-striking Dobbs Ferry Peekskill. The solutions involve a predominance of thrust fault (Dawers and Seeber, 1991). Its mechanism involved faulting along nodal planes striking northwest to north- predominantly left-lateral strike-slip motion although cumu-
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1711 Figure 12. Brittle faults of Manhattan prong, northern Newark basin, and Reading prong from Ratcliffe (1976), Isachsen and McKendree (1977), Ratcliffe (1980), Hall (1981), Seeber and Dawers (1989), Ratcliffe (1992), Drake et al. (1996), Volkert et al. (1996), and M. N.
Ratcliffe (private comm., 2007). Lineaments determined solely from aerial and satellite images are not included. Instrumentally located events 1974-2007 with symbol type the same as in Figure 3. Place names: Croton reservoir, Cr; Hudson River, HudR; New York City, NYC; Peekskill, New York, Pe; and Stamford, Connecticut, St. Tectonic features: Dyckman Street fault, Ds; Dobbs Ferry fault, Df; Green Pond syncline, GPS; Mesozoic Ramapo fault, RF; Ramapo seismic zone, RSZ; and 125 Street fault, 125. Specific faults discussed in text are shown in orange. Area is 25% of that of Figure 1.
1712 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber lative offset of Paleozoic markers indicates right-lateral dis- The well-located 1985 shock (Fig. 1) and its aftershocks placement (Seeber and Dawers, 1989). The first motions clearly occurred to the west of Camerons Line (Seeber and of an M 2 earthquake in 1989 along the extension of the Dawers, 1989; Dawers and Seeber, 1991). The Peekskill-Dyckman Street fault (Fig. 12) in northernmost Manhattan Stamford seismic boundary (Fig. 3) cuts nearly perpendicu-indicate a large component of left-lateral strike-slip motion larly across Camerons Line. A few historic but only two along its northwesterly striking nodal plane. Merguerian and instrumentally located earthquakes have occurred near its Sanders (1997) report fault breccia 90 m thick at depth where surface trace. Because it likely was healed by Paleozoic New York City water tunnel 3 crosses the 125 Street fault. A metamorphism, it is not surprising that it is no longer a zone pronounced valley, which is partially filled by recent sedi- of brittle faulting and a source of many earthquakes.
ments, is found along that fault zone. Several small earth- The Huntingdon Valley fault zone (Fig. 1) near Phila-quakes (Figs. 3 and 12) have occurred near it. Some of the delphia and Trenton (T in Fig. 1) also separates contrasting hypocenters near the west side of the Hudson River may lie older crystalline terranethe Trenton prong to the northwest along a northwesterly extension of that fault, possibly in from the southern Piedmont to the southeast (Rodgers, 1970; rocks of the Manhattan prong beneath the shallow, northeast- Lyttle and Epstein, 1987). Rodgers (1970) suggests that it is ern part of the Newark basin. an Ordovician suture zone, which may extend beneath the Three short brittle faults (short red lines in Fig. 12) of coastal plain of New Jersey and join Camerons Line in Sta-northwesterly strike in New Jersey to the west of southern ten Island. Valentino et al. (1994) state that the fault and its Manhattan offset rocks of both the Manhattan prong and extension to the southwest into Maryland also experienced the late-Triassic Stockton formation but are not mapped as major right-lateral strike-slip offset during the late Paleozoic.
offsetting the early Jurassic Palisades sill (Drake et al., While some earthquakes such as the Abington, Pennsylva-1996; Volkert et al., 1996). This suggests that they and per- nia, sequence of 1980 occurred on or close to the Huntingdon haps some other brittle faults of the Manhattan prong were Valley fault zone, the breadth of the earthquake zone beneath formed during the early development of the Newark basin in the coastal plain of New Jersey (Fig. 1) suggests that most of the late Triassic prior to the emplacement of the Palisades that activity is not occurring along that fault zone.
sill. Manspeizer et al., (1989) and Olsen et al. (1996) date the emplacement of the sill about 20 Ma after clastic sedi-Earthquakes beneath Coastal Plain of New Jersey mentation in the basin was initiated. None of the other brit-tle faults of the Manhattan prong, however, has been shown The zone of earthquakes beneath the coastal plain con-to extend across the Hudson River and to offset Mesozoic tinues to the southwest of our study area as least as far as the rocks along its western side (Isachsen and McKendree, New Jersey-Delaware border. The basement beneath the 1977; Drake et al., 1996). Likewise, whether any of the other coastal plain of New Jersey occupies a critical position link-small faults that offset the Palisades sill on the west side of ing major Paleozoic events of the northern and central Ap-the River extend to its eastern side into the Manhattan prong palachians. Seismic reflection and refraction data indicate is not known. Better mapping and dating of these various that continental basement is present beneath the coastal plain brittle faults is important in estimating seismic risk because and continental shelf of New Jersey (Klitgord et al., 1988; one of them was the site of a moderate-size earthquake Sheridan et al., 1991; Volkert et al., 1996). Most wells that in 1985. reach the basement penetrate through the feather edge of the sedimentary wedge of the coastal plain. To the south and east few wells penetrate to the basement (Volkert et al., 1996).
Camerons Line and Huntington Valley Fault Volkert et al. (1996) make a speculative assignment of base-A major tectonic boundary, Camerons Line (CL in ment rocks beneath the coastal plain to those of exposed ter-Fig. 1), separates rocks of Precambrian and early Paleozoic ranes in the northern and central Appalachians based on the age of the Manhattan prong and Hudson Highlands on its petrology and geochemistry of samples from wells and mag-northwest from those of the Hartland terrane in Connecticut netic and gravity anomalies. They conclude that subsurface and eastern New York City (Rodgers, 1970; Baskerville, crystalline rocks beneath the coastal plain of New Jersey con-1982; Lyttle and Epstein, 1987). That zone of thrust faults sist of stacks of thrust sheets representing a composite of ac-of various dips is the site of several ultramafic bodies, includ- creted terranes.
ing a large serpentine mass on Staten Island (SI in Fig. 1). A pronounced Bouguer gravity gradient is found along Camerons Line is usually interpreted in a plate-tectonic the length of the Appalachian orogen. Cook and Oliver framework as an Ordovician (Taconic) suture zone, which (1981) conclude that it marks the eastern edge of the former involved the accretion of an island arc to the east along with late Precambrian-early Paleozoic continental margin, which intervening eugeosynclinal sediments and perhaps other is now buried at depth below near-surface, allochthonous terranes to the then passive continental margin of Lauren- crystalline rocks. A shorter-wavelength Bouguer high along tia (e.g., Drake et al., 1996). Terranes on both sides of that broad gravity gradient extends from Staten Island across Camerons Line were strongly metamorphosed during the the inner coastal plain of New Jersey (e.g., Volkert et al.,
Paleozoic. 1996). That high is nearly coincident with the band of seis-
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1713 mic activity beneath the coastal plain of New Jersey and with indicates that they are capable of generating much larger what are inferred to be crystalline rocks at depth. earthquakes.
Sheridan et al. (1991) interpret a seismic reflection pro-file and associated gravity anomalies in the coastal plain of southwestern New Jersey about 60 km south of our study Which Faults Are Active?
area as indicative of a gently, southeast-dipping detachment Cretaceous and Cenozoic faulting has been identified in fault that is underlain by Grenville-age continental crust.
the coastal plain and Piedmont from Maryland to Georgia They, like Volkert et al. (1996), deduce that imbricate thrust (Prowell, 1988). Most examples involve a predominance of faults in the upper crust above that detachment separate dip-slip reverse motion. Geological evidence of late Ceno-several allochthonous terranes of Precambrian and early zoic fault movement is poor, largely because of the limited Paleozoic age. They infer that several bodies representing distribution of markers of that age. Wherever it is available, a complex mixture of ophiolitic, metasedimentary, and however, it points to very slow rates of fault displacement in metavolcanic rocks are present beneath their seismic line.
this intraplate area. Evidence for intraplate faulting in much They conclude that the Ordovician suture zone was trans-of our study region has been destroyed by Pleistocene gla-ported northwestward later during the Paleozoic.
ciation, and most rocks outside of the coastal plain are Ju-rassic or older.
Two factors that make the field identification of Holo-Continuity of Seismic Terranes from Manhattan cene faulting difficult are the small size of ruptures of earth-Prong to Coastal Plain quakes of M 4-6 in the eastern United States and the Seismic velocities, magnetic anomaly patterns, and distribution of the seismicity on many faults each with very wells drilled to the basement indicate that the basement along low displacement rates. The rupture area of the 1985 Ardsley the coast of southwestern Long Island is composed of Paleo- shock of mb Lg 4.2 was about 0:5 km2 (Seeber and Dawers, zoic or older metamorphic and crystalline rocks (Hutchinson 1989); that for the 5.1 Adirondack, New York, event of 1983 et al., 1986; Volkert et al., 1996). Our location of the 1884 was 1 km2 (Seeber and Armbruster, 1986, 1988); and that for earthquake (Fig. 1) places it in those rocks and makes a direct the 2002 Au Sable Forks shock of 5.1 in northeastern New association with either Camerons Line or the offshore New York State was about 1:7 km2 (Seeber et al., 2002). None of York bight basin unlikely. Several small instrumentally lo- those events produced surface rupture. The latter two are cated events (Fig. 3) appear to be aligned northwesterly just comparable in magnitude to the three largest historic events to the southeast of the 1884 epicenter and may delineate the in our area.
fault along which the 1884 earthquake occurred. That align- Surface rupture in eastern and central North America has ment is roughly parallel to the strike of brittle faults farther not been identified except for a few earthquakes of M 6-8.
north in the Manhattan prong. Aftershocks of the 1884 event, Shocks in that region typically have smaller dimensions and however, were felt more strongly either near the adjacent larger stress drops and are felt to larger distances than those coast of New Jersey or near the coast of Long Island (Nottis of comparable magnitude in the western United States and Mitronovas, 1983), suggesting a rupture zone striking (Atkinson and Wald, 2007). Thus, the occurrence of earth-northeasterly. Marine studies of that area and more reliable quakes of M 5-6 in our area does not require great fault hypocenters and earthquake mechanisms are of high priority lengths, merely rupture zones about 1-10 km in length.
in understanding earthquake risk to New York City. Many faults and segments of longer faults are possible can-None of the known shocks of M 3 (Fig. 1) since 1800 didates for shocks of those magnitudes. Detecting Holocene occurred between the Westchester earthquake of 1985 and fault displacement at or near the surface will continue to be the 1884 and 1937 events farther south. The uncertainty in very difficult. Other methods must be used to ascertain which the location of the 1737 event is large enough that it may or faults are either active or potentially active.
may not have occurred in New York City, but smaller instru-mentally located events have (Fig. 3). The simplest interpre-tation is that the array of brittle cross faults that characterizes Contemporary State of Stress the Manhattan prong through New York City is associated and Earthquake Generation with the colocated belt of seismicity and that the seismogenic The orientation and magnitudes of principal stresses in potential of these faults is similar. This association has been the crust are vital in understanding contemporary fault activ-demonstrated for the Dobbs Ferry fault. Southwest of the ity. Knowledge of in situ stresses in our study area, however, 1884 earthquake the seismicity continues below the coastal continues to be poor to modest. The occurrence of rock plain of New Jersey, and the belt of cross faults may continue bursts during the construction of major water tunnels in hard as well. If this hypothesis is correct, the seismic potential of rock (e.g., Berkey and Rice, 1919) is indicative qualitatively these faults can be estimated from the seismicity and from of high compressive stress as are results from hydrofracture their geologic characteristics. The length of several of these experiments in our study area and elsewhere in the eastern faults far exceeds the inferred sizes of historic ruptures and United States (Zoback, 1992).
1714 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber Combining a variety of stress measurements, Sbar and faulting of either north or north-northeast strike. The occur-Sykes (1973) found that maximum compressive stress, 1 , is rence of those two types of faulting indicates that maximum nearly horizontal and is oriented about east-northeast in a compressive stress, at least in that immediate area, is large large area of eastern North America including northern and whereas the two other principal stresses are smaller and of western New York State. Based on very limited data Sbar and comparable size. The other focal mechanisms for which P Sykes (1977) concluded the state of stress differs in our study axes are shown in Figure 1 involved a predominance of re-area, New England and Virginia. From studies of mechan- verse faulting. All but one of them was from an earthquake of isms of small earthquakes using only P-wave first mo- very shallow depth. Likewise, the hydrofracture and bore-tions Aggarwal and Sykes (1978) and Yang and Aggarwal hole breakout measurements were all made within the upper (1981) concluded that 1 in our area is oriented east to 1 km. Because the least compressive stress is likely to be east-southeast. Reliable mechanisms are rare, however, given vertical at very shallow depths, dip-slip reverse or thrust the small shallow earthquakes and widely spaced stations faulting is likely.
typical of our area. Near-vertical strike-slip faults striking about west to Subsequent work indicates that 1 likely is oriented west-northwest and north-northeast to northeast that have northeast to east. The first 19 entries in Table 4 (in the not been healed by high-grade metamorphism should be electronic edition of BSSA) compile P axes of selected focal oriented favorably for rupture in a contemporary stress field mechanisms and hydrofracture and borehole breakout mea- oriented about N64°E (assuming hydrostatic pore pressure surements of 1 for areas adjacent but outside our study re- and a coefficient of friction of about 0.6). This would include gion. The distribution of those stress indicators is similar to west-northwest left-lateral strike-slip faulting in the Manhat-those in maps by Zoback (1992) and Du et al. (2003). The tan prong, as in the 1985 earthquake. Likewise, thrust faults last nine entries in Table 4 (in the electronic edition of dipping about 30° and striking nearly perpendicular to 1 BSSA) are from our study area and are shown in Figure 1. also would be favorably oriented. Clear examples of Creta-Mechanisms were selected only if they were obtained either ceous and Cenozoic thrust faulting of shallow dip in the by waveform matching (Du et al., 2003) or by using data Appalachians (Odom and Hatcher, 1980), however, are lack-from a network of very close-in stations (i.e., either after- ing. Generally geologic data and focal mechanisms are in-shocks recorded by temporary deployments of seismographs consistent with the current reactivation of shallow-dipping or events beneath the dense Indian Point network). Those Paleozoic and Precambrian thrust faults in the Appalachians, mechanisms typically have a wider coverage of data on most of which are of northeasterly strike. Reverse motion on the focal sphere and more accurately determined depths than steeply dipping, preexisting faults striking north to northwest those derived only from first-motions of individual events. is consistent with 1 oriented about N64°E as in several of All of the P axes in Table 4 (in the electronic edition the mechanisms in Figure 1. Strike slip or oblique slip is also of BSSA) are nearly horizontal. P axes, however, need not possible on north-northeast-striking brittle faults of steep dip be parallel to 1 for preexisting faults (Michael, 1984). in the Manhattan prong that are younger than 295 Ma An average of the azimuths of 19 values of 1 and P (Merguerian, 2004) but older than the northwesterly striking axes for the region outside our study area is N67°E 16° brittle faults described earlier.
(1 standard deviation) with a standard error of the mean The Ramapo seismic zone and the Ramapo fault strike (SEM) of 4°. An average of nine azimuths (Fig. 1) for our about N40°E. The azimuths of 1 for the hydrofracture mea-area is N64°E 16°, SEM 5°. We omitted the composite surement (Zoback et al., 1985) to the northeast of Peekskill mechanism for one very small earthquake and its aftershocks and the one borehole breakout determination (Goldberg et al.,
in 1969 that involved normal faulting (Sbar et al., 1970), a 2003) are nearly parallel to the Ramapo fault (Fig. 1). If those completely different mechanism from that of others in the azimuths, rather than the average of N64° E obtained earlier, study area. Seeber et al. (1998) obtained an azimuth of are indicative of the orientation of 1 , contemporary faulting N68°E 5° from inferred slip planes of seven focal mechan- striking subparallel to the Ramapo trend is unlikely. Another isms in our area, Pennsylvania, and Maryland using the tech- possibility is that earthquakes within the RSZ are occurring nique of Michael (1984). The three sets of results are nearly along left-lateral strike-slip faults of northwesterly strike like identical. A number of breakout measurements in boreholes those in the Manhattan prong. Some faults of northwesterly along the outer continental shelf to the southeast of Figure 1 strike occur within the Newark basin (Fig. 12), but those near also indicate that 1 is oriented northeasterly (Zoback, 1992). the Ramapo fault are not mapped by Fisher et al. (1970),
The azimuth of 1 may vary within our region, but we cannot Schlische (1992), or Drake et al. (1996) as cutting across as yet separate measurement uncertainties from intrinsic it into the Reading prong.
spatial variations. The Ramapo fault zone experienced repeated defor-The mechanism of the 1985 Ardsley earthquake in- mation from the Precambrian to the Jurassic (Ratcliffe, volved left-lateral strike-slip motion along a fault striking 1971, 1980). Significant post-middle Ordovician right-lateral west-northwest at a depth of 5 km. That of a large aftershock strike-slip faulting has occurred along that zone (Ratcliffe, involved a combination of reverse and strike-slip motion. 1971, 1980; Ratcliffe and Burton, 1984). If 1 is oriented Mechanisms of later aftershocks abutting it displayed reverse about N64°E, contemporary right-lateral, strike-slip faulting
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1715 is possible within crystalline rocks of the Reading prong Low Activity in Newark Basin and Great Valley along preexisting, subvertical, brittle faults oriented sub-parallel to the Ramapo fault. The straight, nearly vertical It is important to address why so many earthquakes have southeastern boundary of the Ramapo seismic zone suggests occurred within crystalline terranes in our study area, so few that mode of contemporary deformation. beneath much of the Newark basin and even fewer in the Ratcliffe (1980) states that current seismic activity along Great Valley to the northwest of the Reading prong. Most the Ramapo fault zone may be more strongly controlled by of the instrumentally located earthquakes beneath the New-the presence of through-going crustal structures than it is by ark basin (Fig. 3) occurred near its northeastern end where more superficial Mesozoic faults. His conclusion agrees with its basement shoals and crystalline rocks of the Manhattan our finding that most, and perhaps all, earthquakes near the prong are found beneath the thin Mesozoic section. In con-Mesozoic border faults appear to be occurring within crystal- trast, Lyttle and Epstein (1987) and Drake et al. (1996) in-line rocks of the Reading prong and not at the northwestern dicate maximum thicknesses of Mesozoic rocks of 6-8 km boundary of Mesozoic rocks. Not having activity along the for five cross sections of the Newark basin farther southwest.
Ramapo and other border faults just at the boundary between Schlische (1992) obtains a thickness greater than 6 km from Mesozoic and older rocks is not surprising because very a seismic reflection profile across the central part of the basin few earthquakes occur within Mesozoic rocks of the New- southwest of the Delaware River. Crystalline Proterozoic and ark basin. early Paleozoic rocks are thought to be present beneath the Seeber and Armbruster (1985, 1986) and Armbruster basin (e.g., Lyttle and Epstein, 1987; Drake et al., 1996).
and Seeber (1987) found that aftershocks and a nodal plane Sedimentary rocks, which constitute most of the thickness of of a focal mechanism solution for the Martic, Pennsylvania, the Newark series, either may not be strong enough to store earthquake sequence in 1984, about 75 km to the west of our large tectonic stresses or their rheology places them in the study area, were aligned north to north-northeast, nearly velocity-strengthening regime. Also, they may lack enough parallel to the strike of a prominent Jurassic dike. The fault preexisting faults of appropriate orientation to permit rupture deduced from those data dipped steeply and involved a com- in response to the present stress regime.
bination of reverse and right-lateral strike-slip motion. The P This leaves unanswered the low level of seismicity be-axis of the mechanism was oriented N70°E, similar to the neath the deeper parts of the Newark basin from the base of average 1 in our study area. Accurate isotopic dating indi- Mesozoic rocks to depths of 12-15 km as in the RSZ and the cates that igneous bodies in the Newark and several other Manhattan prong. The very few earthquakes beneath the Mesozoic basins were emplaced during a brief interval of Cambro-Ordovician rocks of the Great Valley (Fig. 1) may about 0.6 Ma in the early Jurassic about 20 Ma after clastic be a clue to the low level beneath much of the Newark basin.
sedimentation in those basins was initiated (Olsen et al., Major thrust and detachment faults along some of the weaker 1996; Schlische et al., 2003). The source of their magmas lower Paleozoic formations (e.g., Lyttle and Epstein, 1987; ultimately must have been the upper mantle. Their emplace- Costain et al., 1989) may decouple them from stresses at ment is a rather distinct and different event than the much depth. The previous three reasons also may explain the slower development of the basins themselves. The dikes at low activity. Lyttle and Epstein (1987) show about 4 km depth that presumably fed those igneous rocks may have of Cambro-Ordovician rocks beneath the Newark basin utilized preexisting, near-vertical faults in the crust. It is on their section BB. Thus, the combined thicknesses of unlikely, however, that those dikes were injected along Cambro-Ordovician and Mesozoic rocks along that section shallowly dipping faults of Mesozoic or older age. We sug- approaches the maximum depth of earthquakes in the RSZ.
gest that the straight, nearly vertical southeastern boundary Cambro-Ordovician and Precambrian rocks outcrop within of the Ramapo seismic zone (Fig. 3) may coincide with one the Newark basin in Buckingham Valley (BV in Fig. 1).
or more major dikes that fed sills, stocks, and lava flows into Lyttle and Epstein (1987) describe the former as Taconic-like adjacent sections of the Newark basin. rocks. Similar rocks are found on the west side of the Newark Two mechanism solutions and orientations of aftershock basin. Such Taconic rocks were encountered in the Paresstis zones are available for other parts of the Newark basin. The exploration well in the southwestern part of the Newark basin 2003 earthquake (Fig. 1) involved reverse faulting of north- (P. Olsen, private comm., 2007). Thus, Cambro-Ordovician west to west-northwest strike (Seeber, 2004), which is nearly rocks may be extensive beneath the deeper parts of the New-perpendicular to the nearby border fault. Because that border ark basin and may account for the small numbers of earth-fault strikes about N68°E, it is unlikely to be active if 1 is quakes there.
oriented about N64°E. To the west of our study area where border faults strike nearly east-west near Reading, Pennsyl- Conclusions and Discussion vania, the focal mechanism and aftershocks of an earthquake in 1994 indicate a combination of reverse and strike-slip Historic and instrumental data on earthquakes in the motion on a fault striking northwesterly. Thus, which faults greater New York-Philadelphia area are cataloged in terms are active today in the Reading prong depends critically on of a common magnitude scale, mb Lg. At the continental di-their strike and dip and the orientation of 1 . mension, this zone is one of a few earthquake source areas
1716 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber that stand out from the low intraplate seismicity background plate activity. Our sense is that the mapping of brittle faults, of the eastern United States. Most earthquakes within this especially in older crystalline terranes in the study area is still zone are shallow (94% are 10 km deep) and occur in older in its infancy.
crystalline basement rocks of the upper crust. They are con- Earthquakes do not occur continuously along either the centrated in areas where these rocks are exposed, in the Man- Appalachians or the coastal plain. Using those physiographic hattan and Reading prongs, or where they occur at shallow features by themselves for purposes of defining contempor-depth below coastal plain sediments of New Jersey and ary tectonic behavior and earthquake occurrence is not jus-southwestern Long Island. Seismicity is much lower in the tified. The use of terranes of older stronger rocks that also eastern Hudson Highlands where crystalline rocks are ex- have been the loci of historic seismic activity are more ap-posed at the surface and where they are more deeply buried, propriate for calculating probabilistic seismic hazards. Fu-such as beneath the Newark basin and beneath the Cambro- ture estimates of earthquake hazards and risks need to take Ordovician rocks of the Great Valley to the northwest of the into account the quite different levels of activity within our Reading prong. Distinction needs to be made in hazard as- study area and their significance in terms of potential source sessments between these more active and less active terranes. terranes and faults.
Earthquake locations using 34 yr of data from a local Several damaging historic earthquakes and a sustained network, delineate a number of features that were not re- relatively high level of instrumental seismicity point to a con-solvable solely with historic data. Instrumentally located ac- centration of earthquake hazard in the seismic zone that ex-tivity along the Ramapo seismic zone is concentrated in a tends along the Manhattan prong to south of New York City 12-km wide band in older rocks of the eastern Reading prong and then beneath the coastal plain of New Jersey. Surpris-between the surface trace of the Mesozoic Ramapo fault and ingly, few modern geophysical data are available, however, the Green Pond syncline. The southeastern boundary of that considering the huge population and assets at risk. This is activity, which extends from near the surface to depths of 12- particularly so for the region of the 1884 earthquake just to 15 km, dips very steeply to the southeast, typically greater the south of New York City and the seismic zone beneath the than the dip of the Mesozoic border fault. That activity is coastal plain of New Jerseyparts of the northeast corridor.
attributed to faults of as yet poorly determined strike within No seismic stations are operating in that part of the coastal that part of the Reading prong. Seismicity is nearly absent in plain. Monitoring and knowledge of earthquakes in our in-the Mesozoic sedimentary rocks of the Newark basin and in traplate area is far behind those efforts in California and Ja-Cambro-Ordovician rocks inferred beneath them. This is at- pan. Knowledge of which faults are active is in its infancy, tributed to either those rocks being relatively weak, in the and high-quality data on in situ stress are few. The accuracy velocity-strengthening rheological regime, being decoupled of focal depths needs to be improved.
from the basement beneath them by thrust and/or detach- National priorities for geophysical and geological work ment faults along weak layers, or a lack of preexisting brittle and monitoring have been and continue to be based much faults that are suitably oriented with respect to contemporary more on hazard than risk. For example, the low priority stresses. Because intraplate strain rates are extremely slow of earthquake research and monitoring in New York City and geologic deformation since the Mesozoic is largely lack- contrasts with high estimated annualized earthquake losses ing, it may be useful to explore why a geologic terrane is based on HAZUS calculations by the Federal Emergency seismically active and why another is not. Management Agency (FEMA) (2001). Their estimates A newly identified featurethe Peekskill-Stamford rank New York City eleventh out of 40 U.S. cities. In seismic boundaryis nearly vertical, extends from near the comparison, Philadelphia and Newark are thirtieth and surface to depths of about 12-15 km, and is subparallel to thirty-sixth, St. Louis is sixteenth, Boston is twenty-fifth, several brittle faults farther south in the Manhattan prong. Memphis is twenty-ninth, and Charleston, South Carolina, Instrumentally located earthquakes are relatively abundant is thirty-fourth.
in the Manhattan and Reading prongs but not in the eastern Tantala et al. (2003) used HAZUS with a modified build-Hudson Highlands to the northeast of that line. A brittle fault ing stock for the metropolitan New York area to estimate that crosses the Reading prong lies along the northwest ex- losses for earthquakes of moment magnitude (Mw ) 5, 6, tension of that line (Fig. 12). Seismic activity is low farther and 7 at the site of the 1884 shock as well as probabilistic north in older crystalline rocks of the Green Mountains and calculations for average return periods of 100, 500, and the Berkshire and Housatonic highlands (Seeber and Arm- 2500 yr. For Mw 6 and 7 events at the site of the 1884 shock, bruster, 1988). While seismicity in our study area seems to they calculate losses from buildings and income of $39 and originate exclusively within old strong basement rocks of the $197 billion, respectively. The addition of infrastructural upper crust, the presence of such rocks at or near the surface losses would about double those figures (K. Jacob, private appears to be a necessary, but not a sufficient, condition for comm., 2007). Their region of investigation did not include the occurrence of earthquakes. Some other factors, such as Philadelphia and Trenton, as ours did. Extrapolated repeat either the magnitude and/or orientation of principal stresses times in our study area for events of mb Lg 6 and 7 are about and the presence of brittle faults of appropriate orientation 670 and 3400 yr, respectively. The corresponding probabil-also must be important in generating varying levels of intra- ities of occurrence in a 50-yr period are about 7% and 1.5%,
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1717 respectively. The probability of an earthquake the same size Bischke, R. E., A. L. Kafka, and E. Schlesinger-Miller (1980). The Abing-ton, PA earthquake sequence of March 1980, Earthq. Notes 51, 12-13 as the 1884 event, mb Lg 5.25, during a 50-yr period is about (abstract).
22%. Calibrating Mw in terms of mb Lg is difficult for our Bollinger, G. A. (1979). Attenuation of the Lg phase and the determination region because few determinations of Mw are available even of mb in the southeastern United States, Bull. Seismol. Soc. Am. 69, for neighboring regions. Existing data indicate that Mw is 45-63.
typically somewhat smaller than mb Lg. Bollinger, G. A., A. C. Johnston, P. Talwani, L. T. Long, K. M. Shedlock, M.
S. Sibol, and M. C. Chapman (1991). Seismicity of the southeastern Two nuclear power plants at Indian Point (near Peekskill United States; 1698 to 1986, in Neotectonics of North America, D. B.
in Fig. 2) are located closer to more people at any given dis- Slemmons, E. R. Engdahl, M. D. Zoback and D. D. Blackwell (Edi-tance than any other similar facilities in the United States. tors), Geological Society of America, Boulder, Colorado, 291-308.
Entergy, their owner, recently applied for 20-yr extensions of Chaplin, M. P., S. R. Taylor, and M. N. Toksz (1980). A coda-length their existing 40-yr licenses. Much new seismological infor- magnitude scale for New England, Earthq.Notes 51, 15-22.
Chiburis, E. F., and R. O. Ahner (1976). UCONN-NUREG 0208-002, mation is available since their initial approvals in 1973 and Northeastern U.S. Seismic Network, Bulletin of Seismicity, October-1975. Nevertheless, the U.S. Nuclear Regulatory Commis- December, 1975, U.S. Nuclear Regulatory Commission.
sion so far has not permitted any new information to be used Community Internet Intensity Map Working Group (2006). Community In-or old information on which the original licenses were based ternet Intensity Map, 1992-2006, http://pasadena.wr.usgs.gov/shake to be contested in considering extensions of licenses. Indian (last accessed January 2007).
Point is situated at the intersection of the two most striking Cook, F. A., and J. E. Oliver (1981). The late Precambrian-early Paleo-zoic continental edge in the Appalachian orogen, Am. J. Sci. 281, linear features marking the seismicity (Fig. 3) and also in the 993-1008.
midst of a large population that is at risk in case of an ac- Costain, J. K., R. D. Hatcher Jr., C. Coruh, T. L. Pratt, S. R. Taylor, J. J.
cident to the plants. This is clearly one of the least favorable Litehiser, and I. Zietz (1989). Geophysical characteristics of the Ap-sites in our study area from an earthquake hazard and risk palachian crust, in The Geology of North America, The Appalachian-Ouachita Orogen in the United States, R. D. Hatcher Jr, W. A. Thomas perspective.
and G. W. Viele (Editors), Vol. F-2, Geological Society of America, Acknowledgments Boulder, Colorado, Chap. 8, 385-416.
Dawers, N. H., and L. Seeber (1991). Intraplate faults revealed in crystalline We thank K. Jacob, T. Engelder, P. Olsen, N. Ratcliffe, D. Walker, and bedrock in the 1983 Goodnow and 1985 Ardsley epicentral areas, New an unknown reviewer for critically reading the manuscript. We also thank York, Tectonophysics 186, 115-131.
M. Anders, J. Cochran, D. Kent, and G. Mountain for helpful discussions. Dewey, J. W., and D. W. Gordon (1984). Map showing recomputed hypo-Many people and institutions were involved since 1974 in operating the seis- centers of earthquakes in the eastern and central United States and ad-mic stations and analyzing data from the network. We thank G. Yetman and jacent Canada, 1925-1980, U.S. Geological Survey Miscellaneous R. Chen for calculations of population. Funds for operating stations and Field Studies Map MF-1699.
analyzing data were provided at various times by the Sloan Foundation, Drake, A. A., Jr., R. A. Volkert, D. H. Monteverde, G. H. Herman, H. F.
U.S. Nuclear Regulatory Commission, U.S. Army Corp of Engineers, New Houghton, R. A. Parker, and R. F. Dalton (1996). Bedrock geology York State Energy Research and Development Authority, National Science map of Northern New Jersey, U.S. Geological Survey Map I-2540-A, Foundation, and U.S. Geological Survey (currently through Cooperative scale 1:100,000.
Agreement Number 07HQAG0021). This article is Lamont-Doherty Earth Du, W.-X., W.-Y. Kim, and L. R. Sykes (2003). Earthquake source param-Observatory Contribution Number 7140. eters and state of stress for the northeastern United States and south-eastern Canada from regional seismograms, Bull. Seismol. Soc. Am.
93, 1633-1648.
References Ebel, J. E. (1982). ML measurements for northeastern United States earth-Adams, J., and P. Basham (1991). The seismicity and seismotectonics of quakes, Bull. Seismol. Soc. Am. 72, 1367-1378.
eastern Canada, in Neotectonics of North America, D. B. Slemmons, Ebel, J. E., and A. L. Kafka (1991). Earthquake activity in the northeastern E. R. Engdahl, M. D. Zoback and D. D. Blackwell (Editors), Geo- United States, in Neotectonics of North America, D. B. Slemmons, logical Society of America, Boulder, Colorado, 261-276. E. R. Engdahl, M. D. Zoback and D. D. Blackwell (Editors), Geolog-Aggarwal, Y. P., and L. R. Sykes (1978). Earthquakes, faults and nuclear ical Society of America, Boulder, Colorado, 277-290.
power plants in southern New Yorknorthern New Jersey, Science Ebel, J. E., P. G. Sommerville, and J. D. McIver (1986). A study of the 200, 425-429. source parameters of some large earthquakes of northeastern North Aki, K. (1965). Maximum likelihood estimate of b in the formula America, J. Geophys. Res. 91, 8231-8247.
log N a bM and its confidence limits, Bull. Earthq. Res. Inst. Federal Emergency Management Agency (FEMA) (2001). HAZUS 99 Tokyo Univ. 43, 237-239. estimated annualized earthquake losses for the United States, Fed-Armbruster, J. G., and L. Seeber (1986). A new algorithm for source pa- eral Emergency Management Agency, Washington, D.C., Publica-rameters from intensity data: tests and results in the southeastern tion 366.
U.S., Earthq. Notes 57, 19. Fisher, D. W., Y. W. Isachsen, and L. V. Richard (1970). Geological map of Armbruster, J. G., and L. Seeber (1987). The 23 April 1984 Martic earth- New York State, lower Hudson sheet, New York State Museum and quake and the Lancaster seismic zone in eastern Pennsylvania, Bull. Science Service Map and Chart Series 15, scale 1:250,000.
Seismol. Soc. Am. 77, 877-890. Fluhr, T. W., and V. G. Terenzio (1984). Engineering geology of the New Atkinson, G. M., and D. J. Wald (2007). Did you feel it? intensity data: a York City water supply system, New York State Geol. Surv. Open-File surprisingly good measure of earthquake ground motion, Seism. Res. Rept. 05.08.001, 183 pp.
Lett. 78, 362-368. Frankel, A. D., M. D. Petersen, C. S. Mueller, K. M. Haller, R. L. Wheeler, Baskerville, C. A. (1982). The foundation geology of New York City, Rev. E. V. Leyendecker, R. L. Wesson, S. C. Harmsen, C. H. Cramer, D. M.
Eng. Geol. 5,95-117. Perkins, and K. S. Rukstales (2005). Seismic-hazard maps for the con-Berkey, C. P., and M. Rice (1919). Geology of the West Point quadrangle terminous United States, U.S. Geol. Surv. Scientific Investigations N.Y., Bull. N.Y. State Mus. 225-226, 1-152. Map 2883.
1718 L. R. Sykes, J. G. Armbruster, W.-Y. Kim, and L. Seeber Goldberg, D., T. Lupo, M. Caputi, C. Barton, and L. Seeber (2003). Stress Pomeroy, P. W., D. W. Simpson, and M. L. Sbar (1976). Earthquakes trig-regimes in the Newark basin rift: evidence from core and downhole gered by surface quarrying: the Wappinger Falls, New York sequence data, in The Great Rift Valleys of Pangea in Eastern North America, of June 1974, Bull. Seismol. Soc. Am. 66, 685-700.
P. M. LeTourneau and P. E. Olsen (Editors), Tectonics, Structure, and Prowell, D. C. (1988). Cretaceous and Cenozoic tectonism on the Atlantic Volcanism, Vol. 1, Columbia University Press, New York, 104-117. coastal margin, in The Geology of North America, The Atlantic Con-Hall, L. M. (1981). Geology of the White Plains quadrangle New York, tinental Margin, R. E. Sheridan and J. A. Grow (Editors), Vol. I-2, New York State Geol. Surv. Open-File Rept. 1g1366. Geological Society of America, Boulder, Colorado, 557-564.
Hatcher, R. D., Jr (1989). Tectonic synthesis of the U. S. Appalachians, in Prucha, J. J., D. M. Scotford, and R. M. Sneider (1968). Bedrock geology of The Geology of North America, The Appalachian-Ouachita Orogen in parts of Putnam and Westchester counties, New York, and Fairfield the United States, Hatcher, R. D., Jr., W. A. Thomas, and G. W. Viele county, Connecticut, New York State Museum and Science Service (Editors), Vol. F-2, Geological Society America, Boulder, Colorado, Map and Chart Series 11, 26 pp.
Chap. 14, 511-535. Quittmeyer, R. C., C. T. Stratton, K. A. Mrotek, and M. Houlday (1985).
Hutchinson, D. R., K. D. Klitgord, and R. S. Detrick (1986). Rift basins of Possible implications of recent microearthquakes in southern New the Long Island platform, Bull. Geol. Soc. Am. 97, 688-702. York State, Earthq. Notes 56, 35-42.
Isachsen, Y. W., and W. G. McKendree (1977). Preliminary brittle structures Ratcliffe, N. M. (1971). The Ramapo fault system in New York and adjacent map of New York, New York State Museum and Science Service, Map northern New Jerseya case of tectonic heredity, Bull. Geol. Soc. Am.
Chart 31, scale 1:250,000. 82, 125-142.
Isacks, B., and J. Oliver (1964). Seismic waves with frequencies from 1 to Ratcliffe, N. M. (1976). Final report on major fault systems in the vicinity 100 cycles per second recorded in a deep mine in northern New Jersey, of Tompkins Cove-Buchanan, New York, written document submit-Bull. Seismol. Soc. Am. 54, 1941-1979. ted to Consolidated Edison of New York, Inc., June 24, 157 pp. plus Kafka, A. L., E. A. Schlesinger-Miller, and N. L. Barstow (1985). 2 plates.
Earthquake activity in the greater New York City area: magnitudes, Ratcliffe, N. M. (1980). Brittle faults (Ramapo fault) and phyllonitic ductile seismicity, and geologic structures, Bull. Seismol. Soc. Am. 75, shear in the basement rocks of the Ramapo seismic zone, New York 1285-1300. and New Jersey, and their relationship to current seismicity, in Field Kim, W.-Y. (1998). The ML scale in eastern North America, Bull. Seismol. Studies of New Jersey Geology and Guide to field trips: 52nd Annual Soc. Am. 88, 935-951. Meeting New York State Geological Assoc., W. Manspeizer (Editor),
Klitgord, K. D., D. R. Hutchinson, and H. Schouten (1988). U. S. Atlantic 278-312.
continental margin; structural and tectonic framework, in The Geology Ratcliffe, N. M. (1992). Bedrock geology and seismotectonics of the Osca-of North America, The Atlantic Continental Margin, R. E. Sheridan wana Lake quadrangle, New York, U.S. Geol. Surv. Bull. 1941, 38.
and J. A. Grow (Editors), Vol. I-2Geological Society America, Ratcliffe, N. M., and W. C. Burton (1984). Fault reactivation models for Boulder, Colorado, 19-55. origin of the Newark basin and studies related to eastern U.S. seismic-Lyttle, P. T., and J. B. Epstein (1987). Geological map of the Newark 1° x 2° ity, U.S. Geol. Surv. Circular 946, 36-45.
quadrangle, New Jersey, Pennsylvania, and New York, U.S. Geol. Ratcliffe, N. M., W. C. Burton, R. M. DAngelo, and J. K. Costain (1986).
Surv. Misc. Investigations Series, I-1715. Low-angle extensional faulting, reactivated mylonites, and seismic re-Manspeizer, W., J. DeBoer, J. K. Costain, A. J. Froelich, C. Coruh, flection geometry of the Newark basin margin in eastern Pennsylvania, P. E. Olsen, G. J. McHone, J. Puffer, and D. C. Prowell (1989). Post- Geology 14, 766-770.
Paleozoic activity, Chapter 6, in The Geology of North America, The Rockwood, C. G. (1872-1886). Notes on recent American earthquakes, Appalachian-Ouachita Orogen in the United States R. D. Hatcher Jr., Am. J. Sci. 4-32 (this reference covers many entries over the cited W. A. Thomas and G. W. Viele (Editors), Vol. F-2, Geological Society 15 year period and therefore specific page numbers are not given).
of America, Boulder, Colorado, 319-374. Rodgers, J. (1970). The Tectonics of the Appalachians, Wiley-Interscience, Merguerian, C. (2004). Brittle fault chronology of New York City (NYC), New York, 271 pp.
Geol. Soc. Am. Abstr. Programs 36, 73. Rundle, T. A., M. M. Singh, and C. H. Baker (1987). NUREG/CR 4623, Merguerian, C., and J. E. Sanders (1997). Bronx River diversion: Neotec- In-situ stress measurements in the earths Crust in the eastern United tonic implications, Int. J. Rock Mech. Miner. Sci. 34, no. 3-4, 11. States, U.S. Nuclear Regulatory Commission, 687 pp.
Michael, A. J. (1984). Determination of stress from slip data, J. Geophys. Sbar, M. L., and L. R. Sykes (1973). Contemporary compressive stress and Res. 89, 11,517-11,526. seismicity in eastern North America: an example of intraplate tec-Nottis, G. N. (1983). Epicenters of northeastern United States and southeast- tonics, Bull. Geol. Soc. Am. 84, 1861-1882.
ern Canada, onshore and offshore; time period 1534-1980, New York Sbar, M. L., and L. R. Sykes (1977). Seismicity and lithospheric stress in State Museum Map and Chart Series 38, 1-39. New York and adjacent areas, J. Geophys. Res. 82, 5751-5786.
Nottis, G. N., and W. Mitronovas (1983). Documentation of the felt earth- Sbar, M. L., R. R. Jordan, C. D. Stephens, T. E. Pickett, K. D. Woodruff, and quakes in the coastal Plain of southeastern New York and east central C. G. Sammis (1975). The Delaware-New Jersey earthquake of Feb-New Jersey: 1847-1954, New York State Geol. Surv. Open-File Rept. ruary 28, 1973, Bull. Seismol. Soc. Am. 65, 85-92.
203.002, 74 pp. Sbar, M. L., J. M. W. Rynn, F. J. Gumper, and J. C. Lahr (1970). An earth-Nuttli, O. W. (1973). Seismic wave attenuation and magnitude relation for quake sequence and focal mechanism solution, Lake Hopatcong, eastern North America, J. Geophys. Res. 78, 876-884. northern New Jersey, Bull. Seismol. Soc. Am. 60, 1231-1243.
Nuttli, O. W., and J. E. Zollweg (1974). The relationship between felt area Schlische, R. W. (1992). Structural and stratigraphic development of the and magnitude for central United States earthquakes, Bull. Seismol. Newark extensional basin, eastern North America: evidence for the Soc. Am. 64, 73-85. growth of the basin and its bounding structures, Bull. Geol. Soc.
Odom, A. L., and R. D. Hatcher Jr (1980). NUREG/CR 1621, A character- Am. 104, 1246-1263.
ization of faults in the Appalachian foldbelt, U.S. Nuclear Regulatory Schlische, R. W., M. O. Withjack, and P. E. Olsen (2003). Relative timing of Commission, 314 pp. CAMP, rifting, continental breakup, and basin inversion: tectonic sig-Olsen, P. E., D. V. Kent, B. Cornet, W. K. Witte, and R. W. Schlische (1996). nificance, in The Central Atlantic Magmatic Province: Insights from High-resolution stratigraphy of the Newark rift basin (early Mesozoic, Fragments of Pangea, W. Hames, J. G. McHone, P. Renne and C. Rup-eastern North America), Bull. Geol. Soc. Am. 108, 40-77. pel (Editors), American Geophysical Monograph 136, 33-59.
Page, R. A., P. H. Molnar, and J. Oliver (1968). Seismicity in the vicinity of Schnerk, R., M. L. Sbar, F. England, and M. Golisano (1976). Local earth-the Ramapo fault, New Jersey-New York, Bull. Seismol. Soc. Am. 58, quakes recorded in New York State and adjacent areas, 1975, Regional 681-687. Seismicity Bulletin of the Lamont-Doherty Network, 26 pp.
Observations and Tectonic Setting of Historic and Instrumentally Located Earthquakes 1719 Seborowski, K. D., G. Williams, J. A. Kelleher, and C. T. Statton (1982). Street, R. L., and A. Lacroix (1979). An empirical study of New England Tectonic implications of recent earthquakes near Annsville, New York, seismicity: 1727-1977, Bull. Seismol. Soc. Am. 69, 159-175.
Bull. Seismol. Soc. Am. 72, 1601-1609. Street, R. L., and F. T. Turcotte (1977). A study of northeastern North Seeber, L. (2004). Characterizing very shallow earthquakes in the northeast- America spectral moments, magnitudes, and intensities, Bull. Seismol.
ern US: a swarm below the Delaware River near the border fault of the Soc. Am. 67, 599-614.
Newark basin, NJ & PA, written proposal to U.S. Geological Survey, Sykes, L. R. (1976). The capability of the Ramapo fault, written testimony 23 pp. before the Atomic Safety and Licensing Appeal Board, U.S. Nuclear Seeber, L., and J. Armbruster (1985). Spatio-temporal distribution of seis- Regulatory Commission, May 26.
micity along the Appalachians and the case for detachment reactiva- Sykes, L. R. (1986). Earthquakes in the greater New York City area of the tion, Earthq. Notes 3, 66-67. past 250 years: locations, magnitudes and recurrence rates (abstract),
Seeber, L., and J. Armbruster (1986). NUREG/CR 4750, A study of earth- EOS Trans. AGU 67, 414.
quake hazards in New York State and adjacent areas: final report cover- Tantala, M., G. Nordensen, G. Deodotis, K. Jacob, B. Swiren, M.
ing the period 1982-1985, U.S. Nuclear Regulatory Commission, Augustyniak, A. Dargush, M. Marrocolo, and D. OBrien (2003) Final 1-93. Summary Report MCEER-03-SP02, Earthquake risks and mitigation Seeber, L., and J. Armbruster (1988). Seismicity along the Atlantic seaboard in the New York/New Jersey/Connecticut Region, NYCEM, The New of the U.S.: Intraplate neotectonics and earthquake hazard, in The York City Area Consortium for Earthquake Loss Mitigation, Multidis-Geology of North America, The Atlantic Continental Margin, R. E. ciplinary Center for Earthquake Engineering Research, University at Sheridan and J. A. Grow (Editors), Vol. I-2, Geological Society Buffalo, 50 pp.
America, Boulder, Colorado, 565-582. Thurber, C. H., and T. C. Caruso (1985). Crustal structure along the Ramapo Seeber, L., and J. Armbruster (1991). Technical Report 91-0021, The fault zone, New York State, Earthq. Notes 56, 145-152.
NCEER-91 earthquake catalog: improved intensity-based magnitudes U.S. Department of Commerce (1968). United States Earthquakes, 1928-and recurrence relations for U.S. earthquakes east of New Madrid, 1935, U.S. Government Printing Office, Washington D.C., 428 pp.
National Center for Earthquake Engineering Research, i-A9. Valentino, D. W., A. E. Gates, and L. Glover III (1994). Late Paleozoic trans-Seeber, L., and N. Dawers (1989). Characterization of an intraplate seismo- current tectonic assembly of the central Appalachian piedmont, Tec-genic fault in the Manhattan prong, Westchester Co. N.Y., Seism. Res. tonics 13, 110-126.
Lett. 60, 71-78. Volkert, R. A., A. A. Drake Jr, and P. J. Sugarman (1996). Geology, geo-Seeber, L., D. Johnson, and J. Armbruster (1993). NUREG/CR-5778, New chemistry, and technostratigraphic relations of the crystalline basement York/New Jersey regional seismic network: final report for April beneath the coastal plain of New Jersey and contiguous areas, U.S.
1985-1992, Vol. 3, U.S. Nuclear Regulatory Commission, 1-B19. Geol. Surv. Profess. Pap. 1565-B, 48 pp.
Seeber, L., J. G. Armbruster, W.-Y. Kim, N. Barstow, and C. Scharnberger Wheeler, R. L., N. K. Trevor, A. C. Tarr, and A. J. Crone (2005). Earth-(1998). The 1994 Cacoosing Valley Earthquakes near Reading, Penn- quakes in and near the northeastern United States, 1638-1998, U.S.
sylvania: a shallow rupture triggered by Quarry unloading, J. Geophys. Geol. Surv. Geol. Investigations Series I-2737: available at http://
Res. 103, 24,505-24,521. pubs.usgs.gov/imap/i2737/ (last accessed January 2007).
Seeber, L., W.-Y. Kim, J. Armbruster, W.-X. Du, A. Lerner-Lam, and P. Winkler, L. (1979). Catalog of U.S. earthquakes before the year 1850, Bull.
Friberg (2002). The 20 April 2002 earthquake near Au Sable Forks, Seismol. Soc. Am. 69, 569-602.
Adirondacks NY: a first glance at a new sequence, Seism. Res. Lett. 73, Yang, J. P., and Y. P. Aggarwal (1981). Seismotectonics of the northeastern 480-489. United States and adjacent Canada, J. Geophys. Res. 86, 4981-4998.
Sheridan, R. E., R. K. Olsson, and J. J. Miller (1991). Seismic reflection and Zoback, M. L. (1992). Stress field constraints on intraplate seismicity in gravity study of proposed Taconic suture under the New Jersey coastal eastern North America, J. Geophys. Res. 97, 11,761-11,782.
plain: implications for continental growth, Bull. Geol. Soc. Am. 103, Zoback, M. D., R. N. Anderson, and D. Moos (1985). In-situ stress mea-402-414. surements in a 1 km-deep well near the Ramapo fault zone (abstract),
Smith, W. E. T. (1962). Earthquakes in eastern Canada and adjacent areas, EOS Trans. AGU 66, 363.
1534-1927, Dom. Obs. Publ. 26, 271-301.
Smith, W. E. T. (1966). Earthquakes in eastern Canada and adjacent areas, 1928-1959, Dom. Obs. Publ. 32,87-121.
Stover, C. W., and J. L. Coffman (1993). Earthquake history of the Lamont-Doherty Earth Observatory of Columbia University United States, 1568-1989 (revised), U.S. Geol. Surv. Profess. Pap. Palisades, New York 10964 1527, 1-418. sykes@ldeo.columbia.edu Street, R. L. (1976). Scaling northeastern United States/southeastern Canadian earthquakes by their Lg waves, Bull. Seismol. Soc. Am.
66, 1525-1537. Manuscript received 29 June 2007