ML12258A080

From kanterella
Jump to navigation Jump to search

NRC Conference Call St. Lucie Unit 2 Steam Generator Inspection September 13, 2012
ML12258A080
Person / Time
Site: Saint Lucie  
Issue date: 09/14/2012
From:
Steam Generator Tube Integrity and Chemical Engineering Branch
To:
Johnson A
References
Download: ML12258A080 (4)


Text

NRC CONFERENCE CALL ST. LUCIE UNIT 2 STEAM GENERATOR INSPECTION SEPTEMBER 13, 2012 AREVA 86/19 TI REPLACEMENT STEAM GENERATOR (RSG)

Overview of Inspection:

  • No tube integrity issues identified
  • Average wear rate attenuation continues
  • Preliminary OA supports full cycle operation
  • Additional preventive plugging will be implemented to increase margin; similar to past inspections
  • SONGS operating experience was applied to the inspection; no issues were identified Examination Scope for third in-service inspection:
  • 100% Bobbin
  • +Point of all periphery tubes hot & cold leg
  • +Point diagnostics based on bobbin results
  • +Point discretionary profiling History of wear indications/ affected number of tubes (Cumulative):

INSPECTION YEAR 2009 2011 2012 SG A 3700/ 1231 5864/ 1862 7646/ 2211 SG B 2157/ 815 2963/ 1125 3988/ 1503 Wear rate progression (%/EFPY):

INSPECTION YEAR 2009 2011 2012 Avg.

Growth Upper 95th Avg.

Growth Upper 95th Avg.

Growth Upper 95th SG A 7.9 13.6 4.0 9.2 2.6 7.5 SG B 7.7 13.0 1.6 6.3 1.0 4.2

NRC CONFERENCE CALL ST. LUCIE UNIT 2 STEAM GENERATOR INSPECTION SEPTEMBER 13, 2012 Wear distribution:

Wear Rates 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 2009 2011 2012 Inspection Year Wear (%/EFPY)

SG A - Avg SG B - Avg SG A - 95th SG B - 95th

NRC CONFERENCE CALL ST. LUCIE UNIT 2 STEAM GENERATOR INSPECTION SEPTEMBER 13, 2012 Preliminary CMOA Results:

  • Independent assessments will be performed by Aptech and Areva
  • Maximum wear depth: 40% TW
  • Preliminary OA Results shows POB < 5%:

o 7 required tube plugs in A SG; none in B SG (All at 40%)

o Additional tubes will be plugged to provide defense in depth Tubes with multiple indications High current wear/wear rate o Wear rate increase factor of 24% applied to account for effects of power uprate.

  • Plan to inspect next outage AVB Wear Indication Depth Distribution PSL-2 SGA Sep-2012 0

500 1000 1500 2000 2500 3000 Estimated Bobbin Depth (%TW)

Number of Indications Previously-Reported Indications Newly-Reported Indications Previously-Reported Indications 161 1664 1119 849 666 481 313 119 7

0 0

Newly-Reported Indications 4

1237 325 141 59 14 2

0 0

0 0

<5%

5-9%

10-14%

15-19%

20-24%

25-29%

30-34%

35-39%

40-49%

50-59%

>=60%

NRC CONFERENCE CALL ST. LUCIE UNIT 2 STEAM GENERATOR INSPECTION SEPTEMBER 13, 2012 Secondary Side Scope:

  • Sludge Lance and Upper Bundle Flush - SG A, SG B
  • FOSAR - SG A, SG B o Metal shaving ~3 x 1/8 from SG A annulus o Beebe size part retrieved from debris screen SG B
  • Upper Steam Drum o Feedwater Ring Inspection Cover Assessment SG A, SG B o Sample of primary separators for wear SG A, SG B o General Walkdown SG A, SG B

==

Conclusions:==

  • No tube integrity issues identified
  • Average and statistical wear rate attenuation continues
  • Preliminary OA supports full cycle operation
  • Additional preventive plugging will be implemented to increase margin; similar to past inspections
  • Inspection planned after one cycle of operation