UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 1, 2012 Mr. M. J. Ajluni Nuclear Licensing Director Southern Nuclear Operating Company, Inc.
40 Inverness Center Parkway Post Office Box 1295, Bin - 038 Birmingham, AL 35201-1295
SUBJECT:
VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION, REGARDING THE 2011 STEAM GENERATOR TUBE INSPECTIONS (TAC NO. ME8339)
Dear Mr. Ajluni:
By letter dated March 30, 2012 (Agencywide Documents Access and Management System Accession No. ML12093A048), Southern Nuclear Operating Company (the licensee), submitted information summarizing the results of the 2011 steam generator tube inspection performed at Vogtle Electric Generating Plant, Unit 2. These inspections were performed during the fifteenth refueling outage.
The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided by the licensee and determined additional information is required to complete the evaluation. The NRC staff's request for additional information is enclosed.
Please provide a response within thirty (30) calendar days of the date of this letter.
Sincerely, Patrick G. Boyle, Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-425
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION 2011 STEAM GENERATOR TUBE INSERVICE INSPECTION RESULTS SOUTHERN NUCLEAR OPERATING COMPANY, INC.
VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 DOCKET NO. 50-425 By letter dated March 30,2012 (Agencywide Documents Access and Management System Accession Number ML12093A048), Southern Nuclear Operating Company, Inc., (the licensee) submitted information summarizing the results of the 2011 steam generator (SG) tube inspections at Vogtle Electric Generating Plant, Unit 2. These inspections were performed during the fifteenth refueling outage (2R15). In order to complete its review of the documents listed above, the staff needs the following additional information:
- 1. Please discuss the scope and results of any secondary side inspections (e.g., upper bundle, steam drum) performed in the SGs during 2R15 (Fall 2011).
- 2. Please confirm the accuracy of Table 3 since there is at least one duplicate entry (row 30, column 9), and the order is not discernible (neither rows nor columns are in ascending order).
- 3. Please confirm that there was no change evident in the bobbin and +Point' data between 2R 13 and 2R 15 for the tubes in row 1, column 42 and row 1, column 45 in SG1.
ENCLOSURE
August 1, 2012 Mr. M. J. Ajluni Nuclear Licensing Director Southern Nuclear Operating Company, Inc.
40 Inverness Center Parkway Post Office Box 1295. Bin - 038 Birmingham, AL 35201-1295
SUBJECT:
VOGTLE ELECTRIC GENERATING PLANT. UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION, REGARDING THE 2011 STEAM GENERATOR TUBE INSPECTIONS (TAC NO. ME8339)
Dear Mr. Ajluni:
By letter dated March 30, 2012 (Agencywide Documents Access and Management System Accession No. ML12093A048), Southern Nuclear Operating Company (the licensee). submitted information summarizing the results of the 2011 steam generator tube inspection performed at Vogtle Electric Generating Plant, Unit 2. These inspections were performed during the fifteenth refueling outage.
The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the information provided by the licensee and determined additional information is required to complete the evaluation. The NRC staff's request for additional information is enclosed.
Please provide a response within thirty (30) calendar days of the date of this letter.
Sincerely, IRA!
Patrick G. Boyle. Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-425
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
Public LPL2-1 RlF RidsNrrDorlLpl2-1 Resource RidsOgcRp Resource RidsAcrsAcnw MailCTR Resource RidsNrrLASFigueroa Resource RidsRgn2MailCenter Resour RidsNrrPMVogtie Resource RidsNrrDeEsgb Resource ce AJohnson. NRR
- via memo dated 06/19/2012 NRRlSBPB/BC GKulesa*
NRRlLPL2*1/BC NRRlLPL2-1/PM PBo Ie 07/19/12 08/01/12 08/01/12